Home / Financial Firm (Unknown - Insurer) / Determination 519662

Determination 519662

Claim declined under policy exclusions for storm damage to driveway and walls

FirmFinancial Firm (Unknown - Insurer)
Decided2018-08-14
ProductGeneral Insurance · Landlord
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed under their landlord property policy for cracked driveway slabs and a freestanding wall after a storm. The FSP declined on the basis of exclusions for settling, shrinkage, tree roots and gradual damage, and AFCA agreed.

The proximate cause of the loss was rotation, subsidence and poor construction rather than the storm, and the damage fell within policy exclusions.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 519662 Determination Page 1 of 4 Case number: 519662 14 August 2018 1 Overview 1.1 Dispute This matter involves a claim by the applicants under their Landlords Residential Property Insurance Policy, held with the financial services provider (FSP), following damage at the applicants‟ rental property. The FSP has denied the applicants‟ claim on the basis of exclusions within the policy. 1.2 Issues and key findings Is the FSP entitled to rely upon exclusions within the policy to deny the applicants’ claim ? The FSP is entitled to rely upon exclusions within the policy to deny the applicants‟ claim. 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny the applicants‟ claim. Case No: 519662 Determination Page 2 of 4 2 Reasons for determination This dispute has been the subject of a recommendation issued by the Service on 15 June 2018. It was the case analyst‟s recommendation that the FSP was entitled to deny the applicants‟ claim on the basis of exclusions within the policy. The applicant has disputed the recommendation. A copy of the recommendation is attached to the determination. I have carefully considered all of the material provided both before and after the recommendation in the preparation of this determination. This determination follows consideration of all of the information exchanged and is based on what is fair in the circumstances, having regard to the relevant legal principles, terms of the policy, good industry practice and where applicable, prior determinations. 2.1 Is the FSP entitled to rely upon exclusions within the policy to deny the claim? Coverage of the policy The coverage provided by the applicants‟ Landlords Residential Property Insurance Policy is detailed within the Policy Disclosure Statement (PDS). The policy provides coverage for the buildings and contents, for any accidental loss or damage. However, the coverage provided by the policy is subject to a number of exclusions which are detailed within the PDS. This means that not all loss and damage is automatically covered but rather only loss and damage which is not excluded under the provisions of the policy coverage. The FSP seeks to deny the applicants‟ claim on the basis of exclusions within the PDS and thus the FSP carries the onus to establish the application of an exclusion upon which it seeks to rely to deny the applicants‟ claim. Circumstances of the loss The applicants say that during the height of a fierce storm (October 2017), rainwater flowed from the rear of the property across the concrete driveway heading towards the front gutter drainage. Due to the volume of rainwater that fell at this particular moment in time, the water in the front gutter drain started to back up and come back into the property, rushing back down the driveway. The applicants say that when these two volumes of water met, it caused damage to the concrete driveway. Case No: 519662 Determination Page 3 of 4 Further, the applicants say that the huge volume of storm rainwater activity that occurred at the property that night, caused significant damage to the concrete driveway and in particular, caused the driveway to lift up and crack in various places. As a consequence, the applicants say that a boundary brick fence that was built on top of that part of the driveway, has also been damaged. The parties have provided opinions from consultant engineers to support their respective positions. The recommendation, which is attached to this determination, provides a summary of the opinions expressed by the parties ‟ consulting engineers. I am satisfied that the summary presented within the recommendation is accurate and sets out in a detailed fashion the views expressed by the consulting engineers. I also agree with the case analyst to the effect that to determine whether or not there is coverage under the policy, it is necessary to determine the proximate cause of the applicants‟ loss. As detailed by the case analyst the proximate cause of the loss is a question of fact to be determined by the circumstances of each case. It is also well established that the proximate cause is not necessarily the first or last or the sole cause of the loss, but rather, it is the effective or dominant or operative cause of the loss. Having reviewed all of the exchanged material, I am satisfied that it is significant that the consulting engineering engaged by the applicant has confirmed: „.. that over time these unsealed areas have allowed for the ingress of storm water which has flushed the fine material from the sandy loam sub-grade, hence forming voids in the sub-grade which in turn has allowed the slabs to settle and cause failure along the plane at the inner edge of these areas…‟ I also note that the consultant engaged by the FSP details: „ 3.1 Driveway Slab Cracking The cracking to the centre of the driveway panels is due to shrinkage cracking of the concrete. Shrinkage cracking occurs to concrete during the curing process of the concrete. Steel reinforcement is provided to control the appearance of the shrinkage cracks. The reinforcement is generally provided to the top of the concrete section between 30 to 40mm from the surface. The reinforcement observed is located to the bottom of the slab and as such has not been effective in preventing cracking from occurring. The placement of the reinforcement in this slab is considered to be very poor building pr actice. The large cracks below the free-standing masonry walls have been caused by the rotation of the masonry wall footing. As the footing and slab have been poured together, any rotation of one element will cause a rotation of the other. As the slab rota tes with the footing, a tensile stress is generated within the concrete. Due to the location and degraded nature of the streel reinforcement within the slab the concrete slab has not been able to withstand this tension load and has subsequently cracked. 3.2 Freestanding Masonry Walls The rotation of the masonry wall footing is due to a combination of rotation of the retaining wall below the freestanding wall footing and loss of support/subsidence under the footing due to break down of the tree roots and deleterious material. Degradation of the tree roots below the footing result in voids forming below the footing. When the void below large enough subsidence of the soil adjacent the void occurs and the supported footing will move down also. Case No: 519662 Determination Page 4 of 4 The subsidence and rotation of the retaining wall does not occur over a short period of time and the rotation would have occurred over a number of years and cannot be attributed to one event. The presence of mildew and dirt within the crack is also evidence the crack has been present for some time. It is possible due to water ingress a rapid settlement and subsidence of the soil below the footing has occurred and caused the cracks to worsen however the cracks would have been pre-existing in some form before the event. ‟ As detailed within the case analyst‟s recommendation, the policy coverage includes exclusions for settling, shrinkage, corrosion, gradual deterioration, depreciation, wear or tear, roots from trees, a defect in an item, structural defects or faulty workmanship or design. Significantly, there is also a general exclusion for any incident that does not occur within the period of insurance. Noting the reports from both consulting engineers, I am satisfied that the damage at the applicants‟ property occurred o ver time, likely outside the period of coverage and was a result of events excluded by the policy provisions as detailed within the reports of the consultant engineers. The result is that the FSP has established its entitlement to rely upon exclusions with in the policy to deny the applicants‟ claim. Recommendation Case No: 519662 Recommendation Page 1 of 7 Case number: 519662 15 June 2018 3 Overview 3.1 Dispute The applicants lodged a claim on 24 October 2017, after they noticed cracks appearing through the driveway and external walls. The financial service provider (FSP) engaged an expert to assess the damage, and subsequently declined the claim. The FSP says the damage was caused by factors excluded from cover, and the damage occurred prior to policy inception. The applicants dispute the decision to deny the claim, as they maintain damage was a result of a storm. 3.2 Issues and key findings Is the FSP entitled to decline the claim? The FSP was entitled to decline the claim because the damage arose from factors which are specifically excluded from cover. 3.3 Recommendation This recommendation is in favour of the FSP. The FSP is not required to take any further action. Case No: 519662 Recommendation Page 2 of 7 4 Reasons for recommendation 4.1 Is the FSP entitled to decline the claim? Applicants established a valid claim The applicants carry the initial onus to establish any loss or damage arising from an event covered by the terms and conditions of the policy. Only once this is established does the onus shift to the FSP to show, on the balance of probabilities, the loss claimed falls within an exclusion of the policy. The applicant s‟ policy provides cover to the building for accidental loss or damage. The policy defines “accidental damage”, as damage to loss or destruction of the buildings that make up your rental property, or your contents when it is caused by an unintentional act, or an unforeseen and uncontrollable incident. The onus is therefore on the applicant to establish the loss or damage to his property was accidental, that is, not intended or expected, and occurred during the period of cover, subject to any exclusions. As the policy is a landlord policy and the applicants do not live at the property. I am satisfied that damage to the property was unintentional, unforeseen and uncontrollable. Parties are divided by cause of damage The applicants claim a storm caused damage to their driveway, freestanding wall and retaining wall. They say the storm caused the damage due to the huge volume of water running from the rear of the property to the front gutter. The applicants state the water moves from the rear to the front of the property going underneath the driveway slab causing it to lift and crack. The applicants accept there were fine cracks prior to the event, but say due to the storm it has intensified the damages. The FSP engaged engineer NC to comment and review the damages. NC concluded damage to the slab and leaning of the freestanding wall was due to a combination of rotation of the retaining wall, subsidence of the fill due to break down of tree roots, and poor construction of the slab. NC states:  steel reinforcement in the crack is rusted and broken and placement of the reinforcement is poor building practice  over flowing of the eves gutters contributed to the lifting slab  rainfall between 16 th and 20 th October 2017 is not deemed to be an extreme  damage is due to shrinkage and cracking of the concrete  the location of the steel has not been able to withstand tension load and cracked  rotation of masonry wall footing has lost support due to the breakdown of tree roots and deleterious material Case No: 519662 Recommendation Page 3 of 7  subsidence and rotation of the retaining wall does not occur over a short period of time, rather a number of years, and unable to be attributed to one event. This is supported by the presence of mould and mildew growth observed within the cracks  it is possible water ingress, settlement and subsidence have caused the cracks to become worse In response to the report provided by NC, the applicants obtained their own engineer report from SM to challenge NC‟s findings. SM inspected the property and states:  some movement/displace of the slab is severe and consistent along the driveway at each setback of the slab  damage is not a result of intrusive roots  setback areas were used for planting some time ago  the sheared face of the slab indicates cracking is recent and occurred over a short time span  resultant cracking and displacement of the sections of the driveway slab are resultant of settlement caused by storm water run-off.  overtime unsealed areas allowed the water ingress to flush the material from sandy loam sub-grade, forming voids allowing the slab to settle causing failure along the plane at the inner edge of the area. FSP entitled to deny the claim In order to determine whether the applicants‟ claim falls within an insured event, it is necessary to determine the proximate cause of the loss. What is the proximate cause of the loss is a question of fact depending upon the circumstances of each case. It is well established that a proximate cause is not necessarily the first or last or the sole cause of the loss. It is the effective or dominant or operative cause of the loss. If there are several causes operating contemporaneously, then each must be examined for the qualities of predominance and efficiency as the active efficient cause that sets a relevant train of events in motion. Courts have said that if one cause would have resulted in the harm in any case and the other would not have done so in the absence of the first, then the first is the proximate cause. In this case, on balance the proximate cause of damage does not appear to be from the storm. Rather, the available material establishes the damage is a combination of rotation, subsidence and poor construction of the slab. I take this view as:  the applicants accept fine cracking was present prior to the storm and this is also supported by the applicants broker  information from the Bureau of Meteorology shows there was no event strong enough to cause the damages  SM‟s report confirms the proximate cause of damage was unsealed areas allowing water ingress to flush material from within the slab  SM‟s report confirms damage has occurred over time Case No: 519662 Recommendation Page 4 of 7  normal c onditions could cope with the storm in NC‟s report  the applicants‟ property was inspected seven days after claim lodgment and showed signs of mould and mildew within the cracks. While I accept the applicants‟ perspective, and am satisfied the damage was unforeseen, on balance, damage is caused by factors excluded under the policy. For this reason, the FSP is entitled to deny the applicants‟ claim. Case No: 519662 Recommendation Page 5 of 7 5 Supporting information 5.1 Other matters considered which did not change the outcome The FSP has raised concerns that damage predates policy inception. It is not necessary to consider this issue in detail as it will not affect the outcome of this recommendation. 5.2 Policy wording Exclusions to your cover Any cover we provide is subject to the following exclusions. Accidental damage cover, additional cover and optional cover exclusions - settling, shrinkage or any movement of earth - erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear - roots from trees, plants, shrubs or grass - a defect in an item, structural defects, or faulty workmanship or design […] General exclusions We will not cover any loss or damage, or liability as a result of, or arising from: - any incident that does not occur within your period of insurance 5.3 Key Reports Record Key points FSP’s expert ( NC ) Report 22 - 11 - 17 „ Cracking to the drive way was observed in all panels of the driveway. The cracks were generally located at the mid points of the slab to the full width of the slab‟ Large cracks were located to the slab in front of the block walls supporting the clothesline. The largest of the cracks is 16mm wide and a step of 25mm over the crack.‟ „ All of the cracks observed do not appear fresh and mould and mildew growth was observed within the crack s . ‟ „ The steel reinforcement of the driveway was obs erved in the crack and is located at the bottom of the slab section. The reinforcement was ob served to be rusted and brok en.‟ The damage to the drive way is reported to have occurred due to overflowing of the eaves gutters of the Unit development and has caused the slab to lift. „ This return period is relatively low and it is expected and accepted that the gutter will overflow regularly and would have done so during many previous rain events during the li fe of the development. ‟ Under normal conditions, the driveway is expected to be able to handle the rainfall from half of the roof area of the unit structure, as the down pipe at the rear LHS of the units discharges directly on the Case No: 519662 Recommendation Page 6 of 7 driveway sl ab‟ „ The condi tions experienced during the rainfall event which occurred between the 1 6 and 20 October, 2017 is not unexpected or deemed to be an extreme event. As can be seen in the Statistics for the Towns ville Aero Station, the Mean Daily Rainfall for October is 23.4 mm. ‟ „ Garden beds which have had the veget ation removed are located between each of the masonry walls. Large stumps are visible within the garden bed areas an d also behind the masonry walls.‟ „ The damage to the slab and leaning of the freestanding wall is due to a combination of rot ation of the small retaining wall, subsidence of the fill due to break down of tree roots and poor construction of the slab. ‟ „The rotation of the mas onry wall footing is due to a combination of rotation of the retaining wall be low the freestanding wall footing and loss of support subsidence under the footing due to break down of the tree roots and deleterious material.‟ „Degradation of the tree roots below the footing result in voids forming below the footing. When the void belo w large enough subsidence of the soil adjacent the void occurs and the supported footing will move down also.‟ „The subsidence and rotation of the retaining wall does not occur over a short period of time and the rotation would have occurred over a number of years and cannot be attribut ed to one event. The pres ence of mildew and dirt within the crack is also evidence the crack has been present for some time.‟ „It is possible due to water ingress a rapid settlement and subsidence of the soil below the footi ng has occurred and caused the cracks to wors en however the cracks would have been pre - existing in some form before the event.‟ Applicant’s expert (SM ) Report 28 - 5 - 18 As per the attached photographs, it can be seen that the driveway slab has cracked sever ely in the section bet ween the former planting areas. Some of the movement/ displacement of the slabs is quite severe and in consistent along the driveway at each set back of the slab. There is evidence that at some stage in the past that the set - back area s were used for planting, however this appears to have been some significant time ago judging by the plant stumps remaining in the ground. From the widt h of the cracks in the driveway slab as well as the vertical displacement, in the authors opinion, the r esultant damage is not result ant from intrusive vegetation roots. The sheared face of the slab indicates that the cracking has been recent and occurred over a short time span for all set - back slabs. The cracking and slab levels seem to suggest that the pro blem lies in settlement of the slab edge given the mass of masonry wall to the perimet er of each of these features. „As the driveway slab is not connected to the neighbouring retaining wall, there is significant o pening at the junction of the slab and this wall as well as he former planting strips I would propose that over time these unsealed areas have allowed for the ingress of stormwater which has flushed the fine material from the sandy loam sub - grade, Case No: 519662 Recommendation Page 7 of 7 hence forming voids in the sub - grade which in turn has allowed the slabs to settle and cause failure along the plane at the inner edge of these areas.‟ „In summary, it is my opinion that the resultant cracking and is placement of these sections of the driveway slab are resultant of settlement caused by ing ress of stormwater run - off.‟

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.