Home / Financial Firm (Unknown - Insurer) / Determination 538099

Determination 538099

Water damage claim to rental property partly declined under wear and tear and defect exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2019-04-17
ProductGeneral Insurance · Landlord
OutcomeFor the complainant in part
Amount awarded$29,887
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The landlord claimed under the policy for water damage from a leaking shower recess, hot water system and fixed pipes, and the insurer denied it as wear, tear, corrosion and defects. AFCA found the fixed pipe leaks were covered, apportioned the cost 50/50 with a 15% contingency, ordered $29,887.11 plus interest, and allowed 45 days of loss of rent.

Where covered and excluded causes operate concurrently and cannot be separated in time, it is fair to split the repair cost evenly between the parties.

Issues

Subjects and remedies

pay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination | Case number: 538099 Page 1 of 9 Determination Case number: 538099 9 April 2019 1 Determination overview 1.1 Complaint The complainant lodged a claim on 4 May 2018 under his landlord policy with the financial firm (insurer) following water damage sustained to his property. The insurer assessed the water damage and subsequently denied the claim. In doing so, its experts say the water damage is due to wear, tear, a structural defect and faulty design. The case analyst provided the parties with a preliminary view on the issues in dispute. The preliminary view was in favour of the insurer. The complainant provided further expert reports following the preliminary view and seeks indemnity under the policy. 1.2 Issues and key findings Is the insurer liable to meet the claim? I am satisfied that the complainant has established a valid within the terms of the policy for part of the damage as:  the identified sources of damage include at least two sources of damage to which the policy responds.  the available information does not establish the timeframes during which the various leaks occurred. I accept that not all the damage is due to an insured event. In the circumstances it is fair that the insurer meets 50% of the claim for damage and loss of rent as set out under section 2.1 of this determination. 1.3 Determination This determination is partially in favour of the complainant. The insurer is required to pay the complainant $29,887.11 as set out under section 2.1 of this determination plus interest in accordance with section 57 of the Insurance Contracts Act 1984 (the Act) from 23 May 2018 to date of payment of the claim. Determination | Case number: 538099 Page 2 of 9 The insurer is also required to pay the complainant loss of rent for 45 days being 50% of the estimated time to repair the premises subject to the complainant establishing loss of rent occurred during the repair period. Determination | Case number: 538099 Page 3 of 9 2 Reasons for determination There has been a full exchange of material between the parties and each party has had the opportunity of addressing the issues that arise from the information exchanged. This determination follows consideration of all the information provided both before and after the preliminary view and is based on what is fair in all the circumstances having regard to the relevant legal principles, terms of the policy, good industry practice including codes of practice and prior determinations where applicable. 2.1 Is the insurer liable to meet the claim? The complainant has onus to establish a claim within the terms of the policy The complainant’s policy is a defined events policy that provides cover for several defined events including water escaping from a fixed pipe, shower base or wall and a water tank. The complainant’s bathroom and surroundings areas sustained water damage due to a leaking shower recess and water leaking from two pipes and a hot water system (HWS). This is not disputed As the loss or damage arose from the escape of water from the shower base, fixed pipes and the HWS I am satisfied the complainant has established a claim within the terms of the policy. The insurer has the onus to establish an exclusion applies The insurer says the damage was caused by gradual deterioration, depreciation, wear and tear or the defect in an item. Alternatively, it says the damage was caused by faulty workmanship. The insurer’s building consultant ‘BS’ says the HWS is leaking from the cylinder which has corroded due to age and the shower screen was leaking although he considered this to be minor in nature. The assessor says the hot water tank has corroded due to its age and has been leaking for a period of six months. The insurer’s plumber MPA concluded the shower recess is leaking through its cracked tiles and deteriorated grouting. MPA says large amount of water was coming through the shower screen door and the HWS leaking below the cold-water inlet. Further the HWS hot water service had no drip tray and considered that it had been incorrectly installed. The insurer says the hot water system was not compliant with the applicable building code at the time of its construction. Determination | Case number: 538099 Page 4 of 9 The insurer attributed the damage to the absence of the drip tray below the hot water tank. Further, the insurer considers such omission as a structural defect. BS says a drip tray is in fact required. Hot Water Service drip tray not mandatory The complainant says the drip tray is not mandatory and does not constitute a defect. Further, the complainant says the Teflon might have let g o due to previous plumber’s testings. The complainant engaged a building surveyor (EG) to comment on causation. In his report EG says given the age of the building the HWS would have been installed in accordance with the regulations at the time. The replacement tank has a catch tray installed beneath it. EG says, the main source of the water ingress appears to have come from the hot water tank area and spreading out from there. MPA says the drip or catchment tray has always been a requirement for internal hot water systems even prior to 1986. The insurer tendered the following documents:  Technical Solution Sheet – hot water plumbing  Melbourne and Metropolitan 17 December 1952 Gazette The plumbing code provided was updated in June 2014. The 1952 Gazette only refers to a tray being installed below the tank where the tank is installed between the roof and ceiling. According to EG and not disputed, the complainant’s HWS was on the floor o f an elevated house with an overflow provision discharging outside the building. I am not satisfied there is any evidence that the HWS had been incorrectly installed as claimed by the insurer. Some damage caused by wear and tear, gradual deterioration and lack of maintenance The insurer engaged a builder JL to reassess the causation and extent of damage to the complainant’s property. JL concluded:  the hot water system is leaking from the cold-water inlet in the form of a rusty stream of water  the absence of the drip tray caused the water to seep through the ground level causing structural damage  splash testing showed escape of liquid from the shower screen  the shower recess is in poor condition having cracked tiles and no silicone to the wall and corner joints The complainant does not dispute that there were issues with the shower recess having cracked tiles or there was a lack of silicone to the wall and corner joints. Determination | Case number: 538099 Page 5 of 9 I accept that the deteriorated state of the shower recess would have contributed to water damage. It is evident from the supplied photographs that the shower recess lacks maintenance work. The grouting had fallen from the joints, tiles were cracked and coming away from the wall where the silicone had given way on the shower screen. While the complainant’s builder (GC) disagreed with MPA , he did not supply any evidence to support his view. Further, the complainant did not offer any evidence of any maintenance work carried out to the shower recess. GC suggested a leak between the northern wall between the cistern stop and the bathroom basin. Further destructive investigation behind the wall revealed no leaks. I accept insofar as damage can be attributed to the leaking shower recess that such damage was caused by depreciation, wear and tear and not covered under the terms of the policy. Complainant has identified other sources of damage The complainant engaged a plumber JR to conduct further testing. In his initial report, JR says there is:  a leak on the flush pipe of the toilet which is continually dripping  a slight drip on a brass fitting connecting to the cold inlet of the hot water system as the Teflon has let go  a leak in the hot spindle. JR says this leak would not have shown up on the first pressure test as tapware were on the off position. The leak caused water to flow under the floor tiles and escape through the floor causing wide spread damage. JR tendered photographs showing the leaking pipe with the wall behind it being wet. The insurer did not dispute the newly discovered pipes have contributed to the claimed damage. T he insurer has not disputed JR’s causation report or contested his findings. I accept that damage was caused by the leaking fixed pipes. Fair in the circumstances that the insurer pays 50% of the damage Damage can have more than one cause. When deciding whether the policy covers the damage, we need to identify if possible what the proximate cause of the damage was. The proximate cause is not necessarily the first or last or the sole cause of the loss. It is the effective, dominant or operative cause of the loss. If there are several causes Determination | Case number: 538099 Page 6 of 9 operating at the same time, AFCA will consider each one to determine which cause set the train of events in motion. The available information is divided as to the cause of dam age. The complainant’s material establishes that most likely the cause of damage is from leaking pipes behind the shower tiles, a leak on the flush pipe to the toilet and leaking from the HWS. The insurer has not significantly disputed these findings. The insurer’s reports however suggest that the damage was caused mainly by the leaking HWS that had corroded and due to the leaking shower recess. I accept that if there are two equal causes of damage occurring concurrently, one of which is excluded, then the exclusion applies to defeat the claim. No timeframe has been placed around the timing of the leaks. The available information does not establish that the causes of damage occurred concurrently. I accept it is impossible for the parties to be able to clearly identify this. It is also difficult to conclude the efficiency of each separate leak or cause of damage in determining the extent of loss. Given the available information, I consider it fair that each party contribute to the cost of repairs. I consider it fair that the insurer pays 50% of the damage given it is not in dispute that at least part of the damage was caused by the leaking pipes that clearly falls within the terms of cover. JL tendered a scope of works and a quote totalling $51,977.57. Fifty percent of the quote is $25,988.79. The quote does not allow for builder’s margin or contingenc ies. I consider it reasonable to increase the settlement by an additional 15% or $3,898.32 to allow for such contingencies. The insurer is to pay the complainant $29,887.11 towards the water related damage. Interest is payable from 28 May 2018 being the date the claim was declined until payment of the claim. Policy provides cover for loss of rent The policy also provides cover for loss of rent should the property become uninhabitable because of a defined event damage. The level of cover depends on whether the property is on periodic tenancy or not. JL considered the property unliveable during the proposed repairs. JL estimated repairs to take approximately 90 days. Consistent with the above findings I consider it fair that the insurer pays for 45 days loss of rent being half of the estimated repair period. The complainant must provide the insurer proof of the periodic tenancy and loss of rent. Determination | Case number: 538099 Page 7 of 9 3 Supporting information 3.1 The determination is made under FOS Terms of Reference The Australian Financial Complaints Authority ( AFCA) has commenced managing disputes previously lodged with F inancial O mbudsman S ervice (FOS) . This determination is made under FOS Terms of Reference but has adopted the following terminology for consistency with AFCA. In this determination the AFCA terms have the same meaning as the FOS terms defined in paragraph 20.1 and Schedule 1, 2 & 3 of the FOS Terms of Reference. FOS definitions AFCA term applicant complainant financial services provider financial firm dispute complaint claim claim 3.2 Policy wording Term Water or liquid damage We will cover Loss or damage caused by water or liquid escaping from:  a fi xed pipe or an object attached to a pipe, fi xed gutter, fi xed tank or a drain  a bath, basin, sauna, spa, shower base or shower wall, sink, toilet or tiled fl oor that has drainage holes  a st andal one water tank  … Loss of rent We will cover: Any loss of rent equal to the weekly amount as stated on your Rent al Agreement or Periodic Tenancy Agreement for up to 12 months and a maximum of $52,000 if your buildings or sections of your buildings suffers loss or damage and are uninhabitable as a result. General Exclusions We will not c over any loss or damage as a res ult of, or caused by:  erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear  a defect in an item, structural defects, or faulty or poor workmanship or design Determination | Case number: 538099 Page 8 of 9 3.3 Key Documents Record Key points F inancial F irm ’s building consultant (BS ) 15 - 05 - 2018  The hot water servic e is located next to the shower recess in the bathroom and it does not have a drip tray under the unit. The hot water servic e was sighted as leaking from cylinder which has corroded du e to age.  Water esca pe from hot water service has caused considerable damage to the timber flooring. The water escape from shower screen is minor.  Pressure testing of pipe work did not identify any water escape. Complainant’s builder ( GC ) 21 - 05 - 2018  The water is leaking on the nort hern wall between the cistern stop and the bathroom basin connection (in the wall). The Plaster is decaying becaus e of the wat er, to a height of 150mm.  The escaped water is travelling under the substrat e that supports the tiles & is pooling below the H.W.S. where it is physically lower (because of no tiles). This is giving the impression to the casual onlooker that the H.W.S. is leaking  Your report also states that there is no tray under the H.W.S. This is not a common or mandato ry requirement.  The shower screen contrary to your report has the required seals under the door and has been adequately sealed to the tiles. Financial Firm’s builder (JL ) 07 - 09 - 2018  We found the hot water system to be leaking from the cold - water inlet in the form of a rusty stream of water.  We also conducted a splash test to the shower rec ess which had an escape of liquid from the shower screen. The shower recess was in poor condition having cracked wall tiles and no silicone on wall to base and int ernal corner joints.  We confirm having cut inspection holes around the toilet and vanity pipe work and found the wall cavity and bottom plat es to be dry. The plaster in these areas gave a high reading, however it is our professional opinion that this was caused by capillary action drawing moisture from the floor into the plaster Financial Firm’s plumber (MPA ) 05 - 09 - 2018  The hot water tank has a leak below the cold - wat er inlet and the insulation is wet at the cold - water connection point.  There is major leaking on the shower screen test, which caus es the leak below the hous e to become visibly worse. This seems to be coming through the tiles.  As instructed we have re - attended site and removed sections of plaster behind both the vanity and water closet.  On both occas ions we found the timber work to be dry and no visible water stains or water leaking from the lugged elbows.  The shower looks to have had no maintenance works carried out. The grouting has fallen from the joins, tiles are cracked, tiles are coming away fro m the wall and silicone has given way on the shower screen.  There is no silicone sealant behind the tap flanges.  Hot water service has not been replaced. Complainant’s plumber’s (JR) undated  We also conducted a visual ins pection through bathroom and toilet and discovered a leak on the flush pipe of the toilet that was continually dripping.  We discovered a slight drip on a brass fitting connecting to the cold inlet of hot wat er system, as the Teflon has let go. During the inspection we noticed a lot of moisture in the shower and a few Determination | Case number: 538099 Page 9 of 9 tiles starting to come away from the wall of the shower and cracking.  We then had further investigation and removed the tapware from shower and conducted a pressure test on the shower breach set and discovered the hot spin dle had a leaking body was her, which was continually leaking when shower taps are turned on. This would not have shown up on the first pressure test as tapware were on the off position.  This is resulting in a lot of moisture in wall cavity and in my opinio n, it is causing the water to flow under the floor tiles and escaping through floor wherever possible, causing a wide spread of damage. Complainant’s plumber’s (JR) undated  I discovered an issue with the fixed pipe behind the tiles between the hot water shower tap and the shower head. The leak I repaired was significant  When the hot water tap was turned on, the water was gushing from the pipe. This leak was by far the most serious leak in the house.  I believe this was not discovered previously because you need to have the tap turned on with the tap removed to be able to see the issue.  M PA would have needed to have had the hot water spindle turned on to complet e their hot water test. In this case, the other leak (that I discovered on the spindle ring) would have been leaking as well as the hot water servic e leak as part of this test.  If they had completed these tests they would have indicat ed that there are two leaks. The slight leak on the hot water service and the major leak elsewhere on the line that I di scovered. Complainant’s building surveyor (EG) undated  From the water ingress observed the main water source appears to have come from the hot water tank area and spreading out from there.  The potential source indicat ed the hot water service area.  In conc lusion if appears the damage sustained has been from a leaking hot water service which has spread out over the floor beneath the bathroom and toilet areas.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.