Home / Financial Firm (Unknown - Insurer) / Determination 529769
Determination 529769
Kitchen benchtop and cabinetry water damage claim declined
Summary
The applicant claimed for water damage to a kitchen benchtop and cabinetry that he attributed to a 2010 tap leak. The FSP denied the claim as gradual deterioration and lack of maintenance. AFCA found the evidence did not establish the 2010 leak as the proximate cause and that the FSP was entitled to deny the claim.
The proximate cause of the damage was on balance gradual deterioration excluded by the policy, and the lengthy delay in claiming made it impossible to establish what contribution the 2010 leak made.
Issues
- Claim denial primary · not upheld
“The FSP was entitled to deny the claim because the available evidence establishes the proximate cause was gradual deterioration over time, which is excluded from cover.”
- Inadequate claim investigation secondary · not upheld
“I accept there are some inconsistencies as highlighted by the applicant regarding the assessment reports.”
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
Case No: 529769 Determination Page 1 of 6
Case number: 529769 31 August 2018
1 Overview
1.1 Dispute
In August 2017, the applicant lodged a claim under a strata insurance policy
underwritten by the financial services provider (FSP) for damage to a kitchen
workbench and cabinetry. He says this was caused by a leaking tap back in 2010.
The FSP denied the claim saying the available evidence establishes the damage was
not a result of one incident, rather a lack of maintenance, wear, tear and gradual
deterioration over time which is excluded from cover under the policy.
The applicant disagrees with the FSP’s decision saying:
he has provided evidence of the tap being repaired back in 2010
whilst accepting the kitchen benchtop and cabinetry have naturally deteriorated
with age, he says the kitchen would still remain functional had the leak not
caused the localised damage now claimed
the assessment reports being relied upon by the FSP are contradictory.
For these reasons, the applicant expects the FSP to provide indemnity for the
damage attributable to the leaking tap.
1.2 Issue and key findings
Was the FSP entitled to deny the claim?
The FSP was entitled to deny the claim because:
due to the time now elapsed, there is insufficient evidence to establish the
proximate cause of the damage claimed was (on balance) a result of the leaking
tap back in 2010
the available evidence establishes the proximate cause of the damage claimed
was (on balance) gradual deterioration over time which is excluded from cover.
1.3 Determination
This determination is in favour of the FSP.
The FSP was entitled to deny the claim and is not required to take any further action.
Case No: 529769 Determination Page 2 of 6
2 Reasons for determination
2.1 Was the FSP entitled to deny the claim?
The applicant has an appointed representative in this dispute. For ease of reading,
both the applicant and his representative will be referred to as the applicant.
No dispute the kitchen has suffered damage
There is no dispute the applicant’s kitchen has suffered damage which is clearly
depicted in the photographs provided during the course of this dispute.
Applicant claiming for damage caused by 2010 water leak (not normal usage)
The applicant accepts that due to the age of the kitchen (approximately 30 years old),
damage has occurred as a result of general usage over time . He accepts the policy
does not respond to damage of this nature.
The damage being claimed for by the applicant is the additional damage he says
resulted from the leaking tap back in 2010. He says this is evident towards the rear
left side of the sink, consistent with it being the left tap that was identified as leaking
at that time.
With regards to that damage, the applicant says it occurred over a period of time
during 2010. He believes the leak was relatively minor to begin with, so not noticed
by the family of five residing at the property due to them all using the sink at different
times, and associated splashing of water. He says it was only identified by them and
reported to him once it had become significantly worse.
The applicant says he arranged for his handyman to attend to the leak as soon as he
was made aware of it, the associated invoice date being 30 November 2010. At the
same time, he says a metal bar was also siliconed into place in order to seal the gap
between the benchtop and the splashback, so preventing further water ingress and
damage to the support structure during normal usage of the sink.
The applicant says the kitchen would still remain functional had the leak not caused
the localised damage now claimed.
The applicant therefore seeks to have the FSP provide indemnity for the water
damaged benchtop area around the tap, the associated support structure and the
two cupboard doors beneath the bench.
FSP says damage a result of lack of maintenance/gradual deterioration
In support of its position, the FSP relies upon its assessor’s and builders’ reports
which are summarised in Section 3 below , along with the applicant’s own
kitchen/joinery specialist’s report .
It says these reports demonstrate the damage is a result of a lack of maintenance,
wear, tear and gradual deterioration over time.
Case No: 529769 Determination Page 3 of 6
Having come to this conclusion, the FSP relies upon the following policy exclusion to
deny the claim:
Exclusions – what we do not insure
1 We will not pay for loss or damage:
caused by lack of maintenance , … Wear, Tear, … gradual deterioration, developing flaws,
… or failure to maintain Your Insured Property in a reasonably good state of repair.
Applicant raises issue with inconsistencies between reports
The applicant says both the assessor (C) and builder (D) agree the bench top has
been damaged due to a slow leak over an extended period of time. This has since
been fixed and the reason why the bench top and cabinetry were dry when inspected
in 2018.
The applicant also raises issue with a number of inconsistencies between the
assessment reports being relied upon by the FSP. He notes:
D reports the sink cupboard carcass is damaged at the back , whereas the
builder (U) states no specific water damage was seen in this area
D reports the laminex top has deteriorated underneath the taps due to a long-
term water issue, whereas U states there was no damage in this area which
would be expected from such a leak
D reports the damage is likely a long-term leak from the spout, whereas U
deems it a result of general wear and tear
D reports relatively extensive water damage, whereas U limits the damage to
the vicinity of the left side of the sink
D reports water entering the cupboard below being a result of the damaged
laminex top, whereas U states it to be a result of the damaged splash back.
D reports that all cupboard doors are chipped, whereas U states that only the
doors beneath the sink are damaged.
The applicant also questions the independence of U ’s report saying C guided U’ s
negative conclusions. For example, he says U just accepted C’s suggestion that the
damage to the benchtop to the left of the tap spindle was too remote, and did not
independently consider the slope of the benchtop towards that area.
Proximate cause of damage claimed (on balance) gradual deterioration
I accept there are some inconsistencies as highlighted by the applicant regarding the
assessment reports.
However, the key issues the applicant faces in being able to establish the proximate
cause of the damage now claimed was the 2010 water leak include:
The applicant says that were it not for the 2010 leak, the kitchen would remain
perfectly functional/usable. However, it is unclear why the kitchen has only
recently become non-functional/unusable if the associated damage occurred in
2010. This suggests additional damage occurring during this intervening period.
If the benchtop sloped to the left as the applicant states, then this would
suggest water splashing from normal usage of the sink would also pool in this
same area to cause localised damage now claimed. Considering the leak went
Case No: 529769 Determination Page 4 of 6
unnoticed for a period of time due to regular usage of the sink, this would
suggest regular pooling of water from normal usage in this area.
The applicant arranged to have additional waterproofing measures installed in
2010 to prevent further water ingress into the cabinetry below during normal
sink usage. However, this suggests a pre-existing maintenance issue existed in
2010 allowing water to enter the cabinetry beneath, whether that water was due
to normal usage of the sink or the leaking tap.
Accepting (on balance) additional damage occurring from 2010 to 2017 as a
result of gradual deterioration, it is impossible to establish what level of
contribution (if any) the 2010 water leak had to the damage now claimed. The
significant delay in lodging the claim has not assisted in this regard.
For these reasons, I am not satisfied the available evidence is sufficient to establish
(on balance) the proximate cause of the damage now claimed was the 2010 leak.
Instead, I am more persuaded (on balance) from the available evidence that the
proximate cause of the damage now claimed is gradual deterioration.
FSP entitled to deny the claim
For all the reasons discussed above, I am satisfied the proximate cause of the
damage now claimed was gradual deterioration. As loss or damage arising from
gradual deterioration is excluded from cover under the policy, I am satisfied the FSP
was entitled to claim.
Case No: 529769 Determination Page 5 of 6
3 Supporting information
3.1 Expert reports
Record Key points
FSP’s a sse ssor (C)
Initial report
17 October 2017
There was various water damage to kitchen cupboards,
kickboards and to the kitchen benchtop in various sections.
Mould was identified growing underneath the kitchen bench.
A large amount of silicone and angle edge were observed on
top of the kitchen benchtop between the junction of the tiles,
benchtop and sink, but not to a professional standard.
The damage obs erved is consistent with long term wear and
tear a nd various wat er damage from splas hing and poor
kitchen usage.
The kitchen is past its serviceable life due to tenant neglect
and a lack of maintenance.
FSP’s builder (D)
Report
13 November 2017
It is very difficult to identify the cause of the damage because
the kitchen is very run - down and appears to have been
neglected for quite some time.
All the cupboards are chipped and flaking on the edges, the
laminex benchtop has deteriorated in the area underneath the
taps due to a long - term water issue and an aluminium angle
has been silicone d in position to prevent water entering the
cupboard below.
The joins in the benc htop are also swollen and the sink
cupboard carcass is water damaged on the back and shelf.
The sink cupboard and benchtop were bot h dry whe n
inspected.
The water damage has likely been caused by the spout to the
sink leaking over a long period of time causing the benchtop
to deteriorat e at the back edge and drip into the sink
cupboard below.
FSP’s a sse ssor (C)
Second report
5 December 2017
C laim denial should be maintained bas ed upon the further
findings of D.
The property is leased directly by the applicant (as opposed
to via an agent) and regular inspections would have revealed
the progressing neglect and lack of maintenance.
FSP’s a sse ssor (C)
Email
20 February 201 8
It can be clearly seen that there have been multiple leaks
over a long period of time and many attempts to repair the
severely deteriorated kitchen.
FSP’s builder (U)
Report
9 April 2018
Damage observed included a small section of water damaged
benchtop at the corner of the sink / staining to the underside
of the bencht op / water damaged chipboard strip to the
underside of the benchtop – damaged directly below the
corner of the sink.
There was no water damage observed to the corner
Case No: 529769 Determination Page 6 of 6
cupboard / under bench cupboard carc ass / rear panels near
to where the taps were located.
The cause of the damage is general wear and tear. The
majority of the kitchen cabinetry is approximately 40 years old
with the exception of the benchtop and sink which appear to
have been replaced following original installation.
The applicant raised his opinion during the inspection that the
water damage to the benchtop was due to a leaking tap
several years ago. There was no damage directly below the
tap s or to the carcass which would be expected from such a
leak.
The majority of the damage was to the left hand side of the
sink where there was significant damage to the splashback
and large amounts of mastic applied to prevent water from
leaking into the c upboards below.
There are numerous signs of the benchtop/sink joint and
benchtop/splashback joint being repaired with mastic and a
metal angle leading us to assume that these joints have been
leaking in the past. These repairs would act as ongoing
maintena nce to extend the life of the cabinetry.
It was also noted the top corner of the doors to the under sink
cupboard have worn significantly which has been caused by
water dripping over the edge of the benchtop onto the door
causing the door to swell and even t ually chip. Water was
observed dripping over the edge of the sink at the time of
inspection.
Applicant’ s
kitchen/joinery specialist
Report
4 July 2018
There is extensive water damage to the area between the
splashback and kitchen sink concentrat ed on the left hand
side, suggesting from a source such as a tap handle or
similar on the left hand side.
A metal bar has been placed over the wat er damaged area
and sealed to stop further water damage.
The benchtop is swollen and deteriorat ed due to water
absorption, hence the doors under the sink are worn.
In isolation of the obvious water damage around the kitchen
sink, the rest of the kitchen is in good order with still many
years of service life left.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.