Home / Allianz Australia / Determination 616568

Determination 616568

Storm water damage claim declined under inherent defects exclusion

FirmAllianz Australia
Decided2019-10-03
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant's home suffered storm water damage to the ceiling and contents, and the insurer declined the claim for inherent roof defects. AFCA found the defects were the proximate cause and the exclusion applied.

Proximate cause is the dominant effective cause, and the expert evidence established that roof design and construction defects, not the storm, caused the water entry.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Allianz Australia determinations · Find similar determinations

Text of the determination

Determination Case number 616568 Financial firm Allianz Australia Insurance Limited Determination | Case number: 528118 Page 1 of 10 Case number: 616568 3 October 2019 1 Determination overview 1.1 Complaint The complainant lodged a claim for damage with the financial firm (the insurer) following a storm in March 2018. The insurer declined the claim because it says the damage is a result of inherent defects, which are specifically excluded under the policy. It also says there were no storm created openings on the roof, as required under the policy. The complainant says the home is six years old and had been through previous storms where no damage occurred. The complainant contends this indicates that a minor issue with the pitch of the roof was not the proximate cause of the loss and the insurer is liable for the claimed damage. The case manager provided the parties with a preliminary assessment on the issues in dispute. The preliminary assessment was in favour of the insurer. As the complainant did not accept the preliminary assessment, the complaint has been referred to me for determination . 1.2 Issues and key findings Is the insurer entitled to decline the claim? The available material establishes on the balance of probabilities the proximate cause of the claimed damage was inherent defects in the design and construction of the roof. As this cause of damage is excluded from cover, the insurer is entitled to decline the claim. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to take any further action in relation to the claim or the complaint. Determination | Case number: 528118 Page 2 of 10 2 Reasons for determination I have decided this complaint based on what is fair in all the circumstances, having regard to legal principles, applicable industry codes or guidance, good industry practice and previous relevant determinations of Australian Financial Complainants Authority (AFCA) or predecessor schemes (which are not binding). I have considered all the material submitted by the parties, both before and after the preliminary assessment. I am satisfied that the documentation I have relied on has been provided to both parties. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. The complainant is represented. For ease of reference and brevity, reference in this determination to the complainant includes reference to the complainant’s representative. No new material provided after the preliminary assessment After the preliminary assessment was rejected, neither party made further submissions or provided new material. 2.1 Is the insurer entitled to decline the claim? Storm water entered the home and damaged contents The complainant must establish on the balance of probabilities he has suffered a loss caused by the storm event. This is known as a prima facie claim. It is not in dispute on 6 March 2018 water entered the complainant’s home and damaged the building and contents. I am satisfied the complainant has established a prima facie claim. Insurer must establish an exclusion applies Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. The complainant argues the insurer has excessively focused on some minor non- compliance with the pitch of the roof rather than that the effect of the storm driven wind and heavy rain which damaged the complainant’s contents. He says there was a severe storm with 60mm of rain and strong wind. He notes the house is six years old and since it was built, there were many storms, but no evidence of previous water ingress. He relies on an expert report from his Determination | Case number: 528118 Page 3 of 10 builder to support his contention the construction of the roof was sufficient to handle normal wet weather. The complainant refers to the insurer’s expert reports which refer to a small gap of about 30mm left between the roof sheets and the flashing downturn. The complainant says if water entered through this opening then it is minor and did not allow water to enter the building on other occasions. Therefore, he argues the minor non-compliance in the roof construction was not the proximate cause of the loss. The complainant also contends policy interpretation rules operate in his favour. He submits t he meaning of ‘other opening’ in the exclusion clause relied on by the insurer should be restricted to the kind of items listed and not small gaps which allow water to enter in extreme weather events. He also says the fact the roof pitch was lower than recommended may have contributed to ponding of water on the roof, but it was not the proximate cause. He says water entered the building because of the severity of the storm characterised by severe winds and heavy rain falling in a short period of time. He also says the insurer should pay his claim for his damaged contents because the building insurer paid for the damage to the building. Expert opinions were provided and considered The insurer relies on the expert report from a builder who says because of building defects in the roof installation, water ponded and entered the building. The insurer says water entered the home and damaged the contents through an opening which was not caused by the storm. Notwithstanding the nature of the storm event, the insurer says its expert opinion is that if the roof was compliant with industry standards , it would have been able to withstand the reported storm event. The expert reports are summarised in supporting section 3 this determination. Also included is an extract from a roofing report obtained by the building insurer. The policy provides cover for damage caused by storm. Damage is not covered if caused by rainwater, run-off, hail, wind or water entering the building through an open door, window or other opening (excluding openings made by the storm). Damage is also not covered if it is because of, caused by or arising from inherent defects including faulty design, structural defects or poor workmanship. Determination | Case number: 528118 Page 4 of 10 Proximate cause of damage was inherent defects in the roof I have carefully considered the material provided by the parties. The building insurer engaged a roofing contractor. This roofing contractor identified both the lower and upper roof were under pitched and during the downpour , water would have backed up and tracked back into the roof. The insurer’s builder also identifies this issue and other issues with the roof and its construction. He also concludes the low roof pitch on the lower level lounge room and the way the metal flashing was installed to the gutter end of the roof sheet allowed water to pond on the roof surface. Thus, resulting in water tracking into the roof void eventually depositing on the plaster ceiling lining of the lounge room and causing the claimed damage. As for the upper level bedroom, not only did he identify the same issue with the low roof pitch, but he also identified gaps at the ridge end of the metal roof sheeting and concluded wind driven ponding water tracked into the northern wall cavity to the upper level bedroom causing the claimed damage. The insurer’s builder has provided three reports. The reports are detailed and supported by photographs. I accept he persuasively rebuts the opinion of the complainant’s builder. In any event, he says if the gutt ers were unable to hold the high volume of rainwater (as identified by the complainant’s builder) this was also defective building work because high fronted stormwater guttering had not been installed with an overflow measure as required by the relevant building code. As for the contention that the rainfall event was extremely heavy and had not been adequately considered by the insurer, the insurer’s builder said wind and rain at the relevant time was well within the design parameters of a metal roof syste m in the area if designed and constructed in accordance with the building code. If the roof was compliant he says it would have accommodated the rainfall and would not have allowed water to enter the building. Both the building insurer’s roofing contractor and the insurer’s builder identify defects with the design and construction of the roof. I consider the opinion of the complainant’s builder has been effectively and comprehensively rebutted by the insurer’s b uilder whose reports are comprehensive, address relevant building codes and are supported by photographs. I am not satisfied the available material establishes water entered the building because of the severity of the storm. Rather, I am satisfied the available information establishes the dominant or effective cause of the loss (the proximate cause) were the building defects identified in the insurers’ expert reports. Determination | Case number: 528118 Page 5 of 10 The insurer is entitled to decline the claim The complainant has argued about the interpretation of the policy. However, even if I were to accept this argument, it is redundant in view of the other policy exclusion relied on by the insurer. The complainant argues the insurer should pay because the home building insurer paid for the damage to the building. There may be many reasons why the home building insurer paid the claim. However, this determination is based on the insurer’s policy terms and the material provided by the parties. In view of those policy terms and the material provided, I do not find this argument persuasive. I am satisfied the available information establishes on the balance of probabilities the claimed damage is caused by inherent defects in the roof. As this cause of damage is excluded from cover, the insurer is entitled to deny the claim. The insurer need take no further action in relation to the claim or the complaint. Determination | Case number: 528118 Page 6 of 10 3 Supporting information 3.1 Our Approach It is an accepted principle of general insurance law that the insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. 3.2 Relevant policy terms The relevant policy extracts are referred to in the correspondence between the parties and in the insurer’s Notice of Response. Both the policy document and the Notice have been exchanged with the complainant. 3.3 Case law and proximate cause Case law establishes:  The proximate cause of the loss is the dominant or effective or operative cause of the loss whether or not that be the last in time or the sole cause.  If there are several causes operating contemporaneously, each must be examined for the qualities of reality, predominance and efficiency as the active, efficient cause that sets a relevant chain of events in action. If one cause would have caused the harm in any case and the other would not have done so in the absence of the first, the first is the proximate cause.  A common-sense approach is taken to determine proximate cause. 3.4 Extracts from expert reports Date Action Insurer’s adjuster report 28 March 2018  Attended and photographed 21 March 2018.  Complainant purchased the property two years ago from owner builder. Pre - purchase report not located.  Property completed in 2012.  Severe storm accompanied by strong winds and heavy rain (more than 60mm rain falling in a half hour).  Complainant said never had any water ingress problems during heavy rain before.  Water poured through the downlights in the living room and c eiling collapsed and damage d contents.  Water ran into the next room but was stopped by a rug and ran down the hallway into the master bedroom downstairs.  Upstairs water entered the front window and wall Determination | Case number: 528118 Page 7 of 10 Date Action wetting the carpet. Extract from building insurer’ s roofing report ( CR )  Lower trim deck roof is under pitched. The minimum pitch for this roof profile is 2°. In some areas the roof pictures less than 1°.  Roof over ent ry is sufficiently pitched at 6.3° but the flashings are roughly installed and there are cracks in the claddin g which take wat er during heavy rain.  Baffle flashing too close to the end of the roof sheets. This may have slowed the water flow into the gutter during the downpour.  Upper roof has a big flat spot in the roof which holds water. Roof has a large bow on it. Roof is under 1° pitch which is the limit for K sheeting. During rain, water would have backed up and tracked back into the roof. Insurer’s adjuster email 6 April 2018  Water ingress is because of excessive rain water run - off being unable to clear t he roof because of several the building defects listed above.  Water ingress is not due to strong winds driving the water into the home. Insurer’s builder report (S) 23 April 2018  Inspected and photographed the building and roof on 19 April 2018. Photographs are annotated in support of the builder’s statements in the report.  Reviewed CR ’s report.  Noted damage in lower level lounge room. Room covered by C olourbond metal roof sheets.  Pitch / slope of the roof 0.7° to 1°. Roof has a negative pitch of .5 ° away from the guttering causing water to pond on the roof to a depth of about 10mm.  Relevant i nstallation code required minimum pitch of 2°.  90° met al flashing installed to the gutter end of the roof sheets. A small gap (30mm) has been left between the e dge of the roof sheets and the flas hing downturn that extends into the stormwater gutter.  Flashing significantly reduc es the effective discharge of water crossing down the surface of the roof sheeting during rain.  Because of the low roof pitch and the inst allation of the flashing this allowed water to pond on the roof surface resulting in water tracking over the side laps of the sheets and into the roof void depositing on the plasterboard ceiling of the lounge room and causing the damage.  Installation of th e metal sheets on a roof with a pitch less than 2° is defective work. Determination | Case number: 528118 Page 8 of 10 Date Action  Inspected damage in the upper level bedroom and noted the bedroom roof is covered with Colourbond K profile metal sheets.  Likely securing clips are not fitted tightly to the underside o f the roof sheets.  Pitch/slope of roof ranges from 0.2° to 0.4°.  Roof has a negative pitch of 0. 6° away from the stormwat er guttering causing water to pond on the sheeting to a depth of about 10mm.  Relevant installation code recommends minimum pitch of 1 °.  9mm wide gaps between the downt urn of the ridge/barge capping and the pan of the roof sheets. Pans have been partially turned up leaving large gaps for wind driven water to ent er the northern wall cavity of the upper level bedroom.  Wind driven ponding water tracked int o the northern wall cavity common to the upper level bedroom causing damage bec ause of the low roof pitch and the gaps at the ridge end of the profile metal roof sheeting.  Installation of these metal roof sheets on a roof with a pitch less than 2 ° is defective building work. Insurer’s builders report (S) 9 August 2018  Commented on the complainant’s builder’s report and maintained his opinion.  If the stormwater guttering overflowed and caused stormwat er to flow back on the roof as alleged, then this is also defective building work as the high fronted stormwat er guttering has not been installed wit h an overflow measure as required by the building code relevant at the time of construction.  Irrespective of whether the stormwater gutter ing overflowed causing storm water to flow back on the roof, because of the negative roof pitches, overflowing stormwat er guttering would have only contributed to water ponding on the metal roof sheets surface. Insurer’s builders report (S) 3 October 2018  Provided further photographs and ans wers to insurer’s questions about the volume of rain and design faults .  Rainfall intensity of a location must be considered within the design parameter of a metal roof system prior to installation  Rainfall event of 6 0mm well wit hin the design parameters of a metal roof system constructed in the area if designed in accordance with the building code.  If the metal roof system was compliant it would accommodate 60mm of rainfall and would not allow water to enter the build ing.  Irrespective of when or whether wind driven ponding Determination | Case number: 528118 Page 9 of 10 Date Action water tracked into the northern wall cavity, the water entry point contravenes the Construction Code and the water entry is the result of defective building work.  Large rain during February 2018 is likely the cause of the damage which became apparent in March 2018.  Confirm s points of water ingress to the upper and lower levels of the house are not the result of the storm related opening.  Confirm s if the metal roof system of the house was designed a nd constructed in accordanc e with the relevant Code for metal roof and wall cladding ponding rainfall would not have entered the upper and lower levels of the house.  Failure to install fixed overflows of similar size or larger than the downpipe connected to the stormwat er guttering is defective building work .  Details and reiterates design faults and defective building work in the roof of lower - level lounge room and upper level bedroom including ponding, barge capping, end stopping and turnup sheets.  Confir ms his opinion water entered the house as a direct result of these defects. Complainant’s builder report ( O ) 30 May 2018  O constructions (local carpentry and construction business) repaired the storm damaged property.  Damage caused by water ingress becau se of the severe storm event due to the gutters being unable to hold the high volume of water. Water backfilled on the roof and ent ered the ceiling space.  When repairing noted no previous water ingress.  Damage becaus e of severe storm event rather than a de fect or design fault because if there was a defect issue then water would have been a continuing problem but there was no evidence of previous water ingress.  During repairs undertook a comprehensive water test using a high - pressure hose and the water flowe d well into the gutters without ponding. No water came into the house. Pitch of the roof is sufficient to handle normal wet weat her.  After repairs, no water ingress during normal rain events. 3.5 Other relevant material considered and relied on  p arties’ submissions/emails and all attachments to all submissions/emails Determination | Case number: 528118 Page 10 of 10  p arties’ expert reports  photographs  correspondence between the parties.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.