Text of the determination
Determination | Case number: 540526 Page 1 of 12
Determination
Case number: 540526 29 March 2019
1 Determination overview
1.1 Complaint
The complainant lodged two claims with the insurer for water damage to two houses,
HO house and HA house. Both resulted from the one storm event. The complainant is
the insured for HA house and her husband (MA) is the insured for the HA house. MA
is an authorised representative of this dispute.
The insurer partially accepted both claims and issued a cash settlement.
The insurer declined the
HO house roof as it says it did not sustain any storm related damage but was due
to faulty design which is not covered under the policy
HA house floor, windows and doors as it says the cause of damage was not
related to the storm.
The complainant disputes the claim decisions and seeks full acceptance of both
claims. The complainant also raises concerns the insurer’s settlement is insufficient to
undertake the repair work. The complainant therefore seeks an increased settlement.
1.2 Issues and key findings
What is the extent of the insurer’s liability for HO house?
The insurer is not liable for the damage to the roof or the external wall as the
information does not show it was damaged by the storm. The insurer is liable for the
balance of the items being claimed.
The insurer is to settle the claim in line with R’s quote after excluding the roof and
wall. The insurer is also to reimburse the cost of the complainant’s expert (MAL)
report.
What i s the extent of the insurer’s liability for HA house?
The insurer is not liable for the staircase and cellar as the information does not show
it was damaged by the storm. The insurer is liable for the balance.
The insurer is to settle the claim in line wi th R’s quote after excluding the above items.
The insurer is also to reimburse the cost of MAL’s report.
Determination | Case number: 540526 Page 2 of 12
1.3 Determination
This determination is substantially in favour of the complainant.
For the HO house, the insurer is to pay:
$25,239.61 (minus any outstanding policy deductions)
interest pursuant to section 57 of the Insurance Contracts Act 1984 (the Act) on the
payable amount from the date the insurer first partially declined the claim until
payment is issued
the cost of MAL’s report
For the HA house, the insurer is to pay:
$57,233.99 (minus any outstanding policy deductions)
interest pursuant to section 57 of the Act on the payable amount from the date the
insurer first partially declined the claim until payment is issued
th e cost of MAL’s report
Determination | Case number: 540526 Page 3 of 12
2 Reasons for determination
2.1 What is the extent of the insurer’s liability for HO house?
Complainant must show the damages claimed were caused by the storm
The complainant is required to show, on the balance of probabilities, she has suffered
a loss caused by a risk insured against under the policy.
This is known as a prima facie (or valid) claim.
Once the complainant establishes a valid claim, the insurer is liable for the loss unless
it shows a condition or exclusion applies. The insurer has the onus of proof in
establishing this.
The complainant’s policy covers her for loss or damage caused by certain events
(insured events). Therefore, in order to establish a valid claim, the complainant must
show the damage being claimed was caused by an insured event.
The relevant insured event in this dispute is storm.
Parties dispute the extent of damage caused by the storm
These relevant facts are not in dispute:
there was a significant storm event on 29 December 2016
there was internal water damage to the kitchen ceiling, laminate benchtops and
vinyl floor coverings that is covered by the policy
The complainant has provided a number of quotes to support her claim. These are
$35,401.36 from R and $41,950 from P.
The insurer has disputed the complainant’s position. The insurer relies on A, who
inspected the property on 16 January 2017, and reported the claim related damages
total $4,577.57.
The insurer’s position is based on A’s report. A concluded the roof had issues
unrelated to the storm and the internal damage observed were limited to the kitchen
ceiling, laminate benchtops and vinyl floor coverings.
The complainant has provided a report from MAL in support of her position.
Part of the complainant’s position is substantiated
I have carefully reviewed the available information and note the following.
MAL’s report makes no finding that the roof sustained damage due to the storm. A’s
report identified issues, including large gaps in the apron flashings and the pitch of the
roof, that were not caused by the storm. Whilst MA provided an email disputing the
Determination | Case number: 540526 Page 4 of 12
reference that the roof was defective, he did not conclude that it sustained damage
from the storm.
R’s quote simply says the roof needs to be sealed. R does not say if it was c aused by
the storm.
Given this, I do not accept the complainant has established a valid claim for the roof
damage. The insurer is entitled to deny this aspect.
MAL did accept electrical fixtures were affected as well as the adjoining toilet and
basin. A’s report is silent on these aspects. Given the water entry came through the
ceiling, it is reasonable to accept electrical fixtures were affected.
A’s report does not discuss the adjoining toilet and basin area. MAL accepted these
were affected by the storm . Given MAL’s evidence is unchallenged, I accept the
complainant has a prima facie claim for this damage.
Neither expert discusses the external cladding with asbestos the complainant claims
was damaged by the storm. The quotation from P says this had external water
damage but does not expand on this in any way. R simply says the asbestos requires
removal but does not explain why.
It is unclear how the storm could have affected external cladding to this particular
area. No reasoning has been provided by any expert to address this. Given this, I am
not persuaded the storm caused this damage.
Insurer liable to pay $25,239.61 plus interest
Having reviewed the available quotations, I consider it is fair in all the circumstances
that the insurer’s cash settlement is based on R’s quote for the following reasons:
the insurer is proposing a cash settlement
it is the most economical of the complainant’s two quotes
A’s estimate does not appear to be based on market rates or a quote available to
the complainant
The latter is significant. There are substantive difference in the amounts allowed by A
and R. For instance, A allowed $660 to replace the ‘east side laminated bench top’.
This appears fairly low on the face of it. I note R provided $6,441 towards the cost of
new timber joinery units, including benchtops.
Having carefully reviewed R’s scope of works, I have excluded items 10 -12 as they
relate to the external cladding and the roof. Given this, R’s quote should be adjusted
to $25,239.61 to factor for this.
Therefore, the insurer is liable to pay this amount (minus any outstanding policy
deductions) as well as interest pursuant to section 57 of the Insurance Contract Act
Determination | Case number: 540526 Page 5 of 12
1984 (the Act) in full and final settlement of this claim. Interest is payable from the
date the insurer first partially declined the claim until payment is issued.
Insurer should also reimburse MAL’s report cost
We may require the insurer to contribute to the professional costs incurred by a
complainant. This normally occurs when the professional costs assisted the
complainant’s position. Normally, these costs are capped at $3,000 unless
exceptional circumstances apply.
I accept the insurer should reimburse the cost of MAL’s report given this assisted the
complainant and the issues in dispute required technical expertise. The amount
reimbursed should not exceed $3,000 as I do not accept exceptional circumstances
apply.
2.2 What is the extent of the insurer’s liability for HA house?
Parties dispute a number of items were caused by the storm
These relevant facts are not in dispute:
the significant storm event on 29 December 2016 also affected this property
there was water entry damage to the house
The complainant has provided a number of quotes to support their claim. These are
$63,051.34 from R and $67,480 from P.
The insurer has disputed the complainant’s position. The insurer relies on A, who
inspected the property on 16 January 2017 and reported the claim related damages
total $6,791.09.
The insurer has also provided two reports from SP. SP’s reports focused on the roof
and plumbing of the property. The complainant is not claimed for damage to these
areas.
The complainant has provided a report from MAL as well as an email. The
complainant has also relied upon the two quotes. However, R refers to water
damaged items as does P without any reasoning or detail in support. Therefore, they
provide minimal assistance to the issues in dispute.
I have rev iewed the complainant’s quotes, particularly R’s given it is detailed, and A’s
evidence and repair quote. I note the areas A does not appear to agree with are:
garage
timber floorboards
staircase and cellar
rear living room
Determination | Case number: 540526 Page 6 of 12
Having carefully reviewed A and MAL’s evidence, I note the following.
Garage
A’s report does identify water damage to the garage. A concluded this occurred over
a period of time as the ‘MDF’ trim has rotted. However, A does not dispute that water
entry to this area occurred during the storm being claimed and to what extent damage
was sustained by this.
MAL accepted there was extensive damage to the garage. This included to its ceiling,
cornice and walls together with evidence of mould.
Given this, I accept the evidence shows the garage s ustained damage from the
storm. I also note both A and R has provided an allowance for this work.
Floorboards
MAL accepted the timber floorboards were affected by the storm. This is because
there was cupping which is consistent with water entry rather than structural
movement.
A’s report concluded the floorboards were affected by structural movement alone as
he could not observe any water damage. However, MAL noted that structural
movement causes ‘defection and bowing in the bearers and floor joists’. MAL s ays
cupping, particularly in a localised area, is consistent with water entry.
A’s evidence does not address this.
I prefer MAL’s opinion. It is plausible and logical given it is fairly clear floorboard
cupping can result from water. Whilst A refers to an absence of water stains, it is not
clear if this would always be evident. MAL’s report would indicate otherwise. Further, I
note A did not inspect the property until two and a half weeks after the event. It is
possible the area was dried out by the time he inspected with no stains present.
Therefore, I accept the insurer is liable for the floorboards.
Staircase and cellar
Neither A nor MAL comment on the staircase.
R’s quote refers to replacing a decorative cornice and removing mould affected
plaster in this area. It provides no further detail or comment.
MAL does not comment on the cellar. A says it noticed no structural damage. R’s
quote refers to sealing brickwork but does not comment how it was affected by the
storm.
The complainant says water entry is evident through all photos. However, there are
no clear photographs showing the damage to these areas.
Determination | Case number: 540526 Page 7 of 12
Given the minimal information, I am not persuaded the complainant has established a
valid claim for the staircase or cellar.
Rear living room
A’s report appears to refer to this as the ‘kitchen/family’ room.
R’s scope of works to this area is fairly substantive. It effectively comprises half the
amount sought. Included in this is an allowance of $19,091 for supplying and installing
‘new timber window, door frame combination including doors and all hardware’. This
includes security doors.
The windows and door encompass a large part of this area. It also appears to work as
a barrier to an in-ground pool adjacent to this on the outside.
A’s report noted the double doors have dropped and are binding. A believes this is
associated with structural movement. However, A’s photographs do show that there is
‘splitting to the rear doors’. The photographs in MAL’s report appears to show this as
well. Such splitting appears more consistent with water damage rather than binding.
MAL’s report notes that the French doors in this area is adjacent to an in -ground pool
and are no longer operational due to the damage sustained. MAL was satisfied it was
affected by the water entry. This is consistent with the fact the floorboards nearby
were also affected.
On balance, I prefer the complainant’s position. It is consistent with the photographs,
her evidence that there was water entry to this area and the cupping floorboards.
Therefore, I prefer R’s scope of works about the extent of repairs necessary to this
area of the home.
Insurer should pay $57,233.99 plus interest
Similar to the claim for the HO home, I consider it is fair in all the circumstances to
rely on R’s sco pe of works.
Considering the above conclusions, I have excluded the items for the staircase and
cellar. I have also reduced the supervision by 3 hours to reflect the fact that the
amount charged for the staircase and cellar comprised about 10% of R’s cost.
Given this, R’s quote should be adjusted to $57,233.99.
Therefore, the insurer is liable to pay this amount (minus any outstanding policy
deductions) as well as interest pursuant to section 57 of the Act in full and final
settlement of this claim. Interest is payable from the date the insurer first partially
declined the claim until payment is issued.
Determination | Case number: 540526 Page 8 of 12
Insurer should also reimburse MAL’s report cost
The insurer should also reimburse the cost of MAL’s report given this assisted the
complainant and the issues in dispute required technical expertise. The amount
reimbursed should not exceed $3,000 as I do not accept exceptional circumstances
apply.
Determination | Case number: 540526 Page 9 of 12
3 Supporting information
3.1 The determination is made under FOS Terms of Reference
The Australian Financial Complaints Authority ( AFCA) has commenced managing
disputes previously lodged with F inancial O mbudsman S ervice (FOS) .
This determination is made under FOS Terms of Reference but has adopted the
following terminology for consistency with AFCA. In this determination the AFCA
terms have the same meaning as the FOS terms defined in paragraph 20.1 and
Schedule 1, 2 & 3 of the FOS Terms of Reference.
FOS definitions AFCA term
applicant complainant
financial services provider financial firm
dispute complaint
3.2 Experts opinions
Record Key points
HO house
Insurer’s builder (A)
Report
17 - 01 - 2017
Observed water damage to kitchen Masonite sheet ceiling,
laminated bench tops and vinyl floor covering.
Rainwat er entered through the corrugated iron roof above due to
a number of issues. Inspected the roof area above the kitchen
and found large gaps to the apron flashing on the east side of the
roof. There is also a downpipe deposit pipe in this area which has
inundated the flashing allowing water to e nter the gaps. Tested
the roof pitch and found it did not comply with plumbing
regulations for a corrugated iron roof. Roof pitch above kitchen is
3.1 degrees. The minimal fall pitch for corrugated iron roofing is 5
degrees to prevent rain water ingress t hrough the sheet lap joints
during heavy rain.
Complainant’s builder (M)
Report
12 - 10 - 2018
Upon inspection of various areas, clearly the noted elements
were affected by water ingress to various areas. Rainwat er goods
were inspected and found to be in good order, clear and free of
debris and would not have been of a design to cater for the one -
off intens e exceptional storm event and allowed in a number of
areas of water ingress.
Hous e rear area comprised of kitchen area, adjoining toilet and
basin area. Ins pection observed extensive water damage to
various elements of these rooms namely vinyl covered flooring,
kitchen laminate bench top and associated timber cabinet, ceiling
Determination | Case number: 540526 Page 10 of 12
Record Key points
lining and associated wall lining, window frame and associated
installed electrical fixtures comprising of exhaust fans, light and
electric stove which have all been electrically isolated.
Elements noted were in both working order, materially sound,
good order and acceptable in finish prior to storm event. Evident
storm did cause elements to become structurally unsound and
not meet minimum requirements of both [state] building authority
and tolerances and Australian standards.
HA street
Insurer’s roof plumber (S)
Report
24 - 01 - 2017
Internal gutter sump blocked with a tennis ball but the
c omplainant explained he cleaned out all the gutter after previous
storm and believes this just happened.
No over flow for this gutter so if the sump was blocked like it is
now, water would easily fill up in the gutter and overflow into the
roof space. The wat er would then leak into family room ceiling
and possibly make its way to damaged hallway.
No issues with roof sheets, flashing and capping. Believe gutter
overflowing is the result of damage to this area.
Then ins pected roof above garage. Gutter drains into rain head
does not have an overflow hole to prevent the water building up in
the rain head. Water built up in the rain head due to extreme
large storm. Water would have run into the garage through the
gap between the bottom of the box gutter shut e and wall.
Conc ern the garage was with the downpipe spreader. Found end
of spreader faced a join in the roof sheets. In large storms,
possibility of wat er forced through the join from the spreader.
No issues with the roof above the back section of the house.
Found no eve along the back of house and found if the gutter was
to overflow it would overflow into the damaged external wall. This
has most likely happened during a large storm.
Damage to family room and hallway most likely due to internal
gutter above ov erflowing. Found gutter does not have an overflow
and debris would easily fill up in the sump blocking the outlet.
Due to this and extreme large storm, believe wat er built up and
overflowed from this gutter.
Damage to garage would have been caused by water running
back into the garage through gap bet ween box gutter shute and
the wall. Found no overflow hole in the rain head to prevent this
from happening.
Damage to back - left corner most likely result of gutter above this
wall overflowing. Found if gutter wa s to overflow the water would
run into the damaged wall. This gutter most likely overflowed
during the large storm.
Insurer’s roof plumber (S)
Report
13 - 02 - 2017
Tested all storm water, sewer and water pipes to see if a leaking
pipe could be the cause of damage.
Inspected storm water pipe through pit located along front of
house gutter. Pushed camera through two separate drains that
Determination | Case number: 540526 Page 11 of 12
Record Key points
ran along left and right side of house. Only issue I found was
under the footpath at front of house. Found pipe dislodged.
In spected stormwater along left side of house, found downpipe at
front left corner not connected correctly. Due to this water will
leak from connection and run alongside of house. Pushed camera
down downpipe on left side of house. Found drain to be in very
g ood condition with no areas of concern.
Inspected rest of storm wat er which runs down the right side of
house. Found drain in very good condition, no areas of concerns.
Inspected sewer. Found no issues with sewer line and believe
they are not the cause of the damage found.
Tested hot and cold water lines. Tested the waterlines to 400Kpa
and found no loss of pressure over 15 minutes. Proves no water
leaks on any hot or cold water pipe.
Hous e damage has not been caused by a leaking pipe. Found all
the stormwa ter, sewer and waterlines to be in good condition and
watertight. Only concern is some damage caused by downpipe at
front left corner of house which is not connected correctly. Due to
this, water leak from downpipe and pool along the side of house.
Insurer’s builder (A)
Report
14 - 02 - 2017
Rain water to garage has occurred over time as the MDF trim
rotted indicating several events exposed to rain water over time.
Damage to living room and garage due to rain water entry to roof
cavity. Roof plumber repo rt ed found there to be internal box
gutter wit h no overflow in the rain head/sump. During heavy
rainfall these gutters will overflow.
Unable to see any water damage evidence to kitchen/family
room. Flooring has no water stains but is cupped. Believe floor
has cupped due to structural movement and binding on the door
jamb which also appears to be consistent with structural
movement. More severe movement to east wall which has been
patched before.
Front north - east corner shows signs of dropping due to footing
failure. Signs of foundation movement to front bedroom and
hallway, rear south wall elevation of house.
Disturbance in hallway skirting board appears consistent with
structural as there is no wat er marks.
Unable to see any water staining to front bedroom , hallway and
family room, therefore believe damage is consistent with
structural movement. Brief assessment of external yard shows no
visible evidence of site drain. CCTV inspection by licensed
plumbing contractor found no leaking storm or sewer pipe to a rea
of house therefore maintain sinking floor area is structural
movement issue. There is a down pipe which has become
disconnected at the front left - hand cover of house. Visible to
complainant and would have been aware of issue for some time.
There is a l eaking storm water pipe found under front footpath out
of the complainant’s property perimeter.
Complainant’s builder (M) Rainwat er goods inspected and found to be in good order clear
Determination | Case number: 540526 Page 12 of 12
Record Key points
Report
12 - 10 - 2018
and free of debris. Would have not been of a design t o cater for
the one off intense exceptional storm event and allowed water
ingress in many areas.
Garage area, extensive damage to ceiling, cornice, water staining
to walls together wit h evidence of mould underpins confirmation
of damage because of water in gress.
Hous e rear area, extensive damage to timber flooring via cupping
of strip timber floor for the area of the full width adjoining the
perimeter Frenc h style timber doors. Such damage from
experience is clearly the result of excessive moisture, such
da mage is reflected in adjoining doors to the lower section
throughout as well as adjoining skirting boards. Damage to ceiling
adjacent wall sections in adjoining areas is also evident with
cracking and bulging of plaster associated with ingress of water
and or moisture. Further evident to ceiling in basement.
Current French doors located adjac ent to inground pool area not
effectively operational in terms of pool barrier due to damage
sustained.
Elements noted were in both working order, both materially
sound, good order and acceptable finish prior to storm event.
Evident storm did cause such elements to become structurally
unsound and did not meet minimum requirements of [state]
building authority standards and tolerances and Australian
standards.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.