Home / Financial Firm (Unknown - Insurer) / Determination 618063

Determination 618063

Claim declined for garage ceiling collapse under gradual deterioration exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2019-07-17
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant claimed under her home building policy after her garage ceiling collapsed. The insurer declined the claim under the gradual deterioration and wear and tear exclusion, and AFCA agreed.

On the balance of expert evidence the proximate cause was long-term factors, which fall within the policy exclusions for gradual deterioration and wear and tear.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination | Case number: 618063 Page 1 of 7 Determination Case number: 618063 17 July 2019 1 Determination overview 1.1 Complaint The complainant holds a home building insurance policy underwritten by the financial firm (the insurer) covering her home address. On 3 June 2018, the garage ceiling collapsed, and the complainant subsequently lodged a claim under the policy for the repairs required. The complainant stated the high winds present on the day of the loss was the cause of the ceiling failure. After considering the claim, the insurer concluded the collapse of the ceiling was due to a combination of factors, all of which were long term. As loss of this nature is specifically excluded from cover under the policy, the insurer declined the claim. 1.2 Issue and key findings Was the insurer entitled to decline the claim? The insurer was entitled to decline the claim because the material shows that, on balance, the failure was due to a combination of factors, all of which were long term in nature. As the policy specifically excludes loss or damage arising from gradual deterioration and wear and tear, the exclusion operates to defeat the claim. 1.3 Determination This determination is in favour of the insurer. The insurer was entitled to decline the claim and is not required to take any further action. Determination | Case number: 618063 Page 2 of 7 2 Reasons for determination 2.1 Was the insurer entitled to decline the claim? Complainant has established a prima facie claim It is accepted insurance law that the complainant carries the initial onus of proving that an insured event has occurred. This is known as a prima facie claim. The insurer’s policy is an accidental damage policy. However, coverage is subject to exclusions and limitations. Accidental damage is generally held to be damage which is sudden and unforeseen. It is only once the complainant has established a prima facie claim, that the onus shifts to the insurer if it wishes to deny the claim by way of an exclusion under the policy or on some other basis. There is no dispute the garage ceiling collapsed, which was sudden and unforeseen. Accordingly, the complainant has established a prima facie claim under the terms of the policy and the insurer must now establish it is entitled to decline the claim. Proximate cause of the loss must be a covered event When considering whether a policy exclusion applies to defeat the claim, or there is some other basis on which a loss is not covered, it is appropriate to first determine the proximate cause of the loss. The proximate cause of the loss is a question of fact depending upon the circumstances in each case. It is well established at law that a proximate cause is not necessarily the first or the last or the sole cause of the loss. It is the effective or dominant or operative cause of the loss. If there are several causes operating contemporaneously, then each must be examined for the qualities of predominance and efficiency as the active, efficient cause that sets a relevant train of events in motion. Courts have said that if one cause would have resulted in the harm in any case and the other would not have done so in the absence of the first, then the first is the proximate cause. Insurer says loss caused by long term factors The insurer appointed builder ‘UB’ to inspect the property and provide an opinion as to the cause of the loss. Details of the expert reports provided are contained within section 3.2 of this determination. UB considered the cause of the failure was due to the faulty installation of the plasterboard. UB noted there was no sarking, moisture barrier paint or insulation used. This meant the ceiling was subject to moisture absorption, which led to its eventual collapse. UB considered the cause of the failure was due to the faulty Determination | Case number: 618063 Page 3 of 7 installation of the ceiling, which did not comply with the building standards applicable at the time. The insurer also appointed building consultant ‘CR’ to comment on the cause of the loss. CR considered the damage was due to a combination of factors, all of which had acted in conjunction to cause the failure. CR considered the long-term factors of the exposure of the property to varying strengths of wind and wind gusts would cause long term residual deflection of the roof trusses, including the chords to which the ceiling was attached. This deflection contributed to the failure of the physical connection between the ceiling lining and fixing points. Complainant’s expert says loss caused by high winds The complainant disagrees with the insurer’s experts , saying they did not properly inspect the property and the conclusions are flawed. She provided her own expert opinion from builder ‘SH’ in support of her position that th e damage was caused by high winds. I have considered this report as part of my review. SH disagreed with UB’s findings and said there was no requirement for there to be sarking or insulation fitted to comply with the building standards at the time of construction. SH completed moisture testing to the plasterboard noting it had no moisture reading, nor were there signs of water or moisture present. SH did not consider this to be a factor in the collapse. SH concluded the cause of the failure was the high winds on the day of the loss, which had caused a pressurised action effectively sucking the ceiling down from its fixings. Evidence of CR is preferred It is always difficult when faced with conflicting expert opinions to determine which evidence is more persuasive. After careful consideration, I prefer CR’s evidence in this matter. There are several reasons for this. Firstly, although SH attributes the damage to high winds on the day of the loss, the data from the Bureau of Meteorology shows the maximum wind speed at the nearest weather station was only 17kph. According to the Beaufort Wind Scale, wind of this speed is not of sufficient velocity to cause structural damage to a property. SH says moisture tests were conducted on the plasterboard which showed a zero reading, proving there was no moisture on the sheets. However, no evidence of these tests has been provided. Accordingly, I can place little weight on SH’s conclusions. Determination | Case number: 618063 Page 4 of 7 Similarly, UB states the cause of the failure was due to faulty installation of the ceiling and its failure to comply with the relevant building standards at the time. However, this is refuted by both CR and SH. This means UB’s report also carries less weight as a result. Failure was due to long term factors This leaves the evidence of CR for consideration. The complainant says her location regularly experiences wind speeds far in excess of those recorded at the closest weather station, including on the day of the loss. Whilst I agree the location’s elevated and bayside location mean it may experience wind speeds in excess of those recorded at the nearby weather station, there is no evidence before me to suggest what those wind speeds would be. As the only reliable data given is that from the weather station, which shows minor velocity winds on the day, there would need to be some compelling evidence presented to s how the complainant’s location nearby experienced a great variation in windspeed on the day of the loss. However, there is not. In my view, that the property is reportedly regularly affected by strong winds tends to support CR’s conclusion that the cause of the failure was due to long term deflection on the ceiling trusses, which eventually caused the failure of the attached plasterboard lining. Photographs supplied by the parties are consistent with CR’s findings. Therefore, even if it were accepted there were high winds on the day of the loss, this would not necessarily be the dominant cause of the loss. The material shows, on balance, the proximate cause of the loss was the combination of factors at the site including ongoing wind loads, high humidity build up on the metal roof sheets and the flexing of the roof trusses. All of these factors were long term factors which eventually caused the ceiling to detach and collapse. Long term factors excluded from cover Even accepting the complainant has established a prima facie claim under the policy, the policy specifically excludes loss arising from gradual deterioration and wear and tear. As the proximate case of the loss falls within the exclusions from cover, I am satisfied the exclusions from cover would be operative in the circumstances. On this basis, the complainant has not established she suffered a loss which is covered by the policy terms and the insurer was entitled to decline the claim. Determination | Case number: 618063 Page 5 of 7 3 Supporting information 3.1 AFCA approach to this dispute This complaint has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous decisions of AFCA or its predecessor schemes (which are not binding). A full exchange of the relevant information has taken place between the respective parties. Each party has had the opportunity of addressing any issues raised. All of the provided material has been reviewed and considered. The parties have raised numerous issues in their submissions to AFCA. However, commentary in this determination is restricted only to those issues considered relevant to the outcome. 3.2 Relevant expert reports Record Key points Insurer’s expert ( UB ) Builder’s Report 5 June 2018  inspection revealed the garage ceiling had collaps ed and detached from its fixing points  inspection of the ceiling cavity showed no sarking installed to prevent moisture from dropping onto the plaster sheets  no ceiling ins ulation had been installed either, which also acts as a mo isture barrier  the ceiling has also been painted with flat paint which is not a moisture barrier  the damage is consistent with moisture absorption due to high humidity over time  the plaster has weakened over time due to the moisture absorption to the point where the plasterboard has softened, and pulled out the fixtures  as one section fails, additional load is transferred to the remaining sections, causing them to also fail  the damage is due to faulty workmanship/ poor installation. Complainant’s expert ( SH ) Builder’s Report 7 July 2018  there were no signs of water ingress to the ceiling which could have caused the collaps e  there were no other signs of damage to the premis es  there were no humidity damage, condensation or water marks  the stud adhesive had s eparated itself from the roof cavity side of the plaster  the only possible cause of the failure was due to high winds causing a low pressure which would suck the ceiling out  this was not caused by a lack of ins ulation. Complainant’s expert ( SH ) Builder’s Report 25 September 2018  the ceiling was installed correctly  although the standards have since altered, the ceiling was installed in accordance with the standards applicable at the time Determination | Case number: 618063 Page 6 of 7 Record Key points  there was no sign of deterioration in the plaster or any signs of fungus growth that could be caused by humidity  moisture tests on the plaster were performed, which showed a zero reading  roof trusses are designed to flex as one unit; therefore, the plaster will move as one and not individually  the movement of th e trusses has not caused the failure of the ceiling  the cause of the collaps e was due to extremely high winds on the day which has caused positive pressure in the ceiling space, resulting in the collapse  even though the garage door opening causes a vacuum reaction, the high winds were the cause as the ceiling had stood for 15 years prior. Insurer’s expert ( UB ) Supplement ary Report 28 June 2018  the current building regulations have been in place for 20 years and there would have been a requirement for sarking in 2002 when he home was constructed  there has been no defined event which has caused the ceiling to collapse  it is possible if there was sarking in place, moisture absorption would still occur due to the area being a garage with no insulation and painted with flat paint which is not a moisture barrier. Insurer’s expert ( CR ) Building Consultant Report 28 August 2018  the residence is a single story, brick veneer construction on a concrete slab  it was built in 2003 and is in good condition  the property is located approximately 3km from Port Phillip Bay  the property is located at a high point in the terrain and is often subject to high winds  inspection of the roof space showed the plaster was fixed to a metal furring channel, which had been screw fixed to the bottom chords of the roof channel  inspection of the ceiling lining showed it was deficient in some aspects however the lack of back blocking had not been a causation factor in the collapse  condensation was noted on the undersides of the metal roof sheets however no signs of wat er was noted to the plasterboard sheeting  no sarking had been installed however this was not a mandat ory requirement in this instance, nor was the installation of insulation  notwithstanding the above, humidity and conden sation build up in the roof spac e above the garage can lead to dilapidation of the ceiling lining and can weaken its structural integrity at the fixing points  on the date of loss, the humidity was relatively high at 96% whereas the wind speed was low at 17 kph  given the exposed location of the dwelling and prevalent wind direction, the garage including the roof frame trusses would be Determination | Case number: 618063 Page 7 of 7 Record Key points exposed to varying strengths of wind and gusts  this would cause long term residual deflection of the roof trusses, including t he bottom chords to which the ceiling was attached  this deflection will contribute to the dilapidation of the physical connection between the ceiling lining and fixing points  the collapse is consistent with having been caused by the following contributing factors: o the plasterboard lining not having been installed strictly in accordance with the general requirements of the installation guidelines o the relative humidity within the roof space including condensation build up o residual flexing of the roof trusses which support the ceiling lining o the topographical area in which the residence is constructed and the resultant wind and wind gusts o the common use of the automatic panel lift door of the garage  all of which have caused the premature dilapidation of the ceiling lining leading to its event ual collaps e.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.