Claim declined for gas log heater destroyed in explosion

FirmFinancial Firm (Unknown - Insurer)
Decided2019-02-08
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant claimed for a gas log heater destroyed when it exploded after a storm extinguished its pilot light. AFCA found the storm was not the dominant cause and the explosion exclusion for the exploded item applies.

The proximate cause was an intervening explosion, and the policy's explosion cover expressly excludes the item that exploded.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination | Case number: 549693 Page 1 of 4 Determination Case number: 549693 8 February 2019 1 Determination overview 1.1 Complaint The complainant holds a building and contents insurance policy with the financial firm (insurer) that covers his property. The complainant has lodged a claim with the insurer for the cost of replacing a gas log heater (heater) that was installed at the property. The complainant seeks cover under the “Storm” e vent listed in the policy. He says during a storm on 29 July 2018, the heater’s pilot light went out and that when he tried to re-ignite the pilot light, there was an explosion and the heater was destroyed. The only damage sustained in the explosion, and for which the complainant seeks cover for, the heater. The insurer has declined the claim saying:  the storm did not cause the damage  the cause of the damage was the heater exploding  it is likely the heater’s thermocouple or gas control did not shut off prop erly when the pilot-light was extinguished  the policy provides cover for damage caused by an “Explosion” however, the policy does not cover the item that exploded. 1.2 Issue and key findings Is the insurer entitled to decline the claim? The insurer is entitled to decline the claim because the cause of the damage was an explosion. The policy specifically excludes cover the item that has exploded which, in this instance, is the cost of replacing the heater. 1.3 Determination This determination is in favour of the insurer. The insurer is entitled to decline the claim and is not required to take any further action. Determination | Case number: 549693 Page 2 of 4 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim? Complainant has the onus to show an insured event has occurred The complainant bears the onus to show that the policy terms cover the loss, which in this instance are the cost of replacing the heater. This is known as a prima facie claim, or an insured event. Once the complainant establishes that an insured event has occurred, the onus t hen shifts to the insurer to demonstrate that the policy does not cover the loss because of a policy exclusion or on some other basis. Complainant says storm caused the damage The policy is a listed events policy, which means that cover will only apply whe n damage occurs because of a listed event. The complainant believes the damage to the heater was caused by a storm and this is the most appropriate event under which to seek cover. The complainant says the storm set-off a series of events and the damage would not have occurred had the pilot light not being extinguished by the storm. Proximate cause of the damage was an explosion When considering whether the policy responds, it is necessary to consider what the proximate cause of the damage is. In some instances, there may be more than one cause of the loss. However, the test is to consider what is the effective, dominant or operative cause of the loss is. I accept the complainant’s position that strong wind caused the heater’s pilot light to go out. However, I disagree that this was the cause of the loss. The storm caused the pilot light to go out – this did not damage the heater. Rather, the loss occurred when the heater exploded. There was an intervening event between the storm and the damage. In other words, there was a break in the chain of events between the storm and the heater being damaged. It cannot be said the storm was the effective, dominant or operative cause of the loss. This means the complainant’s entitlement to cover is not determined by the “Storm” event listed in the policy. Determination | Case number: 549693 Page 3 of 4 Policy provides cover for “explosion” but is subject to exclusions The most appropriate event which applies to the circumstances is “Explosion”. Page 18 of the policy’s product disclosure statement is relevant and states: What is covered What is not covered … Explosion We wi ll cover you for loss or damage caused by an explosion … We will not cover you for any loss or damage:  to the item that exploded, or  caused by any flammable substance kept at or brought onto your home or sit if this is in breach of statutory regulations. The insurer has provided several expert reports about what caused the heater to explode. The complainant has raised concerns about the conclusions in each of the reports and states that the conclusions were based on a lack of testing and a number of assumptions. It is not necessary to form a conclusive view about why the heater exploded. Based on the complainant’s own version, he confirms the “heater exploded”. The policy is clear in that when an explosion causes loss or damage, the policy will not cover t he item that has exploded. The complainant’s claim for loss is for the cost of replacing the heater only. As the policy expressly excludes cover for the item that exploded, I am satisfied the insurer has shown that it is not required to cover the complainant for the cost of replacing the heater. The insurer is therefore entitled to decline the claim. Determination | Case number: 549693 Page 4 of 4 3 Supporting information 3.1 The determination is made under FOS Terms of Reference The Australian Financial Complaints Authority ( AFCA) has commenced managing disputes previously lodged with F inancial O mbudsman S ervice (FOS) . This determination is made under FOS Terms of Reference but has adopted the following terminology for consistency with AFCA. In this determination the AFCA terms have the same meaning as the FOS terms defined in paragraph 20.1 and Schedule 1, 2 & 3 of the FOS Terms of Reference. FOS definitions AFCA term A pplicant complainant financial services provider financial firm D ispute complaint C laim claim

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.