Home / Financial Firm (Unknown - Insurer) / Determination 529707

Determination 529707

Insurer partly denied burst-pipe ensuite damage and limited liability to vanity unit only

FirmFinancial Firm (Unknown - Insurer)
Decided2019-01-17
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded$18,150
Non-financial loss$1,000
Amount claimed$18,150
SourceAFCA PDF

Summary

After a burst pipe the insurer accepted the claim but refused to reinstate the ensuite beyond the vanity unit. AFCA ordered the insurer to cash settle the ensuite for $18,150 and pay $1,000 for non-financial loss.

The insurer's removal of the vanity disturbed the tiled ensuite, and the policy covers the cost of meeting current building regulations to repair damaged parts of the home, so the partial denial could not stand.

Issues

Subjects and remedies

home or building damagepay claimpay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination | Case number: 529707 Page 1 of 6 Determination Case number: 529707 14 January 2019 1 Determination overview 1.1 Complaint The complainant lodged a claim on 14 July 2017 on her home and contents policy held with the financial firm (insurer) for damage caused by a burst pipe in her kitchen. The insurer accepted liability for the damage including contents damage but disputes the extent of damage to a bedroom ensuite. The insurer has accepted liability for damage to the vanity unit that it removed and offered to cash settle the complainant. The complainant says the insurer is responsible to reinstate the ensuite in accordance with the terms of the policy. The complainant also seeks compensation for the inconvenience and stress associated with the claims process. The Case Manager provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the complainant. A copy of the recommendation is attached to this determination. 1.2 Issues and key findings Were the findings of the recommendation correct? The findings contained in the recommendation were correct and are largely adopted in this determination. Further submissions provided after the recommendation have been considered. Is the Insurer entitled to limit its liability for damage to the ensuite? The insurer is not entitled to limit its liability for damage to the ensuite and is required to meet the costs to reinstate the ensuite including the cost to meet current building regulations. Is the complainant entitled to compensation? The claims handling has caused a considerable degree of inconvenience to the complainant and I determine the insurer pay the complainant $1,000 compensation for non-financial loss. Determination | Case number: 529707 Page 2 of 6 1.3 Determination This determination is in favour of the complainant. The insurer is to cash settle the claim for the ensuite for $18,150 and pay compensation of $1,000 for non-financial loss to the complainant. Determination | Case number: 529707 Page 3 of 6 2 Reasons for determination 2.1 Were the findings in the recommendation correct? This determination is based on what is fair in all the circumstances having regard to the relevant law, terms of the policy, good industry practice, codes of practice and prior determinations. I have considered all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. I am satisfied that the case manager‟s recommendation contains an accurate summary of the complaint, the issues to be determined, any applicable paragraphs of the Rules and any relevant law. 2.2 Is the insurer entitled to limit its liability for damage to the ensuite? Proximate cause of damage to the ensuite was the escape of water There is no dispute that a burst flexi pipe in the upstairs kitchen of the complainant‟s property led to damage to:  the upstairs kitchen, lounge and dining areas  formal dining and lounge room  entry hallway, downstairs hallway, staircase and upstairs hallway  downstairs bedroom, kitchen and lounge areas. The insurer‟s assessor noted:  the water had spread to the ensuite adjacent bedroom  there were early signs of water marks on the walls of the ensuite  there were above average water metre readings in the ensuite walls. OR confirmed damage to the vanity, gyprock and framework consistent with the insured event as well as finding mould which required some immediate remediation works. OR recommended the immediate replacement of the vanity but could not determine the extent of the damage until the damage at the back of the vanity was assessed. In December 2017 OR recommended:  removal of the gyprock wall and immediate remediation of the mould to the framework behind the wall  the waterproofing on the wall had been breached and a plumber needed to be engaged to fix the waterproofing and find the cause of the leak. IB removed the damaged vanity unit. In his report dated 25 January 2018 he notes that a standard vanity unit will not cover the exposed concrete flooring, that the vanity Determination | Case number: 529707 Page 4 of 6 cabinet had been tiled in, that is, installed before tiling and that water markings indicate the non-existence of waterproofing. I accept given these reports that there was damage sustained to the ensuite vanity and gyprock that required removal of the vanity and gyprock. I accept the leak detection report from SLD dated 17 February 2018 shows that there was a leaking shower recess. I am not satisfied that the report is sufficient to establish the proximate cause of the damage to the ensuite was the leaking shower recess. Whilst some damage may have been associated with the leaking shower recess the majority of the information indicates the water from the burst pipe spread into the ensuite causing the damage to the vanity and necessitating its removal as well as removal of some of the gyprock. The need to reinstate the ensuite is a result of damage to the vanity unit. The insurer as part of its investigation process and repair process removed the vanity unit. It was the removal of the vanity unit that has led to the need for significant work to be performed in the ensuite. Policy provides cover for the cost of meeting current building regulations There is no dispute that the waterproofing in the ensuite was either non-existent or had broken down. The insurer has argued that it is only responsible for the cost of replacing the vanity unit and that it is not responsible for repairing the surrounding areas as the insured event did not cause that damage. I do not agree with the insurer‟s argument. The policy provides that in the event there is loss and damage caused to the home and you need to meet current building regulations to repair and rebuild the part of the home that was damaged that the insurer will cover those costs. The available information indicates that to reinstate the vanity unit which was tiled in, it is necessary to replace the tiles. Photographs confirm that there is damage to some of the tiles as part of the removal process. If the tiles are replaced then it will be necessary to meet current building regulations with respect to the waterproofing in the area. The insurer says that the internal email of 26 February 2018 relates to the vanity only I do not accept this. The internal email clearly states as follows: I also await the costing to bring the bathroom and bathroom (my emphasis) to the waterproofing standards of today. As the vanity has been removed by CCP it is now up to us to bring it to code. I agree with the findings contained in the recommendation. Determination | Case number: 529707 Page 5 of 6 I am satisfied that an insured event has caused the damage to the ensuite and the actions by the insurer in removing the damaged vanity unit have caused further related damage that can only be repaired by meeting current building regulations. I am satisfied the insurer is liable to reinstate the bathroom to a similar condition to its pre-damaged state and be brought up to code. The complainant provided a quote from D for $18,150 to reinstate the ensuite. I have discussed this quote with the complainant and accept it is a fair quote. The complainant has expressed the view that she would like to have the complaint cash settled. I agree that this would be the best approach in this complaint. Accordingly, I determine the insurer cash settle the complaint for $18,150 in accordance with the quotation from D. 2.3 Is the complainant entitled to compensation? AFCA can award up to $3,000 compensation for non-financial loss under the FOS Terms of Reference as set out in the recommendation. Whilst the recommendation determined the complainant was not entitled to compensation I do not agree with that decision. In my view the insurer had the opportunity in February 2018 to settle the complainant‟s claim by reinstating the ensuite. The insurer chose at that time to deny liability based on a policy exclusion. It did so even though it had removed the vanity cabinet, that it was aware the vanity cabinet had been tiled in, that it was aware that the vanity unit could not be replaced without altering the tiling and that it was aware that the policy provided cover to meet current building regulations. I accept the complainant is expected to be moderately robust and bear a normal degree of inconvenience. I also accept that an insurer is entitled to form a reasonable view as to liability. In my view the insurer‟s handling of this claim has caused an unusual degree of inconvenience and stress to the complainant. Its decision appears to be based on a limited view of the terms and conditions of the policy without proper regard to the circumstances that have led to the damage. Taking from July to the following February to determine liability is in my view unreasonable. To ignore its own internal advice in February 2018 is also in my view unreasonable. In the circumstances I am satisfied the complainant is entitled to compensation for non-financial loss and determine the insurer pay the complainant $1,000 by way of non-financial loss. Determination | Case number: 529707 Page 6 of 6 3 Supporting information 3.1 The determination is made under FOS Terms of Reference The Australian Financial Complaints Authority ( AFCA) has commenced managing disputes previously lodged with Financial Ombudsman Service (FOS). This determination is made under FOS Terms of Reference but has adopted the following terminology for consistency with AFCA. In this determination the AFCA terms have the same meaning as the FOS terms defined in paragraph 20.1 and Schedule 1, 2 & 3 of the FOS Terms of Reference. FOS definitions AFCA term applicant complainant financial services provider financial firm dispute complaint claim claim Recommendation Case No: 529707 Recommendation Page 1 of 9 Case number: 529707 3 August 2018 1 Overview 1.1 Dispute Damage occurred to the applicant‟s home following a burst flexi pipe in her upstairs kitchen. She lodged a building and contents claim with the financial services provider (FSP). The FSP accepted an escape of water event occurred, causing damage to:  upstairs kitchen , lounge and dining areas  formal dining and lounge rooms  entry hallway, downstairs hallway, staircase and upstairs hallway  downstairs bedroom, kitchen and lounge areas The contents claim was accepted, and does not form part of this dispute. A week after lodging the claim, the applicant noticed damage to her ensuite and reported the findings to the FSP. It approved removal of a damaged vanity unit and offered a cash settlement for the applicant to buy a replacement vanity unit. 1.2 Issues and key findings Was a prima facie (valid) claim established? I am satisfied a prima facie claim was established. Is the FSP entitled to partially deny the claim? I have reviewed all material and submissions made by both parties. The FSP is not entitled to partially deny the claim. Is the applicant entitled to compensation? The applicant is not entitled to compensation for non-financial loss. 1.3 Recommendation This recommendation is in favour of the applicant. The FSP is liable for all damage to the ensuite, with no further excess payable. Case No: 529707 Recommendation Page 2 of 9 2 Reasons for recommendation 2.1 Was a prima facie (valid) claim established? A prima facie claim was established The applicant is required to show, on balance, she suffered a loss caused by a risk insured under the policy, i.e., a valid ( prima facie ) claim. If the applicant establishes a valid claim the onus shifts to the FSP to show, on the balance of probabilities, it is entitled to rely on an exclusion under the policy or it is otherwise entitled to deny or limit its liability for the claim. I am satisfied a prima facie claim was established. The FSP accepted many other damaged areas of the home due to the same escape of water event. 2.2 Is the FSP entitled to partially deny the claim? Escape of water event damaged the ensuite There is no dispute the insured event occurred. The FSP says the ensuite event- related damage is limited to only the vanity unit. The FSP‟s initial assessment (LF) confirms the insured event affected the ensuite. The report acknowledges some damage consistent with the claimed event, being:  flooding spread to the ensuite‟s adjacent bedroom  early signs of water marks on walls in the ensuite  above-average moisture readings in the ensuite walls. The FSP‟s later assessment report (OR) confirms damage to the vanity, gyprock and framework is consistent with the insured event. It also reports findings of mould and completed some immediate remediation works. OR suspects further mould is present behind the damaged wall and recommends a further inspection. OR says the existing waterproofing was breached and was the likely cause of the mould growth. An extensive amount of remediation works was identified, involving items beyond the damaged vanity unit. FSP disturbed the original condition of the ensuite OR‟s initial report confirms the vanity unit was unsalvageable. Prior to authorising removal of the unit, the FSP was aware the vanity was not of a standard size and was built into the tiled wall and floor surrounds. The FSP:  accepted the vanity unit was damaged by an insured event Case No: 529707 Recommendation Page 3 of 9  authorized removal of the damaged vanity unit  offered a cash settlement for the value of a replacement vanity unit. By removing the vanity unit, the rest of the ensuite was disturbed from its original condition. The FSP says it is not responsible for repairing the surrounding areas as the insured event did not cause any damage to it. It is reasonable to consider the insured event:  was the proximate cause of damage to the tiled surrounds resulting from removal of the vanity  such removal disturbed the existing waterproofing. Therefore, the FSP cannot deny the rei nstatement works on this basis. Building code at time of construction was met Upon removal of the vanity unit, the FSP identified waterproofing not up to current building code standards. It relies on inadequate waterproofing of the ensuite to deny cover for reinstating the bathroom to its original condition. It provided no evidence to show the ensuite was not built to the relevant code at the time of construction. The FSP also put the onus on the applicant to show the ensuite was built to the relevant code. The onus in fact rests with the FSP to prove this, not the applicant. I consider its request unfair, and demonstrates a poor claims handling process and assessment. Regardless, the applicant obtained material confirming relevant inspections were undertaken at the time of construction. The material shows no evidence of a failure to meet the relevant codes at the time. The FSP cannot rely on this exclusion to partially deny the claim. On balance, damage to architrave caused by the insured event Five months post claim lodgement, the FSP arranged an inspection (SLD) to locate the cause of damage to the architrave between the ensuite and bedroom. SLD‟s report confirms multiple methods were used to locate a leak within the ensuite. Non-invasive methods provided no results. Further testing resulted in:  high moisture readings in the walls directly below the kitchen above  lack of waterproofing under the tiles  leaking shower recess. The FSP maintains its denial to reinstate the ensuite because the policy does not provide cover for:  water damage from a shower recess  damage resulting from wear tear and deterioration. Case No: 529707 Recommendation Page 4 of 9 The report of SLD identifies a secondary proximate cause of damage which the FSP says is excluded under the policy. It refers to a long-standing principle of insurance law based on Wayne Tank and Pump Co Ltd v Employers Liability Assurance Corp Ltd [1974] QB 57 („Wayne Tank‟). Under the Wayne Tank principle, where there are two or more concurrent causes of the loss (one of which is an insured event and one which is an excluded event) the insurer is not liable to accept the claim. The applicant says she never experienced any issue with a leaking shower. She also says it is unrelated to the damage to the vanity unit and its tiled surrounds. It is reasonable to accept the water damage to the architrave was a result of water flooding the adjacent bedroom during the original insured event. Photographs from LF confirms the water inundation to the bedroom was significant, particularly at the doorway to the adjacent ensuite and architrave. FSP cannot rely on Wayne Tank principle to deny ensuite damage I believe the FSP sought SLD‟s report intending to seek a secondary excluded proximate cause to support its partial denial and avoid liability. I am not satisfied the FSP acted fairly in seeking SLD‟s report. The assessments already available at the time of seeking the report sufficiently support:  significant ensuite damage occurred because of the accepted insured event  ensuite damage beyond the vanity unit occurred  ensuite damage was not the result of wear and tear or gradual deterioration  ensuite damage was not the result of faulty design or workmanship. The FSP says the applicant did not provide anything to challenge its reported discovery of a shower leak. I am not convinced there was a need for the applicant to challenge the finding because sufficient material confirming the proximate cause of ensuite damage existed prior to seeking SLD‟s report. Therefore, the FSP cannot re ly on the „Wayne Tank‟ principle of law to support its partial denial. FSP is not entitled to partially deny the claim The policy says the FSP will bring damage caused by an insured event up to the current building code or standard. The FSP case worker also confirmed via internal email it is up to the FSP to bring the ensuite up to code following the removal of the damaged vanity unit. The material provided by both parties satisfies me an insured event caused damage to the ensuite. The actions of the FSP‟s removal of the damaged vanity unit caused further related damage. The FSP is required to accept the full loss for the ensuite. It is required to reinstate the bathroom to a similar condition to its pre-damaged state, and brought up to code. Case No: 529707 Recommendation Page 5 of 9 Alternatively, if the applicant wants to upgrade the ensuite:  a detailed scope of works is to be obtained  a cash settlement amount is to be calculated and agreed upon by both parties, ensuring it is actionable. 2.3 Is the applicant entitled to compensation? FOS may award compensation for non-financial loss Under the Terms of Reference, FOS may award compensation (capped at $3,000) for non-financial loss. FOS may decide an FSP should compensate an applicant for only where there has been an unusual amount of physical inconvenience, time taken to resolve a situation, or interference with the applicant‟s expectation of enjoyment or peace of mind. FOS takes a conservative approach to compensation for non-financial loss. It is not awarded for punitive purposes, but to compensate the applicant for their experience. The applicant is not entitled to compensation Applicants are expected to be moderately robust and bear the normal degree of inconvenience experienced when a problem occurs. In this case, the applicant‟s stress and inconveniences was due to the FSP‟s decision to partially deny her claim. Whilst the FSP‟s tactic to seek a secondary proximate cause was unsuccessful, FOS cannot award loss for punitive purposes. The circumstances do not warrant an award for non-financial loss. Case No: 529707 Recommendation Page 6 of 9 3 Supporting information 3.1 FOS approach to this dispute There has been a full exchange of material between the parties and opportunities provided to address any issues that may have arisen. This recommendation is based on what is fair in the circumstances, having regard to information exchanged, the policy, good industry practice and prior determinations where applicable. 3.2 Policy terms and conditions The PDS says: 5. General exclusions that apply to your policy These exclusions apply to all cover under your policy. What we don’t cover  Loss, damage, injury or death arising from:  rust, corrosion, gradual deterioration, depreciation, wear or tear  compensation for distress, inconvenience or other non-financial loss, except if covered under liability cover  faulty design or workmanship  you not maintaining your home in good repair and condition. This means your home must be watertight, structurally sound, secure and well maintained  you not maintaining your site in good repair and condition. Lifetime guarantee We provide a ‘lifetime guarantee’ when your home is repaired or rebuilt by one of our preferred repairers or builders. This means:  we guarantee the workmanship of repairs that we authorised for the lifetime of your home  we will fix any defect caused by poor workmanship. We will decide on what needs to be done to fix any defect. When you’re not covered by this guarantee Case No: 529707 Recommendation Page 7 of 9 This guarantee does not apply to:  … wear and tear that is consistent with normal gradual deterioration of your home. Fittings are any items that can be removed from your home without causing damage to your home. Fixtures are any items that are permanently attached or fixed to the structure of your home that cannot be removed without causing damage to your home. Policy term Covered Not covered Water and oil leaks If loss or damage is caused by water or oil leaking or escaping from an item shown in this section. Water leaking or escaping from: – house gutters, drainpipes or pipes – sanitary fixtures – eg, bat hs or toilets – appliances – eg, washing machines or dishwashers – waterbeds – aquariums – water tanks – swimming pools Oil leaking from a fixed heating system or sealed portable heater Costs to locate the cause of damage (if we agree to pay these costs before you make any arrangements). Water leaking or escaping from a: – shower recess or shower base – stormwater channel or canal – stormwater pipe off your site Costs to repair or replace the item that the water or oil leaked or escaped from loss or damage caused by floo d loss or damage caus ed by storm surge Meeting building regulations If a listed event causes loss or damage to your home and you need to meet current building regulations to repair or rebuild the part of your home that was damaged. The costs to meet current building regulations to repair or rebuild the part of your home that was damaged. Conditions We must agree to pay the costs before you make any arrangements. Costs to meet building regulations: – that were already in place when your home was buil t, renovated or altered – for undamaged parts of your home – eg, installing ins ulation in ceilings that were not damaged. 3.3 Reports relied upon Report Summary of content LF (FSP) Assessment report 14 - 09 - 2017  Broken flexi pipe in upstairs kitchen.  Home is in a damp environment.  Grey water affecting entire room. Case No: 529707 Recommendation Page 8 of 9  Builder‟s report not required to ascertain claimable event.  No mould infestation at the property that could impact the insureds health or safety.  Reported det ails are consistent with the claimable ev ent.  Rooms affected: Upstairs kitchen, upstairs lounge/dining combined Formal dining room, formal lounge room Entry hallway, upstairs hallway, downstairs hallway Staircase Downstairs kitchen/lounge combined Bedroom, ensuit e  Is any of the structure excluding the sub floor, for example the walls or ceilings affected by moisture? “Yes”  Structural drying required. Assessment report (FSP) Assessment report 25 - 09 - 2017  Early signs of water marks on walls directly beneath kitchen.  Water still dripping fro m architraves.  Carpet in master bedroom has been flooded due to water leaking in the kitchen above.  Early signs of water marks on walls in ensuite.  Damage is consistent with defined event.  Water still dripping from architraves in playroom below kitchen.  Mo isture readings of 25% on gyprock walls downstairs in the hallway, bathroom and master bedroom.  It is still early stages to determine the extent of the damage. OR (FSP) Assessment report Undated and unsigned  Engaged by IAL to report on mould growth – ensuite inspected.  Damage to inside of vanity is consistent with claimed event.  Vanity is unsalvageable and requires replacement.  Attended the site on 21 December 2017 .  Images and measurements taken by Oriel.  Mould cleaned by Oriel as much as possible.  Pro posed scope of works: inspect behind vanity for mould, and advis e on mould remediation.  Recommendation of immediat e replacement of vanity – highly suspect mould is growing below the vanity and beneath it which can cause a large issue in the future.  Cannot provide cost estimate until extent of damage is assessed at back of vanity. OR (FSP) Progress report Undated and unsigned  Attended the site on 27 (sic?) December 2017 : Photographs taken Report done for a job record Measurements taken Inspect behind the vanity for mould Advise on mould remediation  Reattended on 29 January 2018 and removed the vanity to inspect subfloor and gyprock.  Waterproofing on wall has been breached and shows elevated moisture content – believed to be reason for the mould growth.  Actions required: inspect behind vanity and clean/disinfect the area with microbial. Case No: 529707 Recommendation Page 9 of 9  Recommend: Removal of gyprock wall. Remediat e mou ld to framework behind the wall Sand and remediate framework Dry effected subfloor and interior wall Engage plumber to fix water proofing and find cause of leak  Assessment of ensuite complete but if mould is found to have spread behind walls on the frame a n updat e will be provided.  Estimated costs to attend to above: $2,009.51 (incl. GST). IWB (FSP) Plumber report 25 - 01 - 2018  Confirms removal of damaged vanity unit.  Vanity cabinet tiled in (installed before tiling).  Waterproofing applied only at wall/ floor strip.  Water markings in shower area indicate non - existence of waterproofing or breakdown.  Standard vanity unit will not cover exposed concrete flooring. SLD (FSP) Leak det ection report 17 - 02 - 2018  Inspection requested to locate water source causing the sl ight water damage to ensuite architrave surrounding the doorjamb.  Observes the ensuite vanity previously installed within the tiled bed has been removed by a third party.  No leaks detected using thermal non - invasive, tracer gas and acoustic methods.  Moistu re registered in bedroom architrave and carpet outside the ensuite upon spray testing the shower recess.  Water appears to be permeating through the tiled shower bed and tracking under the aluminum angle at the doorway most likely causing the damage.  90% an d higher moisture readings detected within the lower section of gyprock walls in dining room and bedroom surrounding the ensuite shower recess before and after completing the testing.  Moisture readings progressively decrease higher up the wall.  The WC appears to be leak free.  Shower recess failed flood testing, causing dampness to the architrave and damp bedroom carpet.  Tiled floor appears to be insufficiently waterproofed. Case Assessor (APP) Internal email 26 - 02 - 2018  I also await the costing to bring the bathroom to the waterproofing standards of today. As the vanity has been removed by CCP it is now up to us to bring it to code.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.