An investment property owner claimed for movement and cracking damage, and the insurer partly accepted the claim for damage caused by a leaking kitchen waste pipe. AFCA preferred the insurer's engineer, found the leak caused only part of the damage, and ordered indemnity for the leak-related damage with no cash figure stated.

The applicant must show a prima facie claim from an insured event, and damage from soil, drainage and foundation movement was not shown to be caused by the insured leak.

Issues

Subjects and remedies

home or building damagepay claimrepair or rectify

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 519806 Determination Page 1 of 4 Case number: 519806 25 September 2018 1 Overview 1.1 Dispute The applicant lodged a claim for movement and cracking damage to her investment property with her insurer, the financial services provider (FSP). The FSP initially denied the claim. During the course of the dispute though, the FSP partially accepted the claim based on damages it says were caused by a leaking kitchen/laundry waste pipe. The applicant disputes this and seeks all of the damage to be covered. 1.2 Issues and key findings Is the FSP liable for all of the damages to the property? The FSP is not liable for all of the damages to the property. This is because the evidence does not show it was all caused by the leaking pipe. The FS P’s liability is limited to the damage engineer MI said was caused by the leaking kitchen/laundry waste pipe. 1.3 Determination This determination is partially in favour of the applicant. The FSP is to indemnify the applicant for the damage MI said was caused by the leaking pipe. Case No: 519806 Determination Page 2 of 4 2 Reasons for determination 2.1 Is the FSP liable for all of the damages to the property? Applicant must establish a prima facie claim The applicant is required to show, on the balance of probabilities, she has suffered a loss caused by an event that is insured under the policy (insured event). This is known as a prima facie claim. MI’s report is preferred The FSP has provided reports from two engineers, JJ and MI. I have carefully reviewed their evidence. I prefer MI’s evidence for the following reasons. First, and of significance, MI has taken into account more relevant factors. This included the identification that the external right and rear perimeter of the property had concrete paving which was removed in 2012. As explained in the report, the ground to the external perimeter of the house can have an influence on the footing’s performance. JJ did not take this relevant factor into account in his report. Second, MI said that whilst the kitchen/laundry waste leak will have increased the soil moisture in its vicinity, this does not explain the cracking throughout the house. This is plausible. His concern is also supported by the change in the external perimeter. This explains why the property’s footing performance changed recently. The a pplicant argues the pipe was the main cause. However, I prefer MI’s evidence as he is an engineer and qualified to provide an expert opinion on this issue. FSP is to indemnify the applicant for damage MI says was caused by the leak Given MI’s evidence, I a ccept the evidence shows the kitchen/laundry waste leak has caused damage. The damage caused by this has been identified by MI. Therefore, the applicant has shown a prima facie claim for this damage. I do not accept the evidence shows this event caused all of the damages being claimed. MI’s report is persuasive in showing that other movement and cracking damage is associated with issues such as the external drainage, a lack of brickwork articulation joints and permeable ground conditions. None of these factors fall within an insured event covered by the policy. Therefore, the applicant has not established a prima facie claim for this damage. As such, the FSP is to indemnify the applicant for the damage MI said was caused by the leaking pipe. In doing so, the FSP should arrange for a scope of works and quotations to repair this damage. If the FSP decides to cash settle the repairs, it should do so based on a quote available to the applicant. Case No: 519806 Determination Page 3 of 4 3 Supporting information 3.1 Expert reports Record Key points FSP’s expert (JJ) Report 20 - 09 - 2016  Cracking and movement became evident in the house approximately two years ago and this cracking and movement has been getting worse since.  The sub floor area noted a large amount of water evident underneat h the sub floor area which prevented access to the sub floor area.  The owner and tenant were not aware of any wat er underneath the house.  The plumbing report shows major problems are occurring wit h the storm water and the sewer pipes.  Breaks occur in the sewer pipe and probl ems with blockages in the storm water pipes occur.  This is resulting in the water occurring underneath the house.  Soil classified as highly reactive.  Seasonal changes in moisture content of the foundation material can cause up to 65mm movement at the surf ace of the soil .  The cracking and movement particularly of the plaster walls of the house is typical of problems that occur due to differential settlement of the concrete stumps and strip footings.  Differential settlement can occur due to seasonal changes in the moisture content of the foundation material.  Melbourne has experience a drought for a long period of time recently and also the last two summers have been very dry, summers without rain.  These seasonal changes in the moisture content of the found ation material can result in differential settlement occurring of the footings.  Normally a sub floor area is dry. In this case problems are occurring with both the sewer and storm water pipes to the property which is resulting in water occurring underneath the house.  This can result in extremes occurring in the moisture cont ent of th e foundation material. FSP’s expert (ALD) Report 13 - 09 - 2016  Rain at time of test.  CCTV inspection of stormwater line found that along south side of house pipe was full of roots to where blockage was identified below the hot water unit.  Below gravel drivew ay at southeast corner the pipe was cracked.  Prior to inspection of the plumbing, pool of water found in sub floor access door.  Inspection of subfloor found that where kitchen and laundry waste line are connected, and penetrate through brick wall below kit chen, this is broken causing water to pool in subfloor.  No drainage applied external to nort h side entrance. Case No: 519806 Determination Page 4 of 4 FSP’s expert (MI) Report 08 - 05 - 2018  No significant trees were observed near the subject property.  Class H – Highly reactive clays.  The lea k to the waste drain was repaired approximately 12 months ago.  Crack damages have typically occurred at locations of stress concentrations such as corners of openings.  The external ground around the house is not graded away from the building.  No externa l surface wat er runoff drainage provisions were observed.  The sub - floor soil surface was dry.  Crack damages observed at the subject property is due to underlying foundation movements caused from abnormal ground moisture content conditions.  Highly reacti ve clay soils upon which the house footings are founded upon is continuously changing in volume depending upon the soils moisture content.  An increase in moisture content causes the clay soils to swell resulting in an upward force on the footings known as “heave”, whilst a decrease in moisture content causes the clay soils to shrink resulting in settlement.  The kitchen/laundry waste drain leak will have caused an increase in soil moisture content in the vicinity of the leak location to the rear of the house . Consistent with the largest external wall crack observed to the rear wall below the kitchen window.  The drain leak alone does not explain the cracking damages occurring throughout the entire house including the front elevation, which is the wall furthest away from the leak location.  The lack of external drainage to the building perimeter explains the appearance of cracking damages throughout the house.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.