Home / Hollard / Determination 651625

Determination 651625

Denial of storm damage claim to farm chicken sheds

FirmHollard
Decided2020-08-06
ProductGeneral Insurance · Business / commercial
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A farmer claimed storm damage to six chicken sheds after the insurer denied the claim as long-term deterioration. AFCA accepted storm damage to shed 2 and ordered it settled through an independent scope of works, but rejected the claim for shed 1 and other damage.

The proximate cause test showed storm caused the truss failure in shed 2 while long-term purlin sagging and deterioration caused the shed 1 damage, which falls within the wear, tear and deterioration exclusions.

Issues

Subjects and remedies

business interruptionnatural disasterpay claim

Related

All Hollard determinations · Find similar determinations

Text of the determination

Determination Case number 651625 Financial firm The Hollard Insurance Company Pty Ltd Determination | Case number: 651625 Page 2 of 19 Case number: 651625 9 July 2020 1 Determination overview 1.1 Complaint On 20 December 2012, the complainant signed a claim form and lodged it with the financial firm (insurer) for damage caused by a storm on 19 December 2012. The complainant also says there was a second storm event on 22 December 2012. The insurer denied the claim and says the claimed damage was not caused by the storm. The complainant disputes this and seeks for the claim to be accepted and paid in full. The complainant also seeks for the insurer to pay for lost profit caused by the damage. 1.2 Issue and key findings Is the insurer entitled to deny the claim? The insurer is liable for the damage to shed 2 and any loss of income associated with this damage. The insurer is not liable for any of the other damage claimed. 1.3 Determination This determination is partially in favour of the complainant. The insurer should settle the claim in the manner set out in section 2.1. Determination | Case number: 651625 Page 3 of 19 2 Reasons for determination 2.1 Is the insurer entitled to deny the claim? Complainant must establish a valid claim The complainant must establish, on the balance of probabilities, it suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. The policy provides cover for loss or damage to farm property directly caused by an ‘Insured Event’. ‘Insured Events’ include ‘ Storm and rainwater ’ and ‘Accidental Damage’. ‘Accidental Damage’ responds to accidental loss or damage. The policy does not define the term ‘accidental’ . However, this is commonly understood to mean an incident that is unintended and unexpected. Accordingly, to establish a claimable loss (a prima facie claim), the complainant must show the damages being claimed were either:  directly caused by a storm, or  unintended and unexpected. The policy limits cov er to the ‘limit shown for each item or catego ry of item on your Insurance Certificate’ . The insurance certificate (COI) has a sum insured of $450,000 for each of the six ‘chicken sheds’ and their attached infrastructure. The policy further limits cover under the ‘Accidental Damage’ insured event to t he sum insured for accidental damage shown on the COI. The COI has a sum insured for accidental damage of $250,000. Insurer says damage is not covered by the policy The claim was lodged with the description ‘Wind storm damage Chook Sheds’ and the damage wa s described as ‘Shed rafters & iron were bent out of shape’. The insurer accepts there is damage to the chicken sheds. However, the insurer says the damage was not caused by the storm and is instead the result of long-term aging, gradual deterioration, and wear and tear. The insurer also says the damage was not directly caused by ‘Storm and rainwater’. The ‘Accidental Damage’ insured event contains specific exclusions. The insurer has relied on several of these to deny the claim under this section. The exclusions the insurer relies on relate to:  inherent vice or latent defect  wear, tear, and gradual deterioration  error or omission in design, plan or specifications or failure of design  settling, seepage, shrinkage or expansion. Determination | Case number: 651625 Page 4 of 19 Insurer’s experts say there is damage caused by aging and deterioration The insurer appointed a building consultant (LD) to report on the damage and its cause. LD provided a report dated 9 May 2013 and in it says:  the sheds were full of chickens which made detailed inspection difficult  the sheds do not have wall or roof bracing and the timber purlins do not have bridging between them  the two older sheds with the greatest sagging run in an east west direction and the storm hit from the west LD noted the timber purlins are sagging in a vertical direction. LD said that had the sagging been caused by the storm, he would expect the timber purlins to fail in a horizontal direction. He would also expect some of the purlins to have split or broken and the roof sheeting fixing devices to have been pulled out. There was no evidence of this. LD therefore recommended an engineer be appointed to provide a more detailed inspection once the chickens have been removed. The insurer appointed an engineer (MK) who, in its report dated 23 May 2013, says:  the uniformity of the deformation of the roof material seems common to many of the buildings and gives the impression of being gradual deformation rather than a ‘ One off Event ’ .  the uniformity, evenness and consistency of deformation in shed 1 is consistent with, and indicative of, long term settlement and deformation  the roof purlins have no midspan bridging support and this has allowed deformation to occur  the roof purlins in shed 1 do not meet current Australian standards. Design checks were undertaken for the normal dead and live loading in line with the current standards: > it was found the basic working stress was exceeded and the allowable deflection exceeded appropriate limits. The actual calculated deflection appears to match what has occurred on site > the purlins were inadequate for the design wind velocity and appropriate wind loading for the site  to assess these buildings for potential storm damage is a complex exercise. Storm events can differ widely in their intensity from one location to another and obtaining accurate wind data beyond recognized weather stations can only be interpolated at best  generally, wind damage will be concentrated and not consistently uniform throughout a building  a close inspection of roof trusses in shed 2 reveals a failure of the roof trusses at the apex of the main steel portal frames. This is typical of high wind damage. Determination | Case number: 651625 Page 5 of 19 However, shed 1, which is to the immediate west of shed 2, does not have the same degree of damage despite the direction of prevailing winds. Shed 1 should have been more susceptible to damage. Complainant’s expert says damage is caused by a storm The complainant engaged an engineer (WB) who provided a letter dated 31 October 2014. This letter says:  under today’s standards these sheds w ould not be approved. However, they likely met the standards at the time they were built.  shed 1: > the timber purlins have bowed badly but this is due to age not a storm event > the entire shed appears to have moved 150 mm along its length at eaves level > this shed will have received the full brunt of the storm so damage to this building could have been more severe > the wind has hit the shed and the lack of wall bracing has allowed the shed to move approximately 150 mm along its length causing damage to the cooling panels along the walls and to other non-structural items > the shed is still structurally sound  shed 2: > there is storm damage to the pipe trusses. The top chord has bent downwards and there is some sideways bending > the top of the columns have bent where the trusses attach to the columns > the bending of the trusses at or near the apex and the bending of the top of the columns are indications the roof of the shed has been lifted during the storm and dropped back onto the columns > the damage to this shed is quite severe and is no longer structurally sound and will need to be demolished and re-built. WB also provided further letters dated 9 December 2019 and 1 April 2020. In these WB says:  his first inspection says there is serious structural damage to the trusses (or main structural members of sheds 1 & 2)  his second inspection confirms this  the trusses have been subjected to a severe uplift loading by the wind  the roof has then dropped back down creating a severe compression loading of the top chord of the trusses at the position of maximum movement near the apex  if a minor wind lifted the roof again and dropped back onto the trusses, complete failure of the building would occur  the sheds are very dangerous to any chickens or person within  both sheds 1 & 2 will have to be rebuilt. Determination | Case number: 651625 Page 6 of 19  this type of damage to a roof structure can only be caused by strong winds usually associated with a storm front. Complainant lodged another claim in 2014 On 17 November 2014, the insurer inspected the shed in relation to a separate storm claim lodged on 5 November 2014. This claim was accepted and settled. There is no information to suggest the complainant raised WB’s report during the 2014 claim despite WB’s inspection occurring only days before that storm. The insurer’s inspection report for the 2014 claim notes shed 6 now has similar damage to shed 1 and 2. Proximate cause of the loss must be determined When considering if a complainant has shown a valid claim or if an exclusion applies, it is necessary to assess what the proximate cause of the damage is. If the proximate cause is excluded from cover, the insurer will generally be able to deny the claim. Proximate cause is not necessarily the first or the last or the sole cause of the damage. It is the dominant or effective or operative cause. The proximate cause of the loss is a question of fact to be determined based on the surrounding circumstances. Shed 2 is covered Both engineers agree the sheds would not meet the current building standards. However, WB says they likely would have met the standards at the time they were built. MK does not refute this. MK says the lack of midspan bridging has allowed the downward deformation of the roof. Shed 1 is positioned to the west of shed 2. MK believes shed 1 would have been more susceptible to damage from the storm than shed 2 as the storm came from the west. However, MK does acknowledge storms can be complex. The panel notes no evidence was provided to show the storm came from the west direction. The panel also notes the complainant refers to a second storm which does not appear to have been addressed. In 2014, WB said the timber purlins in shed 1 had bowed badly due to age, not a storm event. He said shed 1 was structurally sound and indicated it was repairable. By 2019, WB says shed 1 needs to be rebuilt. This indicates the damage to shed 1 has become worse over the five years since the first inspection. This is consistent with MK’s evidence that this damage is long term. WB’s 2014 report and MK’s evidence are relatively consistent in showing the structural issues with shed 1 is not directly caused by the storm. Both refer to the fact that the timber purlins bowed quite badly due to age rather than a storm event. Determination | Case number: 651625 Page 7 of 19 The panel is not persuaded by WB’s later reports which now say the trusses damaged in shed 1 is consistent with storm damage. This report was provided about 5 years later. It is inconsistent with his contemporaneous report and MK’s findings. For shed 2 however, both WB and MK identify a failure of the roof trusses at the apex. MK also noted this is evident in many of the steel portal frames in the building. Significantly, MK says this ‘failure is typical of high wind damage’. WB agrees with this. This shows both engineers agree that there is storm damage to shed 2. In particular, MK’s evidence is far from clear in saying this damage was caused by other factors identified or that those other factors were the proximate cause. The panel notes that during the dispute, the insurer attempted to have another engineer inspect the sheds. For various reasons, this was unable to be facilitated. However, it is unclear to what extent this would assist the insurer. In this regard, the panel considers greater weight would go to the contemporaneous engineering reports available. Having considered the available information the panel is satisfied, on the balance of probabilities, the proximate cause of the claimed damage to shed 1 is long-term aging and deterioration. For shed 2 though, the panel is persuaded the proximate cause of the damage is storm. This is consistent with both contemporaneous engineer reports. Whilst the panel acknowledges the purlins were inadequate based on current standards, there is no evidence to show they were defective at the time of construction. Neither is the evidence persuasive that they were the proximate cause of the loss. There is also no dispute there was a storm and that damage was caused by this event Therefore, the panel accepts the structural damage to shed 2 should be accepted. Other damage claimed is not covered The complainant has also claimed for other damage he says was caused by the storm. This includes the following:  damaged rooflines to sheds 4 to 6  damaged roller door and cool shed to shed 6  damaged fibro surrounds to sheds 3 and 6  caps blown off on the sheds  damaged side curtains in sheds 3 and 4  damaged cool pads in sheds 3 and 4  damaged flooring in shed 3 The complainant has provided various photos to support his position. Determination | Case number: 651625 Page 8 of 19 The panel is not persuaded that these items are payable. They were not noted on or commented by any of the contemporaneous assessment or engineer reports. There is no assessment that these items were damaged by the claimed storm rather than from other factors or events (e.g. wear and tear). Further, given the time that has passed, there will no way for the insurer to be able to meaningfully assess this damage, and as such has been severely prejudiced. Therefore, the panel does not accept the insurer is liable for the other damage claimed. Insurer liable for lost profit and reduced production for shed 2 only The complainant has claimed for lost income. The policy responds for farm income in the following circumstances: We will pay up to the sum insured shown on your Insurance Certificate for loss of farm income arising from loss or damage to property that is insured under the Farm Property or General Property sections of this policy Based on the available information, and given damage to shed 2 falls within the cover provided, the panel is persuaded the insurer would be liable for any loss of farm income which can be shown to have resulted from the damage to shed 2 only. How the claim should be settled The panel notes WB says shed 2 should be rebuilt. MK made no such assessment. The panel is not persuaded by WB’s report alone given:  it appeared the complainant was using the shed for at least seven years after the claimed event, and  it is not clear if the recommendation to rebuild was due to the storm damage or the fact the structure is inadequate based on current standards Given this, the panel considers it is fair the insurer is given an opportunity to assess the works necessary to repair the damage to shed 2. To this end, the parties should do the following:  agree to the appointment of an independent engineer with no prior involvement in the claim  this engineer is to compile a scope of works to repair the damage to shed 2 caused by the storm – in doing so, s/he must be given access to shed 2, the reports provided by the other engineers and all photos of the damage to shed 2 taken contemporaneous to the event Determination | Case number: 651625 Page 9 of 19  at least one quotation is to be obtained by the insurer for these scope of works from a contractor prepared to do the works for the complainant – if more than one quotation is obtained, then the average of all the quotations is applicable; the quotation must be at today’s costs and be actionable  the insurer can cash settle based on this amount provided it does not exceed the sum insured of $450,000 For any lost income, the insurer is entitled to assess this in accordance with the policy. This is because there is no information provided to substantiate any award. Therefore, the complainant will be required to provide any information (such as financial records) the insurer requires to assess this aspect of the claim. Determination | Case number: 651625 Page 10 of 19 3 Supporting information 3.1 Our approach to this complaint We have considered it appropriate to expedite this complaint in accordance with the Operational Guidelines to the AFCA Rules, due to the nature of the complaint. Accordingly, this complaint has not been the subject of a preliminary assessment and has proceeded directly to determination. The determination is made by a panel consisting of the ombudsman together with a representative who has extensive experience in consumer claims and a representative who has extensive experience in the insurance industry. This complaint has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous decisions (which are not binding). There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any issues raised by the other. All of the material provided by the parties has been reviewed and considered. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. It is an accepted principle of general insurance law that an insured bears the onus to establish, on the balance of probabilities, they have suffe red a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove, on the balance of probabilities, an exclusion applies if it seeks to deny or limit its liability for the loss. 3.2 Relevant policy wording Subject Terms Farm Property - 1. Words with special meaning in this section farm buildings mean all fixed structures other than residential buildings, which are at the location and are listed on your Insuranc e Certificate as being used in connection with the farm business. Farm buildings include tanks, fixed plant and services that are attached to and form part of any farm buildings. Farm buildings DOES NOT include fencing, power poles and the overhead wiring b etween the power poles farm improvements means silos, windmills, boundary fencing, internal fencing, yards, ramps, races, troughs, feeders, power and telephone poles, wiring and any of their accessories for Determination | Case number: 651625 Page 11 of 19 Subject Terms which you are legally liable. It also includes t rees that are not grown as a commercial crop, which are us ed as windbreaks or for sanitary/soil erosion cont rol purposes. The cover for farm improvements is limited to the improvements that you have elected to insure and which are listed on the Insuranc e Certificate. Farm Property - 2. What we cover We will cover you for loss or damage to insured farm property at the location directly caused by the events listed under ‘Ins ured Events’ up to the limit shown for each item or category of item on your Insurance Certificat e. Farm Property - 3. Insured Events We will cover you for loss or damage caused directly by the following insured events: … Storm and rainwater Storm and Rainwater includes water and any other liquid discharged from the mains, pipes, gutters, drains, tanks or fixed apparatus used to hold or carry liquids … Accidental damage We will cover you for accidental loss or damage to Farm buildings and Farm contents provided that the loss or damage is not already covered by or able to be insured by or is not excluded by any other section of the policy, whether or not you have elected to insure under any or all of these sections. There is no cover for accidental damage to farm produce, farm machinery, hay, grain, wool or livestock. The maximum am ount we will pay for any one event under this accidental damage cover is the sum insured shown on your Insurance Certificate for Accidental damage. We will not cover accidental loss or damage caused by or involving: 1. fermentation, heating or any process in volving the application of heat; 2. roots from trees; 3. rust or oxidation, mildew, mould, wet or dry rot, corrosion, change of colour, atmospheric conditions or other variations in temperature, evaporation, diseas e, inherent vic e or latent defect, loss of weight, change in flavour, texture or finish; 4. deterioration and putrefaction of refrigerated goods; 5. loading or unloading, delivery or dispatch; 6. faulty packing or storage; 7. mechanic al, hydraulic, electrical or electronic breakdown, failure, malfunction or de rangement of any machine or electrical device or temperature controlling equipment; 8. contamination or pollution; 9. wear, tear, fading, scratching, marring, gradual Determination | Case number: 651625 Page 12 of 19 Subject Terms deterioration, normal upkeep or making good; 10. error or omission in design, plan or specification s or failure of design; 11. theft; 12. fraud or dishonest acts, embezzlement, forgery, erasure, counterfeiting and fraudulent misappropriation by electronic means or otherwise; 13. unexplained inventory short age, unexplained disappearanc e, disappearance resulting from clerical or accounting errors or shortage in the supply or delivery of materials to or from you; 14. loss or damage caused to: - vehicles, caravans, trailers, motor cycles, watercraft, aircraft or aerial devices; - property insured during and as a result of i ts processing; - property insured during construction, erection, renovation or demolition; - property in transit. 15. insects, vermin, moths or by the pecking, clawing, eating or nesting by birds and other wildlife; 16. faulty materials or faulty workmanship; 17. any orde r of any government, public or loc al authority including the confiscation, nationalisation, requisition, repossession of or damage to any property; 18. computer virus; 19. loss of or damage to property directly or indirectly caused by or contributed to by normal settling, seepage, shrinkage or expansion in buildings or foundations, walls, pavements, roads and ot her structural improvements, creeping, heaving and vibration. 20. any pers on deliberately switching off or disconnecting the power supply. 3.3 Expert reports Reco rd Key points financial firm’s expert (LD ) Building consultant’s r eport 9 May 2013 Observations and Di scussions  At the time of the inspection the chicken sheds were full of chickens and could not be inspected fully. The chicken sheds will be empty in approximately 14 days from the date of the inspection and may be then fully inspected. The Chicken Sheds  At the time of the inspection the sheds were full of chickens which presented difficulties in undertaking a detailed inspection.  The chicken sheds ha ve been constructed over approximately the last 30 years.  The older sheds have been constructed from steel pipe columns and steel pipe webbed trusses. Timber purlins have been used. This was a common form of construction of chicken sheds in the Determination | Case number: 651625 Page 13 of 19 Reco rd Key points 1980s. The sheds do not have wall or roof bracing and the timber purlins do not have bridging bet ween them. I would have expected the walls would have had bracing between the columns and in the roof.  The newer sheds are of a similar construction and in some of the sheds the timber purlins have been replaced with C section steel purlins.  The insured has claimed that the wind storm has hit the end of the Older Sheds which has caused a concertina effect, which has caused the timber purlins to sag from the pressure. Th e older two sheds with the greatest sagging of the timber purlins run in an east west direction. The storm hit the sheds at the end from a westerly direction.  The newer sheds which run in a north south direction have not experienced the sagging of the tim ber purlins to the same extent as the sheds running in an east west direction. These sheds have experienced loosening of iron sheeting and air conditioner flashings which the insured has repaired.  It is feasible that the storm hitting the end of the sheds has caused the sagging of the timber purlins.  The timber purlins are sagging in a vertical direction.  Had the sagging of the timber purlins been resultant from a storm, I would have expected to see the timber purlins fail in a horizontal direction from the impact forces from a concertina effect. Some of the purlins may have split or have broken from the impact of the forces applied. The roof sheeting fixing devices would have also pulled out from the impact forces applied.  I did not see evidence of the timber purlins failing in a horizontal direction, cracked or broken purlins or the roof fixing devices being pulled out from the impact forces applied.  In my view I could find no clear evidence of storm related damage to the shed. There is no lifting of s heeting and fixings as one would expect to find in wind driven damage situations.  Also, I was not able to do a detailed assessment internally as the shed was, unfortunately, full of chickens at the time and it was simply impossible to do a detailed physica l examination. Ultimately, if a categoric assessment of the damage to this shed is required then an Engineer would be required to view the structure and scientific ally calculate the load bearing capacity of the bearers supporting the areas that are sagging and which are alleged to have been damaged by the storm event. If we are to do so then we would need to ascertain the actual severity of the wind gusts in the region via the BoM.  One reason for the timber purlins failing in the vertical direction may hav e result ed from the timber purlins being green or having high moisture content resulting in a high flexing ratio at the time of construction. Gravity and the weight of the roof have pulled the timber purlins down in the vertical direction due to the green timber having a high flexing ratio.  At the time of construction green timbers may have been used in Determination | Case number: 651625 Page 14 of 19 Reco rd Key points preference to seasoned timber for the ease of installing the fixing devic es. Seasoned hardwood timber is next to impossible to drive in a roofing nail or tek screw.  Naturally we are unable to categorically determine the condition of the timber at the time of construction, at this late stage.  The appointment of a consulting structural engineer would be able to determine if the timber purlins were of sufficient size for the spans and whether or not this caused the sagging to occur over time or if this or any other deficiency in conjunction with the storm caused the sagging to occur. Conclusion  The inspection of the sheds at [insured address] has revealed the following that: 1. The Bobc at Carport Shed has experienced minor damage from the storm and is repairable 2. The sheds known as the Combine Shed and Adjacent Shed have been destroyed beyond economical repair by the storm event, 3. The sagging of the timber purlins in the Older Chicken Sheds is most probably not storm created or related and 4. A structural engineer to be appointed to determine if the timber purlins were of sufficient size for the spans and if the storm was result ant for the sagging of the purlins. Financial firm ’s expert ( MK ) Engineer’s Report 23 May 2013  We wish to advis e that we have undertaken inspections of the above mentioned buildings on the 22 nd May and 24th May 2013 and we report as follows.  Whilst the aim of our site inspection was to ascertain the structural adequacy of the existing Timber Roof Purlins, several other observations were made in regard to the overall structure.  Constructed on the site are a series of Steel Portal Frame buildings, clad with corrugated iron with Hardwood timber roof purlins. Although there were slight differences in materials used the buildings were generally of similar structural content.  We will relate our discussion to building 1 and 2 the western most buildings. These buildings had a clear span of 12300mm, an eave height of 3000mm, Apex Height of 4000mm and main frame spacing of 3640mm. Columns for individual frames were 65 O.D . Pipe, and Roof members were fabricated trusses with 30 O. D . Pipe top and bottom chords and 10mm MS rod truss chords . Roof Purlins consist of 95x45 hardwood timbe r sections placed at 1200mm centres .  From an initial external visual inspection many of the sheds show deformation of the roof mat erial between the internal steel portal frames as illustrated in Figure 1 below. The uniformity of the deformation seems commo n to many of the buildings and gives the impression of being a gradual deformation with time rather than a "One off Event".  Our report will further consider this, as there do seem to be a combination of factors to take into consideration around the circums tances involved . Determination | Case number: 651625 Page 15 of 19 Reco rd Key points  The uniformity, evenness and consistency of this frame to frame deformation is consistent with and indic ative of long term settlement and deformation of the roof purlins. These roof purlins as mentioned span 3640mm and have no midspan brid ging support that has further allowed deformation under normal working stresses to occur.  A design check was undertaken on these Roof purlin members to assess structural adequacy in accordance with current Australian Standards.  Australian Standards utilize d in our assessment include > AS1720. 1 - 1988 Timber Structures Code > AS1170. 0 - 2002 Structural Design Actions > AS1170. 1 - 2002 Structural Design Actions Part 1 Permanent, Imposed and other actions > AS1170. 2 - 2002 Structural Design Actions Part 2 Wind Loads  These pur lin sections were found to be inadequate . Design checks were undertaken for two loading cases. The first case was for 1. normal Dead and Live loading and the second case considered was for 2. the appropriate wind loading for the site.  The site would be considered as a Region A Terrain Category 2 in accordance with AS 1170.2 - 2011 Structural Design Actions Part 2 Wind Loads .  Load Case 1 > It was found that the Basic Working Stress in Bending in accordance with AS 1720.1 - 1988 Timber Structures Code Part 1 Design Methods was exceeded and the allowable deflection exceeded appropriate limits . The actual calculated deflection appears to match what has actually occurred on site.  Load Case 2 > Adopting a Design Wind Velocity of 41m/s and the appropriate Wind loadin g coefficients in accordance with AS 1170 . 2 - 2011 Structural Design Actions Part 2 Wind Actions these purlin sections were found to be inadequate. Modelling was undertaken assuming a Terrain Cat egory 2 Wind Loading condition and utilising Spacegass Structur al Software.  The design analysis findings support our professional opinion that the consistency of deformation or sagging of the roof purlins evenly along the buildings is a direct result of the ageing, drying and subs equent shrinkage of the purlins, and t he inadequacy of inherent properties to perform over the required span bet ween portal frames and the subsequent spacing of the purlins (centre to centre) and the lack of Lateral Restraint in the form of sag rods or mid span bridging .  [figure 2] clearly sho ws the consistency along the building of the roof deformation between main building steel port al frames . The eave purlin can clearly be seen and has basically failed under load and weat her forces.  Of further int erest is that this consistency of deformation is apparent in other buildings furt her supporting our design and Determination | Case number: 651625 Page 16 of 19 Reco rd Key points Analysis findings that the purlin sections are inadequate for the intended purpose.  To assess these buildings for potential storm damage that may have occurred on the 22 nd December 2012 as r eported by the owner is a complex exercise. Such storm events can differ widely in their intensity from one location to another and obtaining accurate wind data beyond recognized weather stations can only be interpolated at best. What is also of further in terest in modelling these buildings under a design wind load is that the net force on the Western side of the Roof of building 1 and 2 is a net outward force. Again, the downward or inward deformation of thes e roof pur l ins does not support high wind loadin g damage that would be caused under a design wind. Different damage would be evident and this damage based on our previous experience would not be uniform as we are seeing with the roof deformation that we have witnessed. Generally wind damage will be conc ent rated and not consistently uniform throughout a building.  However, a close inspection of roof trusses in Building 2 reveals a failure of the roof trusses at the Apex of the main steel portal frames. In building 2 this is evident in many of the steel por tal frames in the building. This failure is typical of high wind damage. What is surprising however is that Building 1 to the immediate west of Building 2 does not have the same degree of damage. Building 1 given the direction of prevailing winds should ha ve been more susceptible to damage. As previously mentioned these Weather events can be complex in nature.  This report does not extend to undertaking a structural analysis and design check of the steel portal frames, however we do believe that they would p rove deficient under current design Australian Standards. Complainant’s expert ( WB ) Engineer’s Report 31 October 2014 An inspection of the above chicken sheds was carried out by [WB] on the 27th October 2014 and we report as follows: 1. Description. The sheds 1 and 2 are older sheds constructed in the early 1980's. These sheds have steel trusses made with 35 mm diametre pipe as top and bottom chords x 350 mm deep with timber purlins at approximately 1200 mm centres and 60 mm diametre columns at approximat ely 3500 mm cent res. Posts are 2300 mm above a concrete dwarf wall and the apex of the roof is 2700 mm high. The trusses span approximately 12 metres. It should be noted that under todays standards these sheds would not be approved, however under the stan dards in 1980 they would more than likely have complied. Determination | Case number: 651625 Page 17 of 19 Reco rd Key points A. Inspection - Shed 1. i) There is no wall bracing in this building. ii) The timber purlins have bowed quite badly but this is due to age rather than a storm event. iii) The entire shed appears to have move approx imat ely 150 mm along its length at the eaves level, causing a considerable amount of damage to cooling panels and other non structural items. 3. Discussion and Recommendations, shed 1. Where this shed is located it will have received the full brunt of the storm so damage to this building could have been more severe. The wind has hit the shed and the lack of wall bracing has allowed the shed to move approximat ely 150 mm along its length c ausing damage to the cooling panels along the walls and to other non structural items. This shed is still structurally sound but will require wall bracing added to strengthen the structure plus repairs to the non structural items. B. Inspection - Shed 2 i) There is storm damage to the pipe trusses, the top chord has been bent downwards near the apex on most of the trusses by approximately 50 mm, also some sideways bending. ii) Where the trusses are attached to the columns the top of the columns have bent. 4. Discussion and Recommendations, shed 2. The bending of the trusses at or near the apex and the bending of the top of the columns are classic indications that the roof of the shed has been lifted during the storm and dropped back onto the columns. The roof structure i s dropped downwards the roof causes the columns to spread and with this there is a large increases the compression on the top chord causing the bending near the apex. The top of the columns bend as the trusses spread and land back onto the columns. The dam age to this shed is quite severe and in our opinion is no longer structurally sound and will need to be demolished and re - built. Complainant’s expert ( WB ) Engineer’s Report 9 December 2019 We have reviewed the existing reports of [LD] and the report from [ M K] and advise as follows: Determination | Case number: 651625 Page 18 of 19 Reco rd Key points 1. [LD] reports of the 9th May 2013 complete reports on the timber members on all buildings. His conclusions firstly relate to two minor timber sheds, one not covered by insurance, he directs that "A structural engineer to be appo inted to determine if the timber purlins were of sufficient size for the spans and if the storm was resultant for the sagging of the purlins". [MK] 's report as directed by [LD] reports mainly on the timber members, he does comment on the buckling of the ra fters but states that "this report does not extend to undertaking structural analysis and design check of the steel portal frames ... " 2. [LD]'s second report dated 14th November 2019, makes no mention of the damage to the trusses in sheds 1 & 2 and refers u s to [MK’s firm] . 3. Our first inspection advised that there had been serious structural damage to the trusses ( or main structural members of sheds 1 & 2). Our second ins pection confirms this opinion. The trusses have been subjected to a severe uplift loading by the wind, the wind and dead weight of the roof has then dropped the centre area of the roof back down creating a severe compression loading of the top chord of the trusses at the position of maximum movement near the apex. This compression load could not be sustained by the truss top c hord and it bent sideways. We believe that if a minor wind lifted the roof again and dropped back onto the trusses, complete failure of the building would occur. In our opinion the sheds are ve ry dangerous to any chickens or person within the shed and could cause loss of life. The only item that is holding the shed up at present is the sheds roof sheeting taking the compression. We quote from our original report dated 31st October 2014 "The dama ge to this shed is quite severe and in our opinion is no longer structurally sound and will need to be demolished and re - built". It is our present opinion that both sheds 1 & 2 will have to be rebuilt. Complainant’s expert ( WB ) Engineer’s Report 1 April 2020 1. The damage to the roof trusses has been caused by uplift from suction created during a storm event, creating uplift from suction caused by the wind blowing over the top of the sheds. Some minor int ernal uplift would have occurred, but this loading wou ld only be minor compared to the loading on the roof sheeting from the suction. Determination | Case number: 651625 Page 19 of 19 Reco rd Key points This type of damage to a roof structure can only be caused by strong winds usually associated with a storm front. 2. We recommend reading our previous report again (copy attached for your convenience) as it is very clear that both shed's structural integrity is severely compromised and have to be demolished and re - built, the sheds cannot be repaired.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.