Home / Financial Firm (Unknown - Insurer) / Determination 525068

Determination 525068

Solar inverter storm water damage claim declined

FirmFinancial Firm (Unknown - Insurer)
Decided2018-09-05
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

A landlord's claim for a solar inverter damaged by storm water was declined. AFCA found sun damage to the inverter screens was the proximate cause of the water ingress, so the wear and tear and atmospheric exclusions applied.

Where the proximate cause of the loss is an excluded wear and tear or atmospheric condition, the claim falls outside the accidental damage cover.

Issues

Subjects and remedies

natural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 525068 Determination Page 1 of 4 Case number: 525068 5 September 2018 1 Overview 1.1 Dispute The applicant holds a home insurance policy (Policy) issued by the financial services provider. The Policy started on 21 March 2017 and covers the insured building for accidental damage. The building is occupied by tenants. On 2 January 2018 the applicant made a claim for damage to the solar system invertor. The applicant says the invertor was damaged during a storm. The FSP has denied the claim. It says the invertor failed because it was severely sun damaged, and this caused the screens water ingress properties to fail. The FSP says the proximate cause of the damage was wear and tear, and therefore the claim is excluded from cover. 1.2 Issues and key findings Has the applicant established a claim within the terms of the Policy? As the Policy provides cover for accidental damage, I am satisfied the applicant has established a prima facie claim. Is the FSP entitled to deny the claim? Based on the information provided, I am satisfied that had the condition of the screens not have been sun damaged, the storm water would not have entered. The FSP is therefore entitled to deny the claim. 1.3 Determination This determination is in favour of the FSP. The FSP does not need to take any further action. Case No: 525068 Determination Page 2 of 4 2 Reasons for determination 2.1 Has the applicant established a claim within the terms of the Policy ? The Policy provides cover for accidental damage The applicant carries the initial onus to establish any loss or damage arising from an event covered by the terms and conditions of the policy. This is known as a prima facie claim. Only once this is established does the onus shift to the FSP to show, on the balance of probabilities, the loss falls within an exclusion of the policy. The applicant’s policy is an accidental damage policy. This means the policy responds where damage to the insured property is caused unintentionally, subject to any exclusions. There is no dispute that the damage was unintentional and I am therefore satisfied that the claim falls within the scope of cover offered under the Policy. 2.2 Is the FSP entitled to deny the claim? The Policy excludes loss or damage caused by wear and tear The Policy contains exclusions. The product disclosure statements (PDS) says the Policy does not cover: Loss, damage, injury or death arising from:  rust, corrosion, gradual deterioration, depreciation, wear or tear  atmospheric conditions or extreme temperature To decline the claim, the FSP must show on balance that the proximate cause of the damage claimed falls within one of these exclusions. It is well established that a proximate cause is not necessarily the first or last or the sole cause of the loss. It is the effective or dominant or operative cause of the loss. If there are several causes operating contemporaneously, then each must be examined for the qualities of predominance and efficiency as the active efficient cause that sets a relevant chain of events in motion. Courts have said that if one cause would have resulted in the harm in any case and the other would not have done so in the absence of the first, then the first is the proximate cause. Case No: 525068 Determination Page 3 of 4 The information provided shows proximate cause of damage is sun damage The following reports and opinions have been considered: Date Report 22 Jan 2018 FSP report provided by RA (Solar Technician): Upon testing the systems it was found that one (1) of the three (3) inverters installed on site was in an error state after further investigation it was found that the inverter has failed with unrepairable internal faults due to water ingress and needs to be replaced. It should also be noted that all three (3) inverters installed at this address show severe signs of sun damage. This has caused the screens water ingress properties to fail, if left in this state it will not take long for the two (2) working inverters to fail. 13 June 2018 Email from RA to FSP: as mentioned above the o verall positioning directly affects the lifespan and integrity of an inverter. most if not all manufacturers will have in their installation guidlines the the inverter shall "NOT" be installed in direct sun. it is apparent that the inverters in question ha ve been installed on a northern facing wall with no protection from the sun. in my professional opinion this is the definitive reason the inverters have failed, succumbed to premature lifespan or show signs of preventative damage. as stated in the informat ion provided the system has a 10 Year workmanship warranty, i believe there is evidence of poor workmanship to be the direct cause of the inverter to fail. as the installers should of been aware of such manufacturers recommendations apon install that a sha de or cover should have been installed to prevent the premature failure of the screen protectors as a minimum. (sic) 13 July 2018 Applicant report provided by SS (Solar & Electrical specialist): The inverter installation at the time met Australian standards. Solar inverter failed due to water egress. The fault is unrepairable due to main board corrosion. Tthere was no discernible location identified as a point of water egress. Seals were in ok co ndition. The unit is IP65 rated (low pressure water protection) making the likely cause storm damage in the form of excessive water exposure. (sic) The applicant says that while he appreciates and acknowledges that the screens have cracked due to the sun, this is not what caused the unit to fail. He says the water entry from the storm of the caused the unit to fail because:  the unit is only three to four years old  it is designed to operate for well over 10 years, and  the water pressure testing is low pressure opposed to first report stating its high pressure. The FSP asked RA if water pressure could have penetrated the product if it was not damaged before the storm. RA said this was not possible because: Case No: 525068 Determination Page 4 of 4 the inverters in question have an IP (ingress protection) rating of IP56. this rating means that when installed correctly the inverter is protected from water ingress from strong jets of water from all directons. this is given by the number "6" in its IP rating of "56" (sic) The FSP says the IP rating was IP56. The applicant says the rating is IP65. The first digit relates to protection from solids. 5 being dust protected and 6 being dust tight. The second digit relates to protection from liquids. 5 being water jets and 6 being powerful water jets. Even if the IP rating was IP65 denoting a lower rating for water protection, I am not satisfied that this means that the proximate cause of the damage was the force of the storm water. This is because based on the information provided, I am satisfied that had the condition of the screens not have been sun damaged, the storm water would not have entered. The FSP is therefore entitled to deny the claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.