Home / QBE / Determination 622094

Determination 622094

Claim declined for ceiling water damage attributed to structural defect, faulty workmanship and long-term leaking

FirmQBE
Decided2019-10-18
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainants claimed for water damage to their lounge ceiling after a December 2017 storm. AFCA found the damage had been leaking for years from structural and workmanship faults, including a 2011 leak, so the policy exclusions applied.

The insurer proved the excluded causes of structural defect, faulty design or workmanship and gradual deterioration, after the complainants established a storm-related valid claim.

Issues

Subjects and remedies

home or building damageno remedy

Related

All QBE determinations · Find similar determinations

Text of the determination

Determination Case number 622094 Financial firm QBE Insurance (Australia) Limited Determination | Case number: 622094 Page 1 of 5 Case number: 622094 18 October 2019 1 Determination overview 1.1 Complaint The complainants hold a home and contents insurance policy with the financial firm (insurer). On 5 December 2017, the y lodged a claim after noticing water damage to their property. They advised the insurer that water was leaking from the lounge room ceiling, causing damage to the building and contents. After assessing the damage, the insurer declined the claim, saying the damage was due to construction defects as well as poor and faulty workmanship, and had been occurring over a prolonged period. The complainants believe the damage should be covered. The case manager provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the (complainant/financial firm). A copy of the recommendation is attached to this determination. 1.2 Issues and key findings Were the findings of the recommendation correct? The findings contained in the recommendation were correct and are adopted in this determination. Further submissions provided after the recommendation have been considered. Is the insurer entitled to decline the claim? The available evidence indicates, on balance, the damage has been occurring since as early as April 2011 and was not caused by the storm event but rather by factors excluded under the policy. That means the insurer is entitled to decline the claim. 1.3 Determination This determination is in favour of the insurer. It is not required to take any further action. Determination | Case number: 622094 Page 2 of 5 2 Reasons for determination 2.1 Were the findings in the recommendation correct? I have decided this case on the basis of what is fair in the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous AFCA decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. I am satisfie d that the case manager‟s recommendation contains an accurate summary of the complaint, the issues to be determined, any applicable paragraphs of the Rules and any relevant law. I agree with the case manager‟s reasons for the recommendation and the recommended outcome. 2.2 Is the insurer entitled to decline the claim? Complainants have established a valid claim The policy covers loss and damage caused by storm (including a named cyclone), rainwater, flood or wind. The policy also covers loss and damage caused by water or liquid escaping from a fixed gutter. There is no dispute that a storm occurred on or about 2 December 2017 and there is water damage to the property. I am satisfied the complainants have established a valid claim. Insurer says the cause of the loss is excluded The onus then shifts to the insurer to establish it is entitled to decline the claim. The complainants‟ p olicy does not cover accidental damage, and specifically excludes loss or damage caused by storm or escape of liquid when water enters the building: Because of a structural defect, faulty design, or faulty workmanship. The policy also excludes loss or damage which is caused directly or indirectly by erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear. The insurer has declined the claim as it says it is clear from the nature and extent of the damage that it has been occurring over an extended period of time and is due to a combination of structural defect, faulty design or faulty workmanship. Determination | Case number: 622094 Page 3 of 5 Assessment identified maintenance and other faults The insurer appointed a building assessor (PA), to assess the damage , and roofing plumber (BP) also then attended the property to locate the source of the leak. BP‟s testing identified a leak in the rendered wall and box gutter. They recommended resealing all joints and pulling up the timber balcony to assess the balcony. PA provided a further report dated 27 June 2018, which referred to the need to ensure the roof below the balcony was sealed and watertight. PA noted the water entry points were maintenance-related but subsequently also clarified that the issue was a „design and construction fault‟, with the „box gutter, flashing and sump design…overflowing during heavy rain periods due to the high volume o f water…particularly given the above roof downpipe discharging onto affected area‟. In their report, PA also noted the complainant had said the original builder had previously tried to fix the issues, but that had not been done correctly, and the home building warranty period had now expired. The insurer denied the claim on the basis that the proximate cause of the damage was not the storm event in December 2017, but instead structural defects, faulty design or faulty workmanship. C omplainants’ plumber /building inspection reports do not assist The complainants engaged an independent plumber (QC), to assess the damage. QC provided two reports dated 27 March 2019 and 3 May 2019. QC found issues such as gaps in silicone, loose cladding, missing flashing and severe water damage above the west facing window, with water entering the wall space. I consider those issues, on balance, represent faulty design and/or faulty workmanship, compounding by a likely lack of maintenance. The complainants say that after QC applied silicone over the area above the window that was leaking, there was no further leaking. The complainants also specifically commented that that „was a great relief after years of leaking through the sealing‟. I consider that also reasonably indicates the issues have been long-term. They believe this work to the window area shows that BP‟s findings (about the box gutter being the problem) are wrong. The complainants have said the gutter and water leaks are about 3 metres apart. It is worth noting, however, that the independent building inspector (IB) engaged by the complainants recommended in his report (dated 15 May 2019) that the balcony gutter be upgraded to a larger size in order to avoid further overflow issues during adverse weather conditions. IB concluded the water damage was „ purely due to storm activity occasioned around 19 December 2017 ‟. They did no t explain, however, how they reached the conclusion Determination | Case number: 622094 Page 4 of 5 that in the preceding twenty years since the building was constructed, it was that single storm event which was responsible for the damage identified in the loungeroom ceiling (below the balcony), the balcony flooring and arising from the balcony gutter backflow. Issues with water ingress before the 2017 storm The complainants had previously lodged a claim in April 2011. The insurer‟s claim notes from 2011 identify damage to the roof, ceiling, windows, flooring and furniture. In the course of that investigation, builders LBG assessed the damage and reported: > the gutters have no overflow system and the rain entered into the ceiling > suggest the insured either install over flows or as the dwelling is under sevens [sic] years old go back to original builder and they may do that for them. LBG‟s quote for the necessary repair work refers to the complainants reporting „the upstairs third level balcony over flowed causing internal damage to plaster ceiling in family room‟. That claim was declined on the basis of faulty workmanship. The insurer‟s assessment notes from 27 December 2017 (referring back to the 2011 claim) state that the complainant told the assessor the house had been under warranty up to 2015 and the builder had tried to fix the issue but was unsuccessful. The complainants have elsewhere said the 2011 water leak was fixed by the builder, and that there were no further leaks until December 2017. The complainants say the 2011 issues were in a different location and for a different reason, however the available evidence does not appear to support that. The complainants also suggest the plumber BP was not qualified to comment on structural defects or faulty design or workmanship. As well, they have said they engaged LD plumbing services to „check the storm water leak and report‟. They have not provided LD‟s report and so it is not clear what their qualifications are either, but the complainants say that report indicates the storm water was leaking over the south/south western window and not from the box gutter. In the absence of any specific or compelling evidence to support these assertions, they do not change the outcome. Whether the water was entering because of overflow from the box gutter or through openings over the window, or a combination of both, it is clear that there had been water ingress issues in 2011 which the complainants were aware of, and the evidence indicates, on balance, they had not been completely or adequately fixed. Determination | Case number: 622094 Page 5 of 5 Insurer is entitled to decline the claim I am satisfied, on the available evidence, that the water damage which had been occurring over an extended period, was more likely than not caused by structural defect or faulty design/workmanship. That means the insurer has shown exclusions apply and it is entitled to decline the claim. Recommendation Case number 622094 Financial firm QBE Insurance (Australia) Limited Recommendation | Case number: 622094 Page 1 of 8 Case number: 622094 7 August 2019 3 Overview 3.1 Complaint The complainants hold a home and contents insurance policy with the insurer. The policy responds to listed events and is subject to the terms and conditions of the policy. On 5 December 2017, the complainants lodged a claim after noticing water damage to their property. The complainants advised the insurer that water was leaking from the lounge room ceiling causing damage to the building and contents. Following assessment of the damage, the insurer declined the claim, saying the damage was due to construction defects as well as poor and faulty workmanship. The complainants dispute the declinature and are seeking for the damage to be covered by the insurer. 3.2 Issues and key findings Have the complainants established a valid claim? The policy responds to loss or damage caused by listed events in the Product Disclosure Statement (PDS). There is no dispute that a storm occurred on or around 2 December 2017 and as such, I am satisfied the complainants have established a valid claim. Is the insurer entitled to decline the claim? The available evidence indicates the damage to the complainant‟s ceiling has been occurring since as early as April 2011 and was caused as result of the exclusions relied upon by the insurer. Accordingly, I am satisfied the insurer is entitled to decline the claim. 3.3 Recommendation The recommendation is in favour of the insurer. The insurer is not required to take any further action. Recommendation | Case number: 622094 Page 2 of 8 4 Reasons for recommendation 4.1 Have the complainants established a valid claim? The complainants have onus to establish a claimable loss The complainants carry the initial onus to establish any loss or damage arising from an event which is covered under the terms and conditions of the policy. This is known as establishing a valid claim. Once this is established, the onus shifts to the insurer to show, on the balance of probabilities, the loss claimed falls within an exclusion of the policy or it is otherwise entitled to decline the claim. Policy covers storm and water/liquid damage The policy covers loss and damage caused by storm (including a named cyclone), rainwater, flood or wind. The policy also covers loss and damage caused by water or liquid escaping from a fixed gutter. Complainants have established a valid claim There is no dispute between the parties that a storm occurred on or about 2 December 2017. Therefore, the complainants have established a valid claim and accordingly, the onus rests with the insurer to establish it is entitled to decline the claim based on policy exclusions. 4.2 Is the insurer entitled to decline the claim? The insurer says the cause of the loss is excluded The insurer says that it appears that the subject damage to the complainants‟ unit has occurred over an extended period of time and is due to a combination of structural defect, faulty design or fault workmanship. For these reasons, the insurer has declined the claim. The policy excludes loss or damage caused by the above listed events when water enters a building:  Because of a structural defect, faulty design, or faulty workmanship. The policy also excludes loss or damage which is caused directly or indirectly by erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear. Recommendation | Case number: 622094 Page 3 of 8 Assessment identified maintenance issues Following notification, the insurer appointed a building assessor (PA), to assess the damage. PA arranged for a roofing plumber (BP) to attend the complainants‟ property and undertake an assessment of the roof to locate the source of the leak. On 20 June 2018, BP reported:  whilst undergoing a site inspection a spray test was taken out around the down pipe discharge and sump pickup for the box gutter on the balcony  spray test was conducted with hot water so that leak couple [sic] be detected with thermal image camera  whilst spraying rendered wall and box gutter leak occurred on thermal imaging camera from underneath. BP recommended to reseal all joints and pull up rest of timber balcony to assess the balcony. Following BP‟s attendance, PA provided a further report dated 27 June 2018, which noted that the water entry points are maintenance related and the complainants are responsible for repairing these issues. Further, PA advised that these works would be required prior to the resultant damage being repaired. Finally, PA stated: due to the roof being covered with the balcony deck boards the Insured would not have been reasonably aware of any issues until the water damage was seen inside. Based on the above findings, the insurer denied the claim on the basis that the proximate cause of the damage was not the insured event in December 2017, but rather the damage was caused by structural defects, faulty design or faulty workmanship. The complainants’ plumber says loss caused by storm In response to the insurer‟s denial, the complainants engaged an independent plumber (QC), to assess the damage. QC has provided two reports dated 27 March 2019 and 3 May 2019. In its first report, QC noted that the suspect area where the water was entering the roof space was found where the cladding meets the timber stop end. It observed large gaps in silicone and loose cladding on the west facing wall and water disappearing into the wall. In its second report, QC reported :  visual inspection and testing found severe water damage to timber frame above west facing window caused by failed seal / non-existent flashing on raked cladding above Recommendation | Case number: 622094 Page 4 of 8  no flashing above aluminium window frame. The complainants provided an independent building inspectors report (IB), dated 15 May 2019. IB reported: the resultant damage is purely due to storm activity occasioned around 19 December 2017. Issues with water inundation prior to 2017 Prior to the current complaint, the complainants lodged a claim in or around April 2011 from damage to the plaster ceiling in the family room. During investigation of this claim the insurer appointed LBG to assess the damage. At that time, LBG reported:  the gutters have no overflow system and the rain entered into the ceiling  suggest the insured either install over flows or as the dwelling is under sevens [sic] years old go back to original builder and they may do that for them. Based on LBG‟s report it is evident that the complainant was aware that the damage to the ceiling was occurring as early as April 2011. Further, the assessment report notes from 27 December 2017, state that the insured told the assessor the house had been under warranty to 2015 and the builder tried to fix the issue but was unsuccessful. Cause of loss excluded IB‟s report has been consid ered with the other expert opinions. While I am sympathetic for the complainants‟ loss, I am persuaded by QC‟s conclusions that the damage was caused by a failed seal and non-existent flashing on the raked cladding and no flashing above aluminium window frame. Further, QC notes that there is severe water damage indicating the loss had been occurring for an extended period of time. This supports the insurer‟s position that this has been an ongoing leaking issue, and it is due to faulty construction and inadequate repairs. Insurer is entitled to deny the claim Based on the available material and expert reports, the damage caused to the complainants‟ ceiling is a result of structural defect, fault design or faulty workmanship at the complainants‟ property. Recommendation | Case number: 622094 Page 5 of 8 Accordingly, the insurer has established and is able to rely on the policy exclusions to decline the claim. 5 Supporting information 5.1 ACFA approach There has been a full exchange of relevant material between the parties and each party has had the opportunity to address the issues raised. I have reviewed and considered all the material provided by the parties. While the parties have raised various issues in their submissions, for the purpose of this recommendation, commentary is restricted to only those issues considered relevant. 5.2 Relevant Policy terms Page Product Di sclosure Statement – 29 February 2016 Page 9 – Building cover includes  A hotel, motel, nursing home, boarding house, display homes, buildings of flats or units (strata title or company title) or buildings subject to community title.  A building or structure in the course of construction, substantial alteration or repair, or being demolished  Building materials to be installed. Page 13 – storm, rainwater, flood or wind Building We will cover Loss or damage as a result of:  Storm (including named cyclone)  Rainwat er  Flood, or  Wind. We won’t cover Water entering your buildings:  Through an opening made for any building, renovation or repair work;  Because of a structural defect, faulty design or faulty workmanship Page 15 – water or liquid damage building We will cover Loss or damage caused by water or liquid escaping from: Recommendation | Case number: 622094 Page 6 of 8 Page Product Di sclosure Statement – 29 February 2016  a fixed pipe or an object attached to a pipe, fixed gutter, fixed tank or a drain  a bath, basin, sauna, spa, shower base or shower wall, sink, toilet or tiled floor that has drainage holes  a washing machine or dishwasher  an aquarium  a waterbed  a swimming pool  a standalone water tank. Cost of finding where the water or liquid escaped from, including the cost of repairing any damage that occurs while looking for the cause. We won’t cover Your buildings for loss or damage caused by water or liquid entering your buildings:  Through an opening made for any building, renovation or repair work;  Because of a structural defect, faulty design or faulty workmanship Cost of repairing the item from which the water or liquid escaped. Page 30 – storm, rainwater, flood or wind contents We will cover Loss or damage as a result of:  Storm (including named cyclone)  Rainwat er  Flood, or  Wind. We won’t cover Water entering your buildings:  through an opening made for any building, renovation or repair work;  because of a structural defect, faulty design or faulty workmanship Page 31 – water or liquid damage contents We will cover Loss or damage caused by water or liquid escaping from: Recommendation | Case number: 622094 Page 7 of 8 Page Product Di sclosure Statement – 29 February 2016  a fixed pipe or an object attached to a pipe, fixed gutter, fixed tank or a drain  a bath, basin, sauna, spa, shower base or shower wall, sink, toilet or tiled floor that has drainage holes  a washing machine or dishwasher  an aquarium  a waterbed  a swimming pool  a standalone water tank. Cost of finding where the water or liquid escaped from, including the cost of repairing any damage that occurs while loo king for the cause. We won’t cover Your buildings for loss or damage caused by water or liquid entering your buildings:  Through an opening made for any building, renovation or repair work;  Because of a structural defect, faulty design or faulty workmanship Cost of repairing the item from which the water or liquid escaped. Page 40 – Exclusions We will not pay for any loss or damage which is caused directly or indirectly by: ….  erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear …. 5.3 Expert Reports Record Key points Insurer’s building asse ssor Report 14 April 2011  the gutters have no overflow system and the rain entered into the ceiling  the insured either install over flows or as the dwelling is under sevens [sic] years old go back to original builder and they may do that for them Insurer’s roofing plumber Report 20 June 2018  whilst undergoing a site inspection a spray test was taken out around the down pipe discharge and sump pickup for the box gutter on the balc ony Recommendation | Case number: 622094 Page 8 of 8 Record Key points  spray test was conducted with hot water so that leak couple [sic] be det ected with thermal image camera  whilst spraying rendered wall and box gutter leak occurred on thermal imaging camera from un derneath. Insurer building asse ssor Report 27 June 2018  insured will need to ensure the roof below the balcony is sealed and water tight prior to resultant damage repair starting.  water entry points are maintenance related and the insured is responsible to remedy these issues.  due to the roof being covered with the balcony deck boards the Insured would not have been reasonably aware of any issues until the wat er damage was seen inside. Complainants’ plumber Report 27 March 2019  found suspect area where cladding meets timber stop end.  large gap in silicone and loose cladding on west facing wall above and south of window.  Performed leak testing using water, found water “disappearing” into wall but unable to observe water inside window. Complainants’ plumb er Report 3 May 2019  visual inspection and testing found severe wat er damage to timber frame above west facing window caused by failed seal / non - existent flas hing on rak ed cladding above.  There is also no flashing above aluminium window frame. Complainants’ Independent Building Inspector Report 15 May 2019  The resultant damage is purely due to storm activity occasioned around 19 th December 2017 where thunderstorms produced wind gusts exceeding 90 kilometres per hour from the southern part of Aus tralia.  Is in our opinion due to storm activity resulting in the damaged lounge ceiling.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.