Home / Suncorp Group / Determination 639399

Determination 639399

Declined home building claim for cracking and movement damage

FirmSuncorp Group
Decided2020-04-02
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

Complainant claimed under home building insurance for cracking and movement damage attributed to water leaks. The insurer declined under the ground movement exclusion, and AFCA found the insurer entitled to decline.

Once a valid claim is shown the insurer must prove an exclusion; the dominant (proximate) cause of damage was ongoing ground movement, which the policy excludes.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 639399 Financial firm AAI Limited Determination | Case number: 639399 Page 2 of 13 Case number: 639399 23 March 2020 1 Determination overview 1.1 Complaint The complainant lodged a claim under his home building insurance policy with the financial firm (insurer) for movement and cracking damage believed to have been caused by water from a burst/leaking pipe at the neighbouring property. The complainant subsequently advised the insurer that a water leak from his water tank overflow pipe was also a likely cause of damage. After obtaining expert reports, the insurer maintained its decision to decline the claim. It says the proximate cause of damage was several factors excluded from cover under the policy terms, rather than an escape of liquid event. The complainant disagrees with the insurer’s decision and seeks a review. The case manager provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the insurer. The insurer accepted the recommendation, but it was not accepted by the complainant . In the circumstances, the complaint has been referred to me for determination . 1.2 Issues and key findings Can the insurer decline the claim? The insurer is entitled to decline the claim because:  the policy covers damage caused by the escape of liquid  on balance, the evidence establishes the proximate cause of damage is ground movement, not escape of liquid  the policy excludes damage caused by ground movement. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to take any further action. Determination | Case number: 639399 Page 3 of 13 2 Reasons for decision I have decided this complaint based on what is fair in all the circumstances, having regard to legal principles, applicable industry codes or guidance, good industry practice and previous relevant determinations of AFCA or predecessor schemes (which are not binding). I have considered all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. After the recommendation was rejected, the complainant made further submissions. 2.1 Can the insurer decline the claim? Complainant has established a valid claim The complainant is required to show, on the balance of probabilities, he suffered a loss caused by a risk insured against under the policy. This is known as a valid ( prima facie ) claim. If the complainant establishes a valid claim, then the onus shifts to the insurer to show, on the balance of probabilities, it is entitled to rely on an exclusion under the policy to deny the claim. The complainant’s policy provides cover for insured events, subject to conditions and exclusions. The policy will only cover the claimed property damage if it was caused by one of the insured events. Insured events in the policy include escape of liquid . There is no dispute water escaped from:  a neighbour’s reticulated garden watering system in close proximity to the complainant’s home in 2016 (L1), and  the complainant’s water tank due to a broken overflow pipe in August 2017 (L2). The insurer appointed engineers SM, J, M and S to inspect the p roperty and report on the cause and extent of damage at different points in the claim process. SM and J concluded L1 likely resulted in the damage, while M concluded the cause of damage was L2. I am satisfied these reports sufficiently show the damage could have been caused by the escape of liquid events identified. The complainant has therefore established a valid claim. Policy cover for escape of liquid is subject to conditions and exclusions General insurance policies do not cover every eventuality. The conditions of cover, and extent of an insurer’s liability is governed by applicable policy terms. Determination | Case number: 639399 Page 4 of 13 The complainant’s policy provides cover for loss or damage caused by listed events or risks, subject to the conditions and exclusions set out in the policy documents (certificate of insurance and product disclosure statement (PDS) together). The insurer says even if the complainant establishes a valid claim, policy exclusions under the escape of liquid event, and general exclusions for damage due to ground movement apply to defeat the claim. The relevant policy terms are set out in section 3.2 of this recommendation. Damage caused by escape of liquid from certain items excluded from cover There is no dispute water escaped from the complainant’s neighbour’s agricultural reticulated watering system onto his premises in or around October 2016. The insurer instructed engineers SM and J to report on whether L1 resulted in the cracking and gaps in wall, doors etc (claimed damage). SM and J inspected the property on 6 July & 12 November 2018 respectively. In their reports they found evidence of flooding and subsidence of footing/stumps in the sub -floor. They both concluded L1 caused ground movement and the claimed damage. After reviewing the reports, the insurer declined the claim saying policy coverage for loss/damage caused by escape of liquid does not extend to:  leaks from agricultural pipes;  loss or damage caused by liquid from a watering system or hose. I have read the relevant terms and I am satisfied it is clear and unambiguous that damage caused by water escaping from the above sources is not be covered under the policy. The complainant says L2 is more likely the cause of damage The complainant submits that water leaking from a storage tank likely caused the damage. He says:  the leak was discovered by his friend in August 2017  he first noticed cracking and gaps in walls/flooring about a month after the water tank leak was identified and repaired (prior to installation of a large gun safe on 17 September 2017). The damage has continued to worsen since then  weather information for August and September 2017 (the period of the leak and immediately following) shows average temperatures of 15.3 and 20.3 degrees Celsius respectively. This means more time would have been required for the subfloor to dry- out. Experts disagree on whether water tank leak resulted in the claimed damage The insurer’s engineer’s (J) reports included that the complainant informed h im of L2, however J did not consider L2 caused sub-floor moisture changes and the claimed Determination | Case number: 639399 Page 5 of 13 damage. The insurer subsequently appointed engineer (M) to report on whether L2 resulted in the claimed damage. M inspected the property on 26 February 2019 and concluded in its report that the cause of damage is L2. The insurer says it needed clarification due to inconsistencies and conflicting conclusions in J and M’s reports. As such, it says it engaged engineer (S). After inspecting the property, S concluded that neither L1 nor L2 caused the damage. Instead, it concluded the main cause of damage was ongoing ground movement. Consequently, the insurer maintained its decline of the claim on the basis the damage was due to ongoing ground/earth movement which is excluded from cover under the policy (see section 3.2 for relevant wording). The complainant disagreed with S’s finding and the insurer’s decision and appointed engineer (P) to report on the damage. A summary of th e parties’ expert’s opinions on the cause of damage (cracking/gaps) to the insured building is provided in section 3.3 of this recommendation. It is necessary to establish the proximate cause of damage There is no dispute that if L1 caused the damage, it would be excluded from cover. The insurer maintains L2 was not the proximate cause of damage. It says ground movement (which is a general exclusion under the policy) was the cause of damage. When considering whether the exclusion applies to defeat the claim, it is appropriate to determine the proximate cause of the loss. It is established law that the proximate cause of loss is the dominant or effective or operative cause, regardless of whether it is the last in time or the sole cause. This means that even if an escape of liquid was the last event to cause the claimed damage, it is not necessarily the proximate or dominant cause of the loss. To determine the dominant cause, each cause must be examined for the qualities of reality, predominance and efficiency as the active cause. If one cause (ground movement) would have caused the harm in any case, and the other (escape of liquid) would not have done so in the absence of the first, the first is the proximate cause. Evidence establishes the proximate cause of damage is ground movement S concluded neither L1 nor L2 caused the observed movement and cracking. It says the predominant cause of damage is the “ongoing/long term building movement caused by footings founded in highly reactive clay foundations, subject to Determination | Case number: 639399 Page 6 of 13 seasonal/climatic moisture changes”, significantly exacerbated by the nearby trees and subfloor drying. Among other things, S considered:  H-D soil type at the premises generally experiences significant volumetric changes with relative changes in moisture content (increase in moisture causes swell/heave and decrease results in shrink & settlement of the footings). As such, abnormal soil moisture conditions would result in increased magnitude of the surface movements (heave/settlement) and consequently increased building movement.  Leak from the water tank (located on the south-west side of property) would have resulted in increased moisture contents of the deeper supporting foundation clays, in its vicinity, caused initial heave, then after approximately 6-12 months drying resulted in “partial rebound lowering of the raised floors as the clay foundations dried out and reached their moisture equilibrium point”.  Had the water tank leak resulted in abnormal moisture increase (considering the soil type and conditions), it would have taken around 6 -12 months of swelling/drying for any damage from the leak to become evident. This does not align with the complainant’s account of when the damage started to show.  Observation and floor level survey shows: > damage was not concentrated in any one area or within close proximity of the leak (which would be consistent with the leak being the sole cause) > increasing settlement towards the location of nearby trees > no evidence of locally raised floor levels in the vicinity of the water tank leak, or concentrated localised damage to plasterboard walls around the southwest of the building. The complainant obtained and provided a report from engineer (P) to support his position that L2 was sufficient to cause the claimed damage. In its report, P refers to (and agrees with) points in the insurer’s reports saying: varying subfloor soil moisture conditions, growth of trees near the house, and stump footings on highly reactive soil have resulted in shrinkage and swelling of founding soils and settlement of stumps, resulting in floor/wall gaps, and plasterboard cracking. However, P concludes the “most likely” cause of the extensive underfloor wetting was water discharged from the broken water tank overflow pipe, “supplemented by water from other sources”. I have carefully reviewed all reports (including colour photographs) provided to determine, whether they support a conclusion, on balance, that water overflowing from the broken rainwater tank overflow pipe was the dominant or operative cause of the damage. Determination | Case number: 639399 Page 7 of 13 While I accept all reports provided have been issued by experts qualified to report on the cause of damage, I find the S’ report most persuasive because it reaches its conclusions following a detailed analysis of all available information and its own observations. I agree that the available information does not support a conclusion that L2 caused the claimed damage. I have considered:  S’s analysis of the heave/settlement process following abnormal increase in soil moisture content, and that this process generally takes around 6 to 12 months to occur and result in movement/cracking damage.  The complainant reported noticing the claimed damage one month after L2 repairs. This is inconsistent with L2 being the cause of damage considering S’s analysis above.  The evidence of general cracking/gaps through the home rather than a concentration of damage in the vicinity of the leak. I am not satisfied L2 was the dominant cause for the ground movement, or that water from other sources, seasonal moisture changes and impact of trees would not have resulted in earth movement and the claimed damage, in the absence of the leak. The expert reports all show the mechanism for damage was ground movement. However, I am satisfied that ongoing ground movement, rather than ground movement caused by L1 or L2 resulted in the claimed damage. Damage caused by, arising from or involving ground/earth movement is excluded from cover under the policy. Therefore, the insurer is entitled to decline the claim. Determination | Case number: 639399 Page 8 of 13 3 Supporting information 3.1 AFCA approach It is an accepted principle of general insurance law that an insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. 3.2 Relevant policy terms Page 22 of the PDS - Escape of liquid We cover We do not cover Loss or damage to the building caused by liquid leaking, overflowing or bursting from any of the following: any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems … fixed tanks; ... … leaks from agricultural pipes; … loss or damage caused by liquid from a watering system or hose; What we do not cover - general exclusions You are not covered under any section of your policy for damage, loss, cost or legal liability that is caused by, arises from or involve2s: … Ground movement erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover landslide or subsidence that is specifically covered under the following insured events: • ‘Storm’; • ‘Flood’ (but only if you have cover for insured event ‘Flood’); • ‘Earthquake and Tsunami’; • ‘Explosion’. Pages 35-37 of the PDS Determination | Case number: 639399 Page 9 of 13 3.3 Expert reports Report Key points Insurer’s building asse ssment report (R) 22 - 06 - 18  observed subsidence  has engaged engineer to inspect and report  insured advised R at the time that subsidence has been occurring prior to a gun safe (observed to be located in the middle of the home) being installed Insurer’s engineer report (SM) 22 - 06 - 18  site in spection on 16 July 2018 following R(above) instructions  complainant reported neighbour’s “reticulated garden water pipe” burst and caused water to flood the subfloor of his home  staining of stumps, surface cracking and some water ruts evidences that water had been beneat h the home  stumps on west side and some cent ral stumps “had dropped due to water saturating the ground”  subsidence in stumps has led to gaps between walls and flooring  concluded that 8 - 12 stumps subsided due to a water leak from the neighbour’s reticulated garden water pipe and led to internal building cracking and gaps Insurer’s engineer report (J) 21 - 11 - 2018 & 19 - 12 - 2018  site inspection on 12 November 2018  insured advised movement first noticed after August 2017 incident, and ha s continued. Also says water tank overflow in 2018 has caused movement and one of these incidents caused movement.  Observed: o separation in the cladding in the western wall near the kitchen and damage to the bottom board of the cladding. o crack in the carport slab at the south - western corner of the dwelling > subfloor soil surface showing evidence of saturation during a “flood incident ”. o two downpipes were not connected to a stormwat er line  hydraulic level survey undertak en and flooring dro pped significantly on the western side, localised subsidence was evident in the footing under the kitchen, and “ contours spread out from this location as is typically seen when an area is affected by an escape of liquid”.  evidence of soil saturation aroun d neighbour’s tap causing foundation movement in reactive clay soil. Foundation movement “has caused subsidence in the footings of the concrete stumps”  “evidence indicat es that the foundation movement has occurred as a result of the escape of liquid from t he neighbouring property”  considered the complainant’s argument and information provided that the leak from the water tank caused the damage. Does not accept evidence supports this conclusion Insurer’s engineer report (M) 6 - 3 - 2019  site inspection on 26 February 2019  observation:  ground surface falls towards the west  movement in weatherboard material consistence with subsidenc e to west and rear south  minor cracking developing to the wall lining and cornices, in particular to the central part of the home  w ater tank located outside in south - west corner of building Determination | Case number: 639399 Page 10 of 13 Report Key points  water leaking from tank overflow will flow into subfloor because ground surface levels in the area fall towards it  subfloor soil shows previous inundations, where water bet ween 100 - 150mm dept h like ly remained there, been absorbed into and weakened the underlying soil resulting in movement of the subfloor stumps  proximat e cause of damage is water leak from cracked pipe in water tank overflow in 2017, not water leak from neighbour’s tap in 2016 would unlik ely have res ulted in subfloor ground movement Insurer’s engineer report - including supplementary report (S) 17 - 04 - 2019 & 6 - 09 - 2019  inspection in April 2019  reviewed geo - tech report from 2009 (provided by Com) confirming soil type H - D on site. Noted lack of trees and/or recommendation for its effect in report.  site classification is H - D (highly reactive clay soils) which means  seasonal moisture changes can affect a deeper profile of soil as compared to say a class H site  soil experiences signific ant volumet ric changes with relative changes in moisture content (increase moisture causes swell & heave footings and decreases results in shrink & settlement of the footings)  abnormal soil moisture conditions would mean increased magnitude of the surface move ments (heave/settlement) and consequently increased building movement  “relative differences in the moisture content of the reactive foundation soils across different areas of the building at any point in time will lead to differential building movements”  o bserved following: Externally  home has a pad and stump footing system  trees in close proximity to house on W & N sides  flat subfloor zone which is poorly graded  subfloor ventilation “well above the requirement of Australian Standard”. This would allow wind to flow through sub - floor unimpeded causing drying out of subfloor soils foundation soils and differential footing movements  “variable surface permeability conditions of the ground coverings around the perimeter of the house, which can cause long term dif ferenc es in the moisture content of the perimet er”  lack of surface drainage within 5m of building perimeter  on turning on garden hose into downpipes, water is noted to have escaped from surface cracks on NW downpipe towards the western boundary  small depr ession on grounds in the SW – (complainant confirms this was creat ed by his friend when tank leak was found)  cracked and severely dried out subfloor surface soils Internally  minor gaps in floor boards throughout the home  gaps bet ween the base of the skirt ing and the floor boards to the western and southern walls of the kitchen (up to 14mm) and the western bedroom wall (up to 6mm).  a minor vertical wall crack ranging up to 1mm in widt h, at a Determination | Case number: 639399 Page 11 of 13 Report Key points plasterboard lining joint to the eastern wall of the bedroom.  a mi nor vertical crack (<1mm in widt h) above the western bedroom wall above the door into the bathroom.  cornice mitre dislodged and opened forming a 1mm gap to the south - east kitchen nib wall.  completed floor level survey which shows among other things:  patter n of inc reasing settlements of the house towards the west in the direction of the nearby trees.  no patterns of localised raised (" heaved") floor levels which would be typical of moisture affected soils i.e. leaking servic es.  S considered the possibility da mage being caused by both water leak events and concluded:  “unlikely that a 20 - minute surface leak (leak event 1) would provide sufficient volume of water to cause any building related movements”  “Leak Event 2 was not sufficient to have caused any building relat ed movement to the subject house. ” In reaching this conclusion S considered if leak 2 caused damage it would reas onably be expected that:  if “moisture contents of the deeper supporting foundation clays, in the vicinity closest to the leak (i.e. the s outh - west corner of the house), to have increas ed causing the affected clay soil foundations to swell (i.e. absorb moisture), resulting in the footings initially rising”, then  soil would slowly dry out (typically over the course of 6 - 12 months), “resulting in a partial rebound lowering of the raised floors as the clay foundations dried out and reached their moisture equilibrium point”.  rainwater overflow pipe would only leak when the tank is full. Given 24 months had passed from its repairs to S’s inspectio n date, “any evidence of previously existing leak related heave would not be present, which is consistent with the results of the floor level survey (i.e. no evidence was found of any locally raised floor levels)”.  the timeframe does not align with the co mplainant’s statement that cracks began to show 1 month after the leak was found and fixed as building movement as a res ult of water leak takes time to occur - due to permeability of clay soil  “if any building - related movement occurred based on this event, we would have expected to find more concentrated/significant damage to the house in close proximity to this leak i.e. the south - west corner of the house. However, based on our floor level survey and site obs ervations the movement and crack damage was not c oncent rated in any one area nor was any significant wall crack damage found consistent with a leak event”  if heave had occurred “we would also expect to find localised damage to the plasterboard walls around the south - west corner of the house which were no t found or advised by the Insured” Conclusion  cracking damage at premise is “only minor cosmetic type damage” and consistent with ongoing differential movement  the water leak events are not considered sufficient to have caused any building Determination | Case number: 639399 Page 12 of 13 Report Key points related footing movements.  “The predominant cause of the building movement related damage to the subject house is considered to be related to ongoing/long term building movement caused by footings founded in highly reactive clay foundations, subject to seasonal/climatic moisture changes, exacerbated by the nearby trees (significant effect), subfloor drying (significant effect) and poor site drainage (minor effect)”  “Footing system movement has been exacerbated by the nature of construction (i.e. isolated piers/footings)”.  “The carport pavement is still functioning as intended with the observed cracking being of a minor nature ≤1.5mm, and with no stepping across the crack. Cause of the minor cracking to the carport pavement is considered to be related to long term ongoing p avement movements caused by seasonal/climatic changes in the moisture conditions of the supporting clay subgrades, accentuated (significantly) by the nearby tree”. Complainant’s engineer (P) 3 - 01 - 2020  provided all reports completed in 2018 and 2019  inspec ted property on 13 December 2019  valid points raised in previous reports, but they do not address “the reason for the large amount of water which would have been required to cause extensive underfloor wetting”  considers:  water from neighbouring allotment p ipe leak lasting about 20 minutes as reported by the complainant would not have resulted in claimed damage  water from downpipe on the north - west corner would not have resulted in damage as it is directed away from the residence and volume also insufficient to cause the extend of wetting  “it is conjectured that once the tanks were full, all overflow would discharge to the roadside point or to the split pipe adjacent to the residence. From the calculations above it Is apparent that flows from the roof systems could have exceeded the pipe capacity, thus forcing water through the split I break. This effect could have been heightened by raised water levels m the roadside drain”  “wet conditions occurred during mid - 2017, and rainfall records for Barham would indi cat e the full extent of the rainfall”  “it is apparent that the combination of varying subfloor soil moisture conditions, growth of trees near the house, and stump footings on highly reactive soil have resulted in shrinkage and swelling of founding soils an d settlement of stumps, resulting in floor/ wall gaps, and plasterboard cracking. However, it is also concluded that the most likely cause of the extensive underfloor wetting has been discharge of overflowing roof runoff under the house. from the broken fit ting, supplemented by water from other sources ” 3.4 Our Approach This complaint has been determined based on what is fair in all the circumstances, having regard to legal principles, applicable industry codes or guidance, good industry practice and previous relevant determinations of AFCA or predecessor schemes (which are not binding). Determination | Case number: 639399 Page 13 of 13 There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any issues raised by the other. All the material provided by the parties has been reviewed and considered for the purposes of this determination. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. It is an accepted principle of general insurance law that the insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. 3.5 Relevant policy terms The relevant policy extracts are referred to in the correspondence between the parties and in the insurer’s Notice of Response dated ............ Both the policy document and the Notice have been exchanged with the complainant. 3.6 Other relevant material considered and relied on  Parties’ submissions and emails and all attachments to all submissions and emails both before and after the recommendation.  Parties’ expert reports.  Photographs and affidavits.  Correspondence between the parties.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.