Home / Allianz Australia / Determination 616568
Determination 616568
Storm water damage claim declined under inherent defects exclusion
Summary
The complainant's home suffered storm water damage to the ceiling and contents, and the insurer declined the claim for inherent roof defects. AFCA found the defects were the proximate cause and the exclusion applied.
Proximate cause is the dominant effective cause, and the expert evidence established that roof design and construction defects, not the storm, caused the water entry.
Issues
- Claim denial primary · not upheld“the insurer is entitled to decline the claim.”
- Product terms interpretation secondary · not upheld“even if I were to accept this argument, it is redundant in view of the other policy exclusion relied on by the insurer.”
Subjects and remedies
home or building damagenatural disasterno remedy
Related
All Allianz Australia determinations · Find similar determinations
Text of the determination
Determination
Case number 616568
Financial firm Allianz Australia Insurance Limited
Determination | Case number: 528118 Page 1 of 10
Case number: 616568 3 October 2019
1 Determination overview
1.1 Complaint
The complainant lodged a claim for damage with the financial firm (the insurer)
following a storm in March 2018.
The insurer declined the claim because it says the damage is a result of inherent
defects, which are specifically excluded under the policy. It also says there were no
storm created openings on the roof, as required under the policy.
The complainant says the home is six years old and had been through previous
storms where no damage occurred. The complainant contends this indicates that a
minor issue with the pitch of the roof was not the proximate cause of the loss and the
insurer is liable for the claimed damage.
The case manager provided the parties with a preliminary assessment on the issues
in dispute. The preliminary assessment was in favour of the insurer.
As the complainant did not accept the preliminary assessment, the complaint has
been referred to me for determination .
1.2 Issues and key findings
Is the insurer entitled to decline the claim?
The available material establishes on the balance of probabilities the proximate cause
of the claimed damage was inherent defects in the design and construction of the
roof. As this cause of damage is excluded from cover, the insurer is entitled to decline
the claim.
1.3 Determination
This determination is in favour of the insurer.
The insurer is not required to take any further action in relation to the claim or the
complaint.
Determination | Case number: 528118 Page 2 of 10
2 Reasons for determination
I have decided this complaint based on what is fair in all the circumstances, having
regard to legal principles, applicable industry codes or guidance, good industry
practice and previous relevant determinations of Australian Financial Complainants
Authority (AFCA) or predecessor schemes (which are not binding). I have considered
all the material submitted by the parties, both before and after the preliminary
assessment. I am satisfied that the documentation I have relied on has been provided
to both parties.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues considered
directly relevant to the outcome only.
The complainant is represented. For ease of reference and brevity, reference in this
determination to the complainant includes reference to the complainant’s
representative.
No new material provided after the preliminary assessment
After the preliminary assessment was rejected, neither party made further
submissions or provided new material.
2.1 Is the insurer entitled to decline the claim?
Storm water entered the home and damaged contents
The complainant must establish on the balance of probabilities he has suffered a loss
caused by the storm event. This is known as a prima facie claim.
It is not in dispute on 6 March 2018 water entered the complainant’s home and
damaged the building and contents. I am satisfied the complainant has established a
prima facie claim.
Insurer must establish an exclusion applies
Once so established, the onus shifts to the insurer to prove on the balance of
probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss.
The complainant argues the insurer has excessively focused on some minor non-
compliance with the pitch of the roof rather than that the effect of the storm driven
wind and heavy rain which damaged the complainant’s contents. He says there was a
severe storm with 60mm of rain and strong wind.
He notes the house is six years old and since it was built, there were many storms,
but no evidence of previous water ingress. He relies on an expert report from his
Determination | Case number: 528118 Page 3 of 10
builder to support his contention the construction of the roof was sufficient to handle
normal wet weather.
The complainant refers to the insurer’s expert reports which refer to a small gap of
about 30mm left between the roof sheets and the flashing downturn. The complainant
says if water entered through this opening then it is minor and did not allow water to
enter the building on other occasions. Therefore, he argues the minor non-compliance
in the roof construction was not the proximate cause of the loss.
The complainant also contends policy interpretation rules operate in his favour. He
submits t he meaning of ‘other opening’ in the exclusion clause relied on by the insurer
should be restricted to the kind of items listed and not small gaps which allow water to
enter in extreme weather events.
He also says the fact the roof pitch was lower than recommended may have
contributed to ponding of water on the roof, but it was not the proximate cause. He
says water entered the building because of the severity of the storm characterised by
severe winds and heavy rain falling in a short period of time.
He also says the insurer should pay his claim for his damaged contents because the
building insurer paid for the damage to the building.
Expert opinions were provided and considered
The insurer relies on the expert report from a builder who says because of building
defects in the roof installation, water ponded and entered the building. The insurer
says water entered the home and damaged the contents through an opening which
was not caused by the storm. Notwithstanding the nature of the storm event, the
insurer says its expert opinion is that if the roof was compliant with industry standards ,
it would have been able to withstand the reported storm event.
The expert reports are summarised in supporting section 3 this determination. Also
included is an extract from a roofing report obtained by the building insurer.
The policy provides cover for damage caused by storm.
Damage is not covered if caused by rainwater, run-off, hail, wind or water entering the
building through an open door, window or other opening (excluding openings made by
the storm).
Damage is also not covered if it is because of, caused by or arising from inherent
defects including faulty design, structural defects or poor workmanship.
Determination | Case number: 528118 Page 4 of 10
Proximate cause of damage was inherent defects in the roof
I have carefully considered the material provided by the parties.
The building insurer engaged a roofing contractor. This roofing contractor identified
both the lower and upper roof were under pitched and during the downpour , water
would have backed up and tracked back into the roof.
The insurer’s builder also identifies this issue and other issues with the roof and its
construction. He also concludes the low roof pitch on the lower level lounge room and
the way the metal flashing was installed to the gutter end of the roof sheet allowed
water to pond on the roof surface. Thus, resulting in water tracking into the roof void
eventually depositing on the plaster ceiling lining of the lounge room and causing the
claimed damage.
As for the upper level bedroom, not only did he identify the same issue with the low
roof pitch, but he also identified gaps at the ridge end of the metal roof sheeting and
concluded wind driven ponding water tracked into the northern wall cavity to the upper
level bedroom causing the claimed damage.
The insurer’s builder has provided three reports. The reports are detailed and
supported by photographs. I accept he persuasively rebuts the opinion of the
complainant’s builder. In any event, he says if the gutt ers were unable to hold the high
volume of rainwater (as identified by the complainant’s builder) this was also defective
building work because high fronted stormwater guttering had not been installed with
an overflow measure as required by the relevant building code.
As for the contention that the rainfall event was extremely heavy and had not been
adequately considered by the insurer, the insurer’s builder said wind and rain at the
relevant time was well within the design parameters of a metal roof syste m in the area
if designed and constructed in accordance with the building code. If the roof was
compliant he says it would have accommodated the rainfall and would not have
allowed water to enter the building.
Both the building insurer’s roofing contractor and the insurer’s builder identify defects
with the design and construction of the roof. I consider the opinion of the
complainant’s builder has been effectively and comprehensively rebutted by the
insurer’s b uilder whose reports are comprehensive, address relevant building codes
and are supported by photographs.
I am not satisfied the available material establishes water entered the building
because of the severity of the storm. Rather, I am satisfied the available information
establishes the dominant or effective cause of the loss (the proximate cause) were
the building defects identified in the insurers’ expert reports.
Determination | Case number: 528118 Page 5 of 10
The insurer is entitled to decline the claim
The complainant has argued about the interpretation of the policy. However, even if I
were to accept this argument, it is redundant in view of the other policy exclusion
relied on by the insurer.
The complainant argues the insurer should pay because the home building insurer
paid for the damage to the building. There may be many reasons why the home
building insurer paid the claim. However, this determination is based on the insurer’s
policy terms and the material provided by the parties. In view of those policy terms
and the material provided, I do not find this argument persuasive.
I am satisfied the available information establishes on the balance of probabilities the
claimed damage is caused by inherent defects in the roof. As this cause of damage is
excluded from cover, the insurer is entitled to deny the claim.
The insurer need take no further action in relation to the claim or the complaint.
Determination | Case number: 528118 Page 6 of 10
3 Supporting information
3.1 Our Approach
It is an accepted principle of general insurance law that the insured bears the onus to
establish on the balance of probabilities that they have suffered a loss caused by an
event to which the policy responds. This is known as a prima facie claim. Once so
established, the onus shifts to the insurer to prove on the balance of probabilities that
an exclusion applies if it seeks to deny or limit its liability for the loss.
3.2 Relevant policy terms
The relevant policy extracts are referred to in the correspondence between the parties
and in the insurer’s Notice of Response. Both the policy document and the Notice
have been exchanged with the complainant.
3.3 Case law and proximate cause
Case law establishes:
The proximate cause of the loss is the dominant or effective or operative cause of
the loss whether or not that be the last in time or the sole cause.
If there are several causes operating contemporaneously, each must be examined
for the qualities of reality, predominance and efficiency as the active, efficient
cause that sets a relevant chain of events in action. If one cause would have
caused the harm in any case and the other would not have done so in the absence
of the first, the first is the proximate cause.
A common-sense approach is taken to determine proximate cause.
3.4 Extracts from expert reports
Date Action
Insurer’s adjuster report
28 March 2018
Attended and photographed 21 March 2018.
Complainant purchased the property two years ago
from owner builder. Pre - purchase report not located.
Property completed in 2012.
Severe storm accompanied by strong winds and heavy
rain (more than 60mm rain falling in a half hour).
Complainant said never had any water ingress
problems during heavy rain before.
Water poured through the downlights in the living room
and c eiling collapsed and damage d contents.
Water ran into the next room but was stopped by a rug
and ran down the hallway into the master bedroom
downstairs.
Upstairs water entered the front window and wall
Determination | Case number: 528118 Page 7 of 10
Date Action
wetting the carpet.
Extract from building insurer’ s
roofing report ( CR )
Lower trim deck roof is under pitched. The minimum
pitch for this roof profile is 2°. In some areas the roof
pictures less than 1°.
Roof over ent ry is sufficiently pitched at 6.3° but the
flashings are roughly installed and there are cracks in
the claddin g which take wat er during heavy rain.
Baffle flashing too close to the end of the roof sheets.
This may have slowed the water flow into the gutter
during the downpour.
Upper roof has a big flat spot in the roof which holds
water. Roof has a large bow on it. Roof is under 1°
pitch which is the limit for K sheeting. During rain,
water would have backed up and tracked back into the
roof.
Insurer’s adjuster email
6 April 2018
Water ingress is because of excessive rain water run -
off being unable to clear t he roof because of several
the building defects listed above.
Water ingress is not due to strong winds driving the
water into the home.
Insurer’s builder report (S)
23 April 2018
Inspected and photographed the building and roof on
19 April 2018. Photographs are annotated in support of
the builder’s statements in the report.
Reviewed CR ’s report.
Noted damage in lower level lounge room. Room
covered by C olourbond metal roof sheets.
Pitch / slope of the roof 0.7° to 1°. Roof has a negative
pitch of .5 ° away from the guttering causing water to
pond on the roof to a depth of about 10mm.
Relevant i nstallation code required minimum pitch of
2°.
90° met al flashing installed to the gutter end of the roof
sheets. A small gap (30mm) has been left between the
e dge of the roof sheets and the flas hing downturn that
extends into the stormwater gutter.
Flashing significantly reduc es the effective discharge
of water crossing down the surface of the roof sheeting
during rain.
Because of the low roof pitch and the inst allation of the
flashing this allowed water to pond on the roof surface
resulting in water tracking over the side laps of the
sheets and into the roof void depositing on the
plasterboard ceiling of the lounge room and causing
the damage.
Installation of th e metal sheets on a roof with a pitch
less than 2° is defective work.
Determination | Case number: 528118 Page 8 of 10
Date Action
Inspected damage in the upper level bedroom and
noted the bedroom roof is covered with Colourbond K
profile metal sheets.
Likely securing clips are not fitted tightly to the
underside o f the roof sheets.
Pitch/slope of roof ranges from 0.2° to 0.4°.
Roof has a negative pitch of 0. 6° away from the
stormwat er guttering causing water to pond on the
sheeting to a depth of about 10mm.
Relevant installation code recommends minimum pitch
of 1 °.
9mm wide gaps between the downt urn of the
ridge/barge capping and the pan of the roof sheets.
Pans have been partially turned up leaving large gaps
for wind driven water to ent er the northern wall cavity
of the upper level bedroom.
Wind driven ponding water tracked int o the northern
wall cavity common to the upper level bedroom
causing damage bec ause of the low roof pitch and the
gaps at the ridge end of the profile metal roof sheeting.
Installation of these metal roof sheets on a roof with a
pitch less than 2 ° is defective building work.
Insurer’s builders report (S)
9 August 2018
Commented on the complainant’s builder’s report and
maintained his opinion.
If the stormwater guttering overflowed and caused
stormwat er to flow back on the roof as alleged, then
this is also defective building work as the high fronted
stormwat er guttering has not been installed wit h an
overflow measure as required by the building code
relevant at the time of construction.
Irrespective of whether the stormwater gutter ing
overflowed causing storm water to flow back on the
roof, because of the negative roof pitches, overflowing
stormwat er guttering would have only contributed to
water ponding on the metal roof sheets surface.
Insurer’s builders report (S)
3 October 2018
Provided further photographs and ans wers to insurer’s
questions about the volume of rain and design faults .
Rainfall intensity of a location must be considered
within the design parameter of a metal roof system
prior to installation
Rainfall event of 6 0mm well wit hin the design
parameters of a metal roof system constructed in the
area if designed in accordance with the building code.
If the metal roof system was compliant it would
accommodate 60mm of rainfall and would not allow
water to enter the build ing.
Irrespective of when or whether wind driven ponding
Determination | Case number: 528118 Page 9 of 10
Date Action
water tracked into the northern wall cavity, the water
entry point contravenes the Construction Code and the
water entry is the result of defective building work.
Large rain during February 2018 is likely the cause of
the damage which became apparent in March 2018.
Confirm s points of water ingress to the upper and
lower levels of the house are not the result of the storm
related opening.
Confirm s if the metal roof system of the house was
designed a nd constructed in accordanc e with the
relevant Code for metal roof and wall cladding ponding
rainfall would not have entered the upper and lower
levels of the house.
Failure to install fixed overflows of similar size or larger
than the downpipe connected to the stormwat er
guttering is defective building work .
Details and reiterates design faults and defective
building work in the roof of lower - level lounge room
and upper level bedroom including ponding, barge
capping, end stopping and turnup sheets.
Confir ms his opinion water entered the house as a
direct result of these defects.
Complainant’s builder report
( O )
30 May 2018
O constructions (local carpentry and construction
business) repaired the storm damaged property.
Damage caused by water ingress becau se of the
severe storm event due to the gutters being unable to
hold the high volume of water. Water backfilled on the
roof and ent ered the ceiling space.
When repairing noted no previous water ingress.
Damage becaus e of severe storm event rather than a
de fect or design fault because if there was a defect
issue then water would have been a continuing
problem but there was no evidence of previous water
ingress.
During repairs undertook a comprehensive water test
using a high - pressure hose and the water flowe d well
into the gutters without ponding. No water came into
the house. Pitch of the roof is sufficient to handle
normal wet weat her.
After repairs, no water ingress during normal rain
events.
3.5 Other relevant material considered and relied on
p arties’ submissions/emails and all attachments to all submissions/emails
Determination | Case number: 528118 Page 10 of 10
p arties’ expert reports
photographs
correspondence between the parties.