Equipment breakdown claim declined for alleged non-disclosure and misalignment exclusion
Text of the determination
Determination
Case number 628725
Financial firm AAI Limited
Determination | Case number: 628725 Page 2 of 13
Case number: 628725 8 November 2019
1 Determination overview
1.1 Complaint
The complainant holds an equipment breakdown policy of insurance with the financial
firm (insurer).
The complainant lodged a claim with the insurer on 14 December 2017 due to the
failure of its laser machinery.
The insurer declined the claim on the basis that the complainant has failed to
establish a breakdown to which the policy responds. In addition to this, the insurer
has also alleged non-disclosure.
The complainant has disputed the insurer‟s claim decision.
1.2 Issues and key findings
Did the complainant fail to comply with its duty of disclosure?
The information does not show the complainant‟s failur e to disclose the original
operational issues breached its duty of disclosure. Further and in the alternative, if the
complainant was required to disclose these issues, the information does not show the
insurer would have refused to accept the risk.
Therefore, the insurer cannot deny the claim on this basis.
Has the complainant established a claim to which the policy responds?
The complainant has established an equipment breakdown of the machine and the
breakdown does not fall within the misalignment exclusion. Therefore, the policy
responds to the complainant‟s claim.
1.3 Determination
This determination is in favour of the complainant.
The insurer shall assess and pay the complainant‟s loss in accordance with the policy
terms and conditions.
Determination | Case number: 628725 Page 3 of 13
2 Reasons for determination
2.1 Did the complainant fail to comply with its duty of disclosure?
The complainant is required to provide disclosure to the insurer
Section 21 of the Insurance Contracts Act (1984) („the Act‟) requires the complainant,
prior to entering the contract, to disclose to the insurer every matter known to the
complainant that:
the complainant knows to be a matter relevant to the decision of the insurer to
accept the risk and, if so, on what terms; or
a reasonable person in the circumstances could be expected to know was relevant.
If the insured innocently fails to provide disclosure, the insurer is entitled to reduce its
liability in respect of the claim to the amount the insurer would have paid had t he
failure not occurred (section 28(3) of the Act).
The broker was acting as an agent for the complainant
When alleging non-disclosure, an insurer is normally required to have notified an
insured of the general nature and effect of the duty of disclosure. Exceptions can
apply.
For instance, section 71(1) of the Act says the insurer is not required to provide the
duty of disclosure notice if the policy was arranged by a broker who was not acting
under a binder with the insurer.
Based on the material provid ed, the parties agree the complainant‟s broker acted as
the complainant‟s agent when arranging this policy. There is no information to show
the broker was acting under a binder with the insurer.
Therefore, the insurer was not required to comply with sectio n 22 of the Act.
Information does not show the complainant breached its duty of disclosure
The insurer says there were two previous issues with the machine which it says
should have been disclosed when answering the question:
Have you had any Equipment Breakdown event (whether or not claimed under an
insurance policy) in the last 3 years?
Both the broker and the complainant say the prior issues with the machine should not
be deemed breakdowns to which the policy responds. The broker and complainant
have indicated that:
The machine was delivered to the business on 22 July 2016 and a problem
occurred shortly after installation.
Determination | Case number: 628725 Page 4 of 13
The second issue occurred in October 2016 and a similar issue occurred to the first
time.
Both times the technicians came out as it was within the three-month warranty
period. The complainant was informed that due to the “…complexities of laser
cutting machines, they do not like to be moved and that there would be settling in
issues that would need adjustments and corrections”.
There were no further problems with the machine until 11 December 2017.
At the time of incepting the policy in May 2017 there had been no further issues for
a period of about 7 months.
The complainant did not believe the machine had actually suffered a breakdown
and had not lodged any claim to the relevant insurer during that period.
The duty of disclosure requires the complainant to disclose matters that are known to
it. This is a subjective test based on the belief of the insured, not a reasonable
person. The t erm „known‟ means considerably more than believes, suspects or
strongly suspects. It must be subject to a true belief, held with sufficient assurance to
justify the term known.
The complainant has provided evidence to show that it associated the earlier i ssues
as settlement of the machine after purchase and relocation. This was established by
the fact the two issues occurred within a few months of each other and then operated
without error for around seven months afterwards. It is also supported by the fact that
no claim was lodged for any interruption or other losses associated with these two
events.
The complainant‟s evidence on this point, particularly with respect to its subjective
belief, is not refuted.
Given this, the panel does not accept the insurer has established the complainant had
known there was an „Equipment Breakdown‟ event at the time the application was
completed. At the least, the panel does not accept the insurer has shown that when
the complainant answered „no‟ to this question, that th is was not subject to a true
belief held with sufficient assurance to justify the term known.
Therefore, the panel does not accept the insurer has shown the complainant has
failed to comply with its duty of disclosure.
The insurer has not established its prejudice
Alternatively, the insurer‟s underwriting evidence is problematic.
It is based on the fact the complainant should have disclosed these prior events as
„Equipment Breakdown‟ even though the insurer says the current claim does not fall
within this description.
Determination | Case number: 628725 Page 5 of 13
Putting aside this contradiction, the underwriter goes on to state that had he been
aware that the equipment was not working properly, he would have sought an
explanation of what happened, what had been done to resolve the problem and
prevent a claim for breakdown going forward.
The difficulty here is that according to the complainant, the previous problems were
mainly to do with settlement after installation and had been operating smoothly for
about seven consecutive months. In the complainant‟s mind, the issue had been
resolved after the two visits within the warranty period.
The underwriter does not comment on what he would have done if this background
was disclosed. For example, there is no evidence as to what enquiries or
investigations would have been made.
The underwriter does say if he was aware that a machine was having operating
problems which had not been resolved, he would not have covered the machine.
However, this may be with the benefit of hindsight where issues have later
manifested. Based on the information available at the time the policy was arranged,
the machine had been operating for seven months with a genuine belief the issues
have been resolved. Further, the two previous issues had not resulted in any claim
being lodged with the relevant insurer.
The panel also notes there are no underwriting guidelines provided in support of the
underwriter‟s evidence. Instead, it appears the decision would have rested on the
underwriter‟s discretion. Given the concerns highlighted above, the panel is not
persuaded the underwriter‟s evidence shows that if the two incidents were previously
disclosed, the probable series of event to follow would have resulted in the insurer
declining the risk.
Therefore, the panel does not accept the insurer has shown any prejudice as required
under section 28(3) of the Act.
2.2 Has the complainant established a claim to which the policy responds?
The policy provides cover for equipment breakdown as defined by the policy
The policy only provides cover for equipment breakdown as defined by the policy.
The policy defines breakdown as:
Breakdown means sudden and accidental damage to an item of Equipment or a
part thereof, which manifests itself at the time of its occurrence by physical
damage to the item of Equipment or part thereof that necessitates its repair or
replacement
Determination | Case number: 628725 Page 6 of 13
The material establishes that the machine was experiencing a calibration issue
There are multiple service reports which confirm that the machine was failing to
calibrate properly on the Z axis. This meant the machine was not operating properly.
The service reports and correspondence from the attending technician state that:
On 11 December 2017 the machine was identified as cutting 10 -11mm higher than
expected. However, during the attendance of the technician from B a week later,
the machine was operating normally.
A further attendance on 24 January 2018 reveals that the upper ceramic and cone
ceramic were cracked and required replacement. On replacement the following
day, the calibration issue was still occurring.
A second tier technical review was arranged. After the technicians had read the
technical readouts from the insured machine, they opined that the replacement of a
part was required as it could not handle the correct height.
A later letter from B dated 1 March 2019 confirms its opinion that:
> The machine is considered to have broken down if it is unable to operate within
OEM specifications.
> The height sensing system has failed – this is comprised of numerous parts that
require replacement.
> The accepted protocol when attending is to exchange suspected faulty parts to
determine the issue impacting the machine.
Based on the evidence provided, it is accepted that the machine was not calibrating
on the Z axis and that B had located damaged parts in the machine. Further, the
suspected cause of the calibration was a failure of the head height sensor part(s).
The head height sensor issue falls within the policy definition of breakdown
Whilst parts of the machine have been identified as damaged and replaced, these
items do not appear to be responsible for the calibration issue. These parts may form
part of a secondary claim under the equipment breakdown. As the damaged parts
were cracked, the parts met the equipment breakdown definition as both sudden and
accidental, manifested by physical damage to the item and requiring replacement.
The evidence provided from the experts suggests there are still broken or faulty parts
in the components responsible for the head height sensor which are causing the
calibration issue. To identify the specific parts, the machine was still required to
undergo further systematic part replacement with a focus on the height sensing
elements of the machine.
The complainant has provided evidence from expert technicians for the machine
which concludes the calibration issue is caused by a head height sensor failure. The
insurer has not provided any rebutting expert opinion from a similarly qualified expert
in this machine.
Determination | Case number: 628725 Page 7 of 13
On the balance of probabilities, the panel accepts that the head height sensor part(s)
have failed leading to a calibration problem. The panel accepts this failure would
constitute sudden and accidental physical damage to an item or part given the
calibration issue occurred and manifested itself without warning after more than a
year of operations.
Therefore, the complainant has established a prima facie claim as the circumstances
fall within the policy definition of breakdown.
The issue is not caused by misalignment
The policy definition of breakdown includes a list of exclusions. The insurer has relied
on the exclusion for misalignment.
The policy does not define misalignment. The online Macquarie and Oxford
dictionaries define misalignment as follows:
to position incorrectly so that one component does not line up against another
[Macquarie dictionary definition of misalign]
The incorrect arrangement or position of something in relation to something else.
[Oxford definition of misalignment]
For calibration, the Macquarie and Oxford dictionaries are relatively consistent. They
say it is „the act/ion or process of calibrating‟. Calibrating is defined to mean:
Mark (a gauge or instrument) with a standard scale of readings [Oxford]
To check the accuracy of (any instrument, machine or gun) [Macquarie]
The Macquarie contains two other definitions for calibration but they do not appear to
be applicable. For example, they include:
To measure the calibre of
To graduate (a measuring device)
When looking at the definitions, there is a distinction between misalignment and
calibration. The term misalignment refers to a component or object not lining up to
another. This is distinguishable from calibration which refers to a type of
measurement or accuracy of a machine.
Based on the available information, the breakdown appears to be caused by a fault in
the head height sensor, manifesting as an issue in calibration on the Z axis. This has
resulted in an inaccurate measurement because of the head height sensor failure,
Determination | Case number: 628725 Page 8 of 13
rather than two components which are failing to align. Therefore, the panel does not
consider that the breakdown was the result of misalignment.
As a result, the panel concludes the claim is covered by the policy. The insurer is to
assess the loss in accordance with the policy terms.
Determination | Case number: 628725 Page 9 of 13
3 Supporting information
3.1 Policy Documentation
Policy Schedule
The policy schedule provides the following information:
Property damage equipment breakdown of $1,405,000
Interruption insurance for gross profit up to $800,000
Policy Wording
1. Coverage agreement
We agree that if during the Period of Insurance a Breakdown shall occur to
Equipment which is in use or
connected ready for use at a Situation, specified in the Schedule, We will pay for
loss:
(a) to Equipment resulting from such Breakdown; and
(b) other Insured Property directly damaged by the Breakdown.
…
4. Breakdown
Breakdown means sudden and accidental damage to an item of Equipment or a part thereof, which
manifests itself at the time of its occurrence by physical damage to the item of Equipment or part
thereof that necessitates its repair or replacement, but Breakdown shall not mean:
(a) depletion, deterioration, corrosion or erosion of material or the need to clean any component;
(b) wear and tear;
(c) leakage at any valve, fitting, shaft seal, gland packing, joint or connection;
(d) vibration or misalignment;
(e) the failure of any structure, foundation or setting (other than bedplate) supporting the Equipment
or any part thereof;
(f) the functioning of any safety device or protective device; or
Determination | Case number: 628725 Page 10 of 13
(g) the cracking of any part of a gas turbine exposed to the products of combustion.
3.2 Expert Evidence
Record Key points
Service Report of B
11 December 2017
Problem identified despite normal calibration – machine is cutting
10 - 11mm higher than expected position.
Machine operating normally during attendance
RAM dump taken of system to compare with records of when
issue arising to identify any anomalies.
Letter from Technical
Manager of B
Report
1 March 2019
The accepted protocol when attending is to exchange suspected
faulty parts to determine the issue impacting the mac hine.
Each time B attended the machine, the issue was treated as a
new i ntervention.
The height sensing system has been failed that comprises of the
numerous parts that require replacement.
The breakdown is considered when the machine is unable to
operate within OEM specifications
Breakdowns were treated as a case by case basis
In relation to B‟s discussions with the insurer, B states it was only
referring to the initial call out where the following parts were found
to be damaged:
> Ceramic ring 4 - 01642
> Ceramic cone 4 - 01959
It was recommended that the service report R - 1008485 5 - 01 be
reviewed.
B’ s Service Report
R - 10077427 - 01
Attended due to a stated fault of the calibration on Z - axis.
Issue had occurred twic e previously with several months bet ween
incidences. Problem self corrected after 48 hour system shut
down.
The technician was unable to identify the issue as it did not occur
whilst he attended the site. Took a RAM dump to compare to
records taken during fault.
B’ s Service Report
R - 10084855
The technician attended and identified the calibration was off.
The m achinery earthing points were considered acceptable.
Found cutting head ceramics and upper ceramic and cone
ceramic cracked. There were no spares so ordered stock to be
sent overnight.
Replacement of ceramics and nozzle body changed but no
change in cond ition.
A number of other items were checked and replaced with no
changed.
A second level technical review was required.
Email exchanges internally
within B
Various dates
The email exchanges discuss the technical readouts from the
insured machine and provide an opinion that the replacement of a
Determination | Case number: 628725 Page 11 of 13
Record Key points
part is required as it could not handle correct height.
The part was duly ordered.
PF
Loss Adjusting Report
19 January 2018
The machine failed on 11 December 2017 to calibrate at the Z
axis.
The machine was purchased second hand from a dealer 2 - 2.5
years ago and shortly after installation and commissioning the
issue arose on the Z axis. The technician from original suppliers
attend ed to troubleshoot, however after being turned off the
machine started working again.
In October 2016 the issue on Z axis calibration was out with no
discernible reason. After powering down it corrected.
The machine then worked continuously until 11 December 2017.
The insured no longer had faith in the original dealer and
volunteered that it had already committed to upgrading the unit to
fiber laser from B. He was also fielding offers about the sale of th e
machine subject of the claim as he could not retain both mac hines
at the premis e. He raised concerns about the reduced value of the
machine due to its non - operational state.
The adjustor indicated that if a breakdown as defined was
identified by B and t he policy responded then the reas onable costs
of attendance would form part of the claim.
The issue which continually repeats is a calibration one and there
is no identified component which has broken down.
PF
Loss Adjusting Report
12 February 2018
The adjustor is instructed that the policy was incepted on 31 May
2017 and previously minimal break down cover was provided as
part of an office package.
The issue had occurred again and a B technician was able to see
the issue in action.
The B technician bel ieves it highly likely that the same cause of
the issue was the same (except the degree of stand - off ranging
from 2mm to 10mm). This issue had occurred both before and
during the POI with the insurer. The B technician believed it was
potentially stemming f rom an earthing issue from a poor
connection.
The issue remained unsolved later and at a further attendance B
replaced damaged ceramics and nozzle, swapped cutting heads,
checked mechanics of the Z axis as well as brake and
counterbalance cylinder. Three of the CNC PCBs were
cycled/substituted with no change, encoder was checked, servo
drive replaced and recalibrated. There was no changed. All the
parts were removed and original parts reinstalled. A RAM dump
was taken and sent to Switzerland. The dump was taken during
the fault occurrence.
The adjustor then received material which suggested a
replacement of parts without confirmation as to the reason. It was
unclear if it was a continuation of replacing parts to see if problem
corrected. The adjustor was not certain repair would resolve the
matter. Later correspondence from B confirmed parts were
Determination | Case number: 628725 Page 12 of 13
Record Key points
ordered from Switzerland and replacements need to occur one by
one to see where the problem is.
The adjustor confirms his instructions that had the prior
breakdow ns been disclosed this would have alt ered acceptance
and terms of the risk. The complainant had not previously claimed
the breakdown on prior insurance.
3.3 Quantum
Record Key points
Payments required due to
machine breakdown
Machine loss $165,000
B technical costs totalling $12,441.34
Towing (transportation of machine) $630
RAR cranes to move machine $1,361.50
Welding costs $2,700
Hours spent working on machine with instructions of B between
11/12/ 2017 to 24/1/2018 was $15,600
Renting space to store machine parts $500
Subcontracting work to OB due to machine not working $7,475
Trans port ation for driving to pick up laser cuttings interstate
$3,200
Fuel Costs for the interstate trip $200
Loss of Gross Profit Breakdown date 11 December 2017 and commissioning of new
machine was 15 March 2018
The average daily turnover was $1,611.57 and the number of days
the business experienced a loss was 92.
The business lost $148,264.57 or $74,829.13 of gross profit (as a
gross profit margin of 50.47% was appl ied)
Claim Assi stance Invoice of $545 (GST exclusive)
Quotation from B
6 February 2018
Repair quotation $43,757.10 (GST exclusive) or $48, 132. 84 (GST
inclusive).
3.4 Documentation relating to disclosure
Record Key points
Formal Underwriting
Statement
If the complainant had selected yes to indicate a breakdown within
3 years then the quote would have been referred to an
underwriting if in the prior three years there has been.
(a) 1 breakdown (whether or not insured) exceeding $5,000; or
(b) More than 1 breakdown ( whether or not insured) of any $ size
The underwriter would have gathered details of the breakdowns.
The breakdown information is an integral piec e of information in
Determination | Case number: 628725 Page 13 of 13
Record Key points
understanding the expos ure.
If the problem was in fact considered to be a „breakdown‟ th en the
breakdown occurred prior to incepting the policy (as it happened
twice prior to policy inception without being fixed). If that is not the
case, then by definition there had to have been at least three
breakdowns, at least two of which occurred prior to the inception
of the policy.
Had an underwriter known that they were being asked to quote a
risk in which there was equipment not working properly, they
would not have simply treated the risk as if all the equipment as
normal. They would have required an explanation of what had
happened and what had been done to resolve the problem in
order to prevent a claim on contemplated breakdown policy going
forward.
Had the underwriter been advised that there was a machine that
was having operating problems and that was problem was not
resolved, he would not have provided cover on that machine.
Letter from Broker
16 October 2018
The broker completed the quotation for insurance.
The broker had met with the complainant on 2 May 2017 to
discuss insurance needs.
The broker has confirmed there had been no previous claimable
events/breakdowns.
The broker was aware that the Bystronic laser cutter had what he
considered teething issues in the first couple of months after
installation which was being corrected and ad dressed by the
company that sold and installed the machine.
This would not have been deemed mechanical failure or
breakdowns, thus in respect to declaring insurable losses he did
not think this occurrenc e had any relevance as there was no
identifiable fai lure part/component.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.