Home / Financial Firm (Unknown - Insurer) / Determination 523889

Determination 523889

Home water damage claim declined under soil movement and pre-existing damage exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2018-11-01
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

After a sewer blockage flooded beneath the home, the insurer declined the water damage claim as pre-existing soil movement. AFCA found the escape of water caused new damage that is covered and ordered the insurer to scope and settle that damage and remediate under the house, but not to re-level the subfloor.

The insurer could not show on the balance of probabilities that an exclusion was the proximate cause of the new damage caused by the water escape.

Issues

Subjects and remedies

home or building damagepay claimrepair or rectify

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination | Case number: 523889 Page 1 of 13 Case number: 523889 31 October 2018 1 Determination overview 1.1 Complaint In July 2017, the complainant lodged a claim on his home building insurance policy after the insured property was damaged by water and effluent leaking from a sewer pipe. The financial firm (insurer) declined the claim because:  the building damage was pre-existing  the proximate cause of the damage was soil movement over a lengthy period  the policy excludes cover for damage caused by soil movement. The complainant disputes this decision and says the proximate cause of the damage is escape of liquid from a blocked sewer pipe and seeks the insurer accept the claim. 1.2 Issues and key findings Has the complainant established a valid claim? The complainant ’s policy covers accidental loss or damage, defined as being damage which is caused unintentionally to the home. There is no dispute among the parties that the damage sustained to the property due to the escape of liquid was unintentional. The complainant has therefore established a valid claim under the policy. Was the insurer entitled to deny the claim? The property had suffered from cracking prior to the recent event with evidence of previous repairs. The insurer is not liable for pre-existing damage. However, the available material establishes the escape of water contributed to the damage and caused new and additional damage. The proximate cause of the additional and new damage which occurred after the escape of water event is accidental and covered under the policy. The available material does not establish on the balance of probabilities exclusions apply to this new and additional damage to defeat the claim. Determination | Case number: 523889 Page 2 of 13 1.3 Determination This determination is partly in favour of the complainant. The insurer is to prepare a scope of works for the damage described to the builder and the engineer by the complainant (and described by the engineer in his report) and settle the complainant as per the terms of the policy. If required, the insurer is also to apply a layer of Airex Chemical to the soil and property surrounds. Determination | Case number: 523889 Page 3 of 13 2 Reasons for determination 2.1 Has the complainant established a valid claim? Complainant established a valid claim under the policy The responsibility is on the complainant to show, on the balance of probabilities, a claim within the terms of the policy. This is commonly called a valid (or prima facie ) claim. Once established, the onus shifts to the insurer to show on the balance of probabilities it is entitled to rely upon a condition or an exclusion to deny the claim. The complainant ’s policy provides cover for accidental loss or damage, subject to th e conditions and exclusions set out in the policy. The policy defines accidental loss or damage as damage which is caused unintentionally to the home. There is no evidence which establishes the complainant intended this damage to occur. On this basis, I am satisfied the complainant has established a valid claim. It is not in dispute in July 2017, there was escape of liquid and effluent from the mains sewer which was blocked and the effluent and water flowed into and under the complainant ’s entire home. The complainant asks his house to be put back on the condition it was before the event. He requests:  damages to his home be repaired  the sub floor be re-levelled  any other relevant repairs, suggested by an impartial builder, be completed. As I am satisfied the complainant has established a valid claim, the onus shifts to the insurer to show, on the balance, policy exclusions apply to defeat the claim. 2.2 Was the insurer entitled to deny the claim? Onus shifts to the insurer to establish policy exclusion applies The insurer has relied on exclusions, namely:  rust, corrosion, gradual deterioration, depreciation, wear or tear  settling, shrinkage or expansion in buildings, foundations, walls or pavements  faulty design or workmanship  previous damage which has not been repaired  not maintaining the home in good repair and condition  damage not caused by one-off incident. Determination | Case number: 523889 Page 4 of 13 To deny the complainant ’s claim, the insurer must show these factors were the proximate cause of the damage (the real, effective or dominant cause). The insurer engaged experts to assess the property and report on the cause of the loss. Damage as described by the complainant The complainant is not claiming the entire house sustained damage after the escape of liquid. In correspondence with the insurer, he has identified the following occurred within the short duration after the subject event. He says:  the bathroom is no longer sealed as tiles are coming off the wall  the condition of the house had changed since the claim event  all the doors closed and the tiles were not falling off the wall before the event  the bathtub had cracked  the painted concrete on the rear porch was scratched due to the screen door sliding along the ground. At a reinspection shortly after the event he showed the builder the following:  the lock does not line up on the front door  the lounge sliding door is closing with a gap to the top  the bathroom and bedroom doors are sticking and jamming to the frame  there are several cracks to the lounge walls and other rooms. The complainant described grey water coming out of inspection point and gullies and even up through the toilet bowl. The complainant ’s plumber (JP) says: Due to main sewer being blocked and overflowing from council manholes in the street this has caused a lot of sewerage to overflow from the lowest point on the client’s property and to not only overflow around the property but also to flood underneath the property causing stagnant sewer build -up underneath the property without anywhere for it to escape to. The whole property is covered with sewer underneath the building and also around the whole property. Insurer ’s expert’s findings The insurer ’s technicia n (A) identified other water leaks in the laundry, kitchen and bathroom and says the sewer main was completely full and holding water. The identified leaks would only occur should water level rise to certain levels. The builder and restorer initially engaged by the insurer could not comment on causation. The insurer engaged an engineer. Determination | Case number: 523889 Page 5 of 13 The engineer photographed and described the damage. He also undertook a level survey. His findings are summarised in supporting section 3 of this determination. The engineer noted previous repairs and subsequent compression cracking which he said indicated the house suffered effects of soil movement over time. The engineer’s initial findings were based on the water moving under the house in a limited area. However, the complainant ’s plumber who attended the property soon after the event, confirmed the water flowed under the entire home and around the whole property. The engineer reconsidered and said in that case he would have expected the soil movement to be relative and potential footing movement equal rather than specific as indicated by the level survey. When he reviewed the damage and floor level survey he could see no correlation between the flooding and damage. He maintained the most likely cause of damage was the large trees at the front of the property causing a net drying effect leading to settlement and subsequent damage. Water inundation under the house was extensive I note the engineer’s initial assessment was incorrect because he did not consider the extent of the water which escaped and how it spread under the property. The complainant told the insurer the water pooled under the house for days and he only lodged the claim once he noticed water coming up from the toilet. Relying on the complainant ’s statemen t and the complainant's plumber's report, I accept there was a significant escape of water which effected all the property and which would have saturated the clay/soil foundations. Proximate cause of the new and additional damage was the claimed event Having reviewed the engineer’s report carefully, I accept the levels are uneven and in particular, the western side of the property is subsiding in the direction of the trees. Further, I accept the engineer’s observations there was evidence of previous rep airs. But, as pointed out by the engineer, the results of the water leak survey are ambivalent as areas around the laundry and the western elevation (where storm water was said to discharge) are negative and the highest recorded level corresponds with bedroom 3 where there is no leaking water. Moreover, the engineer conceded the effluent leaking under the floor may have contributed to an already significant soil moisture imbalance caused by a combination of the other identified leaks and stormwater discharging direct to the ground and the constant moisture demands of the trees at the front of the property. Taking these matters into account, and in particular the inundation sustained to the property over several days, I am not satisfied the new and additional damage was Determination | Case number: 523889 Page 6 of 13 caused by an excluded event. I am satisfied on the balance of probabilities the proximate cause of the new and additional damage was the water escaping event. Wayne Tank principle has no application The insurer has argued the application of the Wayne Tank principle. Where two concurrent proximate causes operate interdependently to cause a loss and one of the proximate causes is excluded (while the other is insured), the insurer is entitled to rely on the excluded cause to deny liability. Given the finding I am satisfied the property was inundated with water as a separate event, I am satisfied the Wayne Tank principle has no application to the circumstances of the complainant ’s loss. Insurer to prepare scope of works for new and additional damage I am satisfied the insurer is liable to accept new and additional damage which occurred after the escape of liquid event. The parties have not provided specific information about the new and additional damage or the cost of repairs. The complainant identified new damage which is set out in the builder’s report dated 15 August 2018 and which is described in the correspondence in the engineer’s report dated 17 May 2018. In addition, the engineer described damage in his first report which is set out i n supporting section 3 of the determination. The insurer should prepare a scope of works for the damage described to the builder and the engineer by the complainant (and described by the engineer in his report) and settle the complainant as per the terms of the policy. Insurer not liable to re-level the subfloor The complainant claimed the subfloor was to be re-levelled. However, in view of the other competing forces and the significant difference in the floor level survey from one side of the house to the other, I am not satisfied the available material establishes on the balance of probabilities the escape of water event was the proximate cause of this claimed damage. If not already done, remediation required around and under the house SA water attended the property after the inundation and cleared the pipe blockage. It also sprayed disinfectant around the house as a temporary measure. There was evidence the water travelled in the soil under the entirety of property, but there was no longer a smell and no evidence of raw sewerage. In addition to the wash down by SA Water, the insurer ’s expert (S) recommended the application of a layer of Airex Chemical. If this is required, the insurer should attend to this as well, as I am satisfied it is fair in the circumstances to remediate around and under the house. Determination | Case number: 523889 Page 7 of 13 3 Supporting information 3.1 The determination is made under FOS Terms of Reference The Australian Financial Complaints Authority ( AFCA) has commenced managing disputes previously lodged with F inancial O mbudsman S ervice (FOS) . This determination is made under FOS Terms of Reference but has adopted the following terminology for consistency with AFCA. In this determination the AFCA terms have the same meaning as the FOS terms defined in paragraph 20.1 and Schedule 1, 2 & 3 of the FOS Terms of Reference. FOS definitions AFCA term  applicant  complainant  financial services provider  financial firm  dispute  complaint  claim  claim 3.2 AFCA Approach There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any issues raised by the other. All the material pro vided by the parties has been reviewed and considered for the purposes of this determination. This complaint has been decided on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. It is an accepted principle of general insurance law that an insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. Determination | Case number: 523889 Page 8 of 13 3.3 Proximate cause Case law establishes:  the proximate cause of loss is the dominant (or effective or operative) cause of the loss, if the cause is last in time or the sole cause  where several causes operate at the same time, each cause must be examined for the qualities of reality, predominance and efficiency as the active, efficient cause that sets a relevant chain of events in action  If one cause results in harm in any case, and the other would not in the absence of the first, the first is the proximate cause  a common-sense approach is taken to determine proximate cause. 3.4 Key policy wording The relevant policy extracts are referred to in the insurer ’s Notice of Response dated 1 June 2018. Both the policy document and the Notice have been exchanged with the complainant. Definitions Accidental Damage is damage that is caused unintentionally to your home or contents. Accidental damage is not covered under any of the listed events (see Table 3.1 – page 23). Accidental damage You can choose to cover your home and contents for accidental damage — that is, mishaps around your home that are caused unintentionally. Covered under Buildings Insurance damage to your home that is caused unintentionally … Exclusions for all cover These exclusions apply to all cover under your policy. What we don’t cover Loss, damage, injury or death arising from: Determination | Case number: 523889 Page 9 of 13 rust, corrosion, gradual deterioration, depreciation, wear or tear (….) the settling, shrinkage or expansion in buildings, foundations, walls or pavements (….) pollutants or contaminants that discharge or escape Maintaining and occupying your home What we don't cover loss, damage, injury or death arising from: • faulty design or workmanship • previous damage that has not been repaired (….) • you not maintaining your home in good repair and condition. This means your home must be watertight, structurally sound, secure and well maintained Incident is a single occurrence, or a series of occurrences arising out of the one event. 3.5 Key records Record Key points Complainant ’s plumber’s (J) Report 1 August 2017  Inspected and photographed 1 August 2017.  Due to main sewer being blocked and overflowing from council manholes in the street this has caused a lot of sewerage to overflow from the lowest point on the client’s property and to not only overflow around the property but also to flood underneath the p roperty causing stagnant sewer build - up underneath the property without anywhere for it to escape to. The whole property is covered with sewer underneat h the building and also around the whole property. I nsurer ’s builder (UB) Report 3 August 2018  Met comp lainant 2 August 2017.  Complainant said the sewer/storm wait er blocked down at the neighbor’s house/street causing grey water to come through Determination | Case number: 523889 Page 10 of 13 Record Key points the external inspection points and gullies of the house.  Complainant called plumber and SA water who attended and found a blockage to the SA water pipes. SA Water has attended, cleaned the pipe blockage and sprayed disinfectant (or similar) around the hous e a temporary measure.  Conc ern regarding grey water which has gone all the way around the external pat hs, garden a nd lawn areas, underneat h the property to the soil of the transportable.  Resultant damage is due to a water escape/blockage form SA Water pipework which has caused the grey water to come out of the gullies, inspection points and even up through the toilet bowl.  Complainant has photos of the grey water coming up from the traps and toilet.  SA Water has attended to clear blockage and do minimal cleaning.  No building damage at time of inspection to the transportable house.  Possible contamination of paths and soil underneath the house, restoration company or SA Water to inspect. I nsurer ’s expert (UB) Report 15 August 2018  Re - inspected 15 August 2017.  Shown the front door where the lock doesn't line up, out about 5mm, the lounge sliding door is closing with a gap to the top, around 5 - 10 mm and other bathroom and bedroom doors which are now sticking and jamming to the frame.  Noticed several cracks to the lounge walls and ot her rooms.  Due to the age of the transportable house (approx.) 50 - 60 years, the pre - existi ng condition of the property, unable to determine if the piers to the house have been damaged by the flooding.  Resultant damage: To be confirmed by specialist engineer.  Caus e of damage: To be confirmed by specialist engineer.  Pressing uns ure due to the ag e of the transportable house, possible pre - existing damage, water underneath the house from claimable event, specialist to determine if movement to doors, wall cracks associated with this claim or general movement. Specialist to determine is under pinning is required if claimable, and provided scope of works for underpinning, internal repairs.  We have selected 'Claim - Unsure - Specialist required' and will not be proceeding with repairs. I nsurer ’s expert (S) Report 8 August 2017  Water has travelled from several drain loc ations associated with the property and travelled underneath the property as property is on stilts.  Evidence of wat er having travelled in soil underneath property but there is no longer a smell of any kind and there is no evidence of raw s ewage to dat e. Determination | Case number: 523889 Page 11 of 13 Record Key points  IICRC standard deems this event to be category 3 water contamination and therefore requires migration action as outlined further in report.  Insured is concerned that house structure has changed since event, such as front door and internal sl iding door are no longer aligned as before, we have taken photos of structure but would need to gain a structural engineer to determine sound footings.  Engineer to review structure and assess for movement and possible retention issues.  Soil has been alleg edly treated prior to visit by insured with gerni with wash down hose, we recommend a layer of Airex Chemical to ensure no further odor is evident going forward if required, this would take approx. two technicians for one day to complete at standard labor rates, plus PPE and chemicals. I nsurer ’s water damage investigation report (A) Report 22 September 2017 Sewer main was completely full and holding water. S arranged for SA Water to attend to clear sewer main. Located about 8.9 m from the complainant ’s WC. LAUNDRY  Head test laundry trough waste to external gully - Result - Static  Head test laundry external gully - Result - Head loss recorded. Extended testing located leakage of approximat ely 3 litres per minute from gully riser to collar and grate. KITCHEN  Head test kitchen waste to external gully - Result - Static  Head test kitchen external gully - Result - Head loss recorded. Extended testing located leakage of approximat ely 5.5 litres per minute from riser to domestic sink connection. Note: Again, this le akage would only occur should water level rise to this level. BATHROOM  Head test basin waste to external gully - Result - Head loss recorded. Extra testing located leak age  from basin waste to gully connection.  Head test bath waste to internal trap ris e - R es ult - Leakage recorded Extended testing located  leakage from bath plug and was her to cap and lining.  Head test bathroom floor waste to external gully - Res ult - Static W/C  Head test w/c branch from w/c IP - Result - Head loss of approximately 2.5 litres per minute rec orded. I nsurer ’s Forensic Engineer (FE) Report 31 August 2017  Attended and photographed 24 August 2017.  Undertook level survey and noted soil type and trees proximat e to house.  Complainant said leaking effluent ponded around north - east Determination | Case number: 523889 Page 12 of 13 Record Key points corner.  Noted previous repair and subsequent compression cracking which indicates hous e suffering effects of soil movement over time.  Positive levels along the eastern side may actually be truer representatio ns of the original data level suggesting footings have settled towards the direction of the trees and large shrubs situated at front of the property which dry the soil. General Observations and Di stre ss Observed 1. The door leading into bedroom 2 appears to be out of square with the frame. [1} 2. The patio door leading into the sun lounge is out of square with the frame. [2] 3. The lock to the entry door in the sun lounge has become misaligned. {3} 4. Vertical crack above the sun lounge door. [4] 5. Vertical cracking above the doorway leading into the main hallway. [5] 6. Vertical cracking above the bedroom door. [6] 7. Vertical cracking above the bathroom window. [7] 8. Vertical cracking above the door leading int o the kitchen. {8} 9. Compression cracking above the doorway. {9} 10. M isaligned floor tiles in the bathroom. {10} 11. Several skirting tiles have delaminated in the bathroom. [11) 12. Poor quality tiling around the floor drain. [12] 13. Wall tiling requires re - grouting and re - sealing. [13, 14} 14. View showing the sub - floor area. [15 - 18} 15. Co rrosion was noted to the sacrificial steel form beneath the bathroom. {19} 16. Several trees and large shrubs within relatively close proximity to the subject residence. [21 - 22] I nsurer ’s Forensic Engineer (FE) Report 19 October 2017  Reviewed water damage inv estigation report. Report identified leaks in areas adjacent to where the levels are negative save for bath and WC. Highest level corresponds with bedroom 3.  Identified leaks would have been discharging to the ground for far longer a period than a one - off sewer back up.  Cannot find any correlation with the effluent released towards the north - east corner of the building and the cracking/movement of the residence, and reiterat e that the presence of compression cracking and evidence of previous repairs suggest that the residence has been suffering the Determination | Case number: 523889 Page 13 of 13 Record Key points effects of soil movement over a lengthy period.  At worst the effluent leaking under the floor may have contribut ed to an already significant soil moisture imbalance, caused by a combination of the other identified leaks and storm water discharges direct to ground and the constant moisture demands of the trees situated at the front of the property. I nsurer ’s Forensic Engineer (FE) Report 17 May 2018  Engineer addressed points made by the complainant particularly that water spread over all of the subfloor - engineer expected soil movement to be relative and potential footing movement to be equal rather than being specific.  Viewing damage and floor level survey can see no correlation between flooding and distress now evident and maintain most likely cause of damage is the large trees at the front of the p roperty causing a net drying effect leading to settlement.  Shrubs and foliage have not played any significant part in the movement of the footings.  Once leak repaired, effluent subsided, would expect wet soil to dry, swelling to subside and cracking to c lose but as this is not so and the distress is still as bad or worse than at the time of the leak event, indicates house is being influenced by a more constant cause - seasonal soil moisture variations made worse by the trees at the front of the property. 3.6 Other relevant material considered and relied on  Parties’ submissions, emails and photographs.  Correspondence between the parties.  Insurer ’s file notes.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.