Home / Suncorp Group / Determination 667364

Determination 667364

Balcony membrane and window repair claim declined

FirmSuncorp Group
Decided2020-01-21
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$13,690
SourceAFCA PDF

Summary

The complainant sought $13,690 to repair a balcony membrane and windows that let water into her garage ceiling. AFCA found those repairs excluded for gradual deterioration and wear and tear, and accepted the insurer's $2,059.20 resultant damage settlement, already paid.

Expert evidence showed long-term deterioration of the membrane and silicone rather than a covered storm event, and gradual deterioration and wear and tear are excluded under the policy.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 667364 Financial firm AAI Limited Determination | Case number: 667364 Page 2 of 9 Case number: 667364 21 January 2020 1 Determination overview 1.1 Complaint The complainant holds a home building policy underwritten by the financial firm (the insurer) covering her home address. On 29 May 2019, a claim was lodged under the policy for water damage sustained to the garage ceiling. The insurer accepted the claim for the resultant water damage under the policy. However, it declined any costs associated with the repair of the waterproof membrane (the membrane) on the balcony or the window flashings, which was where the water originated from. The insurer says these items were not damaged by the storm or any other event which would be covered by the policy, but had occurred due to a combination of factors, all of which are excluded from cover. The complainant seeks the amount of $13,690 in resolution of her complaint , being the cost to remedy the balcony and windows. 1.2 Issues and key findings Was the insurer entitled to limit its liability for the claim? The insurer was entitled to limit its liability for the claim to the resultant damage caused by the water ingress. This is because the membrane and windows, which allowed the water entry, had failed in circumstances which are not covered by the policy terms. The insurer’s offer of $2,059.20 (less policy excess) for the resultant damage is reasonable and discharges its liability under the policy terms. 1.3 Determination This determination is in favour of the insurer. The insurer was entitled to limit its liability for the claim and is not required to take any further action. Determination | Case number: 667364 Page 3 of 9 2 Reasons for determination 2.1 Was the insurer entitled to limit its liability for the claim? Onus rests with the complainant to establish extent of loss There is no dispute between the parties that the complainant suffered a loss from a risk insured against for water damage to her garage ceiling, or that the insurer accepted the claim. However, a dispute has arisen between the parties as to the extent of the insurer’s liability under the policy. Principally, the complainant says the insurer is liable for the repairs to the balcony and windows, which are the sources of the water entry. She says the policy should respond to a loss such as this, which was due to a storm event. She also says the insurer’s claims handling was poor, and the source of the water was initially misdiagnosed. As the party seeking the benefit of additional cover under the policy, the onus rests with the complainant to show she is entitled to it. Policy is a defined events policy The insurer’s policy is a defined events policy. Therefore, the policy only responds where an incident caused by one or more of the listed events results in loss or damage, subject to any exclusions. There is no dispute that the complainant was provided with a copy of the policy documents at the relevant time, including the product disclosure statement (PDS) setting out the terms of cover. It is therefore fair in all the circumstances that the insurer is entitled to rely on those terms when assessing any claim made against the policy. There is also no dispute between the parties regarding the resultant damage to the garage ceiling, as the insurer has agreed to cover this. Therefore, this determination will be confined to the issue of the balco ny and windows. In order that the complainant be successful with her claim for these, she is required to show the membrane and windows were damaged in circumstances to which the policy will respond. Insurer’s experts say water entered due to long term fac tors The insurer arranged for builder ‘CR’ to inspect the property and report on the cause of the water ingress. Plumbing firm ‘PP’ also undertook leak detection tests. Relevant details of the expert reports provided in this dispute are contained in sectio n 3.2 of this determination. PP conducted leak detection tests to locate the source of water. Plumbing leaks from the wet areas of the home were ruled out, as there was no piping or drainage in the Determination | Case number: 667364 Page 4 of 9 vicinity of the balcony. PP considered the damage was due to the gradual deterioration of the membrane, which had allowed water to enter the property during heavy rainfall. Water was entering through the failed silicone joints in the windows and balcony perimeter, which was passing through the compromised membra ne into the ceiling below. These findings generally supported CR’s initial opinion as to the source of the water. Neither PP nor CR attributed this to damage by storm. Rather, this was due to a combination of factors such as wear and tear and deterioration of the silicone, grout and membrane. I accept the staff of CR and PP is suitably qualified and experienced to comment in this matter. In the absence of any contradictory information, the insurer is entitled to rely on their findings. Complainant has not presented any contradictory expert evidence The complainant disagrees with the insurer’s findings, saying PP misdiagnosed the source of the water entry. The complainant was invited to provide information in support of her position, such as a report from a suitably qualified person as to the cause of the damage. The complainant had previously presented a report from building firm ‘PR’ to the insurer, however she has not supplied anything since that time. I have considered this report as part of my review. However, review of PR’s report shows it to be largely in agreement with both PP and CR’s findings. Whilst PR considered the breakdown of the silicone around the window to be the primary or only source of water entry (rather than the tiles and grouting of the balcony itself), PR’s report is clear that had the membrane below the tiles not failed, water would be unable to penetrate the ceiling cavity through the failed silicone. This is consistent with the previous findings by the insurer’s experts. Crucially for the complainant, PR does not attribute the cause of the failed membrane to a storm, or any other event which would attract cover under the policy. Therefore, the insurer’s material is unchallenged. No valid claim established for the membrane or windows In order for the membrane and windows to be covered, they are required to be damaged in circumstances which are covered by the policy. For example, hailstones cracking the membrane due to a storm event. There is no evidence of storm damage to the membrane and/or silicone around the joins and windows, or damage which arose from any other event which would be covered by the policy. In this case, the material shows the cause of the damage to the membrane was due to gradual deterioration and wear and tear, which caused it to be compromised. There Determination | Case number: 667364 Page 5 of 9 are also other contributing factors such as the way the windows were installed. Water has then passed through the membrane at various points into the residence. That the home is leaking during periods of rainfall has simply highlighted an existing issue with the membrane and/or silicone and does not mean the storm itself was the cause of the damage. The onus to ensure the home is watertight and weatherproofed does not transfer to the insurer simply because it has insured the building. Accordingly, in the absence of conflicting information I accept the insurer is entitled to rely on the expert findings that the damage to the membrane and silicone did not arise from an incident covered by the policy. Rather, this was due to the cause of long-term deterioration and breakdown of the membrane and silicone, which has then allowed water into the home. Loss arising from these causes is specifically excluded from cover. Therefore, even if I were to accept the policy responded to the repairs required to the balcony and windows, the exclusions of gradual deterioration and wear and tear is enlivened in the circumstances. On this basis, the insurer was entitled to decline the claim for the membrane and window repairs. Insurer entitled to cash settle for resultant damage The insurer has since cash settled the claim, as it cannot warranty the works to the resultant damage until the balcony and windows are rectified. Although the complainant does not appear to dispute this aspect, for the sake of completeness I have considered this issue. The terms of the policy give the insurer the right to cash settle a claim in lieu of conducting repairs. Therefore, the insurer’s decision to cash settle for the resultant damage is in accordance with the policy terms. Where an insurer has discretion as to how to settle a claim, AFCA expects an insurer to exercise this reasonably, as cash settlement may affect an entitlement to other benefits under the policy terms such as a repair guarantee. However, there is no evidence to suggest the insurer has not done so in this instance. In circumstances where the insurer is unable to warrant the work, it is reasonable that the insurer discharges its liability by way of a cash settlement. Insurer amount for resultant damage to ceilings is reasonable CR prepared a scope of works for the damage to the ceilings, in which it was stated the repairs would cost $2,059.20 to rectify. Whilst I am mindful that this is not a prepared quotation by a licensed tradesperson, the complainant has not challenged this amount, nor has she provided any conflicting information of her own to suggest this amount is inadequate to remedy the claim- related repairs. Therefore, in the absence of any contradictory evidence, I accept Determination | Case number: 667364 Page 6 of 9 CR ’s view that $ 2,059.20 (less policy excess) is a reasonable sum to remedy the resultant damage. The insurer has confirmed this amount has since been remitted to the complainant. Therefore, no further action is required on the part of the insurer. Determination | Case number: 667364 Page 7 of 9 3 Supporting information 3.1 AFCA approach to this dispute This complaint has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous decisions of AFCA or its predecessor schemes (which are not binding). A full exchange of the relevant information has taken place between the respective parties. Each party has had the opportunity of addressing any issues raised. All of the provided material has been reviewed and considered. The parties have raised numerous issues in their submissions to AFCA. However, commentary in this determination is restricted only to those issues considered relevant to the outcome. 3.2 Relevant expert reports Record Key points Insurer’s expert (CR ) Builder’s Report 30 May 2019 (plus addendum reports of 12, 14 and 26 June 2019)  upon attendance at the property, water damaged ceiling to the garage was visible  the main damage is at the right side toward the door, with some minor damage on the left toward the wall, where water marks can b e seen running down the wall  the insured was not sure when the damage had occurred but thought it recent, within the last few weeks  the plasterboard is water stained and separating at the join and there are mould spots around the light fitting  the kitchen and tiled balcony are loc ated above the garage  the kitchen plumbing is all located on the far right of the building, so it does not appear the leaks originat ed there  we suspect the leaks are originating from the balcony at the tiled window junction, as the silicone seal has dried out and is separating from the junction  we arranged PP to attend to undertake leak detection tests  PP considers the cause of the water entry was due to failed grout, silicone seals and cracked tiles to the balcony, which has result ed in water penetrating the ceiling  we recommend the insured re - tile the balcony to ensure it is waterproof  we re - attended the property as the insured advised water had entered during heavy rain  the floor was wet in the rear near the hot water service  ther e is no obvious entry point visible and we suspect water has tracked along the floor from the existing entry points  a make safe was completed to prevent the ceiling from coll apsing  PP reattended to test the windows above the balcony  water was seen leaking through to the ceiling below during spray tests  it is assumed there is no waterproofing below the balcony or if Determination | Case number: 667364 Page 8 of 9 Record Key points there is, it has failed  we suspect the windows were not constructed to the relevant building code  insured has resided at property for two years only and would not have been aware of the issues. Insurer’s expert ( PP ) Plumber’s Report 5 June 2019 and addendum report of 20 June 2019  visual inspection found the kitchen drains and water pipes do not run in the damaged area of the ceiling, eliminating these as the source of water  this suggests the balcony is the source  there is a cracked tile on the balcony and cracked grouting on the floor  the silicone around the windows is cracked and perished, as is the silicone around the floor  all of th es e failed joins were spray tested, with water found to be dripping into the ceiling space under testing  this confirms the balcony waterproofing is compromised  site was reattended as the insured’s builder suggested the windows are the sole source of water entry  extensive spray testing was carried out to the windows to find out that water does track through the window seals into the ceiling below  the window frame base is built into the tiling which is not ideal as it then creates a tracking point through the base plate  this seems to be more a fault with the installation than how the window was constructed although comment from a qualified party on this point would need to be sought  both the windows and the tiles are leaking and are tracking water through the failed waterproofing into the garage ceiling below. Complainant’s expert ( PR ) Builder’s Report 2 July 2019  the property was constructed around 2011  the garage ceiling surface showed extensive water damage which corresponded with the locations of the windows and door frame of the kitchen above  the floor level drains adequately to the standard central drain  the level of the balcony is virtually level with the floor of the home  th e tiles are soundly adhered and there is only one crack visible  there is a silicone seal at the junction from the tiles to the windows and perimeter  most locations of the silicone show it has developed a friable appearance with gapping evident  sections of the garage ceiling were removed to det ermine the likely cause of water entry  a waterproofing membrane was not evident although it would not normally be visually obvious  a series of flood tests were conducted  there were no leaks associated with the central drain or the areas around it  water was applied directly to the silicone abutting the windows and the window weep holes and water was observed dripping int o the Determination | Case number: 667364 Page 9 of 9 Record Key points cavity after a few seconds  the issue is being caused by a combination of factors  this includes t hat the waterproof membrane does not extend under the windows and does not have a bond breaker through the junctions  the pan flashing is incorrectly located below the membrane  the windows being set down below the tile surface means that during heavy rain, water will enter through the weep tiles instead of exiting out and over the balcony tiles  this suggests the building was not constructed in accordance with AS4654. 2 - 2009 whic h was applicable at the time  even if the silicone joints become friable as they ha ve, the escape of liquid should not be possible with a correctly constructed waterproof membrane  the silicone is not the issue, it is the waterproof membrane which has been breached. This membrane is the primary tool to stop water egress in an exterior bal cony such as this.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.