Home / Lloyd's / Determination 641965

Determination 641965

Storm damage claim to balcony denied

FirmLloyd's
Decided2020-01-03
ProductGeneral Insurance · Business / commercial
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant, represented by a solicitor, claimed under a commercial material damage policy for balcony damage after a storm in August 2017. AFCA found the storm was not the dominant cause, which was long-standing rot, decay and corrosion, and that the policy excludes those causes, so it ordered nothing.

The proximate cause of the loss was long-term deterioration and corrosion, which the policy expressly excludes.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Lloyd's determinations · Find similar determinations

Text of the determination

Determination Case number 641965 Financial firm Lloyd's Australia Limited Determination | Case number: 641965 Page 1 of 13 Case number: 641965 20 December 2019 1 Determination overview 1.1 Complaint The complainant is represented by his solicitor (AH). For simplicity, the determination will refer to both the complainant and AH as ‘the complainant’. The complainant holds a commercial material damage policy with the financial firm (insurer). The complainant lodged a claim for damage sustained to his balcony as a result of a storm event on 18 August 2017. The insurer assessed the claim and subsequently denied indemnity. In doing so, its engineer says the damage to the balcony is as a result of long term fatigue and structure dilapidation. The complainant disagrees and says the storm is the main proximate cause of the damage. Further, during the repairs of the damage, a further cause of the damage was discovered, being inadequate footings to support the column as a result of a dug- up pit by a telecommunications provider. 1.2 Issues and key findings Is the insurer entitled to deny the claim? Yes. This is because:  the storm is not the proximate cause of the damage but rather the long -standing rot, decay and corrosion damage to the balcony  the policy expressly excludes any physical loss, destruction or damage by rust, corrosion, wear and tear and gradual deterioration. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to deny the claim and is not required to take any further action. Determination | Case number: 641965 Page 2 of 13 2 Reasons for determination 2.1 Is the insurer entitled to deny the claim? The complainant carries the initial onus to establish any loss or damage arising from an event is covered by the terms and conditions of the policy. This is known as a valid claim. Once established and if the insurer seeks to deny the claim, the onus shifts to it. In such a case the insurer bears the onus to establish, on the balance of probabilities, it is entitled to:  rely upon a policy exclusion  otherwise deny the claim. The complainant’s policy provides cover in the event of any physical loss, destruction or damage subject to the policy’s exclusions. The complainant says a piece of verandah post fell in strong winds landing on a third party’s vehicle. The complainant’s building sustained severe damage which he attributes to the wind. Given the broad scope of cover provided under the policy, the panel is satisfied the complainant has established a valid claim for the damage sustained to the verandah. Accordingly, it falls to the insurer to demonstrate that the proximate cause, being the main dominant, causative and operative cause of the loss, is excluded under the policy or it is otherwise entitled to deny the claim. The balcony has been subject to long standing deterioration Two years prior to the loss, the complainant engaged an engineer (TK) to report on the possible causes of the balcony’s damage. In addressing the damage to the balcony structure, TK says in its report dated 11 April 2018 (based on previous inspections):  the perimeter decking boards and timber fascias have severe timber rot  the western end of the timber floor bearers has severe rot  the existing balcony level cast iron posts have rusted and have inadequate connections to the balcony  ground floor steel posts have severe rust at the top and bottom connection plates  one pad footing has settled  it appears that one ground floor post has been hit by a car. Determination | Case number: 641965 Page 3 of 13 TK attributed the observed rotten timber to the ongoing exposure to driven rain entering the balcony. In addressing the causation of the cast iron rust, TK says the exposure to weather over a long period of time has resulted in the paint wearing off and rusting. Further, the cast iron posts have lost their connection to the balcony floor structure. TK says most of the base connection has separated where the decking boards have rotted through. In addressing the subsided footing, TK says the subsidence is adjacent to the telecommunication provider’s pit which was likely installed after the original footings were constructed. Further the footing is also at the location of a down pipe storm water from the balcony discharging onto the street. TK opines the footing appears to be inadequate in size based on the current standards. Further, TK says it is likely a combination of the service pit installation, down pipe and footing size which have contributed to the settlement. TK originally inspected the property on 29 January 2015, which predates the subject event. Relevant to the complaint, the policy was incepted on 31 March 2016. There is no evidence the complainant has addressed any of the damage and issues which TK identified in his reports. Wind is not the proximate cause of the damage Following the claim’s lodgement, the insurer engaged an engineer (CD) to assess the cause and the extent of the damage. In his report, CD notes:  severely dilapidated timber floor boards. Nailed connections are protruding from the decking  the support post on the southeast corner of the balcony has negligible connection at the base. Rotted timber decking around the base screw fixing which is no longer embedded into the timber flooring  corrosion to the decorative infill panel and extensive corrosion to the base infill railing  nail fixings have popped out of the timber floorboards and are severely corroded  the base of the column support has completely rotted out such that the column is not physically connected to the timber floorboards. Corrosion debris is seen in the cavity beneath the column  longstanding rot and decay of the timber floorboards  split cast iron column where corrosion is evident to the split surface. CD argues the maximum speed wind recorded on the day of the loss (72km/h), is not the highest in the year. CD says on 22 February 2017 the wind speed was 80km/h. Determination | Case number: 641965 Page 4 of 13 Having the blinds lowered in the western and southern end of the balcony, the SWS wind would have incurred the greatest load on the subject balcony. CD says the lowered position of the blinds has increased the solidity of the structure and therefore increased the wind loading acting on the structure. CD is unable to comment on whether the balcony is compliant with the current building standard given the age of the balcony is unknown. In noting this, CD says the damaged observed to the balcony would not have been as a result on a one-off storm event with a maximum wind speed of just over 70 km/h. CD argues the subject balcony is considered to have been in a dilapidated state prior to the reported date of loss. The observed damage being movement damage, timber decay and iron corrosion are long term and pre-existing. Further, the connections of the balcony members are considered to have been in a compromised state and susceptible to movement prior to the event. CD provided a number of google images from 2010 for the subject structure. CD says the photos depicts several structural damage such as corrosion to the column, cracking of the timber and movement of the balcony structure. CD argues the balcony may have suffered further damage during the claimed event, however, the storm is not considered to be the proximate cause of the damage to the structure. CD argues the structural capacity of the balcony structure has been adversely affected by the long-term rot and decay (predominantly the timber decking) which has compromised the structural capacity of the connections. Particularly at the base of the column making these connections highly susceptible to movement. Similarly, the historic pre-existing cracking and corrosion damage evident to the cast iron column and connections is considered to have significantly reduced its capacity. CD says the balcony structure was structurally unstable prior to the event. CD concludes the storm may have caused further damage to the balcony, however, is not considered to be the proximate cause of the damage. In CD’s opinion, the proximate cause of the damage is the long-term dilapidation and fatigue. CD says the damage to the balcony is partially due to the poor human judgement by lowering the blinds which were secured to brittle cast iron column supports. The panel notes, the complainant has not provided any expert reports to refute CD’s findings. The panel accepts the subject wind is not the proximate cause of the damage. The complainants’ arguments do not advance his position Having reviewed both TK’s’ reports, the panel is not satisfied these reports either assist the complainant nor advance his position. This is because: Determination | Case number: 641965 Page 5 of 13  this causation and the structure settlement damage was noted by TK prior to the claimed event  there is no evidence the complainant has addressed the reported damage in TK’s initial report  the pit installation and subsequent settlement predates the policy inception. The exchanged information does not establish the exact date of the pit installation. However, the footing settlement associated with the excavated pit was noted in 2015. It is reasonable to conclude the pit installation predates the policy inception. The complainant says the insurer inspected the property prior to the policy inception. The insurer says the complainant was aware of the condition of the property and the works required to be carried out hence the restricted use of the area being the balcony. The panel notes the insurer is not arguing or seeking to rely on any non- disclosure breaches (if any) by the complainant. The complainant says:  the normal upkeep does not apply to the subject property being heritage listed  to avoid damage and further deterioration, he restricted access to the subject area and being closed to the public for years  he provided a condition report along with photographs to the insurer prior to the policy inception  the deteriorated condition of the property since 2010 has not changed and this is evident in the subsequent assessments  the only exception is the storm damage. The complainant says given the heritage nature of the property he was unable to carry out any works and restricting the area was the most reasonable solution which was successful until the storm event. In addressing the wind damage, the complainant says the weather station is 11kms away and not 8kms as mentioned by CD. Further, there are differences in the surroundings at the two locations, one being an open area and one being in an area which could create wind tunnels. The complainant has not provided any evidence to substantiate this assertion. Further, the complainant says previous storms might have c ontributed to the structural integrity of the building which is consistent with CD’s conclusion. The complainant says the age on the balcony is unknown and therefore the applicable building standard is also unknown. The complainant argues there is no evidence that the storm was not significant enough to cause damage or the structure was not compliant with the relevant code. The panel accepts the exchanged information does not ascertain the relevant building code. However, the panel accepts Determination | Case number: 641965 Page 6 of 13 the complainant was aware that the balcony was not compliant with the current standards in light of TK’s pre -loss report. The complainant says he was not aware the pit installation and the storm water seepage into the ground caused the foundational damage. Whilst the panel accepts the complainant was not aware of the causation to the settlement and subsidence, the pan el does not consider the insurer’s liability extends to cover this damage. This damage occurred prior to the policy inception. The complainant argues the wear and tear issues identified are superficial in nature and could not have resulted on the claimed damage. The panel does not accept this argument. It is clearly evidence from TK’s and CD’s respective reports the damage sustained to the balcony prior to the storm event was so severe to the point which prompted the complainant to restrict public access for safety concerns. Conversely, the panel considers the identified wear and tear issues to be significant in light of TK’s and CD’s reports. The complainant has not provided any expert evidence to refute CD’s findings. The panel does not accept the complai nant’s argument that the deteriorated state of the balcony had no relevance to the performance of the building during the storm event. The complainant says further assessment by the engineers and builders engaged for the repairs found there was no severe timber rot and the original report could not have made such an assessment without the removal of the decking board. The complainant has not provided any evidence to substantiate his assertion. The panel does not accept this argument given both TK and CD comments on the severity of the rotting and decaying. The complainant asserts that following the removal of the steel posts rust was mainly to the surface and the posts were structurally sound. Further upon carrying out repairs to the veranda and balcony the structure was at nowhere near the level of dilapidation that the engineers have reported. Unfortunately, the complainant has not provided expert material to support his position. A position which is directly challenged by TK and CD. The insurer is entitled to deny the claim Having carefully considered the exchanged information and parties arguments, the panel is not satisfied the complainant has established that the storm is the proximate cause of the damage. There is no dispute the insurer was aware the insured property is heritage listed. Further, the panel accepts the heritage nature of the building caused difficulties to the ongoing maintenance of the property as outlined by the complainant. Determination | Case number: 641965 Page 7 of 13 In noting that, the panel considered the loss in light of the terms and conditions of the policy. The panel considers the storm was sudden and unexpected from the complainant’s point of view. Further the panel accepts the storm may have exacerbated the degree of damage to the already deteriorated structure. Further, the panel accepts the building performed poorly when impacted by the wind due to its deteriorated structure. It is evident the balcony structure was not adequately connected to the posts. This is evident in TK’s pre -loss report. The panel accepts CD’s fi nding and finds his report logical and persuasive. Further, his report is consistent with TK’s report commissioned in 2015. The panel notes at the time of CD’s inspection and subsequent reporting, TK’s report was not available to him. The panel accepts the subject balcony structure was in a dilapidated state prior to the claimed event which would have required the claimed substantial repair works. TKs’ pre -loss findings conclude the balcony structure has severely decayed and corroded. The panel considers that had the balcony been maintained and of good repairs at the time of the event, further damage would not have occurred. The panel accepts that substantial repairs were required to address the long-standing timber decay and corroded posts prior to the claimed event as early as 2010, based on the google images supplied by CD. It is evident the complainant was aware of the deteriorated state of the balcony based on TK’s causation report. There is no evidence to suggest the complainant took any reasonable steps to address noted damage and mitigate further losses. The panel does not accept restricting public access was adequate to mitigate further losses. The balcony was out of operation for any commercial purposes two years prior to when TK reported that the balcony posts were rusted and had inadequate connections to the balcony. The panel accepts the storm may have exacerbated the damage to the already deteriorated and fatigued structure. However, the panel is satisfied that the storm is not the dominant, operative and proximate cause of the damage but rather the deterioration, decaying and corrosion which the policy clearly excludes. The policy clearly and unequivocally excludes any loss or damage through rus t or oxidation, corrosion, wear and tear, gradual deterioration or developing flaws, normal upkeep or making good The panel is satisfied the insurer is entitled to deny the claim and is not required to take any further action. Determination | Case number: 641965 Page 8 of 13 3 Supporting information 3.1 Policy Wording SECTION ONE MATERIAL LOSS OR DAMAGE THE INDEMNITY In the event of any physical loss, destruction or damage (hereinafter in Section 1 referred to as ‘damage’ with ‘damaged’ having a corresponding meaning) not otherwise excluded happening at the situation to the Property Complainant described in Section 1 We will, subject to the provisions of this Policy including the limitation on Our liability, indemnify You in accordance with the applicable Basis of Settlement. … EXCLUSIONS APPLICABLE TO ALL SECTIONS PROPERTY EXCLUSIONS This Policy does not cover physical loss, destruction of or damage to the following property or loss under Section 2 resulting therefrom: …. PERILS EXCLUSIONS We shall not be liable under Sections 1 and/or 2 in respect of: …. 4. Physical loss, destruction or damage occasioned by or happening through: a) moths, termites or other insects, vermin, rust or oxidation, mildew, mould, contamination or pollution, wet or dry rot, corrosion, change of colour, dampness of atmosphere or other variations in temperature, evaporation, disease, inherent vice or Determination | Case number: 641965 Page 9 of 13 latent defect, loss of weight, change in flavour texture or finish, smut or smoke from industrial operations (other than sudden and unforeseen damage resulting therefrom); b) wear and tear, fading, scratching or marring, gradual deterioration or developing flaws, normal upkeep or making good; 3.2 Key documents Record Key points Complainant’s engineer (TK) 30 - 01 - 2015  The central post (4 th in from East) appears to have dropped. The associated balcony floor and roof beams connected to the post have noticeable sag to them.  A storm water down pipe is connected to this post discharging roof stormwat er to the street  It is likely (although diffic ult to tell due top paving restricting inspection) that overtime, stormwater discharge from the down pipe has perc olated through the sandy soils surrounding the post footing leading to minor settlement of the footing  It is difficult to comment on whether f urther settlement of the footing is likely to occur without knowing details of the foundation soils and footing size  Corrosion is evident to steel plates connecting the tops of the columns to floor beams  The steel plat es are exposed to constant weat her and the paint coating does not appear to be adequate in providing corrosion protection  Given the current condition of the plates, we would recommend replacement or extensive treatment to slow down/prevent furt her corrosion from occurring  The edges of the deck ing has severe timber rot  The rot appears to be concentrated around upper level posts bases  The unprotected hardwood decking will likely continue to rot if left untreated  Of significant concerns is the detached base of one of the upper level posts supporting the balcony roof  Although difficult to see from pictures, the base of the post is no longer supported by the floor beam below  The post can easily be removed when leaned on and sways significantly when leaning on the existing handrails  We conclud e that the current condition of the balcony posts and framing is in poor condition  Due to the lack of support to part of the upper level roof and balustrade, we recommend that this area is not used by the public or large crowds until repaired. Determination | Case number: 641965 Page 10 of 13 Record Key points Insurer’s e ngineer (CD ) 26 - 09 - 2017  The original building was constructed in 1870 and is heritage listed.  An extension to the original building occurred which includes the balcony.  The complainant installed café blinds to the balcony 10 years ago.  The complainant says an engineer inspected the balcony 2 years ago and noted rotted timber decking on the balcony.  The balcony has been out of operation for commercial purposes two years prior.  The maximum wind speed was recorded at 72km/h on 18 August 2017, 74 km/h on 10 August 2017 and 74 km/h on 16 August 2017.  The highest wind gust of the year was 22 February 2017 at 80 km/h.  Of particular importance in the case is the direction the wind was coming from as the insured has claimed the wind acted on the blinds in a manne r similar to that of a sail.  The wind would have incurred the greatest wind load on the balcony.  The lowered position of the blinds increased the solidity of the structure and therefore increased the wind loading acting on the structure.  The failure of the cast iron column support is due to a combination of pre - existing damage (already dilapidated structural column member) and due to insured securing blinds directly to the brittle cast iron column supports with rope, causing the member to fail when subjecte d to significant wind loading.  The wind speed 72 km/h is significantly lower than the design wind speeds which current buildings are designed for.  The structural observed damage to the balcony would not have been the res ult of a one - off storm event with a maximum wind speed of just over 70 km/h.  The balcony has been in a dilapidated state prior to the reported loss.  The majority of the damage has been caused by long term rot and decay and pre - existing movement related damage to the cash iron members.  The co nnections of the balcony members are therefore considered to have been in a compromised state and susceptible to movement prior to the event.  Desktop investigations with the use of Google Maps Street View imagery from as early as January 2010 depicts the s ubject balcony with several structural defects, such as corrosion to column supports, cracking of timber elements and movement of the balcony structure.  The storm event may have precipitated further damage to column supports and caused further movement of the balcony structure.  The subject balcony was structurally unstable prior to the 'Event' and posed a credible risk to the health and safely to whoever used Determination | Case number: 641965 Page 11 of 13 Record Key points the balcony prior to the 'Event.  T he fixing of cafe blinds to the cast iron column supports with th e use of rope by the Insured enhanced the damage potential to the structure, particularly under wind load conditions such as those experienced on the date of loss (which were conducive to causing most damage to the subject structure).  T he failure of the ca st iron column support is partly due to the Insured securing the blinds to the brittle cast iron column supports with rope, but mostly due to pre - existing, longstanding damages to the balcony structure. Complainant’s engineer (TK) 04 - 2018  TK has been engaged to provide comments on the possible causes of the current deterioration of the existing balcony.  The perimet er decking boards and timber fascias have severe rot.  The western end of the timber floor bearers has severe timber rot.  Existing balcony le vel cast iron posts have rusted and have inadequate connections to the balcony floor.  Ground floor steel posts have severe rust at top and bottom connection plates.  One pad footing in particular has settled.  It appears that one ground floor post has previo usly been hit by a car.  Timber rot observed in the timber decking boards and bearers and fascias is likely due to ongoing exposure to driven rain entering the balcony area and falling towards the ends of the decking.  Any surface water would likely penetrat e into the bearers over time resulting in timber rot.  Existing painted cast iron posts have been exposed to the weather for a long period of time resulting in some of the paint wearing off and rusting the exposed iron.  The cast iron posts have lost their c onnection to the balcony floor structure.  The previous connection consisted of two screws to the decking boards which would not comply with current standards.  Most of the base connections have separated where the decking boards have rotted through.  Existin g ground floor painted circular hollow section posts have rusted at connection plates which is typical for painted steel exposed to weat her over prolonged periods that have been inadequate paint protective coatings.  The footing that has subsided is adjacent to a Telstra service pit likely installed after the original footings were constructed.  The footing is also at the location of a down pipe collection stormwat er from the balcony roof and discharging to the street.  The footing was exposed by the builder and appeared to be inadequate in size based on current standards.  It is likely a combination of the service pit installation, down pipe and footing size that has contributed to the settlement.  It is likely at some p oint a vehicle has reversed or driven into one Determination | Case number: 641965 Page 12 of 13 Record Key points of the posts whilst attempting to park on the street outside the balcony. The damage has likely reduced the structural capacity of this post. Complainant’s engineer ( TK ) Report 29 - 04 - 2019  Pit removal and pre paration for new footing inspection.  The pit has been excavated and removed prior to TK’s arrival.  It appears during the construction and installation of the pit, the existing footing at the balcony column was cut to accommodate the pit.  The existing footi ng was cut to within 50 mm of the column and obvious settling was apparent at the rear of the column closest to the cut.  A combination of the inadequate footing and storm water seepage into the foundation soil is likely to be the cause of the settled colum n.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.