Home / IAG / Determination 625920
Determination 625920
Partial denial of storm and leaking-pipe damage to support post
Summary
The complainant claimed for storm and leaking-pipe damage to her home, including a support post. AFCA upheld the insurer's partial denial but ordered reimbursement of a conditional $1,500 make-safe cost and $1,000 non-financial loss.
The evidence did not show the leaking pipe was the proximate cause of the post's movement, which was more likely caused by lateral loads from a retaining wall.
Issues
- Claim denial primary · not upheld“The insurer can partially deny the claim because the information does not show the post moved because of the leaking pipe.”
- Poor communication secondary · upheld“The insurer should pay $1,000 in non-financial loss due to an inappropriate email and unclear information as to what was payable under the policy.”
- Repairs or contractors secondary · not upheld“The information does not show the insurer's make-safe works were inadequate or caused further damage.”
Subjects and remedies
home or building damagepay claimpay non financial loss
Related
Text of the determination
Determination
Case number 625920
Financial firm Insurance Australia Limited
Determination | Case number: 625920 Page 1 of 7
Case number: 625920 20 November 2019
1 Determination overview
1.1 Complaint
The complainant lodged a claim with the financial firm (insurer) for damage she says
was caused by a leaking storm water pipe at the base of a support post.
The insurer accepted damage to the patio roof beam under the insured event of
storm. The insurer denied the remainder of the damage because it says it was not
caused by an insured event.
The complainant disputes this decision. She also says the make safe works carried
out by the insurer were defective and caused additional damage. Further, the
complainant says the insurer acted deceitfully.
1.2 Issues and key findings
Can the insurer partially deny the claim?
The insurer can partially deny the claim because the information does not show the
post moved because of the leaking pipe.
Did the insurer cause further damage due to inadequate make-safe works?
The information does not show the insurer’s make -safe works were inadequate or
caused further damage.
The complainant may have incurred $1,500 in doing additional make-safe works. This
is payable subject to certain conditions set out in section 2.2 being met.
Should the insurer pay non-financial loss?
The insurer should pay $1,000 in non-financial loss due to an inappropriate email and
the fact it provided unclear information as to what was payable under the policy.
1.3 Determination
This determination is substantially in favour of the insurer.
The insurer can partially deny the claim.
The insurer is to reimburse the complainant the sum of $1,500 subject to the
conditions set out in section 2.2 being satisfied.
The insurer is to pay $1,000 in non-financial loss.
Determination | Case number: 625920 Page 2 of 7
2 Reasons for determination
2.1 Can the insurer partially deny the claim?
Complainant must establish a valid claim
The complainant is required to show that, on the balance of probabilities, she suffered
a loss caused by an event she is insured for under the policy (insured event).
This is known as a prima facie, or valid, claim.
The complainant’s policy covers her for loss or damage to her home if it is caused by
a number of insured events. Relevant to this dispute is ‘Water and oil leaks’.
Therefore, in order for the complainant to establish a valid claim, the evidence must
show the damage being claimed was caused by this event.
Parties dispute as to whether a leak caused the damage to the pole
The insurer accepted liability for a damaged patio beam on the basis it was likely
caused by strong winds.
The insurer did not accept liability for the movement of a timber post, which supported
an upper level deck at the rear, or any resultant damage from this. The resultant
damage included the bowing of an inner timber bearer. The insurer says it is not liable
because the damage was not caused by the leaking pipe. The insurer has relied on
reports from DF, SG, PC and DB.
The complainant has disputed the insurer’s position on several bases. This included
saying the experts are not qualified to make the opinions provided and are not
reliable. She has also provided reports from JD, an email from DW and previous
valuation reports in support.
It is not in dispute that a broken stormwater pipe was identified near the support post
that moved. The parties disagree as to whether the leaking pipe was t he proximate
cause of this movement.
Proximate cause is the dominant, efficient or operative cause of the loss. It is not
required to be last in time or the sole cause. It is a question of fact that depends on
the circumstances of each case. It requires a common sense evaluation of the
evidence.
Summary of relevant evidence
I do not propose to reiterate the contents of these reports and documents in detail
given they have been exchanged between the parties. I will summarise their main
findings and comments.
Determination | Case number: 625920 Page 3 of 7
DF, an engineer, noted that a pre-existing retaining wall structure was imposing
lateral loads onto the bottom of the post. DF concluded that this, and the removal of
pergola rafters, likely caused the post to move. Building consultant SG also agreed
that the retaining wall likely caused the movement of the post.
Both DF and SG also noted that the retaining wall should not be imposing lateral
loads to the support posts.
DF said that given the concrete slab under the support post, the concrete backfilling
and the steep natural slope of the ground, it is unlikely the pipe’s break has caused
the movement.
An email from geotechnical engineer DW did not add much to the issue. DW noted
that without appropriate testing and investigations, it would be impossible to identify
the likely mechanism. He noted a ‘Hydro excavation’ would be the best method. He
does not identify how this would assist in identifying the cause.
JD provided two reports. JD said the retaining wall had no bearing on the post’s
movement. He did not provide any reasoning to support this conclusion. This is
difficult to accept as it is apparent a wall retaining about 1.2 metres of soil would have
lateral loads on it. It is also clear the support post was not designed to take this lateral
load whilst also supporting a deck.
JD says the broken pipe caused the movement. He does not expand on this. JD also
said he conducted hydro-excavation of the pole footing. However, he does not identify
what was found in this excavation or how it supports the conc lusion that the leaking
pipe was the cause of movement.
Information does not show proximate cause is the leaking pipe
Having carefully reviewed the available information, I am not satisfied the evidence
shows the proximate cause of damage to the support post was the leaking pipe.
DF and SG provide compelling evidence that the retaining wall was likely causing
lateral loads to the support post. Further, I consider it unlikely that this support post
was designed to take such lateral loads.
Therefore, it is plausible and logical to accept this additional load caused the post to
move. It is also consistent with the fact the movement was coming from the bottom of
the post.
DF also provided persuasive reasoning as to why the leak was unlikely to have
caused the m ovement. JD’s report does not address this reasoning.
Given this, I am not persuaded the evidence shows the proximate cause of damage
to the support post was the leaking pipe. Neither am I satisfied the evidence shows
the proximate cause was another event insured under the policy.
Determination | Case number: 625920 Page 4 of 7
Therefore, the insurer is entitled to deny liability for the damage to the support post
and any resultant damage being claimed.
Complainant’s arguments do not assist her
The complainant raised numerous arguments in challenging th e insurer’s position.
This included the following:
the insurer admitted during a conciliation conference that the support post moved
due to the leak
DB had changed his assessment reports
DF and SG’s reports are based on incorrect information provided by DB and PC
no other poles have moved except the one that had the broken pipe nearby
two previous property reports showed no essential repairs were required
no testing was done for lateral loads from the retaining wall
the experts were not qualified to make the opinions
I do not accept these arguments assist her for the following reasons.
The insurer’s alleged admission in a conciliation conference is inconsistent to its
submissions made and the expert evidence it provided. Neither has there been
anything in writing from the insurer to confirm it now accepts the post moved due to
the leak.
As I have not relied upon DB’s evidence, any alleged change to his reports was
immaterial to the outcome.
The main compelling points from DF and SG were the lateral loads from the retaining
wall and the fact the leak was unlikely to be the cause of the post’s movement. The
evidence shows, and it is not disputed, the retaining wall was leaning against the
post. Therefore, I do not accept their conclusions on these material points was based
on incorrect information.
I acknowledge the one pole has moved. On this factor alone, this supports the
complainant’s position. However, when this is weighed with the rest of the evidence, I
am not satisfied the leak was the proximate cause . Particularly given:
the lateral loads being applied by the retaining wall
DF’s explanation as to why the leak could not cause the damage
JD not providing any evidence to show what moisture was identified in the soil to
cause the post to move to the extent it did
The two property reports are valuations and are brief. No mention or analysis is made
about the support posts or the lateral loads being imposed by the retaining wall.
Therefore, they add little weight to the issue.
Determination | Case number: 625920 Page 5 of 7
I accept it is apparent the retaining wall would be adding lateral loads given it is
retaining about 1.2 metres of soil. I also accept DF and SG are qualified to make the
opinion they have. DF is a qualified engineer and SG is a building consultant.
Insurer not liable for the cost of moving the retaining wall
The complainant is claiming $3,000 for the removal and relocation of the retaining
wall. The complainant says she only incurred that cost because the insurer advised
she was required to move it away from the support post. She notes that DF told her
this was not necessary.
DF’s report says otherwise. He concluded the retaining wall was a likely cause of the
support post moving. SG agreed.
JD says the moving the wall was not necessary. This is difficult to accept as there is
nothing to indicate that it was appropriate for the post, which is a supporting structure
for an upper level deck, should also take the lateral loads from a retaining wall for
about 1.2 metres of soil.
Given this, I am not persuaded this is a cost the complainant could have avoided or
should be payable by the insurer.
Insurer has cash settled the accepted portion reasonably
The insurer obtained a quote from HB for the accepted beam totalling $3,639.02. The
insurer agreed to cash settle based on this quote plus a 20% uplift minus the excess.
The complainant has raised concerns about this scope of works. However, there is no
evidence to show this was insufficient regarding the accepted beam. I also note the
insurer has allowed an additional 20%. This will factor contingencies such as possible
variances and the risks of the work transferring to the complainant.
Given this, I do not accept the insurer is required to pay more towards this claim.
2.2 Did the insurer cause further damage when undertaking the make-safe?
Information does not show the make-safe works were inadequate
The complainant says the insurer’s make -safe works caused further damage.
JD’s report supports this. JD says faulty make -safe works to the support post resulted
in further movement and damage. JD also said no make-safe works were done to the
upper deck and this resulted in further damage to the upper decks beam, handrails,
lattice inserts, upper deck beam and span-line roofing.
JD does not identify what make-safe works were required for these areas.
Determination | Case number: 625920 Page 6 of 7
It is important to note that a distinction should be made between make-safe works
and repairs. As evident by its name, the purpose of make-safe works is to make the
area is safe. It is not necessarily to prevent any possible further damage.
DF was asked to comment on the make-safe works. He said the works could be
improved. The complainant says this shows the works were faulty. I do not agree. DF
was satisfied the works were sufficient for their purpose but agreed that they could be
improved. This does not infer the original works were faulty.
Given this information, I am not satisfied the complainant has shown the make-safe
works were faulty or that this caused the additional damage being claimed.
Insurer to pay $1,500 subject to certain conditions
The complainant said she incurred additional costs to make the site safe. In her
dispute form, she said she paid $3,219.72 plus $120.
However, in a statement sent to AFCA on 4 June 2019, she referred to payments she
made on the claim. The only one relevant to the make- safe was a payment for ‘make
safe upper deck’ totalling $1,500 paid on 31 January 2019. This statement did not
refer to any other payments that reconcile with the amounts sought in the dispute
form.
A copy of the invoice paid was not provided. Therefore, it is not clear what works were
done for this sum.
If the payment of $1,500 was for additional make -safe works, then this should be
paid. This is because it was paid on 31 January 2019 which was during the time the
insurer was still reviewing the claim. As such, make-safe costs would have normally
formed part of the insurer’s cost to assess the claim.
Accordingly, the insurer is to reimburse this amount subject to the complainant
providing an invoice from the contractor showing:
what works were done,
why it was necessary for these works to be done to make the site safe, and
confirmation the amount was paid.
I do not accept interest is payable on this given the insurer has not been able to
assess whether these costs were reasonably required.
2.3 Should the insurer pay non-financial loss?
Compensation is awarded conservatively
Under the AFCA Rules, we may award compensation (capped at $5,000) for non-
financial loss where a complainant has suffered an unusual degree or extent of
Determination | Case number: 625920 Page 7 of 7
physical inconvenience, time taken to resolve the situation or interference with their
expectation of enjoyment or peace of mind.
We take a conservative approach to compensation for non-financial loss. It is not
awarded when a person suffers the normal degree of inconvenience when a problem
occurs.
Insurer should pay $1,000 in non-financial loss
The complainant has raised various concerns about the insurer’s claims handling.
This included the following:
the insurer has acted deceitfully as it was describing its contractors as holding
qualifications that they did not
the insurer initially accepted the claim for the post but reversed this decision
an email sent by DB contained inappropriate comments
the claim was not properly assessed or reviewed
For reasons explained, I accept the insurer’s decision on the claim was reasonable.
Further, I accepted the experts were qualified to provide the opinions offered.
I do accept that DB’s email did contain comments that were inappropriate. It
highlighted concerns about the complainant being difficult or was looking for someone
to blame. It also indicates DB was prejudging the claim.
The information also indicates the complainant was told the post would be covered
and this was later reversed. This would have been distressing to the complainant who
had an expectation that the claim was payable.
Given all this, I accept it is fair the insurer pays $1,000 in non-financial loss.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.