Home / Suncorp Group / Determination 646557
Determination 646557
Subsidence cracking claim declined; $2,000 ex gratia payment maintained
Summary
The complainant claimed for ground-movement cracking to her house, which the insurer declined as not caused by an insured water leak. AFCA upheld the decline but maintained the insurer's $2,000 ex gratia payment.
The complainant did not prove the cracking was proximately caused by the leaking pipes; both engineers attributed it to tree-related drying and poor site drainage.
Issues
- Claim denial primary · not upheld“The insurer is entitled to decline the current claim.”
- Poor claim handling secondary · not upheld“I do not accept the available information establishes there was an unusual amount of time taken to resolve the situation.”
Subjects and remedies
home or building damagepay compensation
Related
All Suncorp Group determinations · Find similar determinations
Text of the determination
Determination
Case number 646557
Financial firm AAI Limited
Determination | Case number: 646557 Page 1 of 11
Case number: 646557 18 March 2020
1 Determination overview
1.1 Complaint
The complainant lodged a claim under her home and contents policy held with the
financial firm (insurer) in early March 2019, following the recent appearance of
cracking damage to her property.
The insurer says it is entitled to deny the claim because the damage did not arise
from an event the policy covers. In addition, the insurer says the damage is otherwise
excluded by the policy terms.
The complainant disputes the insurer’s decision and wants the insurer to pay the cost
of repairs, including underpinning works. The insurer does not consider the
underpinning works are appropriate.
The case manager provided the parties with a recommendation on the issues in
dispute. The recommendation was substantially in favour of the insurer.
As a recommendation was not accepted by the complainant, the complaint has been
referred to me for determination .
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
The available information does not establish on the balance of probabilities the
claimed damage was caused by an insured event. In these circumstances, the insurer
is entitled to decline the claim.
Is the complainant entitled to compensation?
The available information does not establish an entitlement to compensation under
the AFCA Rules. The insurer ’s offer of $2,000 was made ex-gratia in
acknowledgement of the complainant’s tenure. As the insurer accepted the
recommendation to pay $2,000, it is fair this offer is maintained.
1.3 Determination
This determination is substantially in favour of the insurer.
Should the complainant accept this determination, then within seven days of
notification of acceptance, the insurer is to pay to the complainant the ex gratia offer
of $2,000 (if it has not done so already). Otherwise, the insurer is no t required to take
any further action in relation to the claim or the complaint.
Determination | Case number: 646557 Page 2 of 11
2 Reasons for determination
I have decided this complaint based on what is fair in all the circumstances, having
regard to legal principles, applicable industry codes or guidance, good industry
practice and previous relevant determinations of AFCA or predecessor schemes
(which are not binding). I have considered all the material submitted by the parties,
both before and after the recommendation. I am satisfied that the documentation I
have relied on has been provided to both parties.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues considered
directly relevant to the outcome only.
The complainant is represented. For the sake of convenience and brevity, any
references in this determination to the complainant will include references to the
representative.
After the recommendation was rejected, the complainant made further submissions in
which she essentially reiterated her position. She also provided an invoice from a
plumber who inspected the storm water drains in the front of the property and found a
section of pipe which needed to be replaced.
2.1 Is the insurer entitled to decline the claim?
The policy covers certain listed events
The complainant must establish on the balance of probabilities she has suffered a
loss caused by an event to which the policy responds. This is known as a prima facie
claim.
Once so established, the onus shifts to the insurer to prove on the balance of
probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss.
On 4 March 2019, the complainant claimed cracking damage to the property around
the area of the kitchen and front porch.
After investigation, the insurer said it was entitled to decline the claim as the damage
was not caused by an event during the period of insurance to which the policy
responds. The insurer also says the cracking damage has been caused by earth
movement because of localised trees drying the soil and poor site drainage conditions
which causes are excluded from cover.
The complainant says the insurer is not making allowance for all the reports
submitted. She also challenges the insurer’s expert on the basis that he does not
accept underpinning is the correct method of repair.
Determination | Case number: 646557 Page 3 of 11
Relying on the leak detection report, the complainant says the leaking occurred
around the area of the damage.
The complainant also argues the reports do not unanimously agree on how the
damage was caused. The complainant says will the proximate cause of the damage
was the leaking which caused the soil movement.
Expert reports provided by the parties have been considered
The property has been examined by several experts. A summary of their findings is
set out in supporting section 3 of this determination.
The insurer’s assessor inspected the claimed damage and agreed there was cracking
on some outer veneer brick walls on one corner of the house, minor cracks in the
front around the porch and a partial collapse of the surface of the driveway. He
suspected there was a leak in an underground pipe.
The complainant arranged for the property to be inspected by a plumber on 21 March
2019. The plumber inspected the property and carried out CCTV camera inspections
of the stormwater line and sewer line.
The plumber found a break to the downpipe at the front left side of the house causing
moderate to large amounts of water to leak from the line during rain. There was also a
slow leak to the garden tap beside the downpipe causing water to continually run
down the brick wall.
In addition, the plumber found a break in the stormwater line below the grassed area
to the front left side of the property. He notes this is on the low side of the property.
He says the remainder of the stormwater line and sewer line were fault free. He noted
the sub floor had been wet but his testing found no water entered subfloor. Because
no major fault was found, and the plumber did not know what caused the damage, he
suggested the leaks be repaired (which was done) and the neighbour’s plumbing be
inspected.
The insurer arranged for an engineer to provide an opinion. He inspected the property
and reviewed the plumber’s report. The engineer made the same observation as the
plumber which was the land sloped from the back right-hand side of the property to
the front left-hand side of the property. The engineer noted uncapped soils/pebble
garden beds adjacent to the perimeter of the house and a tree removal near the
damaged area sometime after January 2019.
The engineer carried out hydrostatic floor levels which indicated the lowest area
within the house was in the south-eastern corner of the house near the kitchen (the
area of the cracking damage).
The engineer concluded the soils were moderately reactive.
Determination | Case number: 646557 Page 4 of 11
Based on his visual inspection and the pl umber’s report , the insurer’s engineer
concluded the damage is caused by the combined effects of trees located close to the
house and the lack of adequate surface water drainage (uncapped perimeter soils)
over a long period of time.
The engineer ruled out escaping liquid from the stormwater pipe as a cause of the
damage because the leaking pipe was downhill from the area of damage.
The engineer did not agree with the plumber that the neighbour ’ s plumbing should be
inspected. This was because the neighbour’s plumbing was on the side of the house
most distant from the leak and damage.
The complainant provided a report from a geotechnical engineer who inspected the
footings of the house near the damage. His testing confirmed the soil classification
identified by the insurer’s expert. The engineer agreed with the insurer’s engineer also
about the slope of the land. He noted to 5 to 6 metre trees near where the main
subsidence was identified.
The complainant ’ s engineer reviewed the insure r’s engineer report and came to the
same conclusion. That is, that the damage to the house was not caused by the
plumbing leaks. Rather, the engineer said:
…. the current damage is the result of localised tree related drying of the soil and
possibly excess wetting in certain situations as a result of a poor site drainage
conditions.
The complainant’s engineer (and the complainant) point out the small shrub
discussed in the insurer’s report is irrelevant but contends the combined effect of the
shrub together with other larger identified trees were enough to contribute to
additional drying of the soil close to the area of damage.
The complainant’s engineer agreed that the surface conditions along the north and
rear of the house were poor. The engineer said the fact that run-off had not been
observed flowing towards the house or under the house does not mean excessive
seepage was not reaching the house walls.
Unlike the insurer’s engineer, the complainant’ s engineer considered an appropriate
repair method was underpinning of the walls in the damaged area.
The complainant ’ s engineer also recommended the pathway along the north of the
house be concrete paved and a drainage pit be installed in the back lawn.
Complainant has not established claimed damage caused by an insured event
The complainant must establish the claimed cracking damage was caused by an
insured event. The policy covers damage caused by liquid leaking from a pipe.
Determination | Case number: 646557 Page 5 of 11
While the available information establishes there was a broken downpipe, leaking tap
and a broken underground stormwater pipe, I am not satisfied the available evidence
establishes this was the proximate (or the effective or dominant) cause of the claimed
damage.
Firstly, the leak detection expert is unable to identify the cause of damage. I accept
his suggestion to inspect the neighbour’s property is not viable because of the lie of
the land.
Secondly, I am satisfied both engineers essentially agree on the cause of the
damage. The complainant’s engineer is unambiguous about the cause of damage. He
says the damage is not caused by the identified plumbing leaks.
Both engineers identify the current damage is because of localised tree related drying
of the so il and poor site drainage conditions. I acknowledge the insurer’s engineer
may have incorrectly identified damage caused by a shrub near the claimed damage,
but the complainant ’ s engineer identified other trees which he says have contributed
to additional drying of the soil close to the area of damage.
Thirdly, all experts agree on the lie of the land. Having considered the lie of the land, I
do not accept the leaking pipes could have caused the damage because the leaking
pipes are beneath the area of claimed damage and water does not flow uphill.
Fourthly, although the complainant criticises the insurer’s engineer because of the
difference in opinion about the underpinning remedy, I do not consider this derogates
from the insurer’s engineer’s opinion about the cause of damage. Moreover, the
complainant ’ s own engineer agrees with the insurer’s engineer about the cause of
damage. The fact they disagree about the repair remedy is not relevant to the issue of
the proximate cause of the damage.
Having considered the available information and for the reasons stated I am not
satisfied the complainant has established the claimed current loss was caused by the
identified water leaks. In these circumstances, the complainant has not established a
prima facie claim.
The complainant contends the insurer should take heed of its own assessor who
considered the ground movement was possibly due to leaking underground pipes.
However, the assessor’s opinion is based on what is possible and not probable.
Furthe rmore, the assessor’s opinion was provided without the benefit of the
subsequent leak detection report and the engineers’ reports.
The insurer is entitled to decline the current claim
I am satisfied the engineers are qualified to comment on the issues in dispute. Both
engineers agree the proximate cause of the claimed current damage was not the
leaking pipes.
Determination | Case number: 646557 Page 6 of 11
As a prima facie claim is not established it is redundant to address the policy
exclusions which may apply.
I am satisfied the insurer is entitled to decline the current claim.
The complainant’s engineer inspected and undertook tests in mid May 2019. He
indicated there was damage to the front west corner of the house which could
develop by May 2020. The engineer indicated this damage could be directly
attributable to plumbing faults.
The available material does not establish if there is damage to the front west corner of
the house. This determination deals only with the claimed cracking damage which is
to the area proximate to the kitchen and front porch.
Should there be damage to the front west corner of the house, the complainant
should submit a further claim to the insurer for its assessment and consideration.
2.2 Is the complainant is entitled to compensation?
Insurer to maintain its ex gratia offer of $2,000
The complainant said the insurer’s claims management ca used severe stress and
anxiety and at aged 95 the complainant passed away due to heart failure.
The insurer acknowledged the concerns about claims handling and the timeliness of
actions. The insurer apologised the complainant’s expectation s had not been met.
Although the insurer continued to maintain it is entitled to decline the claim, and that
the claim was handled in a timely and professional manne r, the insurer offered the
complainant $2,000 compensation as appreciation of her tenure.
AFCA Rules allow the payment of compensation (capped at $5,000) for non-financial
loss. AFCA may decide an insurer should compensate a complainant for such loss
only where there has been an unusual amount of physical inconvenience, time taken
to resolve a situation, or interference with the complainant’s expectation of enjoyment
or peace of mind.
The available information shows the claim was made on 4 March 2019 and was
immediately investigated. The insurer’s engineer inspected on 16 April 2019 and the
claim was denied on 9 May 2019. A final decision was made on 7 June 2019. The
available information also establishes reasonably frequent attendances upon the
complainant.
While I accept an insurance claim is stressful, I do not accept the available
information establishes there was an unusual amount of time taken to resolve the
situation.
Determination | Case number: 646557 Page 7 of 11
In all the circumstances, I am not satisfied an award of compensation is warranted
under the AFCA Rules.
The insurer has made a compensation offer based on an appreciation of the
complainant’s tenure. Further, the insurer accepted the recommendation that it was
fair the insurer pay $2,000 compensation to the complainant on an ex gratia basis.
In these circumstances, although an award of compensation under the AFCA Rules is
not warranted, it is fair the insurer maintains its ex gratia offer to pay to the
complainant $2,000 compensation.
Determination | Case number: 646557 Page 8 of 11
3 Supporting information
3.1 AFCA Approach
It is an accepted principle of general insurance law that the insured bears the onus to
establish on the balance of probabilities that they have suffered a loss caused by an
event to which the policy responds. This is known as a prima facie claim. Once so
established, the onus shifts to the insurer to prove on the balance of probabilities that
an exclusion applies if it seeks to deny or limit its liability for the loss.
3.2 Case law and proximate cause
Case law establishes:
The proximate cause of the loss is the dominant or effective or operative cause of
the loss whether or not that be the last in time or the sole cause.
If there are several causes operating contemporaneously, each must be examined
for the qualities of reality, predominance and efficiency as the active, efficient
cause that sets a relevant chain of events in action. If one cause would have
caused the harm in any case, and the other would not have done so in the
absence of the first, the first is the proximate cause.
A common-sense approach is taken to determine proximate cause.
3.3 Key policy wording
Insured events
Escape of liquid – page 36
We cover
Loss or damage caused by liquid leaking, overflowing or bursting from any of the
following:
…
• any drain, fixed pipes, roof gutters or guttering a nd rainwater downpipes,
drainage and sewage systems (not forming part of a shower cubicle wall, floor or
base);
…
• water main, fire hydrant or water supply pipe .
Definitions
Glossary of important words and phrases – page 8
Event or incident means a single event, accident or occurrence which you did not
intend or expect to happen.
Determination | Case number: 646557 Page 9 of 11
3.4 Extracts from expert material
Record Key Points
C omplainant’s expert
(AL)
Leak Report
21 - 03 - 19
Visual inspection to property found a break to the down pipe at
front left side of house causing moderate to large amounts of
water to leak from line during rain .
Slow leak found to garden tap thread beside this down pipe
causing water to continually run - down brick wall .
CCTV camera inspection to PVC stormwater line found a br eak
below the grassed area to the front left side of the property .
which is the low side of the property.
Rest of storm water lines including suspended lines leak free.
Grassed area to the rear right side of house slopes towards the
house.
Soil to sub fl oor has clearly been wet in the past however soil
currently dry. Unknown if water can enter sub floor only during
torrential rain.
C omplainant’s expert (BF)
Plumber Tax invoice
25 - 09 - 2019
Used CCTV to inspect the existing stormwater drains at the front
of the property.
One section of pipe which needs to be dug up and replaced .
C omplainant’s expert (AL)
Email
03 - 10 - 19
There were no significant issues located w hich could have
caused water to enter the sub floor of the hous e.
It is unknown as to what has caused the damages hence the
recommendation to inspect neighbouring property’s plumbing.
I nsurer’s expert (IL)
Engineer Report
29 - 04 - 19
Dwelling constructed approximately twenty years ago (circa
1999).
About February 2019, c racks notice in south - eastern corner of
the home near the kitchen.
N atural topography of the land was found to be sloped down from
the north - east to the south - west.
Uncapped soils/pebble garden beds were next to all elevations of
the home and most of the building perimet er.
No soil testing but soil understood to be Class M. Class M is a
moderately reactive clay soil that, between wettish and dry soil
moisture conditions, can produce ground movement of bet ween
20mm - 40mm of vertical movement.
Aerial image on Nearmap as at 14 January 2019 show a tree
located directly adjacent to the sout h - eastern corner of the
kitchen. This tree was no longer present by the time of our
attendance in April 2019.
Hydrostatic floor levels were meas ured during inspection. F loor
levels show the lowest areas within the dwelling were in the
south - eastern corner of the dwelling in the vicinity of the kitchen.
L evels throughout the dwelling were otherwise relatively level,
and only slightly lower along the northern side of the dwell ing.
T otal maximum variation of 33mm was recorded throughout the
entire dwelling.
S eparation gap up to 10mm wide was sighted bet ween the
Determination | Case number: 646557 Page 10 of 11
Record Key Points
southern edge of the eastern kitchen window and the adjacent
brickwork.
Hairline crack was sighted to the east wall o f the kitchen.
F loor levels indicated that the lowest areas wit hin the dwelling
were in the sout h - eastern corner of the dwelling near the kitchen.
When structures are subject to an escape of water event
saturating the clay bearing strat a, damage and move ment are
generally non - uniform and occur local to the leak.
The breaks to the stormwater pipework were adjacent to the
south - western corner of the dwelling, downhill from the area of
movement and damage.
Given that no breaks were identified in the vicinit y of the damage,
we have ruled out escape of liquid from the stormwat er pipework
as a cause of damage.
C racking and movement to the dwelling is attributed to the
combined effects of trees located near the dwelling and lack of
adequate surface water drainage over the long term.
I nsurer’s expert (IL)
Additional Information
06 - 11 - 19
I nspection of neighbour’s plumbing is not relevant bec ause
damage and movement resulting from an escape of water event
is generally non - uniform and occur s locally.
A ll damage to the dwelling was recorded in the south - eastern
corner (at the opposite end of the dwelling), with no evidence of
localized movement in the northern side of the dwelling .
C omplainant’s expert (FE)
Engineer Report
04 - 06 - 19
The surface slope across this site was measured at
approximately 2 ⁰ fall towards the west.
Where normal soil moisture conditions prevail, this site is
classified as CLASS M in accordance with AS2870 – 2011 .
There are two Birch trees up to between 5m and 6m in height
located in proximity to the south side of this house.
After reviewing the report by IL and carrying out the relevant
testing on site, the conclusion is that the damage to this house is
not the result of the plumbing leaks that have occurred.
Although the small sh rub discussed in the IL’s report is irrelevant,
the combined effect of this toget her with the larger Birch trees are
considered enough to contribut e to additional drying of the soil
close to the area of damage.
Some surface drainage conditions along the no rth side and to the
rear of the house are considered poor.
The fact that runoff has not been observed flowing towards the
house or building up under the house does not mean that excess
seepage is not reaching the house walls.
C urrent damage is the result of localised tree relat ed drying of
the soil and possibly excess wetting in certain situations because
of the poor site drainage conditions.
The damage is such that underpinning of the house walls is
considered appropriate.
Determination | Case number: 646557 Page 11 of 11
Record Key Points
Complainant’s expert (FE)
Additional information
03 - 10 - 2019
Blocked and leaking stormwater has affected the front west
house corner. This is not where the current damage is located.
Usually a delay between fixin g a pipe and damage developing.
Damage may still develop at this corner that is attributable to the
leaking pipe .
3.5 Other relevant material considered and relied on
Parties’ submissions /emails and all attachments to all submissions/emails both
before and after the recommendation.
Parties’ expert reports and invoices.
Photographs and mud map.
Insurer’s claim file notes.
Correspondence between the parties.