Home / Financial Firm (Unknown - Insurer) / Determination 514600

Determination 514600

Roof repair claim after Cyclone Debbie denied under wear and tear exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2018-05-02
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's claim for roof repairs after Cyclone Debbie was denied by the insurer. AFCA found the roof damage was mainly gradual wear and tear and awarded no compensation for non-financial loss.

The wear and tear exclusion applied because gradual deterioration was the dominant cause of water entry, and the faulty workmanship exclusion could not be established.

Issues

Subjects and remedies

natural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 514600 Determination Page 1 of 4 Case number: 514600 2 May 2018 1 Overview 1.1 Dispute The applicant holds building and contents insurance with the financial services provider (FSP) to insure his home against certain insured events (such as storm and impact) and accidental damage. During Cyclone Debbie, the applicant says a tree limb fell onto his flat patio roof causing it, and an internal supporting beam, to bow. The FSP’s contractor propped up the roof from the underside as a make-safe measure, but the applicant says this made the situation worse, causing more water damage to the interior. The FSP initially denied the applicant’s claim for roof repairs on the basis of a general exclusion for defective or faulty workmanship. The FSP has since also relied upon an additional general exclusion for wear and tear. The applicant wants the roof repaired and compensation for non-financial loss. 1.2 Issues and key findings Has the FSP fulfilled its policy obligations? The FSP has fulfilled its policy obligations because:  the make-safe measures taken were reasonable  it is not entitled to rely upon the faulty workmanship exclusion to deny the claim  it is entitled to rely upon the wear and tear exclusion to deny the claim  as the claim is properly denied, no claim can be made for resultant damage. Is the applicant entitled to compensation for non-financial loss? No compensation for non-financial loss is warranted. 1.3 Determination This determination is in favour of the FSP. The FSP is not required to repair the roof nor pay any compensation to the applicant. Case No: 514600 Determination Page 2 of 4 2 Reasons for determination 2.1 Has the FSP fulfilled its policy obligations? At the rear of the applicant’s house, there is a n elevated patio measuring about 5.6m x 4.8m enclosed by a flat roof. Rainwater drains onto the flat patio roof from two sides where it meets the pitched roof of the house at its fascia. The patio roof is constructed from cold room panels, which are 50mm thick sheets of polystyrene sandwiched between two metal layers. The exposed top of the panels have a black tar material applied as waterproofing, as well as silicone in certain areas. Because the roof has pitch of between 1 to 3 degrees, there are spots where the water pools on top. Internally, the panels are supported by a 100mm x 100mm timber beam spanning 4.2m. Both the internal linings and the supporting beam have bowed towards the centre of the patio. Despite the applicant’s best efforts, it is evident that water has penetrated the panels to enter the room. Photographs of the light fittings show evidence of water stains. At the ceiling’s lowest sagged point (where the water collects), the applicant has inserted a 20mm plumbing conduit into the ceiling panel as an unconventional drainage system, which runs along the suppor ting beam and diverts water outside. The make-safe measures taken were reasonable After Cyclone Debbie, the FSP arranged for its contractor to undertake make-safe measures. The FSP’s contractor installed a vertical pine stud to support the sagging ceiling as a precautionary safety measure to minimise the danger of failure, but did not place this on the supporting 4.2m beam. The applicant says by placing the vertical support elsewhere on the ceiling, this changed where the water pooled which could no longer exit through the 20mm plumbing conduit as he had intended. The result was that water entered at other points in the patio ceiling. The applicant is also critical of the FSP’s delay in attending to repairs, failure to apply silicone and made no effort to stop water from entering. Make-safe arrangements are not permanent repairs. They are intended only to prevent further damage and injury and make the area safe. A decision to undertake make-safe measures is a separate consideration to whether the claim would be accepted. It appears that the FSP’s contractor’s immediate concern when attending to make-safe the patio was to ensure that it did not collapse under the weight of pooling water. The applicant lodged the claim with the FSP on 19 April 2017, and the FSP’ s loss adjuster first inspected the property five days later. This is not an unreasonable timeframe to respond. Because it was apparent that the ceiling had been sagging for some time, the FSP considered the need for immediate make-safe measures. Ultimately, on 17 May 2017, the FSP engaged a contractor to secure the ceiling out of an abundance of caution. The time and manner in which the FSP took make-safe measures is reasonable in the current circumstances. Case No: 514600 Determination Page 3 of 4 The FSP cannot rely upon the faulty workmanship exclusion to deny the claim There has been some discussion between the parties about whether the supporting beam and cold room panels were appropriate building materials for a roof. The FSP says it is clearly not a desirable material for this type of construction. The applicant has produced council certification of the construction dated 21 May 2008, although such certification was of the frame and excluded the roof. In any event, the FSP appears to concede that even if the construction was passed by the relevant council certification in 2008, it was not appropriate for today’s standards. In order to rely upon the faulty workmanship exclusion in the policy to deny the applicant’s claim, the FSP must show an inherent or built-in defect or defective or faulty workmanship, design or manufacture. This exclusion must be considered in light of the building standards in place at the time of construction. Although the FSP has produced no evidence of current building standards, it is not appropriate to apply today’s requ irements to a build that was some ten years ago. On this basis, the FSP has not established the faulty workmanship exclusion to deny the claim. The FSP is entitled to rely upon the wear and tear exclusion to deny the claim. It is necessary to determine the proximate cause of the damage; that is, what caused damage to the patio roof which led to water entry? The proximate cause of the damage is the dominant, effective or operative cause of the damage whether or not it was the last in time or the sole cause. The applicant says that the tree limb caused damage to the patio roof during Cyclone Debbie, impacting the roof and causing it to bow. The FSP says that regardless of whether the damage was caused by storm, impact, or accident, a general exclusion for wear and tear through normal use applies to deny the claim. The FSP’ s engineer inspected and reported on the patio roof. He commented about the likelihood of foot traffic on the roof, which the applicant denies. I do not accept that foot traffic (if any) caused damage to the roof. The FSP’s engineer said it was likely the impact of the tree branch on the roof has exacerbated some of the sagging of the roof beam and the roof sheeting at the point of impact. The applicant says the tree branch caused the roof to be penetrated, allowing water to enter. I do not consider the tree branch impact to be the proximate cause of damage. This is because the roof was already affected by water penetration before the tree branch hit. Although the applicant denies the beam was sagging under the weight of water before the tree branch impacted, there is evidence of water ingress over a prolonged period of time. The applicant concedes that he had installed the beam and the ceiling conduit drain some years before Cyclone Debbie (when he had flashing professionally installed). It is evident by installing a 20mm plumbing conduit to drain away pooling water from the ceiling panels that water had been penetrating the roof for some time. I accept that the dominant cause of the damage to the roof which allowed water entry was gradual deterioration or wear and tear. On this basis, the FSP is entitled to rely upon the wear and tear exclusion to deny the applicant’s claim for roof repairs. Case No: 514600 Determination Page 4 of 4 No claim can be made for resultant damage The applicant says he was willing to bear the cost of, and makes no claim against the FSP for, damaged carpet, lounge, and plaster walls as they were second -hand or readily replaceable. However, he says that the lacquered floors within the house are patchy and lifting because water from the patio has been tracked throughout the house over the last year. As the FSP is entitled to deny the applicant’s claim for roof repairs, no claim can be made for resultant damage. 2.2 Is the applicant entitled to compensation for non-financial loss? No compensation for non-financial loss is warranted While we have the power to award compensation for non-financial loss for stress, inconvenience, anxiety and disappointment arising from delay and poor service, it is only in limited circumstances that compensation is considered for non-financial loss and awards are unlikely to be substantial. The FSP engaged a loss adjuster, contractor, builder and engineer to attend the applicant’s property over the course of four months. The applicant says that one of them was vocal about what he thought of the roofing material and its suitability. Cyclone Debbie was a major weather event which resulted in many insurance claims. In this context, the time and manner taken i n considering the applicant’s claim is not unusual. We expect applicants to be moderately robust in the way in which they deal with a problem and to bear the ordinary and normal degree of inconvenience associated with an insurance claim. While the applican t’s customer experience has not been to his expectations, the time taken to process to the claim and the manner which the claim was processed does not warrant compensation for non-financial loss.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.