Home / Club Marine Limited / Determination 670038

Determination 670038

Denial of cover for boat fuel tanks and engine after fuel contamination

FirmClub Marine Limited
Decided2020-09-17
ProductGeneral Insurance · Boat
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed$126,462
SourceAFCA PDF

Summary

The insurer accepted fuel pump, injector and genset damage from fuel contamination but denied the fuel tanks and engine. AFCA found the insurer liable for the fuel tanks, limited engine liability to 25% of the overhaul cost, and ordered interest with quantum to be worked out by the parties or returned to AFCA.

The insurer bore the onus of proving the wear, tear or corrosion exclusions and did not establish that long-term saltwater corrosion caused the tank damage, while engine overhaul was partly due to age and usage.

Issues

Subjects and remedies

pay claimpay interestreassess claim

Related

All Club Marine Limited determinations · Find similar determinations

Text of the determination

Determination Case number 670038 Financial firm Club Marine Limited Determination | Case number: 670038 Page 2 of 13 Case number: 670038 31 August 2020 1 Determination overview 1.1 Complaint The complainant lodged a claim with the financial firm (insurer) for damage to her boat following a fuel contamination incident. The insurer assessed the damage and subsequently accepted the claim for the fuel pumps and injectors. Later on, the insurer accepted the genset damage. However, the insurer denies cover for the fuel tank and engine. This remains in dispute. The complainant seeks the fuel tank and engine damage to be covered under the policy. 1.2 Issues and key findings Is the insurer liable for the damage to the boat fuel tank and engine? Yes. The information shows they were damaged by the contamination. However, for the engines, the insurer’s liability is limited to 25% of the cost to overhaul them. 1.3 Determination This determination is mostly in favour of the complainant. The insurer is to settle the claim as set out in section 2.1. Determination | Case number: 670038 Page 3 of 13 2 Reasons for determination 2.1 Is the insurer liable for the damage to the fuel tank and engine? It is not in dispute the boat is subject to accidental damage The complainant’s policy responds when there is ‘Accidental Loss or Damage’ to the boat. The policy defines ‘Accidental Loss or Damage’ as, ‘physical loss and/or damage which occurs by Accident’. The policy defines ‘Accident’ as ‘a happening that is u nforeseen and unintended’. The insurer accepts the genset, fuel pump and injectors has been subject to damage covered under the policy. Accordingly, it offered to settle the claim in the amount of $31,413.16. However, the insurer maintains the fuel tanks and engine were not caused by contamination. The insurer says the corrosion found in the tanks was due to saltwater and occurred gradually over time. For the engines, the insurer says the damage was due to lack of use rather than the contamination. These fall within the policy exclusions headed ‘Wear and Tear’ and ‘Delamination, deterioration, corrosion and electrolysis’. As the insurer is relying on these policy exclusions, it has the onus of proof to establish one of them applies to the fuel tanks and engine. Experts have provided differing opinions The insurer appointed engineer RC to inspect the damage and provide a conclusion as to the likely cause. RC provided a report dated 9 June 2019. RC concluded the fuel pump and injectors had been damaged by contamination. For the engine, RC found the bores of the cylinders in the engine were coated in some form of contaminant. Normally, RC would have recommended the coating be removed. However, the condition of the engine was such that it was due for an overhaul. Given this, RC recommended the engine be overhauled with the insurer contributing 25% towards this cost. The insurer appointed metallurgist and engineer (MT) on 14 April 2020 to inspect the fuel tanks. MT found the internal surface of the fuel tanks had thick brown deposits. Removal of these found deep pits penetrating the fuel tank. MT tested a sample of these deposits. This revealed high levels of zinc and iron which could not be attributed to the corrosion of the aluminium alloy tank. The corrosion pit depth and the presence of high chloride in the corrosion deposits is consistent with the corrosion being caused by seawater over a long period. This opinion was supported by the insurer’s assessor. Determination | Case number: 670038 Page 4 of 13 The complainant also engaged several experts to assess and report on the cause of damage. The complainant provided a report from her engineer (BE) dated 19 May 2020. BE identified there was ‘sticky brown residue’ on the bottom and halfway around the fuel tanks. BE also identified corrosive pitting of the internal surfaces. BE said this was likely due to the fuel contamination. BE did not accept it was plausible for saltwater to be the cause because the water would have been well above the fuel pick up pipe inlets. This would have resulted in the engines not running as it was taking water. Further, the fuel test report showed minimal water. The complainant’s expert (FS) inspected the fuel on 7 July 2019 and said:  he noted visible particulate contamination within the fuel system of the vessel  the condition of the fuel on board the vessel is likely to be corrosive  the failure of both engines was likely due to the fuel. Expert (AF) assessed and provided a report on 6 February 2020. This was after receiving RC’s report. Regarding the engine, AF says that when RC inspected the bores, it was already subject to multiple inspections and handling. These inspections resulted in the bores being wiped and the engine being turned by hand. The surface texture of the bores therefore changed substantially during this process. He noted the surface texture of bores was a gritty surface film, which was confirmed by the assessor. AF agrees with RC that the surface film did not seem to penetrate the surface of the metal. However, AF disagrees an engine in this condition should be serviced only. AF also noted that during his initial testing, he attempted to start the engines and they did not fire at all. AF provided a report in response to MT’s report. AF did not agree with MT’s conclusion for the following reasons:  it is extremely unlikely the fuel tanks have failed due to a different form of corrosion than the engines  minimal traces of water were found in the fuel samples and parts  it is not disputed the corrosion was caused by a form of corrosive agent  it is not possible for corrosive agent to be sea water over the long term. Fuel tanks were damaged by contamination Having carefully viewed the available information, the panel notes the following. BE discredits salt water as the cause of corrosion to the fuel tank. Significantly, BE explains that for the tanks to be exposed to saltwater causing pitting for a prolonged period, water would need to be well above the fuel pipe inlets. This means the engine could not run as pick-up pipes would be taking in straight water. BE explains diesel has a lower density than water and would float on top of the water . Determination | Case number: 670038 Page 5 of 13 AF says the presence of minerals is consistent with another form of corrosive contamination in the fuel. AF disagrees the presence of chlorine means the contamination is sea water. AF says chlorine could be attributed to many different types of corrosive contamination other than sea water. There is no dispute the fuel pumps and injectors have been damaged by contaminants. Given this, AF’s point is persuasive when he says that it is unlikely that the fuel tanks would have failed from a different form of corrosion to the engines. BE’s evidence is also persuasive that if sea water was the cause, then this would have affected the engines much earlier. Given all this, the panel is not persuaded the fuel tanks were damaged by long term corrosion from sea water. As the insurer has not established an exclusion applies, it is liable for the fuel tanks. Insurer liable for 25% of the cost to overhaul the engines For the engine, there is no disp ute the contamination reached them. RC’s evidence supports this. Further, there is no dispute they require an overhaul and cannot simply be serviced (as the insurer initially suggested). The question is whether this is due to their age or the contamination. On this point, the panel is persuaded by RC’s evidence. According to RC, he said the overhaul process would go beyond what was necessary to repair the damage done to the engines caused by the contamination. For instance, RC said the overhaul process would require replacement of many components that would not be necessary to fix the contamination alone. However, RC noted there was a degree of overlap. This would include removal of the engines, removal of the pistons, etc. Given this overlap, he recommended a 25% contribution. The complainant’s experts do not refute these points. AF says the surface contamination to the bores were more extensive and that no professional mechanic would start and return to service an engine in this condition. However, this does not mean that the only viable way to repair the contaminated damage is to completely overhaul the engine. Further, AF agreed the contamination did not penetrate the metal of the bores. AF also did not disagree with RC’s observations that there was a pr onounced lip to the tops of all the cylinders consistent with considerable usage and unrelated to the contamination. This pronounced lip supports RC’s observations that the engines were at a stage that they were due for an overhaul soon. Given this, the panel accepts the insurer should contribute to 25% of the engine overhaul. This would be a fair representation of the cost to repair the damage to the engines caused by the contamination. The panel is not persuaded that as the engines were likely due for an overhaul, there is no loss. This is because there is nothing to Determination | Case number: 670038 Page 6 of 13 refute the fact the engines could have remained operational for a period of time before an overhaul was due given the limited use made by the complainant. How the claim should be settled The complainant’s letter to the insurer dated 3 June 2020 set out her claim to date. She said the total claim being sought is $126,461.50. This included $99,000 plus $27,461.50 for the construction of the new tanks. In response to the insurer’s question about what the $99,000 figure comprised of, she noted the following:  the engine quote was $70,000 (50% of which is $35,000)  the fuel system quote was $49,500  less the amount not in dispute ($14,662). The complainant has not provided evidence to show the insurer’s settlement for the fuel system or the genset is unfair. This appears to leave the fuel tanks and the engine as the remaining items in dispute. For the fuel tanks, the complainant has provided four invoices for their construction. However, these do not appear to include any labour or works for the removal of the old tanks or their reinstallation. There also appears to be transportation costs for the fuel tanks not covered by the invoices. Regarding the engine, this was based on AF’s estimate. Howe ver, AF’s estimate had gaps. For instance, his estimate did not include removal of engines, refitting of engines, mooring or storage fees, etc. Therefore, it is unclear what is a fair quantum for the fuel tanks and engine should be. At the least, the insurer should reimburse the complainant for the invoices provided regarding the construction of the fuel tanks. For the balance, the parties are to work together to enable the insurer to assess the amount payable. Regarding the engines’ overhaul, the insurer’s liability should be limited to 25% of their cost. The insurer should also pay interest on any amount paid pursuant to section 57 of the Insurance Contracts Act 1984 (the Act). Interest is payable from when the insurer first denied the claim until payment is made. If the parties are unable to agree on the final quantum payable, they can return to AFCA for a decision on this point. Determination | Case number: 670038 Page 7 of 13 3 Supporting information 3.1 Terms of the policy Record Key points General exclusions These exclusions apply to all Sections of the Po licy Wear and Tear Any claim in respect of loss or damage caused by wear and tear which would be expected given the age, storage and/or us e of the applicable item. Delamination, deterioration, corrosion and electrolysi s Any claim in respect of loss or damage caused by delamination, deterioration, corrosion or electrolysis which would be expected given the age, storage and/or use of the applicable item What We will pay in the event of a claim When there is a Total or Constructive Tot al Loss of Your entire Boat or one or more Insured Components of Your Boat We will at Our option, (subject to payment of the relevant excess and any premium adjustment) either: 1. replac e Your Boat (or Ins ured Components of the Boat which have been lost); or 2. pay You the reasonable cost of repairing or replacing Your Boat (or the Insured Components of the Boat which have been lost) or 3. settle the claim by payment of a cash sum calculat ed as follows:  If an Agree d Value for the Boat or Insured Components lost has b een specified, the Agreed Value for the Boat, or Insured Components, as applicable, specified in the Schedule.  If the Boat or Insured Component is insured for Market Value – an amount based on the assessed value of the Boat or item in the immediat e pre - los s condition, but not exceeding the Sum Insured specified in the Schedule . 3.2 Expert reports Record Key points financial firm’s expert (RC ) Report 09 - 06 - 2019  Inspected components of a diesel fuel pump, and half the cylinders of the Vessel’s port side motor.  In effect, the fuel pump has a number of small pistons (one piston for each cylinder)  These pistons generate high pressures that are used for the fuel injection process.  High pressure is used to create strong atomisation since this enables fuel to evapor ate quickly and aids the combustion process.  This fuel injection pump uses mechanical seals (seals formed by Determination | Case number: 670038 Page 8 of 13 Record Key points using very close fits with tiny gaps).  The gaps are so small that very little loss is generated through such a tiny gap.  There are no ‘rubber’ type seals  This is also true for the pistons, which have close fit with the internal bores that they run within.  Found one piston and its bore, specific to each cylinder.  Found many plungers (pistons) were seized in their barrels, except for one.  Of the seized units, could not get the plungers to slide within their barrels. Moreover, in some cases, the springs that are meant to push back on the plungers, were ‘frozen’ in a compressed state.  This means that the springs that would normally push the pistons back, were incapable of doing so  Found brown deposit on some parts of the plungers and their barrels.  In places, the deposits looked like rust and able to cleanly dislodge some of this deposit, in the area where the plunger went inside its barrel.  Althou gh the deposit may look like rust, in the area where the plungers meet their barrels, its not rust because rust will not come away cleanly from a rusted surface.  In one of the bags found a plunger / barrel / spring arrangement that were clean with no brown deposits.  This aligns with comments made by BM who managed to clean one of the units.  The deposits could be removed cleanly leaves no doubt the deposits were not rust.  Based on my inspection of the fuel injection pump and the discussion by BM Fuel Injec tion, I conclude that the brown deposits that have seized the fuel pumps is some contaminant.  Did not inspect any of the fuel injectors.  Because they share the same fuel supply as the fuel injection pumps, I am certain that the fuel injectors would be sim ilarly contaminated.  In terms of what is the contaminant, I have not done any tests at this stage, to determine what it is  Cannot confirm or discount the contaminant as sugar. I strongly believe that the contaminant is not a result of the fuel drying out.  Diesel is made up of many different hydrocarbon chains and in order to form such a hard substance, considerable numbers of the fuel molecules would be needed to join together.  Even old dies el fuels do not form this type of deposit but can form wax - like su bstance.  The brown deposits on the internal surfaces of the fuel injection pump were far too hard to be a wax - like material.  Have little doubt the deposit is some form of foreign contaminant.  If necessary, it will be possible to run tests to try and determ ine the nature of that contaminant.  In all likelihood it will not change the likely conclusion that it is a Determination | Case number: 670038 Page 9 of 13 Record Key points foreign contaminant.  That testing is generally done on a comparative basis and can lead to a strong result as to the specific contaminant, if a kno wn sample of the contaminant is provided.  In the absenc e of the known contaminant, it is often the case that the testing can determine a generalised nature of the cont aminant, although it will not make a specific determination.  The degree of contamination of the fuel pumps (and the injectors too) leads me to conclude that they warrant a complete overhaul.  I could see an unusual build - up of a dark deposit.  This may be partially burnt (in engineering we say pyrolyzed) remains of some contaminant.  Apart fro m this discrete build up, the remaining soot deposition was consistent with good combustion  and injection.  Apart from the rusting towards the tops of some cylinder, the bores of all the other cylinders were generally smooth, were not pitted and were not gouged in any way.  They were not corroded. However, all the bores were coated in some form of contaminant that left them with a khaki coloured sheen.  In my experienc e, a khaki colour of a cylinder bore, is highly unusual and as such, I conclude to a high d egree of certainty, that it is some form of contaminant  Found that the contaminant in the fuel pump did not rust the fuel pump.  Although the coating of the bores appears brown, the bores are not pitted or otherwise damaged in a way that is consistent with corrosion.  The only rust found was consistent with water falling on top of an exposed cylinder during the disassembly process. financial firm’s expert (BM ) Report  When pump dismantled found the elements were all seized.  It appears that the pump seized due to the fuel drying out.  Pulled down one element and plunger assembly and cleaned the plunger and barrel and the element came up nice and clean.  The plunger freed up quite well. financial firm’s expert (MT ) Report 14 - 04 - 2020  The internal surface of the fuel tanks revealed adherent and thick brown deposits .  Removal of the deposits revealed deep pits penetrating int o the tank wall.  S ample of brown deposits was subject to solvent extraction to remove the diesel fuel.  The degreased deposits consisted of light brown to red inorganic material revealed a layered  appearance  The multiple coloured layers indicat ed that the deposits developed over a long period. Determination | Case number: 670038 Page 10 of 13 Record Key points  Most of the advanced corrosion pits were 0.6mm to 1.0mm deep from the inner wall.  The mater ial composition of the fuel tank material was typical of a 5XXX series aluminium alloy.  The results of the analysis of the internal surface deposits indicate high levels of zinc and iron that could not be attributed to the corrosi on of the aluminium alloy tank.  Aluminium and magnesium are likely to be present but are not detectable using this analysis technique.  The fuel tanks revealed evidence of pitting corrosion attack initiated on t he internal surface of the fuel tank and was accelerat ed by crevice corrosion conditions created by the presence of internal inorganic surface deposits.  The internal deposits revealed high levels of iron and zinc that could not be attribut ed to the corrosion of the aluminium plate material.  The pres enc e of high chloride levels in the deposits was consistent with seawater int o the tank.  Corrosion deposits and pitting attack to the fuel - wetted surfaces of the fuel ta nk indicated that saltwater had been present over a long period.  Corrosion data for si milar aluminium alloys indicates that the corrosion had developed on the inside of the tank over 18 months, and that penetration of the wall section would have occurred over 7.5 years . Complainant’s expert (B E ) Report 19 - 05 - 2020  The initial inspection of internal surfaces of the fuel tanks revealed a sticky brown residue on the bottom and up to around halfway up the walls of the tanks.  After the tanks were steam/pressure cleaned the surface unde r the residue showed corrosive pitt ing of the aluminium on internal surfaces.  The cause of the residue and corrosion of the tank surface would most likely be from cont amination of the fuel.  It is unlikely saltwater ingress on its own could create the brown residue seen in the tanks.  For the tanks to be exposed to saltwater to the level in the tank where pitting can be seen for a prolonged period, water would have been well above the fuel pi ck up pipe inlets.  This would mean the engines would not have run as the pick - up pipes would be taki ng in straight water, as diesel has a lower density than water and would float on top of the water.  The fuel test report from shows minimal wate r in the fuel.  The test also found Red Oxides present, likely the same contaminant that is mentioned in the MT report, that found high levels of zinc and iron on the corroded surface of the fuel tanks.  The origin of the iron and zinc is not known, this may be from the contaminant.  High chloride levels could be from a number of sources of Determination | Case number: 670038 Page 11 of 13 Record Key points contamination, the secreti on from the types of bacteria that grow in diesel fuel can be acidic which can lead to the corrosion of the fuel system (storage tanks, fuel lines, fuel pumps and injectors).  I t can also leave behind brown residues, as can other contaminants.  It is my opi nion the damage to the internal surfaces of the fuel tanks is the result of an unknown cont aminant in the fuel, and in this case not likely to be attributed to high levels of salt wate r in the fuel tanks. Complainant’s expert (AF ) Report 1 06 - 02 - 2020  This assessment relates to both primary engines and their fuel supply systems and do not include the genset.  It is assumed that the genset wi ll also be affected as I would assume that it would draw from the same fuel supply and hence have suffered the same fate.  The contaminant in the fuel pump did not rust the fuel pump or the bores of the open cylinders. The (corrosion) is not caused by the common interaction of water a nd steel but has rendered the parts inoperable. The difference between the components in the fuel pumps and the cylinder bores is that the fuel pump components remain covered in fuel and are only open to air for a few hours between the pump disassembly an d parts being washed. The cylinder bores are sprayed with contaminated fuel during cranking and left in a cylinder full of air.  I believe that our minor difference of opinion of weather the engine would have run in its original condition if the fuel pump s and injectors had been replaced with no cylinder repairs performed is due to the following.  I was called to inspect the problem sometime after it was found that the engines would not start. (approximately 6 months?)  The final component of my inspection was to remove 1 - cylinder head in November 2018.  The assessor TB’s inspection took place in the next months and it was approximately anot he r 6 months until RC’s inspection.  When RC inspected the bores they had already been subject to multiple inspections and handling and a great deal of time. These inspections had resulted in the bores being wiped with rags and fingers etc and the engine being turned by hand. The surface texture of the bores had changed substantially du ring this process and time.  The surface texture of bores was a gritty surface f ilm unlike seen previously. (this is confirmed by Todd Bakers inspection shortly after)  I do agree with RC in that it did not seem to penetrat e the surface of the metal but I d is agree any professional mechanic should start and return to service, an engine in this condition.  I believe that RC supports this position in part by stating that he Determination | Case number: 670038 Page 12 of 13 Record Key points believes that the insurer should be liable for 25% of the cost of an overhaul.  This was unsuccessful and since the engine did not fire at all I am of the opinion that the engines were of such low compression that they would not have run with any amount of diesel injected. Complainant’s expert (CD ) Report 15 - 11 - 2018 and 23 - 08 - 2019  Drained fuel from fuel pumps and dismantl e to inspect condition of parts.  F ound all element assemblies discoloured and all sliding sleeves and plungers seized from fuel contamination.  T here was also some case hardening damage on the fuel pump camshaft due to the c orrosive nature of the contamination. 23 - 08 - 19  R eins pect the fuel pumps for the purpos e of repairing into serviceable condition and found camshafts in a further state of disrepair due to the corrosiveness of the fuel. Complainant’s expert (FS ) Report 07 - 07 - 2019  V isual inspection of the fuel on board .  N oted visible particulat e contamination within the fuel system of the vessel.  The condition of the fuel on board the vessel is likely to be corrosive.  Because the vessel has experienced a failure of both engines , it is suspected to be caused by the fuel on boar d. Complainant’s expert (AF ) Report 2 No date  C ont amination issue on the vessel. Have read and refer to a report issued by M T.  The conclusion of this report states "saltwater had been present over a long period" and is implicated but not directly stated as being the cause of the failure.  I disagree with this assumption for several reasons the first of which are relevant to previo us corrosive issues with the engines etc and then by deduction from the results of this report itself.  To conclude the fuel tanks have failed due to a different cause of corrosion in the fuel than the engines is extremely unlikely.  From previous reports a nd assessments all parties agree the engine failure was caused by an unknown form of fuel contamination that was NOT water.  This is backed up by multiple fuel sample tests by both parties that the fuel had low levels of water for a land - based vehicle.  F oun d moisture content to be 245 parts per million (a p prox 50% of the allowable limit for a land based vehicle).  Found minimal traces of water in the fuel/ water traps and filters fitted to the vessel.  It is not disputed the corrosion was caused by some form of corrosive agent but it is not possible for corrosive ager to be seawater over the long term. Determination | Case number: 670038 Page 13 of 13 Record Key points  These fuel tanks are engineered that fuel is drawn from the base of the tank, achieved by placing the fittings in the top of the tank for convenience but havin g an internal tube reaching the bottom of the tank to draw maximum amount of fuel when running empty.  The base of the tank is also sloped to one corne r where pickup tubes are extended to.  My point being that if any more than 0.5 - 1.0 litre of water were to build up inside the fuel tanks this water would collect at this corner (since water is heavier than diesel) and be drawn through these tubes and fuel lines to the fu el/ water separator and filter.  The water separator had minimal a mounts of wat er present and t he fuel tank failure did not take place at this low point in the tank.  This report finds levels of zinc, iron and copper which cannot come from aluminium alloy, diesel or water so where did they come from?  The presenc e of these minerals is consiste nt however wit h there being some other form of corrosive contamination in the fuel tank s which is consistent with the outcome of all other reports and assessments of the fuel system.  The presenc e of chlorine is presented as proof that this contamination i s sea water but the fact is that chlorine could be attributed to many different types of corrosive contamination other than sea water which would then also be consistent with other reports.  My professional opinion therefore leads me to disagree with the c onclusion of this report,

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.