House movement and cracking claim denied; leaking pipe not proximate cause, over-jacked stumps the main cause
Text of the determination
Determination
Case number 649319
Financial firm Auto & General Services Pty Ltd
Determination | Case number: 649319 Page 2 of 10
Case number: 649319 18 March 2020
1 Determination overview
1.1 Complaint
The complainant holds and home and contents policy with the financial firm (insurer).
The complainant is represented by his son (R). For simplicity, I will refer to the
complainant and R as the “complainant.
The complainant lodged a claim with the insurer for movement and cracking damage
sustained to his home. The complainant attributed the damage to a leaking pipe
underneath the property.
The insurer assessed and subsequently denied the claim. In doing so, the insurer
says the pipe is not the cause of the damage but rather excluded factors under the
policy.
1.2 Issues and key findings
Is the insurer entitled to deny the claim?
Yes. The insurer is entitled to deny the claim, this is because:
the expert evidence does not establish the leak from the pipe to be the proximate
cause of the damage
over the years the main bearers have been over supported and installed too high
resulting in a peak in the floor levels resulting in the current damage.
1.3 Determination
This determination is in favour of the insurer.
The insurer is entitled to deny the claim and is not required to take any further action.
Determination | Case number: 649319 Page 3 of 10
2 Reasons for determination
2.1 Is the insurer entitled to deny the claim?
Policy provides cover for escape of liquid damage subject to exclusions
The complainant is required to show that, on the balance of probabilities, he has
suffered a loss caused by a risk insured against under the policy.
If the complainant is able to establish he has suffered a loss caused by a risk insured
against under the policy, then the onus shifts to the insurer to show that, on the
balance of probabilities, it is entitled to rely on an exclusion under the policy or is
otherwise entitled to deny the claim.
The complainant ’s policy provides cover for damage caused by the insured events
listed in the policy (including escape of liquid), subject to the conditions and
exclusions set out in the policy.
The property has been subject to an escape of liquid event in 2016
Following the claim’s lodgement, the insurer engaged a builder (SG) to assess
causation and the extent of the damage. In addressing causation, SG says:
the timber packers between the floor bearers and the concrete stumps are
incompressible and have contributed to the movement settlement
the increase of moisture in the subfloor as a result of the leaking pipe would have
caused a local heave rather than shrunk.
SG says he observed no cracking or building movement to the brick work. This
indicates that the recent water leak has not caused any movement to the concrete
strip footing.
Following the complainant’s disagreement with SGs’ findings. The insurer has
engaged an engineer (JH) to assess the causation of the property damage.
JH noted a number of existing cracks throughout the interior of the house which had
been repaired over the years. However, around December 2016, the cracks
reappeared and reopened. Further the most significant cracking was located to the
dining and kitchen areas being the central region of the house.
In assessing the subfloor area, JH noted:
the property has been restumped over the years
at the time of the inspection the subfloor was dry
the stumps are oddly close to each other and are located towards the central
region of the house where interior cracking was most prevalent
there are various timber packers which indicates the floor has been rele velled and
adjusted over the years.
Determination | Case number: 649319 Page 4 of 10
JH says the floor survey shows a variation across the entire floor of the house.
Further, the movement between the outer walls and the centre of the house coincided
with the row of soldier stumps.
In addressing whether the pipe has caused the claimed damage, JH says when a
pipe leaks the clay absorbs the water and the soil swells. The swelling of the soil
places pressure on footings or stumps, resulting in differential movement. JH adds
this movement causes stresses in the brickwork and plasterwork which is in turn
relieved through cracking.
JH says it is important to consider the natural direction of water flow to the lowest
point in the site. At this site the floor levels show the stumps in the central region of
the house are much higher than the outer regions of the house.
Relevant to the complaint, JH says the leak is located at the front of the house which
is slightly uphill compared to the rear and the kitchen area of the dwelling.
JH suggested two possible causes of the movement to the floor:
the leaking pipe causing the stumps within the dining room area to swell and rise.
JH expected the floor levels will reduce in height back to their original position as
the soils dry out
over the years the main bearers have been over supported and installed too high
resulting in a peak in the floor levels. Over the weather seasons the exterior
foundations have moved but the interior stumps have not causing the cracking.
JH recommended a monitoring period before a conclusion can be reached. JH says if
the movement had occurred due to a pipe leak then the floor levels will change ,
however, if the floor levels remain the same, then the movement is unrelated to the
leaking pipe.
The property has been subject to a floor level survey in 2018
In June 2018, the insurer engaged JH to re -inspect the property. JH undertook
another floor level survey and the readings were compared to JH’s 2017 floor level
survey. JH noted the low point was in the living room at the front of the house ,
whereas the highest point was in the dining room near the middle of the house.
JH says the results of the two surveys were similar. As there is no change and the soil
had dried out, the evidence indicates that the levels are permanent and were caused
by long-term differential settlement. JH concludes the soil levels in the middle of the
property had not dramatically changed over the 12 month drying period.
Further, JH asserts any effects from saturation of the soil as a result of the broken
pipe had been removed. JH concludes that the long-term differential foundation
movement was not cause by the pipe.
Relevantly in this report JH refers to the pipe as a storm water pipe.
Determination | Case number: 649319 Page 5 of 10
Following the complainant’s dissatisfaction with JH’s second report, the insurer
sought further comments from JH. In his supplementary report, JH says the
complainant contacted JH and provided new information:
the subject pipe was not a storm water pipe but rather a main water pipe
the house was restumped 40 years ago due to water
photos of the walls of the dwelling prior to and after the event.
Based on this new information, JH reassessed its findings and says:
if the leak has been occurring for a considerably time and the underfloor area was
dry, the cracks in the clay would allow water passage to significant depth
JH had an understanding the leaking pipe was a storm water pipe rather than a
water main.
JH suggests the second survey was not of significantly noticeable difference in the
floor levels due to the very slow loss of moisture at depth. Further, there might have
been an initial settlement period during the summer months following the event before
the initial levels were surveyed.
JH concluded the cracking would have occurred in similar locations to cracks that
occurred in the past. Following the new information provided by the complainant, JH
says the heave was probably as a result of the leak from the water pipe. JH
recommended another re-assessment to be taken in 2019, to assess if the heave has
settled before remedial works could be undertaken.
Subsequently JH provided further comments regarding the efficiency of each of the
possible two identified causes. JH says the primary cause of the damage is the
leaking pipe contributing to 90 percent of the movement damage. JH apportioned 10
percent of the damage to the property from movement over the years due to the
stumps being installed too high.
I note that JH at that point of time provided his view following a desktop assessment.
The floor levels in 2019 have not changed despite a two-year recovery period
At JH’s recommendation, the insurer engaged JH to conduct a further floor level
survey in May 2019.
JH says there has been no change in the levels of the underfloor of the property.
Whilst in 2018, JH suggested the leaking pipe caused a heave or settlement in the
soil, he says the recent levels no longer support such a finding. In substantiating his
finding, JH says there has been no change in the floor level since the rectification of
the cause of the leak from the pipe. Further, JH says that the leaking pipe had no
effect of the levels of the dwelling and the resultant damage.
Determination | Case number: 649319 Page 6 of 10
JH asserts the foundation movement is consistent with pre-existing long-term issues
that has caused differential movement of the structure. Further, JH concludes that
there is no evidence of gross long-term differential movement but rather aesthetic
repair to the cracks.
Having reviewed the photographs supplied in the report, I note the step cracking in
the brickwork is a re-occurrence of a previously repaired crack. Relevantly, the
previous JH reports also highlighted the opening up of previously repaired cracks in
the walls.
I accept that over the three floor surveys JH carried out, there has been minimal
change.
The complainants ’ experts argue the leaking pipe is the proximate cause
The complainant engaged a geotechnical and foundation engineer (CL) to assess the
damage. In his report CL says there is moderate to severe internal plaster cracks
where externally there is very little signs of distress.
In addressing the cause of the distress to the property, CL says the subject leak was
not present for any length of time as the distress would have been evident earlier.
Further, there is no distress to the external walls of the house. CL asserts the leak
has caused heave of the clay soil beneath the house resulting in the uneven floor and
crack plastering.
In his initial report, I note CL has not addressed any of the arguments or other
possible contributing factors to the claimed damage such as the over jacked stumps.
Further, the report does not include any survey levels.
CL provided a supplementary report. In his 2019 report, CL says:
A review of the level contour shows a slight variation in the levels around the
external edges of the building
The concrete paving around the external walls reduces the soil moisture changes
between the seasons
Given the age of the building it ’ s hard to accept that over a short period of time the
external walls of the building have suddenly settled almost uniformly as being the
cause of the internal cracking.
In addressing the pre-existing internal cracking to the property, CL says soil dry
settlement occurs over the first seven to ten years. Provided there is no water ingress
under the house the internal stumps will remain stable with only slight seasonal
movement round the perimeter possibly causing some stress to the external areas of
the house over the life of the building.
In addressing the unchanged survey levels for over two years, CL says following a
leaking pipe event, the water flows under gravity into many large existing cracks in the
Determination | Case number: 649319 Page 7 of 10
surface clays in and around the stumps. The heave following the saturation of the soil
will present itself within four to six weeks.
CL says following the repairs of the leak, it could take in this instance seven to ten
years for the soil to stabilise. I note the complainant’s second engineer ( YT) has
estimated a recovery period to be roughly 24 months. Relevant to the complaint, YT
conducted a desktop assessment rather than a site assessment.
In his report, YT says the building had been restumped 20 years prior to the subject
event. YT says the timber packing could be a response to settlement of the original
timber floor level.
YT says it was reported to him that the subfloor area has been saturated particularly
in the vicinity of the leak. YT says it is reasonable to expect the performance of a
building will not change rapidly unless an external factor becomes significant, that has
not been previously influencing the footing system.
YT agrees it is unusual there is no damage to the perimeter brickwork. Further, YT
agrees some of the damage is caused by the ongoing seasonal movement to the
footing system. Further YT agrees it is unusual the stumps have been installed close
to each other. YT elaborates that during the restumping the old stumps should be
removed and replaced with the new ones.
YT was unable to comment on the level of saturation to the subfloor as he is only
guided by the complainant’s supplied information. YT says it is not unusual for the
water to flow given the site is on a slope.
On balance, the pipe is not the proximate cause of the damage
Having reviewed the exchanged evidence, I accept the leaking pipe is not the
proximate cause of the damage. The leaking pipe might have exacerbated the
damage but is not the main cause of the damage. This is because:
SG, SL, JH and YT all agreed the over jacked stumps have attributed to the
claimed damage
whilst the pipe was a water mains pressurised pipe, the supplied photograph
shows a spray mist. It is not known how long the pipe had been leaking for. Cl
suggests the leak was not present for a length of time otherwise the distress would
have been evident at an early stage.
some of the previously repaired cracks have opened up
the topography of the site being on a slight slop from the front to the rear east and
the probability of the water flow with the slope
the sub floor slopes towards the middle of the house , where the over jacked
stumps are located
both SG and JH noted the soil appears to be dry. I note SG conducted the initial
assessment soon after the leak repairs
Determination | Case number: 649319 Page 8 of 10
conversely JH and CL suggested there could be deep water penetration into the
sub soil causing the disputed heave without any intrusive soil testing. Further, there
is no evidence of deep saturation given the duration of leak was not lengthy and it
was only a mist spray rather than a full disconnection. I accept the nature o f the
leak is a defining factor
SG says he has not observed heaving to the soil. In noting this, SG has not
provided any floor level survey
Given the nature of the damage, it was prudent for SG to undertake floor levels at this
point in time, to justify his findings. I also note CL at the time of its initial assessment
(prior to JH’s attendance) did not take any floor levels survey.
In saying this, I accept there are other contributing factors namely, the over jacked
stumps. Neither CL nor YT provided compelling evidence to rule out the over jacked
stumps as a contributing factor. Further, SG says the packing between bearers and
concrete stumps is not an incompressible material and as such has contributed to the
observed internal settlement. I note the complainant ’s engineer did not provide any
compelling evidence to exclude this from being a possible cause.
If I were to accept the water would have travelled down the sloped ground, I would
have expected to see the heave at the lowest point of the slope or possibly within
close proximity to the source of the leak.
There is no explanation as to why the wat er’s path would have s topped and would not
have travelled further down the slope. Further, JH says the different survey levels in
2017, did not show any heave in the proximity of the leak.
I note this point (where the stumps are located) remained the highest point through
the different floor level surveys in 2017, 2018 and 2019. CL suggests the soil recovery
(to the pre-leak level) could take a lengthy period of more than two year. Whilst he
proposed the deep penetration theory, I do not accept this argument given he advised
in his initial report the leak duration was not lengthy as suggested by SG and JH.
Further, I would have expected a slight decrease in the heave over the two years
period, however, this is not the case.
I accept in the absence of the subject water leak, the property would have moved to
some degree and sustained cracking damage as it is evident with the historic repairs.
I accept the pipe is not the proximate cause of the damage but rather over the years
the main bearers have been over supported and installed too high resulting in a peak
in the floor levels.
Determination | Case number: 649319 Page 9 of 10
The complainants’ arguments do not advance his position
In his submissions, the complainant says:
It is not plausible that the outer foundations of the house to sink evenly with no
major cracking to the exterior brickwork
the leak could have been going on for weeks or months as it was not a large leak
there were no intrusive assessments of the ground to check how saturated it was
following the SG assessment, the complainant installed a fan which ran for 10
hours per day to assist with the drying hence why the grounds seemed dry
he disag reed with JH’s assertion that the levels have not changed. This is evident
as doors are now closing which they were not a year ago
in 2019, he drilled a hole within close proximity of the heave and the sub floor was
soft at 250mm deep.
the damage occurred in a very short period of time, being two weeks. He initially
noticed the cracking in 2016.
I note the complainant has provided a number of videos showing the drilling process
and his analysis of the soil. Having reviewed these videos, I do not accept that they
advance the complainant’s position. Whilst the soil appears to be damp, I am unable
to conclude the proximity of the drilling site to the source of leak. Further, there is no
expert evidence to establish the level of soil saturation (if any) and how that is linked
to the subject event.
The complainant says the levels which JH undertook were incorrect. The complainant
has not provided any expert evidence or refute JHs’ floor levels. Whilst the
complainant has expressed his views, I am not satisfied he is as qualified as an
engineer to conclude or comment on building damage causation.
In attempting to establish the amount of escaped water, the complainant has provided
his own analysis for the water usage. I note his plumber’s report does not reflect a ny
findings regarding this issue. In his argument a nd analysis, the complainant says
during the subject period of leak, the usage was roughly 1198 litres of water per day
and approximately 46768 liters of water have escaped underneath the house.
I do not accept these calculations are accurate but rather they are speculation. This is
because, if I were to accept this proposal, SG would have noted saturated grounds
underneath the house which was not the case. Further, the floor level surveys would
have reflected the reduction in levels whilst the ground continues to dry.
The insurer is not required to increase its settlement
The complainant provided two quotes for the repairs of the property $94,800 and a
more detailed itemised one totalling $91,329.48.
The exchanged information shows the insurer has paid the complainant $40,127.92
as a gesture of good will. The insurer has based this figure on a quote for repairs by a
Determination | Case number: 649319 Page 10 of 10
builder, totalling $39,094.67. Further the insurer included two report fees incurred by
the complainant totalling $715 and $418.25.
In light of my findings above, even if I accept the pipe has contributed or exacerbated
the damage, the insurer has made the contribution of $40,127.92.
I consider the insurer’s settlement for the building damage was fair in the
circumstances. The insurer is not required to increase its settlement or take any
further action.
The insurer handled the claim reasonably overall
AFCA may award compensation for non-financial loss where a complainant has
suffered an unusual degree or extent of physical inconvenience, time taken to resolve
the situation or interference with the complainant’s expectation of enjoyment or peace
of mind. However, AFCA adopts a conservative approach to the award of
compensation for non-financial loss.
Whilst I note the initial loss occurred in 2016, I consider the delays were not caused
by any error of the insurer. I note the insurer had followed JH’s recommendation s
following each assessment by allowing a waiting period for the soil to recover. I note
the complainant’s engineer CL has concluded a waiting period was required for the
same reason. The insurer has engaged the relevant expertise to assess the claim.
I no te the insurer has promptly addressed all the complainants’ queries and sought
further input from its experts in addressing these queries.
Having reviewed the exchanged information, I am not satisfied that compensation is
appropriate in the circumstances of this claim and complaint.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.