The applicant's home suffered rain ingress through rusted, non-compliant box gutters and the FSP denied the claim. AFCA found the damage was caused by faulty workmanship and an opening not created by a storm, both excluded, so nothing is payable.

The exclusions for faulty workmanship and design apply regardless of whether the insured knew of the defect, and section 46 of the Insurance Contracts Act does not assist.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 511594 Determination Page 1 of 4 Case number: 511594 27 June 2018 1 Overview 1.1 Dispute The applicant lodged a claim under his home buildings policy with the financial services provider (FSP) after damage occurred when rainwater entered his home in September and November 2017. The claims were assessed by the FSP and liability was denied. The FSP considered the cause of the damage to be a result of corrosion to the box guttering. The corrosion occurred due to the incorrect installation of the box guttering which enabled water to pool in the gutter. This cause of damages is excluded from cover. The case analyst provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the FSP. A copy of the recommendation is attached to this determination. As the applicant did not accept the recommendation, the dispute has been referred to me for determination. 1.2 Issues and key findings Were the findings of the recommendation correct? The findings contained in the recommendation were correct and are adopted in this determination. No further submissions were made or new material provided after the recommendation which affected the outcome. Is the FSP entitled to deny the applicant’s cla im? As the material provided establishes on the balance of probabilities the cause of the damage is excluded under the policy, the FSP is entitled to deny the applicant’s claim. 1.3 Determination This determination is in favour of the FSP. I agree with the ca se analyst’s reasons for the recommendation and the recommended outcome. The FSP is entitled to deny the claim. The FSP is not required to take any further action in relation to the claim or the dispute. Case No: 511594 Determination Page 2 of 4 2 Reasons for determination 2.1 Were the findings in the recommendation correct? The findings in the recommendation were correct I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied the documentation I have relied on has been provided to both parties. I am satisfied the case analyst’s recommendation contains an accurate summary of the dispute, the issues to be determined, any applicable paragraphs of the Terms of Reference and any relevant law. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. No new material provided after the recommendation The recommendation was rejected by the applicant. No further submissions or new information was provided. Therefore, there is no further material after the recommendation which affects the outcome or advances the applicant’s case. 2.2 Is the FSP entitled to deny the applicant’s claim? It is not in dispute rain ingress caused internal damage There is no dispute rainwater has entered the applicant’s home causin g internal water damage. The applicant says he has accidental damage cover, so his policy should respond. Rain entered the home because of holes in rusted gutters A make safe was arranged by the FSP after the first claim was lodged. The report noted the box gutter above the internal damage was rusted. The repairer noted large holes in the base. He said water penetrated the roof cavity via the rusty box gutter. The FSP provided expert reports about the cause of damage in both claims. Photographs show the box gutters were significantly rusted. Above both areas of damage, the box gutter was installed in such a way that water pooled to the opposite end of where the rain head was installed. This was described as an installation fault. Further, the box gutters did not comply with relevant standards/codes as the gutters had no gradient which enabled the water to pond and create the rust in the gutters. The FSP submits because the box gutters were installed in a non-compliant manner, this caused water to pool and overtime caused rusting. Case No: 511594 Determination Page 3 of 4 The applicant agrees the guttering was not compliant. Since the claims, he has paid to have the gutters rectified. However, the applicant submits his claim should be met as he says he could not have been aware of the cause of the water ingress into his home. The applicant also argues about the applicability of the codes/standards relied on by the FSP’s experts and says if the gutters were non-compliant then an occupancy permit would not have been provided. Not all damage is automatically covered The cover provided by the applicant’s home insurance policy is in respect to loss or damage caused by an insured event, such as storm. The policy also includes accidental loss or damage. The policy defines accident as; A single occurrence or series of occurrences arising from one event which you did not intend or expect to happen. All cover is subject to the conditions and exclusions set out in the policy. This means not all loss and damage is automatically covered. FSP has established relevant policy exclusions apply to defeat the claim The FSP say the exclusions of faulty workmanship and gradual deterioration apply to the cause of the damage. The FSP also argues it is not liable to cover loss or damage caused by rain due to an opening which was not created by the storm. Having reviewed the exchanged material, I am satisfied the FSP’s reports establish the box gutters were not installed to the relevant building code/standards. I am satisfied the available material establishes had the box guttering been installed correctly, the damage would not have occurred. The corrosion has been appropriately identified due to the pooling of water over time, where eventually rainwater flows into the home. Further, the damage was caused by rain entering the home through an opening not created by the storm. Despite the obvious rust damage, even if the applicant was not aware of the cause of the water ingress into his home, this is not determinative of the outcome. I am also satisfied section 46 of the Insurance Contracts Act provides no relief to the applicant if he was not aware of that cause of the damage. This is because the remedial section only operates to assist an insured where the insurer relies on a policy exclusion which expressly refers to the defect having been present before the policy commenced. The exclusions relied on by the FSP do not refer to the defect existing prior to the insurance contract commencing. Having reviewed the available material, I am satisfied the standards/codes relied on by the FSP’s experts were applicable at the time the home was built. Further, I do not accept the applicant’s contention that if the gutters were non - compliant then an occupancy permit would not have been provided. This is because Case No: 511594 Determination Page 4 of 4 the occupancy permit is not evidence that the building or part of the building complies with relevant legislation. In any event, the material provided clearly establishes the damage was caused by rain entering through an opening which was not created by the storm. Upon review of the material provided I am satisfied the exclusions relied on by the FSP in relation to the cause of damage are correct. In the circumstances, on the information provided, and for the reasons stated, I am satisfied the FSP is entitled to rely on the policy exclusions to deny the applicant’s claim. Recommendation Case No: 511594 Recommendation Page 1 of 5 Case number: 511594 5 April 2018 3 Overview 3.1 Dispute The applicant holds a home and contents insurance policy with the financial services provider (FSP). The applicant lodged a claim on 5 September 2017 for damage sustained to the property as a result of a storm. The FSP declined the claim because it says damage was caused by faulty design of the guttering, which is specifically excluded under the policy. The applicant disputes this and is seeking the FSP pays for the cost of repairs to the property. 3.2 Issues and key findings Has the applicant established an entitlement to cover? Based on the available information, I consider the applicant’s property sustained damage caused by the escape of rainwater. As this event is covered under the policy, the applicant has established a claimable loss. Is the FSP entitled to apply any policy exclusions? The FSP is entitled to decline the claim for damage to the applicant’s property. This is because the proximate cause of the damage was the faulty design of the property’s guttering. 3.3 Recommendation This recommendation is i n favour of the FSP. The FSP is not required to take any further action. Case No: 511594 Recommendation Page 2 of 5 4 Reasons for recommendation 4.1 Has the applicant established an entitlement to cover? Applicant’s duty to establish prima facie claim The applicant is required to show, on the balance of probabilities, he suffered a loss caused by an event insured for under the policy. This is known as a valid ( prima facie ) claim. If established, the onus shifts to the FSP who must show, on the balance of probabilities:  the policy does not cover the loss or damage, or  the FSP is otherwise entitled to deny the claim. Policy covers storm and rainwater damage and accidental damage The applicant’s policy provides cover for a series of insured events plus optional cover for accidental damage. The certificate of insurance (COI) confirms the applicant took out the accidental damage cover. Under the insured event ‘storm and rainwater’ the policy covers loss or damage from the escape of rainwater from any water pipe, drain or gutter. Under accidental damage, the policy covers accidental loss or damage to the property caused by an accident which occurs at the insured address. The policy defines accident as: a single occurrence or series of occurrences arising from one event which you did not intend or expect to happen. The cause of loss was escape of rainwater The applicant lodged a claim on 5 September 2017 for damage to the living and dining room of the property following a storm. The applicant lodged a second claim after noticing similar damage to bedroom three o n 18 November 2017. Bureau of Meteorology data for the vicinity of the applicant’s property shows below average rainfall in September 2017. On 5 September 2017 0.4mm was recorded, with a further 5.8mm on 6 September 2017. On 18 November 2017 0.4mm was recorded, and a further 9.6 on 19 November 2017. Given the above rainfall, I do not consider the circumstances are consistent with a storm event. However, I accept they are consistent with the escape of rainwater. The FSP has provided the initial claim note: The roof and ceiling are leaking due to the rain as well as the down lights. The FSP appointed an assessor (JM) to inspect the damage. JM attended the applicant’s premises on 8 September 2017. He found:  damage to living and dining room ceiling, walls, bay view windows and timber parquetry Case No: 511594 Recommendation Page 3 of 5  water ingress came from box gutter above bay view window  box gutter had no gradient fall and was rusted  water was pooling in same area since time of construction. Following lodgement of the second claim, the FSP appointed a nother assessor (AH) to review the damage. AH found:  water ingress occurred to bedroom 3 which is located below a box gutter  damage to bulk head lining, architraves, ceiling and wall lining  box gutter was pooling water away from rain head  the fall was running the opposite direction to the storm exit  box gutter was rusted due to pooling of water over time and requires replacing  silicon had been applied to box gutter in the past. On balance, I accept the applicant has established a prima facie claim consistent with loss or damage caused by the escape of rainwater. 4.2 Is the FSP entitled to apply any policy exclusions? Policy excludes cover for some kinds of damage The product disclosure statement (PDS) outlines the circumstances in which the policy excludes cover. Relevant to this dispute, under the insured event for storm and rainwater the policy does not cover loss or damage caused by rainwater due to a design fault, structural defect or faulty workmanship. Under accidental damage, the policy says that exclusions applying to the insured events covered also apply to this cover. This means that the exclusions for design fault, structural defect or faulty workmanship also apply to accidental damage cover. As noted above, the FSP bears the onus to establish the exclusions apply. FSP has established exclusions apply The FSP says that the faulty design of the gutters, or faulty workmanship of their installation is the proximate (dominant or effective) cause of the observed damage. The FSP says that the gutters were installed with an insufficient fall meaning they do not comply with the relevant building code. This is supported by the reports provided by the assessors. Both JM and AH say that if the box gutter had been installed with the appropriate fall, water would not have pooled and the box gutter would not have deteriorated. This, in turn, means that the gutter would not have rusted or overflowed and water ingress into the living/dining room and bedroom three would not have occurred. As faulty design and faulty workmanship are explicitly excluded under both the storm and rainwater insured event and accidental damage cover, the FSP says it is entitled to decline the claim. Case No: 511594 Recommendation Page 4 of 5 The applicant disputes this and says that to his knowledge the gutters were compliant. He has provided a copy of the occupancy permit issued when the property was completed in August 2002. The applicant does not dispute that the gutters do not have the necessary fall, but rather that he didn’t know about the issue. Given he receiv ed an occupancy permit he believed the gutters were complaint and serviceable. As such, the applicant says the FSP should accept the claim. While I empathise with the applicant and the damage sustained to his property, I do not accept that his lack of knowledge regarding the faulty design of the gutter creates an obligation on the FSP to settle the claim. This is because the exclusion relied upon by the FSP does not say the applicant needed to know about the issue, but merely that the issue of faulty design or workmanship exists. I am ultimately satisfied the FSP has correctly applied the relevant policy exclusions. As such, the FSP is entitled to decline the claim. Case No: 511594 Recommendation Page 5 of 5 5 Supporting information 5.1 FOS approach There has been a full exchange of the relevant material between the parties and each party has had the opportunity to address the issues raised. I have reviewed and considered all the material provided by the parties. While the parties have raised various issues in their submissions, for the purposes of this recommendation, I have restricted its commentary to those issues which I consider directly relevant to the outcome only. 5.2 Relevant policy sections Insured event We will not cover Storm and rainwater Including loss or damage from:  the escape of rainwater from any water pipe, drain or gutter  surface run - off rainwater from surrounding areas that occurs within 24 hours of a storm or heavy rain.  Loss or damage caused by rain, hail, wind or dust due to: o a design fault, structural defect or faulty workmanship o l ack of maintenance (a defect that you knew about or should reasonably have known about and did not fix ) o an opening that was not created by the storm o building additions, renovation or alt eration work. Optional cover – Accidental damage When you elect to pay an additional premium and your insurance certific ate states you have cover for accidental damage we will cover:  accidental loss or damage to your home caused by an accident which occurs at the insured address, when your home is insured by this policy  accidental loss or damage to your contents caused by an accident which occurs in the home at the insured address, when your contents are insured by this policy. The exclusions applying to the insured events covered by this policy also apply to this option al cover, with the exception of the following: In respect of damage caused by fire, under this option we will cover:  loss or damage caus ed by scorching or melting when there was heat but no flame  loss or damage caus ed by smoke or soot when the home or co ntents have not been damaged by fire.