Home / Financial Firm (Unknown - Insurer) / Determination 509526

Determination 509526

Claim declined for stormwater damage to vergola due to structural defect and defective workmanship exclusions; handling delays

FirmFinancial Firm (Unknown - Insurer)
Decided2018-07-05
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$500
Amount claimed—
SourceAFCA PDF

Summary

The applicant's home insurer declined a claim for water damage to her vergola, citing exclusions for defective workmanship and structural defect. AFCA upheld the decline but found excessive delays and slow handling of safety concerns and ordered $500 for non-financial loss.

The proximate cause of the damage was incorrect flashing installation, which falls within the structural defect and defective workmanship exclusions, while the delays caused considerable inconvenience warranting compensation.

Issues

Subjects and remedies

home or building damagepay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 509526 Determination Page 1 of 4 Case number: 509526 26 June 2018 1 Overview 1.1 Dispute The applicant says stormwater ingress damaged the rear patio extension (vergola) of her property. She lodged a claim under her home insurance policy with the financial services provider (FSP). The FSP declined the claim. It originally said damage was a result of wear and tear, deterioration, rot and inherent defect. The applicant disputed the FSP’s decision. She is also dissatisfied with how the FSP handled her claim. The case officer issued a recommendation in favour of the applicant. The FSP did not accept that, and made further submissions, maintaining that the damage was from gradual deterioration caused by a structural defect and defective workmanship. 1.2 Issues and key findings Was the FSP entitled to decline claim? The policy covers ‘accidental damage’ and damage from ‘storm, rain or flood’ and ‘water or other liquid’ . However, the evidence shows the incorrect installation of the flashing allowed water to leak into the vergola over time, causing the damage. Damage caused by a ‘structural defect’ or ‘defective workmanship’ is excluded, and so the FSP has established, on balance, that exclusions apply which allow it to decline the claim. Is the applicant entitled to compensation for non-financial loss? The applicant is entitled to compensation for the FSP’s handling of the claim, since :  the FSP could have identified the cause of the damage earlier by conducting an investigation as recommended by its builder  the FSP did not promptly address safety concerns about the vergola. This has meant an unusual amount of time was taken to deal with the claim, which has in turn caused the applicant considerable inconvenience and concern. 1.3 Determination This determination is substantially in favour of the FSP. It is required to pay the applicant $500 compensation for non-financial loss; but is not required to take any other action. Case No: 509526 Determination Page 2 of 4 2 Reasons for determination I have decided this case on the basis of what I consider fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. For the purposes of this determination, I will deal with only those points considered relevant. 2.1 Was the FSP entitled to decline the claim? The applicant has established a valid claim under the terms of the policy The applicant is required to show, on the balance of probabilities, the damage was caused by an event insured against under the policy. This is known as a prima facie claim. The applicant’s policy provides cover for certain specific insured events, including ‘storm, rain or flood’ and ‘water or other liquid’ . Accidental loss and damage is also covered. The policy defines ‘ accidental ’ as ‘ unintended and unexpected ’. There is no dispute the applicant did not intend or expect the vergola damage. The evidence also indicates the damage was from water, in all likelihood from storm or rainwater entry. I am satisfied the applicant has established a prima facie claim. FSP must show the proximate cause of the vergola damage is excluded In order to be entitled to deny the claim, the FSP must show the proximate cause of the damage is excluded. The proximate cause is the dominant, efficient or operative cause of the damage. However, it is not required to be the sole cause or the last in time. The identification of the proximate cause is a question of fact that depends on the circumstances of each particular case. The courts have said that if one cause would have resulted in the harm in any case, and the other would not have done so in the absence of the first, then the first is the proximate cause. Incorrect installation of flashing caused the vergola damage Both parties engaged experts to assess and determine the cause of the vergola damage. The FSP’s engineer (IE) sai d the distortion of the vergola’s boxed beam was due to long term wet rot damage. However, IE concluded it was the inadequate support of the Colorbond sheet metal flashing that ultimately allowed water to enter through the flashing joints. Case No: 509526 Determination Page 3 of 4 The applicant’s builder also confirm ed his view that it is likely a slow leak from the flashing over a long period of time allowed water into the vergola. So while there has been a gradual deterioration of the timber frame and its fixings, the experts clearly identified that the flashing issue is what allowed the water to cause this damage. That means gradual deterioration (which does fall within the ‘general exclusions’ of the policy) was not itself the proximate cause: that deterioration would not have happened, had it not been for the incorrect installation of the flashing in the first place. The insured event of damage from ‘water or other liquid’ specifically excludes damage that is ‘the result of gradual processes’; and does not include cover to fix a defect in design or construction, or repair or replace defective parts. The insured event of damage from ‘storm, rain or flood’ excludes damage caused by ‘water penetrating or entering [the] building o r as a result of a design fault, structural defect or because of defective workmanship’. Cover for ‘accidental loss or damage’ is subject to an exclusion for events that are already otherwise excluded by another section of the policy. In this case, I am satisfied the proximate cause of the gradual vergola damage is the incorrect installation of the Colorbond flashings, which reasonably represents a structural defect or defective workmanship. That means the FSP has shown, on balance, tha t it is entitled to rely on the identified exclusions to decline the claim. 2.2 Is applicant entitled to compensation for non-financial loss? FOS considers an applicant needs to be moderately robust, and bear the normal degree of inconvenience experience to be reasonably expected when dealing with an insurance claim. However, we can award compensation for non-financial loss in circumstances where an error or the actions of the FSP has caused an applicant significant stress, inconvenience or upset. In this case, I consider there have been excessive and avoidable delays in the FSP’s handling of the matter. That includes a five month delay between the FSP’s builder recommending a ‘disruptive’ investigation of the vergola, and such an investigation being carried out. In the meantime, as well, the applicant expressed concerns about the safety of the vergola. However that was not acknowledged by the FSP until some months after it was first raised. I am satisfied the applicant has experienced considerable unnecessary inconvenience and concern because of the FSP’s handling of the claim. She is entitled to $500 as compensation for non-financial loss. Case No: 509526 Determination Page 4 of 4 3 Supporting information 3.1 Key reports Record Key points FSP’s builder (IB ) Site Report 30 - 03 - 2017  The observed damage does not appear consistent with a one off event. We suspect that water ingress has been occurring through the rear patio structure for some time, however disruptive investigations would be required to confirm. The addition of the vergola system to t he original patio structure may have cont ribut ed to the failure of the structure. This would be required to be confirmed by an engineer . FSP’s engineer ( BH ) Report 31 - 08 - 2107  From our observation within the boxed frame, we confirm the top of the boxed fra me has noggings and no plywood sheeting or other such substrate that would ot herwise provide adequate support of the sheet metal flashing. As such the sheet metal flas hing can pond wat er which can leak at joints. The lack of support to the flashing will al so place more stress upon all the joints increasing the risk of splitting sealant applied.  We are of the opinion the primary cause of water ingress to occur to the boxed beams was initially entering via joints in the Colorbond flashing, in particular over the vicinity of the north - western masonry column. Applicant’s builder (B A ) Report 16 - 02 - 2018  I would suspect that it was a slow leak over a long period. Probably coming from the flashing and dripping into the inside of the boxing.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.