Home / IAG / Determination 602642
Determination 602642
Claim denied for damage to machine controller under electronic breakdown exclusion
Summary
The insurer denied a claim for damage to a machine controller, relying on a policy exclusion for electronic breakdown. AFCA accepted the expert evidence that the damage was not caused by a storm or power surge and found the insurer could deny the claim.
The machinery exclusion for electrical or electronic malfunction or breakdown applied because the damage was not shown to result from a storm or power surge.
Issues
- Claim denial primary · not upheld“the information shows the loss was due to electronic failure or breakdown; this falls within a policy exclusion”
Subjects and remedies
no remedy
Related
Text of the determination
Determination
Case number 602642
Financial firm Insurance Australia Limited
Determination | Case number: 602642 Page 1 of 4
Case number: 602642 4 October 2019
1 Determination overview
1.1 Complaint
The financial firm (insurer) denied the complainant’s claim for damage to a machine
controller. The insurer relied upon a policy exclusion for machinery damage due to
electronic breakdown or failure.
The complainant disputes this as it says the damage was due to storm or a power
surge.
1.2 Issues and key findings
Can the insurer deny the claim?
The insurer can deny the claim because:
the information shows the loss was due to electronic failure or breakdown
the information does not show this was caused by a storm or power surge
this falls within a policy exclusion
1.3 Determination
This determination is in favour of the insurer.
The insurer can deny liability for the complainant’s claim.
Determination | Case number: 602642 Page 2 of 4
2 Reasons for determination
2.1 Can the insurer deny the claim?
Available expert evidence
Both parties have provided expert evidence.
The insurer provided a forensic report from E. E dismantled the controller and
reviewed all the components. E could not find any physical evidence of a power surge
or damage of that nature. Given this, E concluded the damage was not as a result of
lightning strike or other form of power surge. E said that based on its observations:
…strongly suggest failure of the PC motherboard has resulted from the aging and
deterioration of electrolytic capacitors mounted on the board.
This is relatively consistent with another report obtained by the insurer from O. O said
that after four hours of examination, there was no visual and instrumental
measurement signs of any catastrophic damage to components. O observed many
components having worn out.
The complainant provided two reports from O and A. O said the symptoms were not
indicative of syste m failure but of outside events. A ‘suspected a possible external
power surge over the weekend’ could have been the cause.
The complainant also provided a power report over the weekend during which the
failure occurred. This showed maximum demand between 8am and 12pm on 25
February 2017.
E’s evidence is persuasive
After carefully considering the available information, I am not persuaded the damage
is consistent with a storm or power surge.
O did not inspect the controller. It does not appear A inspected the relevant
components. It is plain both E and O did inspect the unit. E’s report was the most
thorough.
On balance, E’s evidence is most persuasive. The report is detailed. E provided
plausible reasons to exclude the damage being caused by the storm or power surge.
This included:
other modules not being damaged in a similar manner – they should have if power
surge was a cause
no other systems in the organisation suffering similar damage
no evidence of arcing in components
surge protective devices were found to be in a normal condition
Determination | Case number: 602642 Page 3 of 4
Given this, I accept the evidence does not show the controller failed due to a power
surge or storm.
Loss falls within a policy exclusion
The policy contains the following exclusion:
This Policy does not cover physical loss, destruction of, or damage to the
following property …
16. All Machinery (as defined in this exclusion) … occasioned by or happening
through any mechanical, electrical, electro-mechanical, electronic or hydraulic
malfunction, failure, derangement, breakdown or non-operation of whatsoever
kind.
‘Machinery’ is defined to include:
… any apparatus whether or not functioning independently or as any component
part of a collection of apparatus which generates, contains, controls, transmits,
receives, transforms or utilises any form or source of energy or power
It is clear the controller would fall within the definition of ‘machinery’. There is no
dispute that it has suffered damage due to electrical (or electronic) malfunction,
failure, derangement, breakdown or non-operation.
This engages the exclusion.
The policy does provide cover for ‘Fusion’. However, this requires there to be
evidence of destruction or damage caused by the actual burning out of parts by
electric current. There is no evidence of this.
Therefore, based on the available information, I am satisfied the above exclusion
applies.
Complainant’s arguments do not assist it
The complainant has raised the following arguments:
the insurer paid a previous similar claim
there is evidence of a third party source which has triggered the damage
there is evidence of a power spike
These do not assist the complainant for the following reasons.
The previous claim had clear evidence of electrical problems following the storm.
There is an absence of any of the electricals being affected by this storm.
Determination | Case number: 602642 Page 4 of 4
The complainant was given an opportunity to provide the report that says a third party
source triggered the damage. The complainant did not do so.
Whilst there may have been a power spike, there is no evidence to show this caused
the damage claimed for reasons set out above.
Therefore, after careful consideration of all the available information, I am satisfied the
insurer is entitled to deny the complainant’s claim.