Home / Allianz Australia / Determination 645056
Determination 645056
Partial denial of building damage claim for cracking caused by broken pipes
Summary
The complainants claimed under their residential building policy for cracking caused by broken pipes, and the insurer partly denied it as long-term foundation movement. AFCA found the proximate cause was the broken pipes and required the insurer to indemnify the full claim by repair or cash settlement, with interest if cash settled.
Proximate cause, meaning the dominant or operative cause and not necessarily the last in time, was the broken pipes, which is a covered water damage event.
Subjects and remedies
home or building damagepay claimpay interestrepair or rectify
Text of the determination
Determination
Case number 645056
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 645056 Page 1 of 6
Case number: 645056 27 April 2020
1 Determination overview
1.1 Complaint
The complainants hold a residential building insurance policy with the financial firm
(insurer).
The complainants lodged a claim on 29 October 2018 for cracking throughout the
property which occurred over the preceding months. Testing revealed several broken
pipes under the property, to which they attribute the damage.
The insurer partially accepted the claim and agreed to rectify cosmetic damage
adjacent to the leak. However, the insurer says other cracking and damage was
caused by long term foundational movement which the policy does not cover.
The complainants dispute this as they say all of the damage is due to the broken
pipes.
1.2 Issues and key findings
Can the insurer partially deny the claim?
The insurer is not entitled to deny the claim for cracking throughout the property. This
is because the exchanged information shows the proximate cause of the damage is
the broken pipes.
1.3 Determination
This determination is in favour of the complainant.
The insurer is to repair the property or provide a cash settlement in accordance with
the policy terms and as set out in section 2.1.
Determination | Case number: 645056 Page 2 of 6
2 Reasons for determination
I have decided this case based on what is fair in all the circumstances, having regard
to the relevant legal principles, good industry practice, codes of practice and previous
AFCA decisions (where relevant). I have considered all the material submitted by the
parties. I am satisfied that the documentation I have relied on has been provided to
both parties.
2.1 Can the insurer deny the claim for cracking throughout the property?
Complainants established a valid claim
The complainants have the onus to establish any loss or damage arises from an
event covered by the terms and conditions of the policy. This is known as a valid
(prima facie) claim.
The policy commenced on 11 March 2018 and is subject to certain terms, conditions
and exclusions. One of the events covered is damage or loss arising from Water or
other liquid damage . This responds in the following circumstances:
Loss or damage resulting directly from bursting, leaking, discharging or
overflowing of any … fixed pipes
There is no dispute that this insured event has occurred, and the insurer has partially
accepted the claim. The complaint is about whether all the cracking and damage
being claimed resulted directly from these broken pipes.
This would require the information to show the proximate cause of the damage is the
broken pipes. Proximate cause is the dominant, efficient or operative cause of the
loss. It is not required to be last in time or the sole cause. It is a question of fact that
depends on the circumstances of each case. It requires a common sense evaluation
of the evidence.
Engineers’ evidence
Both parties engaged engineers. I do not propose to summarise their reports in detail
given they have been exchanged.
The insurer's engineer (NP) concluded there has been ground movement since
construction and some recent movement likely occurred as a result of the damaged
plumbing systems. NP also said the floor tiling system was defective given the lack of
tile movement joints.
The complainant’s engineer (B) did not propose to do a detailed analysis as to the
cause of damage. B did measure the floor levels and noted that the highest levels
were in the vicinity of the wet areas. This possibly indicated subsoil heave conditions.
Determination | Case number: 645056 Page 3 of 6
B said that the movement is likely related to a combination of moisture changes in the
reactive clay being influenced by plumbing leaks, poor site and construction features.
Review of the available evidence
Having carefully considered the available information, I note the following.
Plumber BT identified several issues with the stormwater and sewer system. These
included the following:
a charged stormwater system on the right (southern) side of the property had a
large leak
the left (northern) side of the stormwater system also had a slow leak on the line
a puncture in the sewer line at the front right-hand corner (south-west)
another snapped bend about 1 metre downstream from the above break
snapped bend downstream of the junction for the main line / kitchen branch line
snapped 45-degree bend just after the inspection opening behind the main toilet
snapped junction on the laundry tub /ORG line
This showed an extensive amount of issues.
The complainants had obtained a pre -purchase inspection report around August
2014. It found one damaged tile in the kitchen, one split tile outside the bathroom
door, some cracks in the driveway, some concrete cracks in the ‘car accommodation’
and a ‘re - entrant crack to the ceiling sheet at the kitchen end’ . Of significance, the
report made the following comments:
Is there cracking to the Building Members?
No. None visible to the dwelling walls or foundations.
This supports the complainants’ position. They said they identified significant wall
fractures, broken tiles, doors not shutting, large gaps between brickwork and windows
in a short space of time. None of this was evident beforehand or when they
purchased the property.
NP, in reviewing the pre-purchase report, noted cracking damage to plasterboard
linings and repair of a joint. Also, that cosmetic damage can easily be concealed.
This is not persuasive. NP characterised the property as sustaining ‘significant global
movement issues’ with the broken pipes causing ‘slight localised worsening’. If this is
the case, then it is reasonable to expect that more substantive damage would have
been evident within eight years of construction. This is not the case as the pre-
purchase report found minor issues in the tiling and plasterboard and no evidence of
external damage or other issues that required investigation. Instead, the substantive
Determination | Case number: 645056 Page 4 of 6
cracking and movement issues mostly occurred in a short period and after numerous
issues were found in the stormwater and sewer system.
These factors undermine NP’s conclusions.
The floor levels also support the complainants’ position. A variance between 90mm
and 108mm in the floor were measured by the engineers with evidence of heave near
the charged stormwater leak. NP attributed this to a tilt in the footing system that has
occurred over a long period of time. It is difficult to accept this when it remained
asymptomatic of any substantive damage for such a long period of time.
I note that NP, when asked by the insurer, said some of this damage would have still
occurred. This is difficult to accept given no such extensive damage had occurred in
the first 10 years of its construction.
NP also says it is likely the pipes were broken by the movement. This is not
persuasive given the lack of evidence showing there has been substantive ground
movement affecting the property.
Proximate cause of the damage is the broken pipes
Given the above, I am persuaded that the proximate cause of all the movement and
cracking damage is due to the broken pipes.
The engineers both agree these pipes have affected the foundation.
NP’s reasons for saying this would have only resulted in minor damage is not
persuasive when you consider:
the pre-purchase report finding only minor and isolated issues to the tiles and
plasterboard and no evidence of external damage or other issues requiring further
investigation
the complain ants’ evidence that the serious movement issues started in a short
space of time
the extensive number of leaks identified on the property.
The floor levels also show that the foundation has been affected by the leaks.
Whilst I accept the property is built on highly reactive soil, it appears to have stayed
mostly asymptomatic of any issue for about 10 years. The main movement and
cracking issues have all manifested in a short period of time and when extensive
leaks were found.
I note NP identified poor workmanship in the tiling due to the lack of movement joints.
I am not persuaded their cracking was caused by this. Considering the floor levels
and the extensive issues in the property due to the foundation movement, it is more
likely their cracking was due to the broken pipes.
Determination | Case number: 645056 Page 5 of 6
Accordingly, after careful consideration of all the available information, I accept the
insurer is required to indemnify the complainants for this claim.
If the insurer decides to cash settle the claim, it must pay interest pursuant to section
57 of the Insurance Contracts Act 1984. Interest is payable from 23 May 2019, being
when the insurer denied the claim, until payment is made. Interest is not payable
though if the insurer cash settles the claim based on current repair rates.
Determination | Case number: 645056 Page 6 of 6
3 Supporting information
Record Key points
Pre - purcha se report (M)
12 August 2014
No signs of any significant foundation moveme nt noted
No visible cracking to the dwelling walls or foundations
No visual sign of apparent concealment (of defects) observed
Complainant’s expert (B)
Report
3 September 2018
We are of the opinion the movement is likely related to a
combination of moisture changes in the reactive clay being
influenced by plumbing lea ks (as noted in the BT Plumbing report),
poor site and construction features.
The maximum level difference rec orded ac ross the floor was
90mm
the highest levels were in the vicinity of the wet areas, possibly
indicating subsoil heave conditions (moisture driven expansion of
reactive clay soils) as the result of plumbing leaks or defects.
Insurer’s expert (S)
Report
6 December 2018
The recorded maximum level difference over the floor of the house
was 108mm
Some rec ent movement has also likely occurred as a res ult of the
damaged plumbing systems, which has caused some further
localised heaving along the southern elevation
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.