Home / Financial Firm (Unknown - Insurer) / Determination 506205

Determination 506205

Shower leak damage claim denied as gradual deterioration and faulty workmanship

FirmFinancial Firm (Unknown - Insurer)
Decided2018-10-16
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$1,000
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for water damage from a shower leak, which the FSP denied as gradual deterioration and faulty construction. AFCA found the resulting damage covered and ordered a cash settlement of repair costs plus $1,000 for non-financial loss.

The faulty design and workmanship exclusion does not apply to resulting damage from an insured event where the insured could not reasonably have known of the defect.

Issues

Subjects and remedies

home or building damagepay claimpay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 506205 Determination Page 1 of 10 Case number: 506205 17 September 2018 1 Overview 1.1 Dispute The applicant lodged a claim under her home insurance with the financial services provider (FSP) after she noticed water leaking from her upstairs shower in March 2017. The FSP denied the applicant’s claim on the basis that the damage to the property was caused by factors which are excluded from cover under the policy (such as gradual deterioration and/or faulty workmanship). The applic ant disputes the FSP’s decision and seeks cover for the cost of repairing the damage to her property. 1.2 Issues and key findings Is the FSP liable for the applicant’s claim ? The FSP is not liable for the rotting damage to the timber support beam as this damage was caused by the beam being constructed out of timber which was not suitable for external use. The policy excludes cover for damage caused by structural defects or faulty design or workmanship. However, the policy provides cover for resulting damage (which would otherwise have been covered under the policy), in circumstances where the applicant could not reasonably have been aware of the defect. Based on the available information, the failure of the timber beam damaged the waterproofing of the en suite bathroom, causing water to leak into the sub-floor and porch ceiling. As the applicant could not reasonably have been aware of the defect in the timber beam, the FSP is liable for this damage. 1.3 Determination This determination is partly in favour of the applicant. The FSP and the applicant are required to work together to obtain a scope of works and quotation for the following repairs (from a contractor who is willing to carry out the repairs on the applicant’s behalf):  replacing the waterproofing to the shower recess (including all works required as part of that process), and Case No: 506205 Determination Page 2 of 10  repairing any damage to the timber sub-floor or the porch ceiling caused by the water leak. The FSP is required to cash settle the applicant for the amount of the quotation obtained (less any applicable excess). The FSP is required to pay the applicant an additional amount of $1,000 as compensation for non-financial loss. Case No: 506205 Determination Page 3 of 10 2 Reasons for determination 2.1 Is the FSP liable for the applicant’s claim ? Policy provides cover for accidental damage subject to exclusions The applicant is required to show that, on the balance of probabilities, she has suffered a loss caused by a risk insured against under the policy. This is known as a valid (or prima facie ) claim. If the applicant is able to establish a prima facie claim, then the onus shifts to the FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion under the policy to deny liability for the claim. The applicant’s policy schedule confirms she had elected to take out ‘accidental damage cover’. This option provides cover for damage to the property caused by any unintended and unforeseen incident, as well as damage caused by any of the insured events listed in the policy. The insured events include water leaking from a shower base. The cover is provided subject to the conditions and exclusions set out in the policy. The policy contains general exclusions for damage caused by:  wear, tear, gradual deterioration or any gradual process ,  settling, shrinkage or expansion in buildings, walls or foundations, and  structural defects or faulty workmanship or design. The exclusion for structural defects etc is subject to an exception which states that the FSP will pay for resultant damage that is directly caused by a n insured event, if the applicant could not reasonably have known about the relevant defect at the time the damage occurred. Applicant has established a prima facie claim for accidental damage The applicant lodged her claim after noticing water dripping from the timber ceiling of her front porch. The porch is located under the shower recess in the upstairs en suite bathroom. The reports provided by the various consultants who have inspected the property confirm that the shower is leaking and there is possible damage to the timber sub- floor (although the extent of this damage is unclear). There is also rotting damage to the main beam which supports the front porch roof and extends under the upper storey extension. On this basis, I am satisfied that the applicant has established a valid (or prima facie ) claim under the policy, given the broad scope of cover for accidental damage provided. In these circumstances, the FSP bears the onus of establishing that, on the balance of probabilities, it is able to rely on a policy exclusion or is otherwise entitled to deny the claim. Case No: 506205 Determination Page 4 of 10 In order to be entitled to deny the claim, the FSP must show that the proximate cause of the damage (that is the real, effective or dominant cause) is one or more of the factors outlined above which are excluded from cover under the policy. Current water leak is unrelated to previous claim In their submissions, both parties have referred to a previous claim by the applicant for water damage caused by a leak from the en suite bathroom. Howe ver, based on the information provided, I am satisfied that the current leak is unrelated to the previous claim. The earlier claim was lodged in November 2010 for damage to the bathroom wall and downstairs ceiling which had occurred in December 2009. The damage was caused by a burst pipe in the en suite bathroom. The applicant arranged for repairs to the pipe and the resulting damage to be completed before the claim was lodged. She provided photographs confirming the pipe had bene repaired. The FSP accepted the claim and cash settled the applicant based on an invoice for $6,667.27 provided by her repairer (CG). The FSP did not appoint its own consultants to carry out any investigations in relation to the claim. As outlined in more detail below, the c onsultants who have inspected the applicant’s property have identified several different factors which may be causing or contributing to the leak which is the subject of the current claim. However, there is no suggestion that the current leak has been caused by a broken pipe (or that the previous repairs were not carried out properly). Accordingly, I am satisfied that the applicant’s current claim is unrelated to the burst pipe discovered in December 2009. Consultants have provided conflicting reports about cause of damage As noted above, the various consultants who have inspected the property have provided conflicting views about the cause of the leak from the shower and the damage to the support beam. The applicant has suggested that the leak may have been caused by the faulty design of the upper storey extension (including the en suite) which was added to the property in or around 2003. It appears the applicant’s builder (CJ) advised that the upper storey extension had been constructed without adequate support and therefore had moved, causing the grout in the shower to crack. However, CJ has not provided a written report. The engineer (IF) initially appointed by the FSP to determine the cause of the damage observed that the main beam supporting the front porch was also subject to loading from the upper storey extension. IF advised that it was not possible to confirm whether or not the upper storey extension complied with applicable building standards without carrying out extensive, invasive investigations. Case No: 506205 Determination Page 5 of 10 The FSP did not carry out further investigations to determine whether the upper storey extension was non-compliant because IF considered that the damage had been caused by other, unrelated factors. In his report, IF noted several factors which may have contributed to the leak from the shower. However, he concluded that:  the leak had occurred due to the rupturing of the waterproof membrane as a result of distortion of the timber framework of the en suite caused by the bearing failure of the support beam, and  the failure of the support beam was caused deterioration of the timber, which had rotted over time. IF noted that the timber support beam was constructed out of Oregon timber, which has a low durability rating and requires regular painting to prevent decay. The applicant has separately advised that her builder considered this type of timber was unsuitable for external use. The FSP initially denied the applicant’s claim based on IF’s findings that the damage had been caused by gradual deterioration of the support beam (which is included from cover under the policy). However, after the applicant disputed the denial of her claim, the FSP appointed a second engineer (DC) to inspect the property. DC’s report was primarily aimed at identifying the caus e of the damage to the timber support beam. He concluded that the beam had deteriorated due to the effects of water entering the roof space over a prolonged period of time. DC advised that the water entry had been caused by the following factors:  leaks from the walls and floor of the shower recess due to inadequate water proofing, including large gaps and cracks in the grout and a gap between the floor waste and floor tiles  storm water entering through a broken roof tile next to the flashing above the porch, which directed water into the roof space during regular rainfall events, and  ongoing exposure to the elements over an extended period of time. In response to a subsequent enquiry from the FSP, DC advised that 50% of the damage to the support beam was attributable to water leaking from the shower, while the remaining 50% was attributable to rain water entering through the broken roof tile. Findings which are more favourable to applicant should be adopted The FSP’s engineers (IF and DC) have provided conflicting opinions about the proximate cause of the damage to the applicant’s property. IF concluded that the proximate cause of the damage was the rotting of the timber support beam due to the nature of the timber used, which was not capable of withstanding ongoing exposure to the elements. IF considered that the rot had resulted in the bearing failure of the beam which then damaged the shower, causing it to leak. He considered the leak was unlikely to have Case No: 506205 Determination Page 6 of 10 occurred first (thereby causing the beam to fail) because the rot had occurred at the bottom of the beam, where it rested on the timber support post. In contrast, DC considered that the leak from the shower (and the roof tile) had occurred first, exposing the top of the beam to water over a prolonged period of time, thereby causing it to rot. DC considered that both the escape of water from the shower and the water entry through the roof tiles had occurred due to gradual deterioration over time. I accept that both of the engineers appointed by the FSP are appropriately qualified to determine the cause of the damage. The reports provided by each engineer outline the reasons for their findings and include photographs which support their position. Nevertheless, IF and DC do not agree on the proximate cause of the damage. In these circumstances, it is appropriate to adopt the findings as to cause of damage which are more favourable to the applicant. FSP is liable for resulting damage to shower, sub-floor and porch As outlined above, the second engineer (DC) appointed by the FSP concluded that the damage to the applicant’s property was caused by gradual deterioration of the shower waterproofing and the roof tiles. If I were to accept DC’s findings, then the FSP would be entitled to deny the applicant’s claim in its entirety, as the policy excludes cover for damage caused by gradual deterioration (or any gradual process). However, the first engineer (IF) appointed by the FSP concluded that the damage had been caused by the use of incorrect timber for the support beam. If I were to adopt IF’s findings, then the FSP would not be liable for the rotting damage to the support beam, as this damage has been caused by faulty design or workmanship, which is excluded from cover under the policy. However, as outlined above, there is an exception to the exclusion for faulty design or workmanship. This exception provides cover for resulting damage (which would otherwise have been covered under the policy), in circumstances where the applicant could not reasonably have been aware of the defect. Based on the information provided, I am satisfied that the applicant could not reasonably have been aware that the wrong type of timber had been used to construct the support beam when the extension was built. Accordingly, she is entitled to cover under the policy for any resulting damage. On this basis, the FSP would be liable for the damage to the property resulting from the bearing failure of the support beam. This damage consists of:  the damage to the waterproofing of the sho wer recess, and  any damage to the timber sub-floor or the porch ceiling caused by the water leak. Case No: 506205 Determination Page 7 of 10 Applicant has not been prejudiced by lack of further investigations As outlined above, the applicant says that the damage to her property was caused by the faulty design and construction of the upper storey extension. The applicant has not provided a report from her builder (CJ) or any other independent information which establishes that the upper storey did not comply with applicable building standards. S he says the FSP should have undertaken further investigations to confirm this. However, even if the applicant’s position were to be accepted, the FSP would not be liable for rectifying any issues with the construction of the extension itself, due to the policy exclusion for structural defects and faulty design and workmanship. As noted above, the applicant has confirmed that her builder agrees with IF’s conclusions that the damage to the timber support beam was caused by the use of the incorrect timber. Accordingly, this damage would also be excluded from cover. While the applicant would be entitled to cover for resulting damage, this cover would only extend to the damage outlined above (being the damage to the shower recess, the timber sub-floor and porch ceiling). Accordingly, I am not satisfied that the applicant has been prejudiced by the FSP’s failure to carry out further, more extensive investigations regarding the upper storey extension. The applicant also says that the FSP failed to properly assess the 2010 claim. She says that, had the earlier claim been properly assessed, the issue with the support beam would have been identified and further damage could have been prevented. However, in circumstances where the applicant’s claim was lodged after th e damage had already been repaired, the FSP was not obliged to carry out its own assessment of the damage. Further, any such assessment would have been confined to the damage caused by the burst pipe and therefore would not have necessarily identified any other issues with the property. FSP is required to cash settle claim for resulting damage For the reasons outlined above, I consider the FSP is liable for the costs of:  replacing the waterproofing to the shower recess, which IF advised had been compromised due to the failure of the timber support beam (including all works required as part of that process), and  repairing any damage to the timber sub-floor or the porch ceiling caused by the water leak. However, the FSP is not liable for the costs of repairs to the timber support beam. These repairs need to be completed before the resulting damage can be addressed, in order to prevent ongoing issues. In these circumstances, it is appropriate that claim be cash settled for the cost of the repairs. Case No: 506205 Determination Page 8 of 10 Neither party has provided a quotation for the works required. Further, the scope of these works is currently unclear, as the extent of the damage to the timber sub -floor cannot be confirmed until the floor tiles and water proofing have been removed. Accordingly, the FSP and the applicant are required to work together to obtain a scope of works and quotation for the repairs set out above, from a contractor who is willing to carry out the works on behalf of the applicant. The FSP is required to cash settle the applicant for the amount of the quotation obtained (less any applicable policy excess). 2.2 Is the applicant entitled to compensation? Applicant is entitled to compensation of $1,000 FOS can award compensation (capped at $3,000) for non-financial loss where an applicant has suffered an unusual degree or extent of physical inconvenience, time taken to resolve the situation or interference with their expectation of enjoyment or peace of mind. In the present case, the conflicting reports provided by the FSP’s engine ers have contributed to the stress and inconvenience experienced by the applicant during the course of the claim. In the circumstances, I consider the applicant is entitled to compensation of $1,000 for non-financial loss. Case No: 506205 Determination Page 9 of 10 3 Supporting information 3.1 FOS approach to this dispute This dispute was the subject of a recommendation issued on behalf of the Financial Ombudsman Service (FOS) Australia on 9 March 2018. The recommendation was rejected by the FSP. This dispute has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions (which are not binding). There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any issues raised by the other. All of the material provided by the parties has been reviewed and considered (whether or not it is expressly referenced in this determination). 3.2 Terms of policy Subject Terms Cover for accidental damage If you have selected accidental damage cover: You are insured against accidental loss or damage to your home, contents or both at the site during the period of insurance. This includes cover for any of the Insured events. Accident – An incident that is unforeseen and unintended and that causes loss or damage. This includes a series of Accidents arising out of the one event. Insured event – escape of water You are insured against loss or damage caused at the site directly by the following Insured events: …  bursting, leaking, discharging or overflowing of fixed basins, shower bas es, or other fixed apparatus, fixed tanks or fix ed pipes used to hold or carry liquid of any kind … we do not pay for loss or damage:  which occurs a s a result of your failure to take reasonable steps to prevent further loss or damage once the event was discovered  for repair or replacement of the apparat us, tank or pipe itself …. If you selected Insured events cover, we do not pay for loss or damage w hich:  results from wat er escaping from a shower base not fitted with a tray or waterproof membrane;  is caused by the porous condition of any tiles, grouting or sealant …. Exclusions We will not pay for loss or dama ge … resulting from or caused by: …  inherent defects, structural defects, faulty workmanship, faulty design However, we will pay for result ant loss or damage that is caused directly by an Insured event if you did not know about, or could not reasonably have known about, the defect, faulty de sign or faulty workmanship at the time of the loss. Under no circumstances will we repair the inherent defect, structural defect, faulty workmanship or faulty design that caused the loss, not any loss that is Case No: 506205 Determination Page 10 of 10 Subject Terms caused by the inherent defect, structural defec t, faulty workmans hip or faulty design that is not directly caused by an Insured event. If there is event that a defect previously caused damage, we will not pay any claim for furt her damage by an Ins ured event arising from this defect.  wear, tear, rust, c orrosion, depreciation or gradual deterioration or any gradual process;  settling, shrinkage or expansion in buildings, foundations, walls or pavements …

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.