Home / Financial Firm (Unknown - Insurer) / Determination 539673

Determination 539673

Claim declined for cracking and movement damage from escape of liquid

FirmFinancial Firm (Unknown - Insurer)
Decided2019-01-11
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded$82,143
Non-financial loss—
Amount claimed$164,285
SourceAFCA PDF

Summary

The complainant's home building claim for cracking damage was declined. AFCA found the leaking stormwater pipe and an inadequate 2011 underpinning contributed equally, so the insurer must pay 50% of the repair quotes with statutory interest plus soil testing costs.

The proximate cause is the dominant or operative cause, and the damage was apportioned 50-50 between covered leaks and the excluded or non-covered underpinning.

Issues

Subjects and remedies

home or building damagepay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination | Case number: 539673 Page 1 of 13 Determination Case number: 539673 13 December 2018 1 Determination overview 1.1 Complaint The complainant lodged a home building claim in regard to cracking and movement damage. The financial firm (insurer) declined the claim based on its view the complainant did not establish a valid escape of liquid claim, but rather inadequate underpinnings and not leaks caused the damage. The insurer also says a policy exclusion for ground movement defeats the claim. 1.2 Issues and key findings What is the extent of the insurer’s obligations to the complainant under the terms of the policy? The panel is satisfied that the complainant has established a valid claim under the policy. However, the panel is also satisfied that the insurer has established that part of the damage was caused by circumstances not covered by or excluded from coverage under the policy. The insurer is to meet 50% of the complainant’s claim for da mage. 1.3 Determination This determination is partially in favour of the complainant. The insurer is required to accept part of the claim in line with its policy terms and conditions. As set out in section 2.1, the insurer is required to pay the complainant:  50% of the repair quotes, with statutory interest, within seven days of the complainant accepting this determination  costs of soil testing, within seven days of the complainant providing an invoice to the insurer. Determination | Case number: 539673 Page 2 of 13 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim? The complainant bears the onus to establish a valid initial claim General insurance policies provide cover with conditions and exclusions. The policy wording and certificate of insurance outline the cover provided by the insurer and any applicable exclusions. When lodging a claim with an insurer, the insured must establish a valid claim. That is, on the balance of probabilities, an event covered by the policy must have caused the loss. Once a valid claim is established, the insurer must show, on the balance of probabilities, it is entitled to rely on a policy exclusion or otherwise is not required to cover the loss. The parties dispute the policy responds to the damage In this complaint, the complainant holds home building cover for damage caused by insured events, including the escape of liquid. The complainant lodged an escape of liquid claim for structural and wall cracking damage. The insurer declined the claim based on its views:  the complainant did not establish a valid claim, because inadequate underpinning works (not a leak) caused the damage  even if an insured event was established an exclusion (earth movement) would defeat the claim. The complainant disagrees with the decision and argues a broken and leaking stormwater pipe and drain caused the damage. She wants the insurer to pay the claim based on repair quotes for $10,285 (tiling) and $154,000 (slab, masonry, walls and windows). As the parties dispute the cause of damage, the proximate cause must be considered. The proximate cause is the dominant or operative cause Damage can have more than one cause. When deciding whether the policy covers the damage, the proximate cause of the damage must be identified. This is a question of fact depending on the circumstances in each complaint. The proximate cause is not necessarily the first or last or the sole cause of the loss. It is the effective, dominant or operative cause of the loss. If there are several causes operating at the same time, AFCA considers each one to determine which cause set the train of events in motion. Determination | Case number: 539673 Page 3 of 13 Courts have said that if one cause would have resulted in the harm in any case and the other would not have done so in the absence of the first, then the first is the proximate cause. The property experienced leaks under the ground The panel has closely reviewed the parties’ materials, which confirm: Date Action 2011 Underpinning works (south, west, east sides) occurred after the complainant’s building experienced cracking/movement damage. 18 - 05 - 2016 The complainant contacted the engineer who designed the underpinning works (DP), aft er she noticed building cracking. 04 - 06 - 2016 DP inspected the underpins and said he found the material underneath very wet and soft. He estimated a leak had co mmenced aft er 2012 and had been occurring over a period of years. He suggested the complainant lodge an insurance claim for a leak. 25 - 11 - 2016 The complainant lodged a claim with the insurer. 21 - 12 - 2016 The insurer’s builder (OP) provided a report confi rming several stormwater drain/pipe leaks (west side), including a large void/sinkhole (south west side) caused by water discharging into soil instead of pipe connection. 25 - 01 - 2017 The insurer’s engineer (HC) inspected the property and recommended further investigation into the effect of the leaks, and into the underpinnings. 10 - 04 - 2017 The insurer’s engineer (HC) again provided a report based on his second inspection of the property and plumbing test results. He concluded the underpinnings were of inadequate depth and the leak(s) did not cause damage. 18 - 04 - 2017 The insurer declined the claim. 14 - 07 - 2017 The complainant completed the boundary trap repairs. 06 - 02 - 2018 The complainant arranged for soil testing. The relevant reports, tests and photographs, which are contained in section 3.3, support leaking occurred from the stormwater drain/pipe into the ground under the property. The insurer agrees leaks occurred but states the complainant did not establish a valid claim because HC confirmed inadequate underpinnings, not the leaks, caused the damage. Determination | Case number: 539673 Page 4 of 13 The proximate cause of the damage HC concluded that the leak(s) into the void/sinkhole had little impact upon the ground’s moisture content, because it was near the footpath and a council boundary trap. The panel notes from the photographs and the property survey that the footpath and therefore the void/sinkhole, appear to be relatively close to the building. DP advised that at the time of the 2011 underpinning works, the base material was found to be firm and hard, but since then the base material has become soft and wet. The complainant’s soil testing details the findings in relation to the moisture content at the complainant’s property. Having reviewed all of the exchanged material, the panel is satisfied that the complainant has established that the property has been impacted by the leaks and this has contributed to the damage at the property. However, the panel notes that underpinning works were carried out at the property in 2011, as a result of the complainant having noted cracking prior to the underpinning. The panel is satisfied that the earlier cracking at the property and the need for the 2011 underpinning establishes that the property was already sinking prior to 2011. The panel also notes that there is no evidence to establish the length of time that the ground in the area has been saturated as a result of the leaks. HC has detailed that in his view, the underpinning is not deep enough and is also not consistent around the home. The panel is satisfied that HC has provided a thorough and logical explanation of the type of underpinning which would have been required to prevent further sinking and that the underpinning which was provided, is insufficient. The result is that the panel is satisfied that the insurer has established that the underpinning carried out in 2011 has contributed to the circumstances of the complainant’s loss. That is, the 2011 underpinning is also a proximate cause of the current damage. Whilst it is not possible to detail the precise contribution of the leaks and the underpinning to the damage, the panel is of the view that it is fair that the cause of the damage be apportioned 50-50 between the leaks and the underpinning. Accordingly, the insurer is required to accept 5 0% of the complainant’s claim in line with the terms and conditions of the policy. Determination | Case number: 539673 Page 5 of 13 The insurer is required to pay the complainant 50% of the repair quotes, within seven days from the date the complainant accepts this determination. Statutory interest applies in line with section 57 of the Insurance Contracts Act 1984 (the Act), from the date of the quotes until the date the payment occurs. The insurer is also required to reimburse the complainant the costs of the soil testing, within seven days of the complainant providing the invoice/receipt to the insurer. Determination | Case number: 539673 Page 6 of 13 3 Supporting information 3.1 The determination is made under FOS Terms of Reference The Australian Financial Complaints Authority ( AFCA) has commenced managing disputes previously lodged with F inancial O mbudsman S ervice (FOS) . This determination is made under FOS Terms of Reference but has adopted the following terminology for consistency with AFCA. In this determination the AFCA terms have the same meaning as the FOS terms defined in paragraph 20.1 and Schedule 1, 2 & 3 of the FOS Terms of Reference. FOS definitions AFCA term applicant complainant financial services provider financial firm dispute complaint claim claim This determination has been made by a panel consisting of the panel chair ombudsman, a representative with extensive experience in the insurance industry and a representative with extensive experience in consumer claims. 3.2 Policy What you are covered for - Insured Events We cover the building for loss or damage at the insured address caused by an insured event during the period of insurance. There are some things we do not cover and these are shown in the ‘We do not cover’ section of the following tables on pages 16 to 25 and in the ‘What we do not cover - general exclusions’ o n pages 35 to 40. Escape of liquid We cover – Loss or damage to the building caused by liquid leaking, overflowing or bursting from any of the following: any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems; We do not cover – wear and tear, or loss or damage by the escape of liquid occurring as a result of a gradual process of leaking, splashing, dripping or overflowing over a period of time when you could reasonably be expected to be aware of this conditio n … Determination | Case number: 539673 Page 7 of 13 What we do not cover - general exclusions You are not covered under any section of your policy for damage, loss, cost or legal liability that is caused by, arises from or involves: Ground movement – erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement … 3.3 Reports Record Key points Insurer’s expert (OP) Leak report Licensed commercial builder Licensed domestic builder 21 - 12 - 2016  We attended the site to pressure test all water lines and report on the cause of damage to the property.  The Insured has advised that underpinning of the foundation was undertaken recently.  We noted cracking of the external and internal brick walls of the property.  Cold water line pressure test; Hot water line pressure tes t; CCTV inspection of the sewer system: tested; Passed:  Was the cause of the leak found? Yes … CCTV inspection of the storm water system: tested; Failed  Description of the cause of the leak:  All pressure testing to water supply pipework has passed.  [We] … reattend[ed] and conduct[ed] CCTV inspection of the storm and sewer systems to determine if these pipes may be causing any resultant damage. We inspected the sewer drains from the kitchen sink and toilet and there were no breaks or cracks.  While visually i nspecting the storm water system we discovered there are cracks and holes in the top of the PVC surface drainage system for approximately 10m from the second down pipe towards the street.  Excess water is able to exit the pipe at these surface areas.  There is subsidence and a pothole in the asphalt footpath at the front of the property.  CCTV inspection of the storm water drain has indicated cracks and holes at the surface as mentioned above; however the bottom of the storm water pipe does not appear to be d amaged.  The pipe was flowing freely to a point where a failure of the joint between the PVC and a small section of vitrified clay pipe under the asphalt was identified.  Water discharges the pipe at this t - piece joint failure which may cause water ingress and deterioration to the integrity of the surrounding asphalt area.  The asphalt footpath will need to be excavated and the damaged/faulty sections of storm water pipework will need to be replaced.  There is a surface grate underneath an external cold water tap Determination | Case number: 539673 Page 8 of 13 Record Key points which has been cut over the waste pipe from the kitchen sink. This is an illegal connection. Insurer’s expert (HC) Licensed, chartered professional engineer Report 28 - 01 - 2016  Cracking and movement became evident in the house around 2010 and underpinning was carried out of the west, south and east walls around 2011.  It was indicat ed that 7 underpins were constructed along the west side, 4 underpins along the sout h side with only 3 underpins along the east side.  Following the underpinning work renovations and redecorating were carried out to the interior of the house to repair the cracking.  Following the underpinning, cracking continued to occur along the west wall over the years and this cracking has been getting wors e. The owner contacted the original engineer and underpinning cont ractor to inspect the new cracking and movement and a test hole was excavated midway along the west side by the underpinning contractor. It was indicated that excessive dampness was evident in the ground when the bore hole was excavated.  Prior to Christmas a plumbing check was carried out of the property and several problems were found with the stormwater drains along the west side. During this time a small hole developed in the footpath area and recently the Council d ug up the footpath in this area and found a large void underneath the footpath. It was also found that the stormwater pipe where it met the Council pipe underneath the footpath area had dislodged and water was escaping from this area.  Our office carried ou t a site inspection of the above property on 25 January 2017 … Evidence of the previous underpinning was observed as cut outs have been provided in the original concrete paving. A stormwater pipe extended along the west side of the property to the front.  An inspection of the external west wall showed that considerable amount of cracking and movement was evident of the brickwork particularly around the middle bedroom and lounge room areas. This cracking showed weat hered edges which would indicated that the cracking has been occurring for a very long period of time.  An inspection of the front brickwork to the south wall showed that cracking and movement was evident particularly around the windows to the front two bedrooms.  An inspection of the interior of the house showed that considerable amount of cracking and movement was evidenc e particularly to the middle bedroom and lounge room along the west side. Generally excessive movement was occurring in the west wall in thes e areas.  An inspection of the dining roo m which is located on the east side showed that cracking and movement was also evident particularly where the lounge room meets the dining room area. Determination | Case number: 539673 Page 9 of 13 Record Key points  An inspection of passageway and two bedrooms along the east side showed that minor cracking was evident to these areas.  An inspection of the kitchen area showed that cracking was evident of the walls particularly at the south end.  An inspection of the back porch showed that cracking and movement was evident with gaps at the plaster ceiling to the brick wall on the south side. The double doors to the backyard were out of alignment.  An inspection of the bathroom area showed that mino r cracking was evident around the south - west corner.  The cracking and movement of the house is typical of problems that occur due to differential settlement of the footings. Differential settlement can occur of the footings due to seasonal changes in the m oisture content of the foundation material.  It would also appear that voids are occurring underneath the footpath area and maybe extending into the property. The full extent of thes e voids is not known.  Normally underpinning extends down to a dept h below the existing footings and in our opinion the depth of the underpins should be deeper than any of the service pipes including stormwat er and sewer pipes to the property.  Therefore, even although voids are occurring particularly to the front section of the p ath along the west side, it would appear that the voids do not extend down below the level of the underpins.  Therefore, in our opinion, even although voids are occurring around the front sout h - west corner of the house, in our opinion the underpinning works carried out should be at a depth greater than these voids.  We would recommend that further investigation work would need to be carried out to determine the extent of the voids extending into the property and whether the underpinning has been carried out i n accordance with the original design.  Soil testing may also need to be carried out to confirm the depths of the underpin as well as to confirm in the original underpins were carried down far enough originally. HC Licensed, chartered profe ssional engineer Report 10 - 04 - 2017  a second site inspection was carried out of the above property as well as a plumbing check to determine the reason for cracking and movement to be occurring to the brickwork to the house  cracking and movement evident particularly the western side of the house is typical of problems that occur due to inadequate underpinning of the wall  The recent plumbing check has found that problems are occurring with both the sewer and stormwater pipes along the west of the house. The stormwater pipe is a PVC pipe and has been constructed close to the surface. Due to the pipe being close to the surface several holes are occurring in the top of the pipe. No blockages were found in the pipe except for a section of pipe has Determination | Case number: 539673 Page 10 of 13 Record Key points been squashed near the footpat h area. This section of pipe was still allowing water to flow through, however the camera could not extend through this section of the pipe. Therefore, the stormwater pipe is not blocked and only has a restriction near the foot path area due to the squashed section of pipe.  photographs they show the pipe was broken and water was discharging directly into the void near the footpath area. Therefore even although the stormwater pipe was broken the water was discharging into the void near the boundary trap and w ould not have been resulting in water extending particularly up to the lounge room area.  A major problem is occurring with the sewer pipes to the property with the sewer pipes not being connected to the boundary trap near the front of the house … connectio n to the boundary trap had failed. It would appear that the sewer is flowing directly into the void around the boundary trap and not into the sewer pipe.  The [council] sewer is located out in the street and a boundary trap is provided to connect the house sewer pipes to the [council] sewer. The sewer pipes to the house are relatively shallow, however the sewer out in the street is a deep sewer. Therefore, a vertical drop occurs at the boundary trap bet ween the house sewer pipes and the [council] sewer out i n the street. The construction of the boundary trap requires a deep shaft to be excavated and a vertical section of pipe layed. The area is then backfilled. Depending on the degree of compaction of the backfill lower term settlement can occur around the bo undary trap. Movement can also occur in the vertical section of pipe which can also result in breaks occurring in the pipe. Therefore it is possible that material can be washed into the boundary trap vertical section of pipe and into the sewer creating a v oid around the outside of the boundary trap.  It would appear in this case that a problem is occurring with the vertical section of boundary trap which is resulting in both the sewer and stormwater discharging into the void … recently the stormwat er pipe co nnection was refitted to the foot path area and the stormwater is not discharging into the void now. From our recent plumbing check the void is only occurring around the boundary trap area whic h is in the front of the property near the footpath area. This v oid does not extent back up to the rear lounge room area.  Therefore, in our opinion, the cracking and movement in the house has resulted due to inadequate underpinning of the house around 2011 and even or though problems are occurring with both the sewer sand stormwater pipes these problems would not be contributing to the movement.  Considerable movement is occurring in the west wall and in particularly the area around the lounge room area.  It is possible that soil testing could be carried out to determine the depth of the underpinning as well as the type of existing trip Determination | Case number: 539673 Page 11 of 13 Record Key points footing … Therefore, the full extent of the voids around the boundary trap and where the water is going to cannot be determined until the area is opened up … The recent video check of the pipe could not extend into the boundary trap and the top of the boundary trap is blocked with debris.  … underpinning drawings specify the depth of the underpins to be 1m below the existing footing level … this depth is inadequate as normal underpinning now specifies the depth to be at least 1.8m to 2m deep … the underpinning design was carried out by the design engineer and is not based on any soil testing. If soil testing had been carried out then the moisture content of the foundation material would have been specified as well as the depth of the underpinning. The exact type of existing strip footing underneath the brick walls is not specified on the design documents, however due to the age of the house it would appear that the footings to the house would be either a bluestone footing or rubble footing. In our opinion continuous underpinning is required of this type of footing and not hit and miss underpinning as specified on the drawings. Very little information is available regarding the underpinning and it is not clear if any further problems were found with any service pipes including the stormwater and sewer pipes extending along the west side of the house. HC Further comment 05 - 09 - 2017  Major breakage occurred in the pipes near the connection of the property sewer to the [council] Sewer  The sewer from this property was flowing out of the property sewer and around and into the [council] connection.  The plumbing reports indicated that the pipes to this property were repaired as well as the pipes to the [council] sewer. Therefore problems occurred with both pipes and the excess sewerage would have been flowing into the [council] Sewer through the [council] breaks. [CM note – doesn’t follow – as void at boundary trap is ON app’s property and adjacent to we stern wall] All of the plumbing checks showed no blockages or problems with the sewer pipes within this property until around the connection to the [council] sewer.  The only void found was at the connection of the property sewer to the [council] sewer and not further into the property.  Even although the pipes were broken the broken pipes have not resulted in water extending along the west wall to the lounge room area or any voids further along the west wall. Complainant’s expert (DM) Plumber Email to the Complainant 13 - 11 - 2017  As discussed on the phone, please see the below information about the job we complete on behalf of [the water supplier].  29/8/17 – Completed a CCTV inspection of the House Connection Branch.  14/11/ 17 Attended site but had to re book for the 6/ 10.  6/10/17 – Completed a reline of the House Connection Branch. Job complete. Determination | Case number: 539673 Page 12 of 13 Record Key points  The repair works that we complete are only on [the water supplier’s] sewer drains. We have completed a reline of the Hous e Connection Branch. Complainant’s expert (DP) … engineer Email to the complainant reporting on works and reattendance 17 - 05 - 2018  I do have the following factual information for you to consider.  The underpin works on your property were carried out in 2011 - 2012.  The works were carried out with t he required Building Permit and all the required inspections took place.  As part of this process an independent inspector inspected the works and found the base material to be firm and hard.  As a result approval was given to your contractor to pour the c oncrete. This is a standard requirement.  If the base material was found to be soft then approval to pour the concrete would not have been provided to the contractor by the independent inspector.  In June 2016 investigation works were carried out and a hole was excavated to the bas e of one the underpins.  During these works your contractor, you, your husband and I were present.  The material that was encountered at the base of the underpin was very wet and soft.  This confirmed that over the period of 4 - 5 years the base material went from being firm and hard to being soft and wet.  You saw the soft material that was excavated and the advice was provided to you in relation to the defective stormwater system.  Your stormwater system is located on the surface.  This escape of water over a period of several years affected the performance of the footings.  The base material had gone from firm and hard to wet and soft. This process was taking place from 2012 to June 2016 which is several years in the making. Movement of the footings is to be expected given that there was considerable abnormal moisture contents changes taking place through these years. 3.4 Other records Record Key points The complainant Email to the insurer 27 - 04 - 2017  Thank you so much for taking the time to call me and giving me the chanc e to advise you that HC had advised myself and (my husband), on two separate occasions, that he will be organising for the side of the house to be dug up / opened up and have [the water supplier] on standby when this was to take place  So he could actual see for hims elf, just how deep and how Determination | Case number: 539673 Page 13 of 13 Record Key points far into the property the sink hole is / goes. HC explained that he believes the sewage loss is going directly into this sink h ole. DP … engineer Email to the complainant 21 - 05 - 2018  … As previously advised I am not responsible for your property and I do not accept any responsibility due to the defective stormwater system that affected the work performed and the movement of your p roperty.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.