Home / Suncorp Group / Determination 628725

Determination 628725

Equipment breakdown claim declined for alleged non-disclosure and misalignment exclusion

FirmSuncorp Group
Decided2019-12-03
ProductGeneral Insurance · Other general
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A business's laser cutting machine failed, and the insurer declined its equipment breakdown claim for non-disclosure of earlier problems and under the misalignment exclusion. AFCA found the breakdown was a covered head height sensor failure and the non-disclosure and prejudice were not established, so the insurer must assess and pay the loss under the policy.

Under the Insurance Contracts Act the insurer could not show a breach of the duty of disclosure or prejudice, and the policy's breakdown definition covers the sudden sensor failure, which is not misalignment.

Issues

Subjects and remedies

business interruptionsmall businesspay claim

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination Case number 628725 Financial firm AAI Limited Determination | Case number: 628725 Page 2 of 13 Case number: 628725 8 November 2019 1 Determination overview 1.1 Complaint The complainant holds an equipment breakdown policy of insurance with the financial firm (insurer). The complainant lodged a claim with the insurer on 14 December 2017 due to the failure of its laser machinery. The insurer declined the claim on the basis that the complainant has failed to establish a breakdown to which the policy responds. In addition to this, the insurer has also alleged non-disclosure. The complainant has disputed the insurer‟s claim decision. 1.2 Issues and key findings Did the complainant fail to comply with its duty of disclosure? The information does not show the complainant‟s failur e to disclose the original operational issues breached its duty of disclosure. Further and in the alternative, if the complainant was required to disclose these issues, the information does not show the insurer would have refused to accept the risk. Therefore, the insurer cannot deny the claim on this basis. Has the complainant established a claim to which the policy responds? The complainant has established an equipment breakdown of the machine and the breakdown does not fall within the misalignment exclusion. Therefore, the policy responds to the complainant‟s claim. 1.3 Determination This determination is in favour of the complainant. The insurer shall assess and pay the complainant‟s loss in accordance with the policy terms and conditions. Determination | Case number: 628725 Page 3 of 13 2 Reasons for determination 2.1 Did the complainant fail to comply with its duty of disclosure? The complainant is required to provide disclosure to the insurer Section 21 of the Insurance Contracts Act (1984) („the Act‟) requires the complainant, prior to entering the contract, to disclose to the insurer every matter known to the complainant that:  the complainant knows to be a matter relevant to the decision of the insurer to accept the risk and, if so, on what terms; or  a reasonable person in the circumstances could be expected to know was relevant. If the insured innocently fails to provide disclosure, the insurer is entitled to reduce its liability in respect of the claim to the amount the insurer would have paid had t he failure not occurred (section 28(3) of the Act). The broker was acting as an agent for the complainant When alleging non-disclosure, an insurer is normally required to have notified an insured of the general nature and effect of the duty of disclosure. Exceptions can apply. For instance, section 71(1) of the Act says the insurer is not required to provide the duty of disclosure notice if the policy was arranged by a broker who was not acting under a binder with the insurer. Based on the material provid ed, the parties agree the complainant‟s broker acted as the complainant‟s agent when arranging this policy. There is no information to show the broker was acting under a binder with the insurer. Therefore, the insurer was not required to comply with sectio n 22 of the Act. Information does not show the complainant breached its duty of disclosure The insurer says there were two previous issues with the machine which it says should have been disclosed when answering the question: Have you had any Equipment Breakdown event (whether or not claimed under an insurance policy) in the last 3 years? Both the broker and the complainant say the prior issues with the machine should not be deemed breakdowns to which the policy responds. The broker and complainant have indicated that:  The machine was delivered to the business on 22 July 2016 and a problem occurred shortly after installation. Determination | Case number: 628725 Page 4 of 13  The second issue occurred in October 2016 and a similar issue occurred to the first time.  Both times the technicians came out as it was within the three-month warranty period. The complainant was informed that due to the “…complexities of laser cutting machines, they do not like to be moved and that there would be settling in issues that would need adjustments and corrections”.  There were no further problems with the machine until 11 December 2017.  At the time of incepting the policy in May 2017 there had been no further issues for a period of about 7 months.  The complainant did not believe the machine had actually suffered a breakdown and had not lodged any claim to the relevant insurer during that period. The duty of disclosure requires the complainant to disclose matters that are known to it. This is a subjective test based on the belief of the insured, not a reasonable person. The t erm „known‟ means considerably more than believes, suspects or strongly suspects. It must be subject to a true belief, held with sufficient assurance to justify the term known. The complainant has provided evidence to show that it associated the earlier i ssues as settlement of the machine after purchase and relocation. This was established by the fact the two issues occurred within a few months of each other and then operated without error for around seven months afterwards. It is also supported by the fact that no claim was lodged for any interruption or other losses associated with these two events. The complainant‟s evidence on this point, particularly with respect to its subjective belief, is not refuted. Given this, the panel does not accept the insurer has established the complainant had known there was an „Equipment Breakdown‟ event at the time the application was completed. At the least, the panel does not accept the insurer has shown that when the complainant answered „no‟ to this question, that th is was not subject to a true belief held with sufficient assurance to justify the term known. Therefore, the panel does not accept the insurer has shown the complainant has failed to comply with its duty of disclosure. The insurer has not established its prejudice Alternatively, the insurer‟s underwriting evidence is problematic. It is based on the fact the complainant should have disclosed these prior events as „Equipment Breakdown‟ even though the insurer says the current claim does not fall within this description. Determination | Case number: 628725 Page 5 of 13 Putting aside this contradiction, the underwriter goes on to state that had he been aware that the equipment was not working properly, he would have sought an explanation of what happened, what had been done to resolve the problem and prevent a claim for breakdown going forward. The difficulty here is that according to the complainant, the previous problems were mainly to do with settlement after installation and had been operating smoothly for about seven consecutive months. In the complainant‟s mind, the issue had been resolved after the two visits within the warranty period. The underwriter does not comment on what he would have done if this background was disclosed. For example, there is no evidence as to what enquiries or investigations would have been made. The underwriter does say if he was aware that a machine was having operating problems which had not been resolved, he would not have covered the machine. However, this may be with the benefit of hindsight where issues have later manifested. Based on the information available at the time the policy was arranged, the machine had been operating for seven months with a genuine belief the issues have been resolved. Further, the two previous issues had not resulted in any claim being lodged with the relevant insurer. The panel also notes there are no underwriting guidelines provided in support of the underwriter‟s evidence. Instead, it appears the decision would have rested on the underwriter‟s discretion. Given the concerns highlighted above, the panel is not persuaded the underwriter‟s evidence shows that if the two incidents were previously disclosed, the probable series of event to follow would have resulted in the insurer declining the risk. Therefore, the panel does not accept the insurer has shown any prejudice as required under section 28(3) of the Act. 2.2 Has the complainant established a claim to which the policy responds? The policy provides cover for equipment breakdown as defined by the policy The policy only provides cover for equipment breakdown as defined by the policy. The policy defines breakdown as: Breakdown means sudden and accidental damage to an item of Equipment or a part thereof, which manifests itself at the time of its occurrence by physical damage to the item of Equipment or part thereof that necessitates its repair or replacement Determination | Case number: 628725 Page 6 of 13 The material establishes that the machine was experiencing a calibration issue There are multiple service reports which confirm that the machine was failing to calibrate properly on the Z axis. This meant the machine was not operating properly. The service reports and correspondence from the attending technician state that:  On 11 December 2017 the machine was identified as cutting 10 -11mm higher than expected. However, during the attendance of the technician from B a week later, the machine was operating normally.  A further attendance on 24 January 2018 reveals that the upper ceramic and cone ceramic were cracked and required replacement. On replacement the following day, the calibration issue was still occurring.  A second tier technical review was arranged. After the technicians had read the technical readouts from the insured machine, they opined that the replacement of a part was required as it could not handle the correct height.  A later letter from B dated 1 March 2019 confirms its opinion that: > The machine is considered to have broken down if it is unable to operate within OEM specifications. > The height sensing system has failed – this is comprised of numerous parts that require replacement. > The accepted protocol when attending is to exchange suspected faulty parts to determine the issue impacting the machine. Based on the evidence provided, it is accepted that the machine was not calibrating on the Z axis and that B had located damaged parts in the machine. Further, the suspected cause of the calibration was a failure of the head height sensor part(s). The head height sensor issue falls within the policy definition of breakdown Whilst parts of the machine have been identified as damaged and replaced, these items do not appear to be responsible for the calibration issue. These parts may form part of a secondary claim under the equipment breakdown. As the damaged parts were cracked, the parts met the equipment breakdown definition as both sudden and accidental, manifested by physical damage to the item and requiring replacement. The evidence provided from the experts suggests there are still broken or faulty parts in the components responsible for the head height sensor which are causing the calibration issue. To identify the specific parts, the machine was still required to undergo further systematic part replacement with a focus on the height sensing elements of the machine. The complainant has provided evidence from expert technicians for the machine which concludes the calibration issue is caused by a head height sensor failure. The insurer has not provided any rebutting expert opinion from a similarly qualified expert in this machine. Determination | Case number: 628725 Page 7 of 13 On the balance of probabilities, the panel accepts that the head height sensor part(s) have failed leading to a calibration problem. The panel accepts this failure would constitute sudden and accidental physical damage to an item or part given the calibration issue occurred and manifested itself without warning after more than a year of operations. Therefore, the complainant has established a prima facie claim as the circumstances fall within the policy definition of breakdown. The issue is not caused by misalignment The policy definition of breakdown includes a list of exclusions. The insurer has relied on the exclusion for misalignment. The policy does not define misalignment. The online Macquarie and Oxford dictionaries define misalignment as follows: to position incorrectly so that one component does not line up against another [Macquarie dictionary definition of misalign] The incorrect arrangement or position of something in relation to something else. [Oxford definition of misalignment] For calibration, the Macquarie and Oxford dictionaries are relatively consistent. They say it is „the act/ion or process of calibrating‟. Calibrating is defined to mean: Mark (a gauge or instrument) with a standard scale of readings [Oxford] To check the accuracy of (any instrument, machine or gun) [Macquarie] The Macquarie contains two other definitions for calibration but they do not appear to be applicable. For example, they include: To measure the calibre of To graduate (a measuring device) When looking at the definitions, there is a distinction between misalignment and calibration. The term misalignment refers to a component or object not lining up to another. This is distinguishable from calibration which refers to a type of measurement or accuracy of a machine. Based on the available information, the breakdown appears to be caused by a fault in the head height sensor, manifesting as an issue in calibration on the Z axis. This has resulted in an inaccurate measurement because of the head height sensor failure, Determination | Case number: 628725 Page 8 of 13 rather than two components which are failing to align. Therefore, the panel does not consider that the breakdown was the result of misalignment. As a result, the panel concludes the claim is covered by the policy. The insurer is to assess the loss in accordance with the policy terms. Determination | Case number: 628725 Page 9 of 13 3 Supporting information 3.1 Policy Documentation Policy Schedule The policy schedule provides the following information:  Property damage equipment breakdown of $1,405,000  Interruption insurance for gross profit up to $800,000 Policy Wording 1. Coverage agreement We agree that if during the Period of Insurance a Breakdown shall occur to Equipment which is in use or connected ready for use at a Situation, specified in the Schedule, We will pay for loss: (a) to Equipment resulting from such Breakdown; and (b) other Insured Property directly damaged by the Breakdown. … 4. Breakdown Breakdown means sudden and accidental damage to an item of Equipment or a part thereof, which manifests itself at the time of its occurrence by physical damage to the item of Equipment or part thereof that necessitates its repair or replacement, but Breakdown shall not mean: (a) depletion, deterioration, corrosion or erosion of material or the need to clean any component; (b) wear and tear; (c) leakage at any valve, fitting, shaft seal, gland packing, joint or connection; (d) vibration or misalignment; (e) the failure of any structure, foundation or setting (other than bedplate) supporting the Equipment or any part thereof; (f) the functioning of any safety device or protective device; or Determination | Case number: 628725 Page 10 of 13 (g) the cracking of any part of a gas turbine exposed to the products of combustion. 3.2 Expert Evidence Record Key points Service Report of B 11 December 2017  Problem identified despite normal calibration – machine is cutting 10 - 11mm higher than expected position.  Machine operating normally during attendance  RAM dump taken of system to compare with records of when issue arising to identify any anomalies. Letter from Technical Manager of B Report 1 March 2019  The accepted protocol when attending is to exchange suspected faulty parts to determine the issue impacting the mac hine.  Each time B attended the machine, the issue was treated as a new i ntervention.  The height sensing system has been failed that comprises of the numerous parts that require replacement.  The breakdown is considered when the machine is unable to operate within OEM specifications  Breakdowns were treated as a case by case basis  In relation to B‟s discussions with the insurer, B states it was only referring to the initial call out where the following parts were found to be damaged: > Ceramic ring 4 - 01642 > Ceramic cone 4 - 01959  It was recommended that the service report R - 1008485 5 - 01 be reviewed. B’ s Service Report R - 10077427 - 01  Attended due to a stated fault of the calibration on Z - axis.  Issue had occurred twic e previously with several months bet ween incidences. Problem self corrected after 48 hour system shut down.  The technician was unable to identify the issue as it did not occur whilst he attended the site. Took a RAM dump to compare to records taken during fault. B’ s Service Report R - 10084855  The technician attended and identified the calibration was off.  The m achinery earthing points were considered acceptable.  Found cutting head ceramics and upper ceramic and cone ceramic cracked. There were no spares so ordered stock to be sent overnight.  Replacement of ceramics and nozzle body changed but no change in cond ition.  A number of other items were checked and replaced with no changed.  A second level technical review was required. Email exchanges internally within B Various dates  The email exchanges discuss the technical readouts from the insured machine and provide an opinion that the replacement of a Determination | Case number: 628725 Page 11 of 13 Record Key points part is required as it could not handle correct height.  The part was duly ordered. PF Loss Adjusting Report 19 January 2018  The machine failed on 11 December 2017 to calibrate at the Z axis.  The machine was purchased second hand from a dealer 2 - 2.5 years ago and shortly after installation and commissioning the issue arose on the Z axis. The technician from original suppliers attend ed to troubleshoot, however after being turned off the machine started working again.  In October 2016 the issue on Z axis calibration was out with no discernible reason. After powering down it corrected.  The machine then worked continuously until 11 December 2017.  The insured no longer had faith in the original dealer and volunteered that it had already committed to upgrading the unit to fiber laser from B. He was also fielding offers about the sale of th e machine subject of the claim as he could not retain both mac hines at the premis e. He raised concerns about the reduced value of the machine due to its non - operational state.  The adjustor indicated that if a breakdown as defined was identified by B and t he policy responded then the reas onable costs of attendance would form part of the claim.  The issue which continually repeats is a calibration one and there is no identified component which has broken down. PF Loss Adjusting Report 12 February 2018  The adjustor is instructed that the policy was incepted on 31 May 2017 and previously minimal break down cover was provided as part of an office package.  The issue had occurred again and a B technician was able to see the issue in action.  The B technician bel ieves it highly likely that the same cause of the issue was the same (except the degree of stand - off ranging from 2mm to 10mm). This issue had occurred both before and during the POI with the insurer. The B technician believed it was potentially stemming f rom an earthing issue from a poor connection.  The issue remained unsolved later and at a further attendance B replaced damaged ceramics and nozzle, swapped cutting heads, checked mechanics of the Z axis as well as brake and counterbalance cylinder. Three of the CNC PCBs were cycled/substituted with no change, encoder was checked, servo drive replaced and recalibrated. There was no changed. All the parts were removed and original parts reinstalled. A RAM dump was taken and sent to Switzerland. The dump was taken during the fault occurrence.  The adjustor then received material which suggested a replacement of parts without confirmation as to the reason. It was unclear if it was a continuation of replacing parts to see if problem corrected. The adjustor was not certain repair would resolve the matter. Later correspondence from B confirmed parts were Determination | Case number: 628725 Page 12 of 13 Record Key points ordered from Switzerland and replacements need to occur one by one to see where the problem is.  The adjustor confirms his instructions that had the prior breakdow ns been disclosed this would have alt ered acceptance and terms of the risk. The complainant had not previously claimed the breakdown on prior insurance. 3.3 Quantum Record Key points Payments required due to machine breakdown  Machine loss $165,000  B technical costs totalling $12,441.34  Towing (transportation of machine) $630  RAR cranes to move machine $1,361.50  Welding costs $2,700  Hours spent working on machine with instructions of B between 11/12/ 2017 to 24/1/2018 was $15,600  Renting space to store machine parts $500  Subcontracting work to OB due to machine not working $7,475  Trans port ation for driving to pick up laser cuttings interstate $3,200  Fuel Costs for the interstate trip $200 Loss of Gross Profit  Breakdown date 11 December 2017 and commissioning of new machine was 15 March 2018  The average daily turnover was $1,611.57 and the number of days the business experienced a loss was 92.  The business lost $148,264.57 or $74,829.13 of gross profit (as a gross profit margin of 50.47% was appl ied) Claim Assi stance  Invoice of $545 (GST exclusive) Quotation from B 6 February 2018  Repair quotation $43,757.10 (GST exclusive) or $48, 132. 84 (GST inclusive). 3.4 Documentation relating to disclosure Record Key points Formal Underwriting Statement  If the complainant had selected yes to indicate a breakdown within 3 years then the quote would have been referred to an underwriting if in the prior three years there has been. (a) 1 breakdown (whether or not insured) exceeding $5,000; or (b) More than 1 breakdown ( whether or not insured) of any $ size  The underwriter would have gathered details of the breakdowns.  The breakdown information is an integral piec e of information in Determination | Case number: 628725 Page 13 of 13 Record Key points understanding the expos ure.  If the problem was in fact considered to be a „breakdown‟ th en the breakdown occurred prior to incepting the policy (as it happened twice prior to policy inception without being fixed). If that is not the case, then by definition there had to have been at least three breakdowns, at least two of which occurred prior to the inception of the policy.  Had an underwriter known that they were being asked to quote a risk in which there was equipment not working properly, they would not have simply treated the risk as if all the equipment as normal. They would have required an explanation of what had happened and what had been done to resolve the problem in order to prevent a claim on contemplated breakdown policy going forward.  Had the underwriter been advised that there was a machine that was having operating problems and that was problem was not resolved, he would not have provided cover on that machine. Letter from Broker 16 October 2018  The broker completed the quotation for insurance.  The broker had met with the complainant on 2 May 2017 to discuss insurance needs.  The broker has confirmed there had been no previous claimable events/breakdowns.  The broker was aware that the Bystronic laser cutter had what he considered teething issues in the first couple of months after installation which was being corrected and ad dressed by the company that sold and installed the machine.  This would not have been deemed mechanical failure or breakdowns, thus in respect to declaring insurable losses he did not think this occurrenc e had any relevance as there was no identifiable fai lure part/component.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.