Home / Financial Firm (Unknown - Insurer) / Determination 519734
Determination 519734
Storm damage claim declined; door binding and sinking floor attributed to long-term stump deterioration
Summary
The applicant claimed storm damage to her home after flooding; the FSP declined the claim. AFCA accepted the expert evidence that the damage was caused by long-term stump deterioration, so the FSP was entitled to decline. The FSP's earlier apology for service issues was considered appropriate; AFCA ordered nothing.
The applicant did not discharge her onus to show the proximate cause of the loss was an insured storm event, and the expert evidence was unchallenged.
Subjects and remedies
home or building damagenatural disasterno remedy
Text of the determination
Determination
Case No: 519734 Determination Page 1 of 5
Case number: 519734 18 June 2018
1 Overview
1.1 Dispute
The applicant holds a home and contents policy underwritten by the financial
services provider (FSP) covering her home address.
On 4 December 2017, a claim was lodged under the policy for damage to the
property which the applicant says occurred from heavy rains in the preceding days.
After considering the claim, the FSP declined it on the basis the loss had not arisen
as a result of any insured event covered by the policy.
1.2 Issues and key findings
Was the FSP entitled to decline the claim?
The FSP was entitled to decline the claim because:
the policy is a defined events policy, which only covers loss or damage from an
insured event;
the damage did not arise from an insured event;
the cause of the damage is specifically excluded from cover; and
the FSP was therefore entitled to decline the claim.
What is the appropriate remedy for the applicant’s service concerns ?
The FSP has provided a w ritten apology addressing the applicant‟s disappointment in
the level of service she received during the management of the claim. This is an
appropriate remedy in the circumstances.
1.3 Determination
This determination is in favour of the FSP.
The FSP was entitled to decline the claim and is not required to take any further
action.
Case No: 519734 Determination Page 2 of 5
2 Reasons for determination
2.1 Was the FSP entitled to decline the claim?
Applicant has the onus to establish a prima facie claim
It is established insurance law the applicant carries the initial onus to show that the
terms and conditions of the relevant insurance policy covers the loss. This is known
as a prima facie claim.
Once the applicant establishes a prima facie claim, the onus then shifts to the FSP to
demonstrate the loss is not covered, either by way of one of the policy exclusions or
on some other basis.
The FSP‟s policy is a defined events policy. Therefore, the policy only responds
where an incident caused by one or more of the listed events results in loss or
damage, subject to any exclusions. One of the listed events is storm.
Applicant says the damage arose because of a storm
The applicant says in the days preceding the loss, there had been heavy rainfall in
the area. There was widespread flooding in the streets and stormwater runoff was
observed to flow under the house.
The applicant says it was immediately after this occurred that the front entry door
began binding. She also says the downpipe which is missing fell off during this or
another storm, and therefore this is still storm damage and should be covered.
In order to bring her claim in under the policy terms, the applicant must show the
proximate cause of the loss is an insured event. That the damage was reportedly first
observed during or after a storm event is not enough, per se, to satisfy this onus.
Insufficient evidence that storm damaged the property
The FSP appointed engineering firm "HC" to inspect the property and comment on
the cause. Full details of H C‟s report are contained within section 3.2 of this
determination.
However, HC‟s report is clear in stating that there was little evidence of storm
damage to the property.
Rather, HC attributed the binding door due to the deterioration of the timber stumps
in the sub-floor, which is causing movement and sinking of the property. A
disconnected downpipe at the south wall was also allowing stormwater to discharge
directly onto the ground, which was further exacerbating the movement.
HC noted that timber stumps have a lifespan of approximately 40 years, with the
property in question being approximately 60 years old. HC considered the stumps
had reached the end of their serviceable life. Whilst HC accepted there had been
stormwater runoff to the sub-floor, he considered that had the stumps not already
been rotted, this would not have caused further movement.
Case No: 519734 Determination Page 3 of 5
I accept HC is suitably qualified and experienced to comment in this matter. In the
absence of any contradictory information, the FSP is entitled to rely on their findings.
As an aside, the original inspection by builders “PI” also considered the cause of the
damage to the property was long term ground movement.
Applicant has not presented any expert evidence
The applicant vehemently disagrees with HC‟s fi ndings and says the report was
inconsistent with the verbal comments made onsite. The applicant was invited to
provide information in support of her position that the property suffered storm
damage, such as a report from a suitably qualified person. Howeve r, she did not do
so. Accordingly, the FSP's evidence is unchallenged.
The applicant has also not presented any evidence showing the downpipe was
disconnected as a result of storm. Even if she did so, I am not persuaded this would
be anything other than a contributory cause of the loss.
No valid claim established
In the absence of conflicting information, I accept the FSP is entitled to rely on the
expert findings from HC and PI that the damage arose as a result of long term
movement at the property, rather than a storm or any other event which would be
covered by the policy.
There is no information presented showing if the property has ever been restumped.
Certainly, t he applicant has owned the property since the 1980‟ s and she does not
reference re-stumping the property in that time. Therefore, it is a reasonable
assumption to make that the stumps are original and have reached the end of their
serviceable life. On this basis , I accept HC‟s conclusions as to the cause of the loss.
Therefore, I do not accept the applicant has discharged the onus on her to establish
the policy responds to the loss. On this basis, the FSP was entitled to decline the
claim.
Other matters
The applicant has raised a number of concerns regarding the level of service she
received from the FSP throughout the life of her claim. In its letter of 16 March 2018,
the FSP acknowledges the applicant‟s concerns and accepts it did not respond in an
appropriate manner at all times. The FSP apologised for the level of service received
by the applicant and undertook to provide feedback and training to the staff involved.
In my view, this is an appropriate remedy in the circumstances.
Case No: 519734 Determination Page 4 of 5
3 Supporting information
3.1 FOS approach to this dispute
A full exchange of the relevant information has taken place between the respective
parties. Each party has had the opportunity of addressing any issues raised.
All of the provided material has been reviewed and considered. The parties have
raised numerous issues in their submissions to FOS. However, commentary in this
determination is restricted only to those issues considered relevant to the outcome.
The applicant is represented in this dispute. For the sake of brevity, refe rences to „the
applicant‟ will include her representative.
3.2 Expert evidence
Record Key points
FSP’s expert ( PI )
Builder‟s Report
19 December 2017
the insured advised after heavy rains, the front door became
hard to open and close
inspection found the front door out of alignment
the resultant damage has been caused by no end cap on the
spouting on the front veranda
this allows rainwater to pool on the ground causing differential
soil movement over a period of time
large trees close to the house have als o contributed to the
soil movement
the front corner of the house has sunk at the entry .
FSP’ s expert ( HC )
Engineer‟s Report
16 January 2018
the property is a weatherboard property constructed in the
1950‟s and has been owned by the applicant since the 1980‟s
the owner report ed the front door began jamming after
flooding of the street had occurred
water was observed to flow under the house during this event
there is also a roof leak above the kitchen, said to be from the
same event
the flooring on the so uth side of the entry is sinking and
cracking of the internal plaster walls has occurred
there was limited access to the sub - floor but access to the
north side of the residence was gained
the subfloor was in a dry condition
the timber stumps could not be checked, but the timber stump
below the south - east corner was visible and had some rotting
occurring to the external surfac e
there is a row of large trees adjacent to the porch area,
approximately 6 - 7 metres in height
geological surveys show the site is lo cated on quaternary
basaltic clay, which is a highly reactive clay soil
seasonal changes in the moisture can cause up to 65mm
Case No: 519734 Determination Page 5 of 5
movement at the surface of the soil
the cracking and movement occurring and sinking of the floor
is typical of problems arising fr om long term deterioration of
the timber stumps
deterioration of the stumps can be accelerated by excessive
moisture conditions in the sub - floor area
timber stumps have a life expectancy of approximately 40
years due to natural rotting and deterioration wh ich occurs
over the years due to normal moisture changes in the
foundation material
considering the age of the residence, the stumps are likely to
be in a deteriorat ed condition
the stumps are likely to be at the end of their serviceable life
and have been in a deteriorated condition for some time
the flooding which has reportedly allowed water entry to the
sub - floor can saturate the foundation material and reduce the
strength of the timber
this has resulted in furt her movement of the residence due to
the softening of the rotted timber
if the stumps were not rotted then this water entry event
would not have resulted in movement
the disconnected down pipe is allowing wat er to discharge
onto the ground at the south wall
this is contributing to the saturation of the timber stumps and
the movement and sinking of the flooring
tree roots have lifted the concrete path adjacent to the porch
the weathered edges of the pavement show this has been
occurring for some time and was not affected by the flooding
event
the s taining to the kitchen ceiling is because of a roof leak
the property requires restumping and relevelling of the floors
the disconnected downpipe should be reinstated to the eaves
gutter and reconnected to the storm water system
once the restumping is comp lete, the internal works to the
plaster can be undertaken.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.