Home / Suncorp Group / Determination 667364
Determination 667364
Balcony membrane and window repair claim declined
Summary
The complainant sought $13,690 to repair a balcony membrane and windows that let water into her garage ceiling. AFCA found those repairs excluded for gradual deterioration and wear and tear, and accepted the insurer's $2,059.20 resultant damage settlement, already paid.
Expert evidence showed long-term deterioration of the membrane and silicone rather than a covered storm event, and gradual deterioration and wear and tear are excluded under the policy.
Issues
- Claim denial primary · not upheld“The insurer was entitled to limit its liability for the claim to the resultant damage caused by the water ingress.”
- Claim amount dispute secondary · not upheld“The insurer's offer of $2,059.20 (less policy excess) for the resultant damage is reasonable and discharges its liability”
Subjects and remedies
home or building damageno remedy
Related
All Suncorp Group determinations · Find similar determinations
Text of the determination
Determination
Case number 667364
Financial firm AAI Limited
Determination | Case number: 667364 Page 2 of 9
Case number: 667364 21 January 2020
1 Determination overview
1.1 Complaint
The complainant holds a home building policy underwritten by the financial firm (the
insurer) covering her home address.
On 29 May 2019, a claim was lodged under the policy for water damage sustained to
the garage ceiling.
The insurer accepted the claim for the resultant water damage under the policy.
However, it declined any costs associated with the repair of the waterproof membrane
(the membrane) on the balcony or the window flashings, which was where the water
originated from.
The insurer says these items were not damaged by the storm or any other event
which would be covered by the policy, but had occurred due to a combination of
factors, all of which are excluded from cover.
The complainant seeks the amount of $13,690 in resolution of her complaint , being
the cost to remedy the balcony and windows.
1.2 Issues and key findings
Was the insurer entitled to limit its liability for the claim?
The insurer was entitled to limit its liability for the claim to the resultant damage
caused by the water ingress. This is because the membrane and windows, which
allowed the water entry, had failed in circumstances which are not covered by the
policy terms.
The insurer’s offer of $2,059.20 (less policy excess) for the resultant damage is
reasonable and discharges its liability under the policy terms.
1.3 Determination
This determination is in favour of the insurer.
The insurer was entitled to limit its liability for the claim and is not required to take any
further action.
Determination | Case number: 667364 Page 3 of 9
2 Reasons for determination
2.1 Was the insurer entitled to limit its liability for the claim?
Onus rests with the complainant to establish extent of loss
There is no dispute between the parties that the complainant suffered a loss from a
risk insured against for water damage to her garage ceiling, or that the insurer
accepted the claim. However, a dispute has arisen between the parties as to the
extent of the insurer’s liability under the policy.
Principally, the complainant says the insurer is liable for the repairs to the balcony and
windows, which are the sources of the water entry. She says the policy should
respond to a loss such as this, which was due to a storm event. She also says the
insurer’s claims handling was poor, and the source of the water was initially
misdiagnosed.
As the party seeking the benefit of additional cover under the policy, the onus rests
with the complainant to show she is entitled to it.
Policy is a defined events policy
The insurer’s policy is a defined events policy. Therefore, the policy only responds
where an incident caused by one or more of the listed events results in loss or
damage, subject to any exclusions.
There is no dispute that the complainant was provided with a copy of the policy
documents at the relevant time, including the product disclosure statement (PDS)
setting out the terms of cover. It is therefore fair in all the circumstances that the
insurer is entitled to rely on those terms when assessing any claim made against the
policy.
There is also no dispute between the parties regarding the resultant damage to the
garage ceiling, as the insurer has agreed to cover this. Therefore, this determination
will be confined to the issue of the balco ny and windows. In order that the
complainant be successful with her claim for these, she is required to show the
membrane and windows were damaged in circumstances to which the policy will
respond.
Insurer’s experts say water entered due to long term fac tors
The insurer arranged for builder ‘CR’ to inspect the property and report on the cause
of the water ingress. Plumbing firm ‘PP’ also undertook leak detection tests. Relevant
details of the expert reports provided in this dispute are contained in sectio n 3.2 of
this determination.
PP conducted leak detection tests to locate the source of water. Plumbing leaks from
the wet areas of the home were ruled out, as there was no piping or drainage in the
Determination | Case number: 667364 Page 4 of 9
vicinity of the balcony. PP considered the damage was due to the gradual
deterioration of the membrane, which had allowed water to enter the property during
heavy rainfall. Water was entering through the failed silicone joints in the windows
and balcony perimeter, which was passing through the compromised membra ne into
the ceiling below. These findings generally supported CR’s initial opinion as to the
source of the water.
Neither PP nor CR attributed this to damage by storm. Rather, this was due to a
combination of factors such as wear and tear and deterioration of the silicone, grout
and membrane.
I accept the staff of CR and PP is suitably qualified and experienced to comment in
this matter. In the absence of any contradictory information, the insurer is entitled to
rely on their findings.
Complainant has not presented any contradictory expert evidence
The complainant disagrees with the insurer’s findings, saying PP misdiagnosed the
source of the water entry. The complainant was invited to provide information in
support of her position, such as a report from a suitably qualified person as to the
cause of the damage. The complainant had previously presented a report from
building firm ‘PR’ to the insurer, however she has not supplied anything since that
time. I have considered this report as part of my review.
However, review of PR’s report shows it to be largely in agreement with both PP and
CR’s findings.
Whilst PR considered the breakdown of the silicone around the window to be the
primary or only source of water entry (rather than the tiles and grouting of the balcony
itself), PR’s report is clear that had the membrane below the tiles not failed, water
would be unable to penetrate the ceiling cavity through the failed silicone. This is
consistent with the previous findings by the insurer’s experts.
Crucially for the complainant, PR does not attribute the cause of the failed membrane
to a storm, or any other event which would attract cover under the policy.
Therefore, the insurer’s material is unchallenged.
No valid claim established for the membrane or windows
In order for the membrane and windows to be covered, they are required to be
damaged in circumstances which are covered by the policy. For example, hailstones
cracking the membrane due to a storm event. There is no evidence of storm damage
to the membrane and/or silicone around the joins and windows, or damage which
arose from any other event which would be covered by the policy.
In this case, the material shows the cause of the damage to the membrane was due
to gradual deterioration and wear and tear, which caused it to be compromised. There
Determination | Case number: 667364 Page 5 of 9
are also other contributing factors such as the way the windows were installed. Water
has then passed through the membrane at various points into the residence. That the
home is leaking during periods of rainfall has simply highlighted an existing issue with
the membrane and/or silicone and does not mean the storm itself was the cause of
the damage. The onus to ensure the home is watertight and weatherproofed does not
transfer to the insurer simply because it has insured the building.
Accordingly, in the absence of conflicting information I accept the insurer is entitled to
rely on the expert findings that the damage to the membrane and silicone did not
arise from an incident covered by the policy. Rather, this was due to the cause of
long-term deterioration and breakdown of the membrane and silicone, which has then
allowed water into the home. Loss arising from these causes is specifically excluded
from cover.
Therefore, even if I were to accept the policy responded to the repairs required to the
balcony and windows, the exclusions of gradual deterioration and wear and tear is
enlivened in the circumstances. On this basis, the insurer was entitled to decline the
claim for the membrane and window repairs.
Insurer entitled to cash settle for resultant damage
The insurer has since cash settled the claim, as it cannot warranty the works to the
resultant damage until the balcony and windows are rectified.
Although the complainant does not appear to dispute this aspect, for the sake of
completeness I have considered this issue.
The terms of the policy give the insurer the right to cash settle a claim in lieu of
conducting repairs. Therefore, the insurer’s decision to cash settle for the resultant
damage is in accordance with the policy terms.
Where an insurer has discretion as to how to settle a claim, AFCA expects an insurer
to exercise this reasonably, as cash settlement may affect an entitlement to other
benefits under the policy terms such as a repair guarantee. However, there is no
evidence to suggest the insurer has not done so in this instance. In circumstances
where the insurer is unable to warrant the work, it is reasonable that the insurer
discharges its liability by way of a cash settlement.
Insurer amount for resultant damage to ceilings is reasonable
CR prepared a scope of works for the damage to the ceilings, in which it was stated
the repairs would cost $2,059.20 to rectify.
Whilst I am mindful that this is not a prepared quotation by a licensed tradesperson,
the complainant has not challenged this amount, nor has she provided any conflicting
information of her own to suggest this amount is inadequate to remedy the claim-
related repairs. Therefore, in the absence of any contradictory evidence, I accept
Determination | Case number: 667364 Page 6 of 9
CR ’s view that $ 2,059.20 (less policy excess) is a reasonable sum to remedy the
resultant damage.
The insurer has confirmed this amount has since been remitted to the complainant.
Therefore, no further action is required on the part of the insurer.
Determination | Case number: 667364 Page 7 of 9
3 Supporting information
3.1 AFCA approach to this dispute
This complaint has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous decisions of AFCA or its predecessor schemes (which are not binding).
A full exchange of the relevant information has taken place between the respective
parties. Each party has had the opportunity of addressing any issues raised.
All of the provided material has been reviewed and considered. The parties have
raised numerous issues in their submissions to AFCA. However, commentary in this
determination is restricted only to those issues considered relevant to the outcome.
3.2 Relevant expert reports
Record Key points
Insurer’s expert (CR )
Builder’s Report
30 May 2019
(plus addendum reports of 12,
14 and 26 June 2019)
upon attendance at the property, water damaged ceiling to the
garage was visible
the main damage is at the right side toward the door, with some
minor damage on the left toward the wall, where water marks can
b e seen running down the wall
the insured was not sure when the damage had occurred but
thought it recent, within the last few weeks
the plasterboard is water stained and separating at the join and
there are mould spots around the light fitting
the kitchen and tiled balcony are loc ated above the garage
the kitchen plumbing is all located on the far right of the building,
so it does not appear the leaks originat ed there
we suspect the leaks are originating from the balcony at the tiled
window junction, as the silicone seal has dried out and is
separating from the junction
we arranged PP to attend to undertake leak detection tests
PP considers the cause of the water entry was due to failed grout,
silicone seals and cracked tiles to the balcony, which has result ed
in water penetrating the ceiling
we recommend the insured re - tile the balcony to ensure it is
waterproof
we re - attended the property as the insured advised water had
entered during heavy rain
the floor was wet in the rear near the hot water service
ther e is no obvious entry point visible and we suspect water has
tracked along the floor from the existing entry points
a make safe was completed to prevent the ceiling from coll apsing
PP reattended to test the windows above the balcony
water was seen leaking through to the ceiling below during spray
tests
it is assumed there is no waterproofing below the balcony or if
Determination | Case number: 667364 Page 8 of 9
Record Key points
there is, it has failed
we suspect the windows were not constructed to the relevant
building code
insured has resided at property for two years only and would not
have been aware of the issues.
Insurer’s expert ( PP )
Plumber’s Report
5 June 2019 and addendum
report of 20 June 2019
visual inspection found the kitchen drains and water pipes do not
run in the damaged area of the ceiling, eliminating these as the
source of water
this suggests the balcony is the source
there is a cracked tile on the balcony and cracked grouting on the
floor
the silicone around the windows is cracked and perished, as is the
silicone around the floor
all of th es e failed joins were spray tested, with water found to be
dripping into the ceiling space under testing
this confirms the balcony waterproofing is compromised
site was reattended as the insured’s builder suggested the
windows are the sole source of water entry
extensive spray testing was carried out to the windows to find out
that water does track through the window seals into the ceiling
below
the window frame base is built into the tiling which is not ideal as it
then creates a tracking point through the base plate
this seems to be more a fault with the installation than how the
window was constructed although comment from a qualified party
on this point would need to be sought
both the windows and the tiles are leaking and are tracking water
through the failed waterproofing into the garage ceiling below.
Complainant’s expert ( PR )
Builder’s Report
2 July 2019
the property was constructed around 2011
the garage ceiling surface showed extensive water damage which
corresponded with the locations of the windows and door frame of
the kitchen above
the floor level drains adequately to the standard central drain
the level of the balcony is virtually level with the floor of the home
th e tiles are soundly adhered and there is only one crack visible
there is a silicone seal at the junction from the tiles to the windows
and perimeter
most locations of the silicone show it has developed a friable
appearance with gapping evident
sections of the garage ceiling were removed to det ermine the
likely cause of water entry
a waterproofing membrane was not evident although it would not
normally be visually obvious
a series of flood tests were conducted
there were no leaks associated with the central drain or the areas
around it
water was applied directly to the silicone abutting the windows and
the window weep holes and water was observed dripping int o the
Determination | Case number: 667364 Page 9 of 9
Record Key points
cavity after a few seconds
the issue is being caused by a combination of factors
this includes t hat the waterproof membrane does not extend under
the windows and does not have a bond breaker through the
junctions
the pan flashing is incorrectly located below the membrane
the windows being set down below the tile surface means that
during heavy rain, water will enter through the weep tiles instead
of exiting out and over the balcony tiles
this suggests the building was not constructed in accordance with
AS4654. 2 - 2009 whic h was applicable at the time
even if the silicone joints become friable as they ha ve, the escape
of liquid should not be possible with a correctly constructed
waterproof membrane
the silicone is not the issue, it is the waterproof membrane which
has been breached. This membrane is the primary tool to stop
water egress in an exterior bal cony such as this.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.