Home / Capricorn Mutual Limited / Determination 663456

Determination 663456

Discretion to indemnify hail damage to main warehouse roof

FirmCapricorn Mutual Limited
Decided2020-05-04
ProductOther · Other
OutcomeFor the complainant in part
Amount awarded$158,263
Non-financial loss$1,000
Amount claimed$361,346
SourceAFCA PDF

Summary

The small business member sought indemnity for hail damage to its warehouse roof and other areas. AFCA found the insurer did not fairly exercise its discretion, ordered a cash settlement of $158,263.40 with interest, arranged repairs, and $1,000 for non-financial loss.

Expert reports confirmed hail damage to the main roof, the firm's assessment and delays were unreasonable, and the protection discretion had to be exercised fairly, with a 30% reduction for existing damage.

Issues

Subjects and remedies

natural disastersmall businesspay claimpay interestpay non financial lossrepair or rectify

Related

All Capricorn Mutual Limited determinations · Find similar determinations

Text of the determination

Determination Case number 663456 Financial firm Capricorn Mutual Limited Determination | Case number: 663456 Page 2 of 24 Case number: 663456 9 April 2020 1 Determination overview 1.1 Complaint The complainant is a member of the financial firm, which is a discretionary mutual society. Membership of the financial firm confers on its members the right to claim for the benefit of certain ‘protections’. The complainant lodged a claim in February 2019 for hail damage to his business building. The financial firm agrees to offer protection to some damage , by cash settling $47,930. It says the parties should await the views of a metallurgist about whether hail damage on the main warehouse roof needs repair. On this basis the financial firm has not yet clarified whether it will exercise its discretion to offer protection for the main roof (beyond box gutter and ventilator repairs). The complainant disputes the financial firm exercised is discretion fairly. He says its own experts confirmed hail damage to the main roof and its assessment involved unreasonable delays and decisions. Based on his repair quote, he wants the financial firm to pay $224,487 for the main roof and $136,859 for the other (accepted) areas. 1.2 Issues and key findings Did a protected event cause damage to the main roof? Hail is a protected event under the financial firm’s product disclosure statement (PDS). Three of four roofers reported hail impact to all sheets and flashings on the main roof and due to this, recommended replacement. The Panel accepts the available information supports this is physical harm caused for the purposes of the PDS. Accordingly, a protected event caused damage to the main roof. Did the financial firm fairly exercise its discretion for the main roof? The available expert information supports the main roof needs replacement. The financial firm had sufficient time to earlier appoint a metallurgist based on the experts’ views but did not. The Panel is persuaded the financial firm’s assessor did not fairly and reasonably assess the damage or take appropriate steps to progress it, given information available to him at the time. The financial firm did not provide information:  showing it considered the disputed claim under the steps required by its rules  explaining which factors its board considered in exercising its discretion to date. The Panel does not agree the financial firm is fairly exercising its discretion by refusing to cla rify its decision on the main roof before receiving a metallurgist’s report. Determination | Case number: 663456 Page 3 of 24 How should the claim for protection be resolved? In the absence of available information to the contrary, the Panel is persuaded the offer for protection should be resolved by the financial firm:  arranging its roofer to repair the rear awnings and front office roof according to PP’s itemised scope of works  cash setting the complainant $158,263.40 (70 % of the complainant’s main roof quote, to allow for existing damage as set out under the PDS, minus excess, plus the cost of internal office repairs). Did the financial firm respond to the request for protection reasonably? The Panel is not convinced the financial firm responded to the request for protection in a fair and reasonable manner overall. The financial firm is to pay the complainant $1,000 compensation for non-financial loss. 1.3 Determination This determination is substantially in favour of the complainant. If the complainant accepts this determination, the financial firm is required to:  pay the complainant $158,263.40 within 14 days  pay interest on the sum from 18 June 2019 until payment  arrange for the repairs (contained in section 2.3) to start within 30 days. Determination | Case number: 663456 Page 4 of 24 2 Reasons for determination The complainant is a small business represented in this complaint by its accountant. For simplicity, reference to the complainant in this determination includes reference to its accountant. The Panel has decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice, previous AFCA decisions and fairness. It has taken into account all the material submitted by the parties. The Panel is satisfied the documentation it has relied on has been provided to both parties. 2.1 Did a protected event cause damage to the main roof? Complainant claimed protection for hail damage In February 2019, the complainant requested the financial firm exercise its discretion to indem nify hail damage to his business building’s roof. The financial firm initially declined the request in full on 8 May 2019. On 1 November 2019, the financial firm exercised its discretion to offer partial protection, by cash settling some roof repair costs. The parties now primarily dispute whether the financial firm should exercise its discretion to grant indemnity for hail damage to the main warehouse roof. The complainant says the financial firm’s own experts confirmed there is hail damage to the main roof. He wants the financial firm to pay for repairs. The financial firm has not yet clarified whether it agrees a protected event caused damage to the main roof and if so, whether it agrees to exercise its discretion to grant indemnity. The financial firm says it is currently seeking a metallurgist’s views on the main roof and on technical information both parties provided. The financial firm says AFCA should await the outcome of the metallurgist report (which is considered in section 2.2). The Panel firs t considered if a protected event under the complainant’s membership caused damage to the main roof. Financial firm offers protections under its PDS The rights of the financial firm’s members are set out in its Product Disclosure Statement (PDS) dated 1 December 2015. The operation of the scheme is also governed by the financial firm’s co nstitution and rules. Sections 3.1 and 3.2 contain wording from the constitution, rules and PDS relevant to the issues in this determination. There is no dispute the complainant is a member and is entitled to the protection cover issued by the financial firm. The PDS says the financial firm will consider claims Determination | Case number: 663456 Page 5 of 24 for damage to the building caused by a ‘protected event’ during the ‘period of protection’. A ‘protected event’ includes ten ‘perils’. Relevant to this is ‘hail’ (as contained in section 3.1). Three of four experts report hail damage to main roof The Panel reviewed the available expert information (summarised in section 3.3), regarding whether hail damage occurred to the main roof. The financial firm engaged a qualified loss assessor (JJ). In his reports, correspondence and instructions to experts, JJ provided his own views on the likelihood, presence, nature, extent of and repairs to hail damage to the main roof. W hile it also takes JJ’s comments into account, the Panel gives substantially greater weight to opinions formed by the parties’ specialist roof and engineering contractors. The Panel is satisfied they are the most suitably qualified and experienced to give views on whether there is hail damage to the main roof (and if so, whether that damage requires repair). Of these, the first builder (CC) engaged by the financial firm stated its roofer ‘reported that extensive damage has occurred to the main roof area … as a result of being impacted by hail during a severe hail storm on 20 th December 2018’. A licensed roof tiler (RR) then engaged by the financial firm reported ‘hail damage was not evident … minor splatter marks of hail can be seen … with no evidence of d amage to any roof coverings’. RR said the absence of damage was due to a lack of indentations, despite it being ‘evident large hail had impacted roof’. The complainant’s licensed roof plumber (PP) quoted for full main roof replacement due to hail damage. A further licensed roof tiler/plumber (TT) engaged by the financial firm then reported ‘indentations and scuff marks to the roof sheets and flashings of the main factory roof as a result of recent storms’. TT stated ‘all sheets and flashings have hail dam age in sections of individual sheets and flashing lengths’. TT recommended ‘replacement of [900 square metres of] damaged roof sheets and flashings’ to the main roof. An engineer (EE) engaged by the financial firm noted TT recommended ‘a full replacement o f the main warehouse roof’ but viewed this as ‘a conservative approach’. In EE’s opinion main roof replacement was unnecessary, based on BlueScope Steel Technical Bulletin 32 (bulletin 32). EE emphasised its opinion ‘has to be confirmed by a BlueScope spec ialist consultant’. EE said the main roof had a pitch of 15 degrees and viewed its hail damage as ‘very minor’. PP then provided his views on the main roof, the available reports and a further itemised quote with scope of works (SOW). PP noted TT’s above observations on the Determination | Case number: 663456 Page 6 of 24 presence and extent of main roof hail damage, and the need for full replacement, supported PP’s earlier opinion . PP says he does not agree bulletin 32 supports EE’s view the indentations are minor, do not constitute damage and/or do no t need repair. He says the bulletin relates to post- 2010 roof sheeting, produced after the complainant’s property was built. PP reported ‘unfortunately pre 2010 all colourbond roof sheet coatings are like egg shells once damaged only time will tell [which] will corrode and [which] will slide under the radar’. He says further reasons bulletin 32 does not support EE’s conclusions are because it: does not talk about the 2 types of hail damage, there is denting hail and a punching hail, the bulletin does not refer/identify if the roofing question is 4.2 or 4.8. Overall the type of hail damage on [the property] is not aesthetic or cosmetic and falls under the definition of hail damage. This hail damage compromises the performance of the roof and the water shedding capability of the roof which will lead to early corrosion by the dirt and water ponding in these hail damage crevices’ The complainant subsequently provided BlueScope Steel Technical Bulletin 2, revision 12 (bulletin 2). This suggests minor scratches are characterised as those smaller than 2mm and unnoticeable from ground level. It stipulates scratches ‘more noticeable’ than this on new material should be replaced. However, the available information does not clarify whether this bulletin also relates to post-2010 materials, rather than those on the main roof. The financial firm did not provide any further information to challenge PP’s views. It says it is obtaining a metallurgist’s report following an attendance it says it is trying to arrange. Available reports confirm protected event damaged main roof As set out above, the complainant’s membership ‘protects loss or damage’ to his roof caused by ‘a protected event’ if the financial firm agrees to grant indemnity. The PDS defines protected events to include ‘storm’ and ‘hail’. It defines loss as ‘s udden and unforeseen physical loss’ and damage as: physical harm to tangible property that impairs its value, usefulness or normal function. The Panel is satisfied the available expert reports confirm the main roof incurred hail indentations. This is because three of four roof contractors, including two engaged by the financial firm, reported indentations to the main roof. The Panel is also satisfied PP’s, TT’s and CC’s views on the nature and extent of h ail indentations support they constitute physical harm. Further, PP’s comments and the bulletins outline the effect Determination | Case number: 663456 Page 7 of 24 of untreated hail indentations (including corrosion) and the Panel accepts this is harm impairing its usefulness and/or normal function. The Panel is not convinced EE’s views (that there is only minor damage and replacement is unnecessary) refute there is physical harm by hail damage. EE based his views on bulletin 32. After PP suggested bulletin 32 does not apply to the main roof’s materials, the financial firm did not provide any information challenge PP’s views. EE also qualified his opinion on whether repairs are needed. He highlighted any recommendation not to replace the roof would first require confirmation from a BlueScope steel consultant. As yet, the financial firm has not yet provided such confirmation. Further, if the hail indentations did not constitute damage or harm to the roof, the Panel is not persuaded CC, TT and PP would all recommend roof replacement to address those indentations. Given all the above, the Panel accepts the available reports confirm there is physical harm and/or loss to the main roof, from hail. The Panel also accepts the hailstorm was sudden and unforeseen from the complainant’s perspective. Accordingly, the Panel is satisfied the available information establishes loss or damage to the main roof from hail, a protected event under the PDS. Further, overall information supports hail damage occurred Further to the expert reports, there is no dispute between the parties a significant hail event occurred on 20 December 2018. JJ’s first report states: On the 20 December 2018, a severe storm cell with heavy rain and large hail impacted the area in this general location … The Bureau of Meteorology reports that hail the size of cricket balls was common and was one of the worst storms in the area for over 40 years. Of the other available information, a 2012 property condition report does not include any mention of leaks or roof damage. However, it does not comment on the main roof itself, or whether this was inspected. The Panel does not consider the condition report assists greatly. A letter from the insured property’s maintenance contractor (MM) states ‘since October 2017 through to November 2018, there were no reports made by the tenant to the managing agent regarding roof or ceiling leaks at the property’. A letter from an employee (NN) of the complainant’s tenant business says: I have worked … at [the insured property] for the past 7 years. During that time we had ceiling leaks due to the air conditioner installer forgetting to reseal the roof Determination | Case number: 663456 Page 8 of 24 area when the air conditioning system was refitted. This problem was fixed and the damaged ceiling Panels were replaced. Since the hail storm on 20 December 2018 the roof and ceiling area leaks when it rains. In the Panel ’s view these letters challenge to EE’s report comment that the ‘on site manager’ verbally told EE the roof has been leaking for seven years and ‘progressively worsened after the late December 2018 storm’. Further, the Panel is unable to verify what the manager said to EE. Given this the Panel is unable to form conclusions on the content, context or relevance of the comments . EE’s report of the manager’s comments also appears strongly based on views JJ expressed in his first assessment report and repeated throughout his correspondence with the financial firm. JJ explained the views were based on verbal advice he stated he received from ‘staff’, which similarly cannot be reviewed by the Panel: We did also interview the staff on site regarding the old water stained ceilings in the offices and their advice was that leaks do occur regularly when it rains heavily and has done so for a long time. The staff on hand confirmed that the rainwater ingressed into the offices via the roof and ceiling during heavy rainfall events and that this has been ongoing for a long period of time. The views EE and JJ reported a manager and staff verbally conveyed to them are unsupported by contemporaneous or independent documentation. They are directly contradicted by the confirmed absence of contemporaneous maintenance requests for leaks, and by NN’s written views. The financial firm did not provide any convincing information challenging these views. The Panel is satisfied the available information overall, including the weather, tenant’s and maintenance information, further support a protected event (the hail) caused damage to the property. 2.2 Did the financial firm fairly exercise its discretion for the main roof? PDS confers a discretion upon financial firm regarding indemnity Given the above, the Panel accepts there is a liability or loss covered by the protection under the financial firm’s PDS. However, the PDS also sets out whether and how the financial firm will consider the complainant’s request it offer protection for the main roof damage: if there is a Liability or Loss covered by the Protection, the holder of the Protection asks [the financial firm] to exercise its discretion to indemnify it and, if the Board or its delegate agrees to grant indemnity, then the Liability or Loss will be covered to the extent of the indemnity granted (which may be in whole or part) … Determination | Case number: 663456 Page 9 of 24 This confers upon the financial firm’s board a discretion as to whether grant indemnity for the main roof, and if so, its extent. AFCA expects the financial firm to exercise its discretion fairly in all the circumstances. Parties dispute financial firm has fairly exercised its discretion There is no dispute the financial firm exercised its discretion to partially accept the claim for hail damage to the building’s roof. It offered to cash settle the complainant $47,930 to repair the building’s front office and rear awning roofs, gutter ing and ventilators, based on TT’s quote. The financial firm also says TT undertakes to carry out these repairs for the quoted price, if the complainant wishes. The complainant disputes the financial firm has fairly exercised its discretion on his request for protection overall. He says:  he enabled the financial firm multiple site attendances  JJ continued to request attendances after the financial firm’s experts confirmed there was hail damage  it not fair to refuse to offer protection for the main roof give n the experts confirm there is hail damage  JJ did not carry out the assessment fairly and reasonably overall  the financial firm repeatedly deferred giving a decision, by promising updates based on outstanding information or attendances  the financial firm’s settlement amount will not allow his own contractors to carry out the repairs needed to office roof, rear awning, guttering, ventilator  the financial firm did not include internal storm damage from CC’s (6 March 2019) report in its settlement offer, without clarifying why, despite requests. AFCA asked the financial firm to clarify why it says it has exercised its discretion regarding the grant of indemnity (for the overall claim) in a fair and reasonable manner. The financial firm noted it decided not to reduce the (accepted) protection offered by:  50% of TT’s quote, even though the financial firm says TT attributed only half of the observed damage to hail  any amount for depreciation or wear and tear, even though the PDS allows for this. The financial firm also says it will provide a final decision on the main roof after the metallurgist attendance. The financial firm bases this decision on EE’s views the main roof has a 15-degree pitch and does not need replacement. The financial firm says it relies on the following exclusions in the PDS – Determination | Case number: 663456 Page 10 of 24 rust, corrosion … wear and tear, gradual deterioration …and Fair Wear and Tear – any loss, damage ….directly or indirectly from or in connection with wear, tear, rust, corrosion, erosion, oxidation, scale or gradual deterioration, lack of maintenance … or any other gradually operating cause which occurs in the course of ordinary use of property. The financial firm did not give any other reasons or supporting documents outlining why it says its exercised its discretion fairly and in line with its PDS, rules and constitution. Financial firm suggests complainant delayed attendances The financial firm says it is reasonable to defer a decision on whether to grant indemnity for the main roof, because the outstanding metallurgist’s report is relevant to the facts in this case. The Panel reviewed all the parties’ information to consider whether the financial firm’s decision, regarding its exercise of discretion, is fair in all the circumstances. The financial firm provided correspondence between JJ and various parties (including the complainant and the financial firm) ab out arranging a metallurgist’s visit. It suggests JJ attributes the following claim issues to the complainant’s inability to allow contractors to attend promptly:  delays and complexities in the claim assessment overall  the current lack of a metallurgist’s attendance and report. Given this, the Panel considered whether the complainant reasonably allowed the financial firm and its experts to assess the claimed damage. Available information refutes complainant unreasonably delayed assessment The available information supports the financial firm’s experts attended (at a minimum) on the following dates:  28 February 2019 – CC  6 March 2019 – CC’s roofer and/or RR  18 July 2019 – EE and TT  1 October 2019 – TT  7 November 2019 – JJ. Having reviewed all the information provided, the Panel does not agree with JJ’s view the complainant delayed or complicated the claim assessment. This is because:  the complainant requested protection in February 2019, over a year ago  the available information shows the complainant then allowed, rather than refused, the financial firm’s experts to attend the property Determination | Case number: 663456 Page 11 of 24  the complainant provided his dispute, with supporting documents and reasons, by 16 May 2019  this was within eight days of JJ communicating the financial firm’s 8 May 2019 decision to refuse to offer protection  until 9 July, delay then occurred because JJ overlooked the financial firm’s 22 May 2019 request he appoint a building consult to report on the damage  TT then attended on 18 July 2019, meaning the complainant allowed attendance within nine days of being asked  this does not support a view the complainant delayed or prevented access  three of four roofers who had attended, including two engaged by the financial firm, concluded hail damage occurred to the main roof by 18 July 2018  from 30 August 2019, the financial firm tried to clarify with JJ the extent of damage and necessary repairs TT and EE reported  as these attempts were unsuccessful, by 20 September 2019 JJ asked EE to obtain TT’s clarification on a SOW  TT’s reattendance occurred within two weeks (1 October 2019), which does not support a view the complainant delayed or prevented access. In view of the above the Panel is not persuaded the complainant caused unreasonable delays or is the cause of complications experienced during claim assessment. Information does not support complainant is delaying metallurgist JJ’s correspondence says the lack of a metallurgist’s report is due to factors beyond the financial firm’s control. The Panel is satisfied JJ’s correspondence suggests the complainant is causing unreasonable delays to the metallurgist’s attendance. The Panel does not agree the available information supports this view. The Panel also notes that although the complainant disputes it is reasonable, he has not refused to allow a metallurgist to attend. The complainant himself proposed a further attendance (13 November 2019) when querying the financial firm as to why the main roof repair costs were not included in its cash settlement offer. He queried (to AFCA in December 2019) why the financial firm required a metallurgist to attend, based on his view its experts already concluded there is hail damage to the main roof. He noted the number of inspections, and delay in office repairs, are now frustrating his tenants. Despite this, he agrees to a further inspection. This has not yet occurred, for the following reasons. On 18 December 2019, JJ asked the complainant to allow a metallurgist attendance for 23 December 2019, stating there would likely be few contractors available until Determination | Case number: 663456 Page 12 of 24 after Christmas. The complainant says his tenant stated the date was not convenient and a scissor lift could not be accommodated during business hours. On 6 January 2020, JJ asked the complainant to arrange access allowing a scissor lift. The complainant responded on 24 January 2020 stating the tenant stipulated a weekend or after 5pm. The parties arranged for an attendance on 5 Februar y 2020 The complainant on 4 February 2020 asked to rearrange as he had no response from PP (his roof expert). JJ asked the complainant (4 and 12 February 2020) to nominate other dates. The complainant responded (12 February 2020) suggesting JJ arrange the time as PP had since confirmed he will attend. The complainant suggested if PP is again unavailable, the inspection should go ahead regardless. The Panel does not consider the complainant’s above requests or the timeframe in which he responded to JJ’s corr espondence unreasonable. The Panel also notes JJ himself relayed to the financial firm the difficulties arranging a meeting with multiple different parties. Additionally, the financial firm’s protections cover business buildings and the complainant’s build ing is tenanted by a business. Necessarily, this requires the complainant to liaise with and reasonably accommodate his tenant’s requests. The Panel is not persuaded the available information supports the complainant is unreasonably delaying or preventing the attendance. Reasonably open to financial firm to engage metallurgist earlier in claim CC’s 6 March 2019 report stated hail damage occurred to the main roof. While RR then reported no hail damage to the main roof (17 April 2019), on 16 May 2019 the complainant challenged this with:  PP’s hail damage repair quote, including the main roof  MM ’s letter confirming, contrary to JJ’s claim decline reasons of 8 May 2019, the tenants did not ask for leak-related repairs in 2018 (before December, the month of the storm). Further, TT then reported hail damage to the main roof based on their 18 July 2019 attendance. EE’s 12 August 2019 report emphasises a BlueScope Steel consultant would be needed to confirm its speculative view no replacement was required. If the fin ancial firm considered a metallurgist’s views relevant, the Panel is satisfied the option to engage one was reasonably open to it earlier. Specifically, in response to information provided at 6 March, 16 May or 12 August 2019. Further, the Panel is not persuaded it is fair and reasonable to suggest the complainant is the cause of delays, given: Determination | Case number: 663456 Page 13 of 24  he had allowed at least five attendances by the financial firm’s experts before the financial firm suggested a metallurgist  TT’s October reattendance appears to have been required due to omissions in JJ’s instructions or TT’s/EE’s reporting  regardless, by 12 August 2019 the financial firm possessed three reports confirming hail damage occurred to the main roof  the Panel accepts delays from May until July and from A ugust until November occurred due to the financial firm (or its agents), not the complainant. Information does not support JJ’s assessment fair and reasonable overall The Panel is also not convinced JJ assessed the complainant’s request for protection fairly in all the circumstances. Opinions in JJ’s correspondence about the claim or appropriate next steps, on multiple occasions, contradicted the available independent information. For example, JJ was incorrect about the presence of hail damage. Despite this, after TT confirmed hail damage, he did not agree with the three roofing contractors who suggested replacement. JJ continued to describe it as ‘alleged’ hail damage and instead progr essed the claim on the basis of EE’s speculation the roof may not need replacement (if confirmed by a BlueScope Steel specialist). There is no indication JJ sought such confirmation at the time (12 August 2019). The available correspondence shows this occurred only after the financial firm instructed him in November 2019 to do so (a request JJ initially refused by instead suggesting a building consultant). This contradicts JJ’s view the delays are outside of the financial firm’s control or caused by the co mplainant. Overall, it appears the basis for JJ’s assessment decisions included: his own views no hail damage occurred, his own observations surrounding properties did not incur hail damage, his views tenant staff verbally reported significant pre-existing leaks (unsupported by independent confirmation), his own views the main roof also had (non-hail) existing damage and an expectation the complainant would challenge his views. Based on all the above the Panel is not convinced the financial firm (through its agent, JJ) assessed the request for protection in a fair and reasonable manner. Little information about exercise of discretion under rules and constitution The Panel is satisfied the above assessment process (including errors in decisions, delays and omissions in reporting) raises significant challenges for the financial firm to show it has exercised its discretion fairly and reasonably. This is particularly given the financial firm was aware from 16 May 2019 the complainant disputed its decision and JJ ’s views. Determination | Case number: 663456 Page 14 of 24 The PDS says the financial firm’s rules and constitution govern the exercise of its discretion and the complainant’s rights under the membership . Under its constitution, the financial firm’s board has the power and duty to consider members’ cla ims under the rules. These rules define ‘board’ to mean the financial firm’s board of directors and , as contained in section 3.2, say:  the board may also determine the conditions and extent of any acceptance  the board may delegate its discretion to managers or employees  upon a dispute, a member must first try to resolve this with a manager  if still not satisfied, the dispute may be referred to adjudication by the board at the next meeting, after which the member will receive a written determination. Based on the information the financial firm provided, the Panel is unable to be satisfied of the following:  whether the board delegated its discretion to employees (although this is implied by the financial firm’s representative’s emails, as these appear to assu me the delegation to exercise the board’s powers and duties)  all the supporting documents the board/delegates (as opposed to JJ) viewed and considered in exercising its discretion  therefore, whether the board/delegates considered all the circumstances relevant to the exercise of its discretion  therefore, the full basis of the board/delegate’s reasons for considering a metallurgist’s report is relevant  whether the complainant’s dissatisfaction about continuing delays was raised to adjudication following his initial (16 May 2019) dispute  whether adjudication occurred and if not, the reasons why not, given the initial complaint occurred 16 May 2019  if the financial firm ultimately elects not to grant indemnity for the main roof, the reasons why it says this is fair in all the circumstances (including confirmation of what informed this decision) and under the objectives in its constitution. Not fair to continue to defer decision on whether to exercise discretion The Panel is not persuaded the financial firm has sufficiently explained which disputed issues or facts it considers the metallurgist’s report will address. In the absence of other information, the Panel considers:  it is unlikely the metallurgist’s report, if obta ined, will conclude there are no hail indentations or damage (given three of four roof experts, including two engaged by the financial firm, and an engineer all reported they observed these) Determination | Case number: 663456 Page 15 of 24  it is likely the metallurgists’ views will relate to the extent o f hail indentation/damage, whether this requires repair, and if so, the appropriate method(s). As noted above, the Panel does not agree:  JJ assessed the complainant’s request for protection fairly and reasonably  the financial firm has shown it has exercised its discretion fairly in all the circumstances or in line with its constitution, rules and PDS to date  the complainant rather than the financial firm is the cause of claim delays  the financial firm has shown it was not reasonably open to it to obtain the metallurgist’s report at an earlier point . The Panel is not persuaded it is fair, given these factors, for the financial firm to continue to defer the exercise of its discretion based on its preference for a metallurgist’s report. Overall the Panel considers the financial firm did not exercise its discretion fairly regarding the request for protection for the main roof. Given this, more delay to obtain a further report is not fair in all the circumstances. The available expert reports currently available support the main roof needs replacement. The financial firm is required to exercise its discretion to grant indemnity to replace the main roof. 2.3 How should the claim for protection be resolved? Difference in parties’ repair quotes is significant The following amounts of exclusive of GST. The complainant wants the financial firm to grant indemnity on the following bases:  PP’s quote for $ 224,487 to replace the main roof  increasing the accepted (rear awning and office) roof repair settlement to meet PP’ s quote for these areas (totalling $136,859)  including CC’s repair costs for storm damage reported to the internal building ($2,372.50). CC’s roof replacem ent quote totals $116,778.75. TT’s repair quote (rear awning, front office roof, guttering and ventilation) is for $48,930. The financial firm offered to cash settle the complainant $47,930 (including an excess deduction). Determination | Case number: 663456 Page 16 of 24 The financial firm says it is entitled to reduce this by 50%, based on what it says is TT ’s view on the extent of hail damage. In making its offer, the financial firm notes it has not reduced the quote except for applying an excess. TT is to carry out quoted repairs to rear awning and office roof The areas the financial firm agrees to indemnify are the rear awning and office roof. PP’s quote is significantly higher for these respective areas ($78,650 and $65,359) than TT’s ($18,414 and $18,590) and CC’s ($22,593.75, rear awning only). In his final itemised SOW, PP convincingly sets out the materials, labour and safety allowances required. The financial firm did not give any reasons disputing or challenging these amounts. Instead, the financial firm said TT undertook to carry out the rear awning and front office repairs as quoted. In these circumstances, the Panel considers it fair for the financial firm to arrange TT (or another licensed roof tiler/plumber) to carry out repairs. However, these repairs are to include all the works PP scoped to the rear awning and front office. This is because the financial firm did not provide information challenging PP’s view a tradesperson will need to take all the steps PP’s SOW includes. Main roof repairs more accurately quoted by PP PP’s quote for repairs to the main roof area is $224,487, while CC’s is $91,299.50. TT quoted only for repairs to the box gutters and seven ventilators on the main roof ($15,290). As set out above, PP’s quote is comprehensive. TT’s does not include repairs to the main roof itself. The Panel above accepted the currently available expert material supports it needs repair. However, the Panel considers it reasonable for the significantly higher costs in PP’s quotes to be supported by explanation. The complainant provided a quote comparison and PP’s email comments on the cost differences. These outline CC’s quote:  does not include allowances in the main roof costings for removing all sheeting, wool blanket, roof wire, cappings and flashings, capping and flashing reinstatement, removing/reinstating undamaged perspex sheeting, installing roof anchor points, a scissor lift or supervision/labour  underquotes safety allowances by $4,625 (minus scissor lift costs). The Panel accepts PP has the suitable qualifications, experience and expertise to quote on these works. The financial firm did not put forward reasons challengi ng the quote’s inclusions or pricings. Further, TT ’s reports state a crane will be required, but neither TT nor CC include allowance for a crane or similar contingencies. Determination | Case number: 663456 Page 17 of 24 Given the absence of information to the contrary, the Panel accepts PP’s quote more accurately identifies the likely cost of main roof repairs. Financial firm entitled to base settlement on PDS conditions The financial firm says it is not required to pay full quote amounts, as its PDS states damage arising from a range of gradual factors (including deterioration and wear and tear) is not protected. The Panel does not agree this entitles the financial firm to refuse paying the quoted works. This is because, as set out above, the available quotes are to repair hail damage, which is protected. The Panel agrees with the financial firm’s view the available reports support there is existing, non hail-related damage also present on the roof. The Panel does not agree its presence challenges that hail damage also occurred. However, the Panel notes the financial firm’s rules and PDS outline the conditions under which the indemnity is granted. The Panel considers the presence of the existing damage supports the FF is entitled to reduce the main roof settlement. On the information provided, on balance, the Panel believes it is appropriate to reduce this amount by 30%. This is because the PDS sets out the basis of any cash settlement the financial firm will provide as: less an equitable allowance for age, wear and tear, depreciation, or betterment. TT reported the roof showed existing (non hail-related) damage approximating 25% of the total damage. The Panel is satisfied the PDS entitles the financial firm to reduce its settlement amount for the main roof by 30%, being an equitable allowance for existing damage, rather than 50% as suggested. Fair protection settlement is $$158,513.40 plus TT’s repairs PP’s GST -exclusive quote for main roof repairs ($224,487), minus 30% ($67,346.10), is $157,140.90. The financial firm did not clarify why it did not offer the cost of repairs to internal storm damage ($2,372.50), which CC reported on 6 March 2019. Given this it is required to pay these costs. This increases the settlement to $159,513.40. There is no dispute the complainant’s schedule of protection outlines a $1,000 excess applies. Determination | Case number: 663456 Page 18 of 24 Given all the above the financial firm is required to cash settle the request for protection for the main roof for $158,513.40. In the circumstance the Panel notes that the above figure is calculated, based upon a quote by PP dated 18 June 2019.The Panel believes that it is appropriate that interest be applied. The Panel notes that the financial firm may not to be bound by the Insurance Contracts Act 1984 (the Act). In the current circumstances the Panel considers that it is appropriate that the financial firm pay interest on the sum of $158,513.40. It is fair that that rate be determined at the same rate as is calculated under section 57 of the Act, from the 18 June 2019, until the date payment is made by the financial firm. As the Panel above accepted the complainant’s views the financial firm caused unreasonable delays, it is required to arrange for the rear awning and front office repairs to be able to start (if the tenants allow this) within 30 days of the complainant accepting this determination. 2.4 Did the financial firm respond to the request for protection reasonably? Non-financial loss is warranted in the circumstances Non-financial loss includes claims for stress or inconvenience caused by an error of a financial firm. The maximum amount we can award for non-financial loss is $5,000 for each claim of loss. We will only award this type of compensation if there has been an unusual degree or extent of inconvenience. When assessing whether the circumstances are of an unusual nature we will review:  the degree or extent of physical inconvenience suffered  the general time taken to resolve the complaint  the extent to which the financial firm’s actions interfered with the complainant’s expectation of enjoyment or peace of mind. AFCA may make an award of non-financial loss compensation where the complainant is a company, by taking into account the effect of unreasonable delay on a small business. In this complaint, the Panel accepts:  the financial firm did not respond to this request for pro tection reasonably overall  the complainant experienced an undue amount of inconvenience and stress as a result during these delays. The Panel accepts this caused the complainant undue stress regarding the unclear reasons for a refusal of protection and concerns over his tenants. This is particularly given: Determination | Case number: 663456 Page 19 of 24  inadequacies in the substance and processes of responses to the complainant’s complaint about the refusal of protection  JJ’s approach to the assessment overall  a lack of transparency and progression durin g the exercise of the financial firm’s discretion, particularly after TT’s 18 July 2019 report confirmed the presence of hail damage. Accordingly, the financial firm is required to pay the complainant $1,000 in non- financial loss compensation. Determination | Case number: 663456 Page 20 of 24 3 Supporting information 3.1 Product disclosure statement Part A, Introducing [the financial firm] 4.1 What types of Protections are issued by [the financial firm]? [The financial firm] issues its Members and persons entitled to become Members with Protections for their business and personal risk s and the costs associated with those risk s. A Protection is a financial product designed to manage risk and is an alternative to traditional insurance products. However, it is not insuranc e as there is no immediat e promise of indemnity. Rather, if there is a Liability or Loss covered by the Protection, the holder of the Protection ask s [the financial firm] Mutual to exercise its discretion to indemnify it and, if the Board or its delegat e agrees to grant indemnit y, then the Liabi lity or Loss will be covered to the extent of the indemnity granted (which may be in whole or part), as understood by reference to the terms of the Protection. A Member’s rights under a Protection are governed by and arise under the Constitution of [the financial firm] and the Rules made by the Board. The Rules are governed by the law of Western Australia and each party irrevocably and unconditionally submits to the non- exclusive jurisdiction of the courts of Western Australia, in this respect. Please note that, where it is stated in this section that a Protection ‘protects’ certain losses or damage, this is subject to the Board of [the financial firm] (or its delegate) exercising its discretion to grant an indemnity (in whole or part) in respect of the relevant losses or damage. Part B, Business Protections Type of Protection – Section 1. Business Buildings Summary of protection - This section protects loss or damage to your ‘Business Buildings’ from sudden or unforeseen occurrences caused by a protected eve nt. These include … storm, wind, rain or snow… and others where applicable … General Definitions Damage – Physical harm to tangible property that impairs its value, usefulness or normal function. Property Damage – Physical loss, physical destruction or physical injury to tangible property … Loss – Sudden and unfores een physical loss. Protected event – Any of the following perils … f) hail … Protection(s) – A miscellaneous financial risk product used to manage business and personal risk s, issued to a member in accordance with the [financial firm] and the Rules Rules – The doc ument called ‘Rules of [the financial firm] that governs membership and the terms of prot ection offered by [the financial firm]. General Exclusions … We will not protect you for … 13. Fair wear & tear – Any loss, damage … or expense arising directly or indirectly from or in connection with wear, tear, rust, corrosion, erosion, oxidation, scale or gradual deterioration, lack of maintenance … or any other gradually operation cause which occurs in the course of ordinary use of propert y. Section 1. Business buildings, What i s protected? Determination | Case number: 663456 Page 21 of 24 If ‘Business Buildings’ is specified in your Schedule of Protection, we will protect you for loss or damage to your business building(s) in Australia and caused by a protected event during the period of protection. Basi s of settlem ent … If there is loss or damage to your business building(s), we will, at our option, repair or replace the part of the building where there is loss or damage as far as possible to a condition substantially the same as but not better or more extensive than when new … If, at our option, we provide a cash settlement, or if repair or replacement is not carried out, we will only pay the lesser of a) the cost of repairing the business building(s) less an equitable allowance for age, wear and tear, depreciation, or betterment. What is not protected? … section 1 does not protect any claim in connection wit h or attributable to the following: … 2. Specific exclusions. We will not pay for loss or damage to or arising from … (c) rust, corrosion, oxidation … (d) wear and tear, gradual det erioration or any gradually operating cause 3.2 Rules Part Four – Claims Rules 9 – Obligations of Members and Protected Persons in respect of cl aims Determination of Claims 9(3): The Board or its delegate may det ermine in respect of a Claim which is accepted, the conditions to which the acceptance of the Claim is subject, including whether to accept the Claim fully or partially and the amount that may be payable under the Protection. Part Six – General Terms & Conditions Rule 15 – Delegation of Powers Powers of the Board 15(1): The board may exercise any power, right or discretion … or delegate any such … to the Managers. Rule 16 – Di sputes Initial consideration of disputes 16(1): In the event that a dispute arises between a Member and [the financial firm], the parties must first attempt to resolve the dispute by discussion between the Member and the Manager. Adjudication by the Board 16(2): If a Member is not satisfied with the outcome of discussions between the Member and the Manager under Rule 16(1), the dispute may be referred to the Board for adjudication … the matter will be considered at the next available meeting of the Board. The Board will mak e a determination, having regard to the Member’s written complaint and any supporting documentation provided by the Member to the Board, and this determination will be delivered to the Member in writing. 3.3 Reports Experts – main warehouse roof Expert Comments Determination | Case number: 663456 Page 22 of 24 Expert Comments Financial firm’s expert (CC) Licensed builder Quote, scope of works and report 6 March 2019  Damage has occurred throughout the main roof area, where denting is evident to the roof sheeting and whirly birds.  CAUSE OF DAMAGE: Our roofer has reported that ex tensive damage has occurred to the main roof area and rear roof area as a result of being impacted by hail during a severe hail storm on 20th December 2018. Financial firm’s expert (RR) Licensed roof tiler Report 17 April 2019  Inspection carried out on 6th March found … hail damage was not evident … Minor splatter marks of hail can be seen to, to roof where dirt and debris stains are wit h no evidence of damage to any roof coverings. On inspection it was evident large hail had impacted roof with Pitt mar ks seen however no evidence of any damage as no indentations to metal surfac e could be seen Financial firm’s expert (TT) Licensed roof tiler/plumber Report 24 July 2019  Main Factory Roof. Storm Issues: Our inspection shows that there are indentations and scuff marks to the roof sheets and flashings of the main factory roof as a result of recent storms.  We recommend removal and replacement of damaged roof sheets and flashings to match existing as closely as possible (Custom Orb – approx. 900m2). Roof rail / edge protection is required to facilitate the repairs – approx. 140lm. A crane will be required to deliver materials to the roof top and to remove existing from site to ground level. This was deemed to be a storm related issue.  There are eight industrial size roof ventilators on the roof surface, seven of which have sustained hail indentation damage during recent storms (the unit at the rear appears undamaged). We would recommend replacement of same to match existing (Industrial, Colorbond 550mm x 7). Thi s was deemed to be a storm related issue.  The existing hail damage is approximately 50% over the roof areas.  All sheets and flashings have hail damage in sections of individual sheets and flashing lengths.  Maintenance issues are approximately 25% of requ ired roof repairs, due to wear and tear.  In our professional opinion the office, main factory and awning roof areas have sustained hail damage during the recent storm event. Financial firm’s expert (EE) Forensic civil/structural engineer Caus ation report 12 August 2019  Main storage warehouse roof … Indentations and scuff marks to the roof sheets and flashings due to foot traffic … Indentations and scuff marks to the roof sheets and flashings due to hail impact Indentations to whirlybird due to hail … Estimated pitch of roof 15 degrees.  The TT roofing report recommends a full replacement of the main warehouse roof. This is a conservative approach. Given the damage to the main warehouse roof from hail is very minor and the roof pitch is 15 degrees; in ou r professional opinion there is no need to replac e the main storage warehouse roof. This is in line with the recommendations of the BlueScope Technical Bulletin No 32. This has to be confirmed by a BlueScope specialist consultant. Financial firm’s expert  Main Storage Warehouse Roof. There is minor hail damage to box Determination | Case number: 663456 Page 23 of 24 Expert Comments (EE) Forensic civil/structural engineer Supplement ary report 31 October 2019 gutter … Keeping in line with our initial rec ommendation it is our professional opinion that the damage to the box gutter due to the hail event is 50% of the total damage observed. Complainant’s expert (PP) Licensed roof plumber Report 31 October 2019  EE agree in their report that hail damage is observed on all 3 roofs. This is correct and consistent with our original findings.  In their report TT roofing agrees that a minimum of 50 percent of the roof has been affected by hail damage and rec ommends a complete re roof. This is consistent with our findings, however EE does not agree wit h TT on a full roof replace ment.  EE agree but are relying on a technical bulleting report number 3.2 supplied to them by BlueScope. EE confirmed they have not spok en with a BlueScope represent ative in relation to the above, however we can comment on this bulletin report 3.2. The bu lleting report does not talk about the 2 types of hail damage, there is the denting hail and a punching hail, the bulletin does not refer/identify if the roofing question is 4.2 or 4.8. Overall the type of hail damage on [the property] is not aesthetic or cosmetic and falls under the definition of hail damage. This hail damage compromises the performance of the roof and the water shedding capability of the roof which will lead to early corrosion by the dirt and water ponding in these hail damage crevices.  E E rely on Bluescope bulletin 3.2, further investigation would clarify that this report is for roofs made from new Colourbond coatings only and not for roofs pre 2010. PP stands firm on its findings and its quote. 3.4 Quotes Expert/date Comments CC 6 March 2019 Main roof: replace 790 square met res of roof sheeting, capping and flashing. Rear roof: replace 198 square met res of roof sheeting. Front roof: attempt to repair a/c fins. Computer room: repair internal damage. Lunch room: repair internal damage. [ I temised by pric e, location and work item. Contingency: a/c fins if not repairable . Summary: ] $ 116,778.75 – Total excluding GST PP 15 May 2019 Full roof replacement: $3 61, 346 excluding GST. TT 10 October 2019 $16,740 – roof replacement – front office. $19,900 – roof replacement – rear awning. $8,640 – box gutter replacement – main roof area. $6,650 – ventilator replacement. $ 48,930 total excluding GST. Determination | Case number: 663456 Page 24 of 24 Expert/date Comments PP [Provided to AFCA 3 December 2019, date on quote 18 June 2019] [ Fully i temises quote for full roof replacement: $397,480 including GST by location, work item, location, quantity/area, pric e, labour, materials. Summary:]  Front office roof - $71,500 ex cluding GST.  Main roof - $224,487 ex cluding GST.  Rear awning - $65,359 ex cluding GST.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.