Home / Financial Firm (Unknown - Insurer) / Determination 537021
Determination 537021
Claim declined for water damage from plumbing faulty workmanship
Summary
The complainant's home insurance claim for water damage from a broken bath plumbing pipe was declined under the faulty workmanship exclusion. AFCA accepted the insurer's expert evidence that the plumbing was never properly connected and ordered no further action.
The insurer bore the onus on the faulty workmanship exclusion and showed on the balance of probabilities that poor plumbing workmanship caused the damage.
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination | Case number: 537021 Page 1 of 7
Determination
Case number: 537021 11 January 2018
1 Determination overview
1.1 Complaint
The complainant holds a home and contents insurance policy (policy) with the
financial firm (the insurer) and lodged a claim against the policy for water damage.
The insurer assessed the damage. It says while there is water damage, this occurred
as a result of a failure by the plumber to connect a pipe under a bathtub. It declined
the claim based on a policy exclusion for faulty workmanship.
The complainant says the insurer should cover the damage because it was caused by
water escaping from a broken pipe.
1.2 Issues and key findings
Can the insurer decline the claim?
The insurer is entitled to decline the claim because the available information shows
the cause of damage is faulty workmanship with the plumbing. This falls within a
policy exclusion.
1.3 Determination
This determination is in favour of the insurer.
The insurer is not required to take any further action
Determination | Case number: 537021 Page 2 of 7
2 Reasons for determination
2.1 Can the insurer decline the claim?
Onus on complainant to establish a claimable loss
It is accepted insurance law that the complainant first needs to show, on the balance
of probabilities, that the loss or damage claimed was caused by an event covered by
the policy. This is known as establishing a prima facie claim.
The complainant lodged a claim for water damage on 4 December 2017. This was
discovered after his son accidentally broke a tile. He says an inspection under the
house showed water had been escaping from the bathroom.
The complainant‟s policy covers loss or damage caused by a number of listed events
during the policy period. Relevant to this dispute is the listed event of „W ater and oil
leaks‟. This event covers loss or damage from water le aking or escaping from certain
items. This includes drainpipes, pipes or sanitary fixtures (such as baths).
The available information shows there is water damage to areas of the home (kitchen,
bathroom and laundry flooring) caused by a pipe. Consequently, I accept the
complainant has established a prima facie claim.
Insurer relying on a policy exclusion for faulty workmanship
The insurer says its expert reports show that:
there was faulty workmanship within the plumbing under the bathtub
this likely occurred during renovations carried out to the bathroom prior to the
complainant purchasing the property and incepting the policy
Based on this, the insur er says the complainant‟s claim falls within a policy exclusion
for loss or damage caused by faulty workmanship.
As the insurer is relying upon an policy exclusion, it has the onus to prove this
applies. The standard of proof is the balance of probabilities.
Parties have provided several expert reports
The insurer provided a report and email from builder (RB) as well as a report from its
internal assessor (JM) in support of its position. Key points in RB and JM‟s reports are
set out in section 3.2 of this determination.
RB concluded the damage was because a plumber had failed to connect the bath‟s
plug and waste to the pipe. This is faulty workmanship.
Determination | Case number: 537021 Page 3 of 7
The complainant obtained statements from three plumbers (BP, JW, and TB) that
confirm the pipe would have been connected and broke. Their evidence is also
summarised in section 3.2.
The complainant has also provided photographs showing the pipe was broken.
Evidence shows the cause of damage is faulty workmanship
Having carefully reviewed the available information, I note the following.
First, the complainant‟s plumbers all assume the bath plug and waste was connected
to a pipe. They did not actually observe this. The assumption appears to be based on
the fact the remnants of a cap and liner have remained in the broken pipe. This, of
itself, does not show the pipe was connected.
Further, RB makes a significant point. If the pipe broke and was connected, then the
other end would have been connected to the plug and waste. There is no evidence to
show that this is t he case. The complainant‟s plumbers do not address this point.
Second, RB notes there is no evidence of grime lines or colour variation from the
rubber washer. RB says this would always be evident when it is used. The
complainant says this would not be the case. However, none of his plumbers confirm
this in their reports or have done so in writing.
Third, RB says it is „very hard‟ to break a PVC pipe. TB believes it is possible if the
pipe is slightly off line. RB notes that even if that was the case, then it would be faulty
workmanship if it could break under normal pressure. There is merit to this point.
Having considered all the available information, I accept on balance the damage was
likely due to the fact the pipe was not connected. Even if I was to accept it was
connected, it was likely done in an improper way if it broke under normal use.
Therefore, I accept the insurer has shown the damage was caused by faulty
workmanship. As this falls within a policy exclusion, the insurer is entitled to decline
the claim.
Determination | Case number: 537021 Page 4 of 7
3 Supporting information
3.1 The determination is made under FOS Terms of Reference
The Australian Financial Complaints Authority ( AFCA) has commenced managing
disputes previously lodged with F inancial O mbudsman S ervice (FOS) .
This determination is made under FOS Terms of Reference but has adopted the
following terminology for consistency with AFCA. In this determination the AFCA
terms have the same meaning as the FOS terms defined in paragraph 20.1 and
Schedule 1, 2 & 3 of the FOS Terms of Reference.
FOS definitions AFCA term
applicant complainant
financial services provider financial firm
dispute complaint
claim claim
3.2 Expert report
Record Key points
Financial firm ’s expert ( RB )
Builder/Estimator‟s r eport
10 January 2018
inspection under the house found:
- plumbing/renovation done prior to the complainant purchasing the
property five years prior
- plumber “had forgotten to install s - trap to the bath in the main
bedroom and over time, whenever the bath was used the wat er
was escaping onto the floor below the bath… rather than going
down the sewer…”
flooring was damaged over time, structural int egrity compromised,
and replacement of both bat hrooms and a section of kitchen and
laundry flooring will be required
waste to the powd er room vanity also slowly leaking and had
“further exasperated the issue”
complainant would not have been aware of missing s - trap
no evidence trap was ever installed contrary to complainant‟s
claim at the time that it had fallen off. Even if it had fallen off, this
would be considered faulty workmanship
Financial firm ’s expert ( JM )
Internal assessor‟s r eport
22 January 2018
Observation and Site photos
Reviewed information, images and scope provided by RB
images show extent of damage to subfloor area of the home
notes RB‟s says floor waste to bath never connected, no sign of
the S trap lying on ground, and no evidence of adhesive glue to
Determination | Case number: 537021 Page 5 of 7
Record Key points
secure pipes together. JM suggests “this is generally BLUE in
colour with a PINK primer that is applied prior to pushin g and
securing together”
Recommendations
claim could be denied on being of poor workmanship or design
damage potentially started prior to inception of policy
obtain copy of pre - purchase ins pection report
Compl ainant’s expert (BP )
Plumber‟s statement
25 January 2018
inspection conducted 25 January 2018
bath connected “t hrough a 4 - way riser in the floor waste through a
P - Trap and into a sewer line”
“bath was connected through a 40mm M & F cap and lining”
“clearly pipe has broken at the cap and liner as p art of the cap and
lining are still evident in the pipe leading to the 4 way riser and
floor waste”
“plumbing has been done correctly and to the Plumbing Code
AS3500”
Complainant’s expert (JW)
Plumber‟s statement
29 January 2018
instruction – “ins pect and diagnose leak under main bathroom”
Findings:
- “all main bat hrooms sanitary fixtures have been plumbed to Code
AS3500”
- bath plumbed through 4way riser(FW)”
- “remnants of 40mmcap and liner appear to be broken off in the
40mm riser showing the bath was alwa ys connected upon
installation”
- “in my opinion all plumbing was complete and tested”
Complainant’s expert (TB)
Plumber‟s statement
“upon investigation under bathroom found all stack work installed
to AS3500”
“open up floor under bath waste and found 40mm cap & lining had
broken just above 40mmx88deg bend”
40mm pvc pipe between four way riser & bath is slightly offline
causing a slight pressure to cap & lining where screwed to plug &
waste. This could cause cap lining to crack & break over time. This
w ould cause flooding under bath & surrounding flooring under bath
& surrounding flooring under tile flooring”
Financial firm ’s expert ( RB )
Builder‟s statement
20 March 2018
reviewed the three plumbing reports supplied by complainant and
agrees bath waste is set to flow back to a four way riser whic h
meets the Australian standards
disagrees with reference in complainant‟s three(3) reports that the
pipe was connected bec ause:
- even if remnant from cap and lining, “it would take strong impact
to break the plumbing part (it is very hard to break a pvc pipe or
fittings) and if the waste was ever connected the other end would
still be attached to the bath plug and waste; otherwise t he bath
plug and waste would also be snapped off and the remnants on
the ground under the floor ‐ which it is not ” .
- there is no sign bat h waste was ever connected. “No grime lines
Determination | Case number: 537021 Page 6 of 7
Record Key points
or colour variation from the rubber washer which would be
between it and the cap and liner which ALWAYS happens when
the waste is used”
believed plumber set up plumbing correctly but appears:
- cap and liner were brok en during the bathroom construction
- possible oversight by plumber meant “the plug and waste was
never connected to any pipework”
In relation to complainant‟s fourt h plumber (TL) statement RB
disagrees with TL‟s hypothesis that a “40mm PVC pipe between
four way riser and bath waste being set slightly off line causing
slight pressure to cap and lining where screwed t o plug and waste.
This could cause cap and lining to crack and break over time” In
RB‟s view:
- slight pressure applied any where would not be enough to break
the fitting
- if cap and lining were “too far offline then a plumber would not
have been able to co nnect the waste”
- “ if the cap and lining was attached under enough
pressure that it snapped it would be the original plumbers liability
also due to incorrect installation”
unlike the complainant‟s plumbers RB says he is not hypothesising
about why waste was not connected, rather its conclusion is
“based on the evidence that the bat h plug and waste shows no
evidence of being connected and the photos of the bat h plug and
waste supplied by the plumbers confirm this also”
likely that if the complainant has co mmissioned a pre - purchase
building inspection, the issue would have been identified then
“in regards to the powder room leaking waste in the report I
originally supplied, it appears that the cap and lining rubber
washer may simply have perished or that the waste was installed
cross threaded. Of note, for reference to all the information above
about the bath waste the photo named “waste under powder room
leaking” is an excellent example of what a used cap and liner look
like”.
3.3 Relevant document
Complainant‟s submission
Insurer‟s submissions
Product disclosure statement (PDS):
The events we cover
We cover your home or contents when certain things happen. These are known
as 'listed events'. You can make a claim if a listed event takes place and causes
loss or damage to your home or contents during the policy period.
Determination | Case number: 537021 Page 7 of 7
(page 22)
Water and oil leaks
If loss or damage is caused by water or oil leaking or escaping from an item
shown in this section.
Covered
water leaking or escaping from:
– house gutters, drainpipes or pipes
– sanitary fixtures – for example, baths or toilets
…
(page 24)
Exclusions for all cover
These exclusions apply to all cover under your policy.
What we don’t cover
Loss, damage, injury or death arising from:
rust, corrosion, gradual deterioration, depreciation, wear or tear
…
Maintaining and occupying your home
We don't cover loss, damage, injury or death arising from:
faulty design or workmanship
…
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.