Claim denied for water damage under gradual deterioration and wear and tear exclusion
Text of the determination
Determination
Case No: 501551 Determination Page 1 of 12
Case number: 501551 30 August 2018
1 Overview
1.1 Dispute
The applicant lodged a claim in October 2017 on his home insurance policy held with
the financial services provider (FSP) for water damage to a bathroom, hallway and
bedroom caused by a leaking pipe.
The FSP declined the claim and says the damage was most likely caused by gradual
deterioration, depreciation and wear and tear and not by a listed event within the
terms of the policy.
The applicant disputes the FSP’s decision.
1.2 Issues and key findings
Has the applicant established a claim within the terms of the policy?
The policy provides cover for loss or damage as a result of water escaping from
amongst other things, a shower base or shower wall. Based on the information
provided the damage most likely arose as a result of water escaping from the shower
base or wall. The applicant has established a claim within the terms of the polic y.
Has the FSP established the application of an exclusion?
I am satisfied the FSP has established that the proximate cause of the damage is
gradual deterioration, depreciation and wear and tear of the shower recess due to the
grout and silicone failure. The FSP is entitled to deny liability for the claim based on
the exclusions within the terms of the policy.
Is the FSP liable for the portico damage?
The applicant has not established the leaking external pipe was the proximate cause
of the damage to the portico.
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitled to rely upon the terms and conditions of the policy to refuse
payment of the applicant’s claim .
Case No: 501551 Determination Page 2 of 12
2 Reasons for determination
There has been a full exchange of material between the parties and each party has
had the opportunity of addressing the issues that arise from the information
exchanged.
This determination is based on what is fair in all the circumstances, having regard to
the relevant legal principles, terms of the policy, good industry practice including
codes of practice and prior determinations where applicable.
2.1 Has the applicant established a claim within the terms of the policy?
Applicant bears the onus to show policy covers the damage
The applicant’s policy is a household insurance policy that provides cover for certain
listed events including water or liquid damage. The policy provides that it will cover
for loss or damage as a result of water or liquid escaping from amongst other things,
a fixed pipe, bath, basin, sauna, spa, shower base or shower wall, sink, toilet or tiled
floor with drain holes.
Circumstances of damage
The applicant believes that a leaking pipe under the house has caused damage to
the bathroom, rear hallway, bedroom 3, the floating timber floor and the carpet of
bedroom 3.
The parties do not dispute that there was a leaking external pipe between the water
main and front tap outside bedroom 4 in the property (the southwest corner of the
house). Whilst there has been discussion as to whether there are other leaking pipes,
the applicant’s plumber and the FSP have confirmed that there are no other leaks.
There were no leaking pipes in either bathroom identified or in the laundry or kitchen.
Internal building damage likely due to issues with shower recess
The policy provides cover for water escaping from a shower base or shower wall,
sink, toilet or tiled floor with drain holes.
The reports provided by the FSP through (CW), its assessor and (CC) indicate that
most likely the damage sustained to the bathroom, bedroom, toilet and laundry was
due to water leaking or escaping from the shower recess or shower wall.
In this respect, I accept that the applicant has established a prima facie claim within
the terms of the policy. The onus is therefore on the FSP if it wishes to establish the
application of a relevant exclusion.
2.2 Has the FSP established the application of a relevant exclusion?
Onus on the FSP to prove application of exclusion
The onus is on the FSP to establish that the proximate cause of the damage relates
to an excluded event. The proximate cause of the damage is the dominant or
Case No: 501551 Determination Page 3 of 12
effective cause of the damage. It is not necessarily the first or last or sole cause of
the loss.
Both parties have provided a number of reports on the cause of the building damage.
These are set out in section 3.2 of this determination. Whilst it is not in dispute there
is a leaky external pipe outside bedroom 4, the information does not support this is
the proximate cause of the damage.
The applicant’s inspector (H P) says water from the leaky external pipe had flowed
below the house slab, filled the gas pockets, and soaked into the slab and causing
various damage to the building.
However, t he FSP’s building consultant, CC, says:
the internal wall and carpet located closest to the site of the external pipe leak is
not wet
given the permeability of sandy soil and the rate of the leak, water would
infiltrate rather than flow horizontally under the slab
water from this leak is highly unlikely to flow horizontally from the southwest
corner of the house to the area surrounding bathroom
a compliant house has a waterproof membrane under the slab which would
prevent moisture from soaking up into the slab
the areas closer to the shower have a higher moisture reading, comparing to
those area further away from the shower. This is consistent with a shower leak,
with the effect of this leak causing damage diminishing over distance.
The available information shows it is more likely than not that the damage was due to
issues with the shower recess.
Damage caused by failure of the grout and silicone in the shower
It is not in dispute the applicant had previously lodged a similar claim in 2014. From
the information available, the FSP declined the 2014 claim because its assessor
(MC) found no leaking pipes but identified bathroom maintenance issues as the
cause of the water damage to the surrounding walls.
The applicant claims he had the shower recess re -sealed since 2014. Despite this,
the FSP’s plumber, CW, found the following issues with the shower recess:
silicone in poor condition
tile grout failure
tap o rings are leaking severely allowing water to leak back into wall
lack of adequate moisture barrier behind the tapware
no silicone to tap spindles.
The grouting issue was confirmed by HP who noted:
the shower floor has previously been re -grouted
this was poorly carried out. It appears as if the original grout was not removed
and new grout has been applied over the top. There are several sections where
this has come away.
CC noted the following issue with the shower recess:
flexible sealant has been retrospectively applied within the shower
Case No: 501551 Determination Page 4 of 12
the sealant has been applied over previous grout in corners and over the
grouted tile joints in the base and lower walls. The sealant has been used
inappropriately as a coating for the grout
the entire installation is defective and dysfunctional
sealant has broken away from the surface in numerous areas. Sealant is mould
covered in some areas indicating the current application is relative ly old.
Based on the information exchanged, most likely the cause of damage to the
bathroom, hallway, bedroom and floor was the result of water leaking from the
shower recess. The information establishes that leakage was most likely caused by
the failure of the grout and silicone within the shower recess.
The information establishes that the shower recess leaked because of issues with
worn or missing grout, faulty sealing application and lack of moisture barrier behind
the tapware. The water most likely leaked into this surrounding area and was
retained by the slab. Over time, the slab would have released the water back into the
surrounding area, causing the damage now observed. Such damage is properly
classified as being due to gradual deterioration, depreciation and wear and tear.
The policy specifically excludes damage caused by gradual deterioration,
depreciation and wear and tear, as well as faulty workmanship.
I am satisfied that the FSP has established the application of the exclusion and
accordingl y, is entitled to deny the applicant’s claim in accordance with the terms and
conditions of the policy.
2.3 Can the FSP decline the portico damage?
Applicant has not established the portico damage is due to the leaky pipe
It is not in dispute the bottom course of bricks at the portico (near the front entrance)
is damp. The applicant says dampness is also due to the leak from the external pipe.
On the information available, I am not satisfied the applicant has established an
insured event caused the damage. That is, the applicant not established this damage
was due to an escape of liquid from the leaky pipe.
HP could not identify a reason for the moisture reading in the portico area. He
assumed the source of the moisture is related to the leak from the e xternal pipe
(approximately 4.8m away). HP also says there may be a gas pocket below this area
that facilitated this water damage.
CC challenges this and says:
there is no information to show there is a gas pocket, or that it is responsible for
the water damage
the portico paving is mostly flat/level, and some areas falls towards the house.
This is defective surface drainage because it would facilitate moisture infiltration
the lower wall and/or the applied render is not isolated from the soil moisture
sufficiently to prevent moisture absorption and rising damp
Case No: 501551 Determination Page 5 of 12
as a result of the surface drainage issue, and lack of membrane protection for
the rendered surface from the ground, this allowed moisture absorption and
rising damp.
I am not satisfied the available information is sufficient to establish a relationship
between the leaking pipe and the portico damage. The FSP is therefore entitled to
decline cover for the costs to repair the portico damage.
Case No: 501551 Determination Page 6 of 12
3 Supporting information
3.1 Key policy wording
Listed events cover
We will cover your building or contents for loss or damage as a result of the incidents listed
on the following pages.
…
Any cover we provide is subject to exclusions.
…
Water or liquid damage
We will cover your buildings or contents for loss or damage caused by water or liquid. We
will also cover the cost of finding where the water or liquid escaped from, including the cost
of repairing any damage that occurs while looking for the cause.
We will only cover loss or damage as a result of water or liquid escaping from:
A fixed pipe or an object attached to a pipe, fixed gutter, fixed tank or a drain
A bath, basin, sauna, spa, shower base or shower wall, sink, toilet or tiled floor that has
drainage holes
…
We will not cover the cost of repairing the item that caused the escaped of water or liquid
escaped from. Or the cost of fixing or finding leaks that have not caused loss or damage to
your buildings or contents.
…
Exclusions to your cover
Any cover we provide is subject to the following exclusions.
…
We will not cover any loss or damage as a result of, or caused by:
…
- erosion, rust, corrosion, gradual deterioration, depreciation, wear or tear
…
- A defect in an item, structural defects, or faulty workmanship or design
…
- Because of a structural defect, faulty design or faulty workmanship when your
buildings were constructed.
Case No: 501551 Determination Page 7 of 12
3.2 Key records
Record Key points
FSP’s expert ( MC )
Report
4 - 9 - 2017
T he insured advised that he originally reported this issue to [FSP]
approximately three years ago and was advised that the damage
was caused by a leaking shower recess. He had the shower
recess re - sealed but has found the damage has carried on getting
wors e.
Caus e of damage: There are a number of walls surrounding the
bat hroom which have sustained water damage and arc recording
moisture levels of 100% to bottom half of wall. Your insured
advis ed that this has been an ongoing issue which he previously
had review ed but at that time the cause was thought to be water
escaping through tiles/grout of the bathroom shower recess.
FSP’s expert ( CW )
Report
Undated
Cause of damage
The main cause of damage is likely due to silicone and tile grout
failure. The tap o rings are also leaking severely allowi ng water to
leak back into wall . It is likely there is a leaking pipe on the property
but it is not rel ated to the damage in the hall way.
Silicone in poor condit ion
Lack of adequate moisture barrier can be seen behi nd the t apware
Grout looks t o be in poor conditi on
Damage is not consistent with a burst pipe
Tap ware in poor condition
O rings lea king into wall
Fibre washer were weeping
No silicone to tap spindles
Pressure test passed to shower breech
Pressure test failed to property (leak could be in the ground
a nywhere on property)
Shower screen in poor condition
Shower screen fa ils spray test
Maintenance issue s:
Reseal shower screen
Service tap ware
Tiles will have to b e removed and a suitable moist ure barrier
installed
Conclusion
Water damage to hall way and bedroom is no t con sistent with a
burst pipe
To completely rule out the bathroom for a water leak we can cut off
pipe work and isolate the bathroom, then conduct anot her pressure
test to the property. If the pressure test still fails we know that the
damage to the hallw ay has nothing to do with a burst pipe.
It is likely there is a leak in the ground on the water main and is not
ca using damage.
Reseal shower sc reen
Service tap ware
Tiles will have to be removed and a suitable moisture barrier
insta lled
Case No: 501551 Determination Page 8 of 12
Wall s to dry out
O nce this is done rep airs can commence
FSP’s expert ( CW )
Report
Undated
Client discussion
Tried to explain finding to client over t he phone
He doesn't believe what I tel l him and said that I should have
carried out a leak detection to his entire property. I tried to explain I
can only work in area of res ulting damages.
Conclusion
As instructed I isola ted the bathroom water feeds and performed a
separate pressure test to the property
The pressure test has failed and dropped consistently with a water
leak to the property
Because the bathroom had been isolated and was not under t est it
shows that the water dam age in the bathroom is not related to a
burst pipe
I recommend the client has a plumbing company attend to locate
the leak on the property as it is rot s howing any resulting damage
and advanced leak detection will be required
Water damage to hallway wall is relat ed to original leak report .
Applicant’s expert ( KS )
Report
undated
I have loc ated a leak at [applicant’s house] running below ground
between the Laundry and the kitchen. I ran tracer gas through the
cold water system and picked up readings in this area. The cold
water line running through this area needs to be repaired or
replaced.
Applicant’s expert ( KS )
Report
undated
I have loc ated a leak at [applicant’s house], the leak is between the
meter and the hot water unit on the side of the house. All other
lines were capped and pressure tested independently to check for
leaks. The leak is quite severe as can be witnessed by the damp
occurring to the front entrance and the damp inside where water
has penetrat ed as witnessed by a building inspector. The damp is
in the bathroom, bedroom adjacent to the leak.
After testing back from these points the pressure held in the lines.
The lines were tested to 150 0kpa for 30 minutes each and no
pressure drop was noted.
Applicant’s expert ( KS )
Email
26 - 09 - 2017
T his email serves to confirm a leak has been det ected which would
involve chopping int o th e wall to find and repair.
Applicant’s email
Email
6 - 10 - 2017
I ref er to my telephone conversation this morning with a consultant.
She confirmed that you have received the report from [KS]
regarding the finding of a leak bet ween the bathroom and the
kitchen. I spoke with D from KS and he confirmed that it is a
substantial leak wasting up to 5 litres of water per hour.
The water leak has been there undetected at least since 2014
when I made a similar claim for property damage after the walls in
the bathroom begun to show water damage which is worse now.
We began closing the main water tap about 4 - 5 weeks ago. Until
then, up to five litres of water per hour were impregnating or
soaking the house slab. Daily, it amounts to 120 litres, monthly to
Case No: 501551 Determination Page 9 of 12
3,600 and yearly to 43.200. This water has accumulated under the
floor and it is n ow raising or evaporating through the walls and
floor, damaging them thereby.
Applicant’s expert ( HP )
Report
18 - 01 - 2018
I inspected the property at [applicant’s house], on 9th January
2018 at 9.00 am and 24th January 2018 at 7.30 am with
Complainant and D from KS in attendance.
Water ingress into walls and floors
I am advised that the plumbing lead in pipes into the property, as
tested by the plumber, holds pressure and hence are unlikely to
contain a leak.
Testing by the plumber indicates that the leak to the pipe is
between the garden tap and the water meter. It is most likely close
to the house corner. This area cannot be excavated without the
removal of the plants.
It is possible that this is the source of water ingress into the
property below the sla b and filling the gas pockets. This may be
soaking up into the slab and walls that is then causing the
identified damage
Water damage to portico pier on the south side
The bottom course of bricks to the face brick wall appear to be
damp.
There is not an im mediate reason for the high moisture readings in
the walls in this area given the lack of roof plumbing or plumbing.
We can only assume the source of moisture ingress relates to the
issue identified in item 3.
High moisture reading to walls, bathroom vanit y cabinet,
bathroom, WC and general floor areas
24th January 2018. There is a very high moisture reading to these
walls with damage to the hardwall plaster.
There is a high reading to the base of the bathroom vanity cabinet
and there is high moisture readi ng to the bathroom and WC
general floor areas.
Note - the shower floor area tests dry but there is some moisture to
the floor to wall grouted joint. The shower floor has previously been
re - grouted. This was poorly carried out. It appears as if the original
grout was not removed and new grout has been applied over the
top. There are several sections where this has come away.
The shower and vanity basin reportedly have not been used since
the start of July 2017. The amount of moisture still present in the
wal ls and floor grout indicated that the moisture is coming from
another source. As shown above there are no leaks in the pipes
and when tested there is no moisture in the wall around the shower
outlets.
There is high moisture readings and apparent damage to walls,
bathroom vanity cabinet, bathroom, WC and general floor areas
The position appears to be improving but this may be related to the
limited use of the shower.
These tests show a high moisture reading to the grout to the main
floor areas of the bathroo m and WC but the shower floor tests dry.
Bathroom shower recess, bathroom and WC floors
Case No: 501551 Determination Page 10 of 12
24 January 2018. Moisture tests to the grout to the bathroom
shower recess, bathroom and WC floors.
These tests show a high moisture reading to the grout to the main
fl oor areas of the bathroom and WC but the shower floor tests dry.
Laminate floor to passage outside bathroom, rear bedroom 2,
laundry, kitchen and wc
Moisture met er readings taken on top of the timber laminated
flooring indicate high moisture readings from the passage outside
the bathroom, rear bedroom 2 entry to the bathroom, WC and
laundry entry alcove and around to the kitchen passage.
Bathroom cabinet
The bathroom cabinet has a moldy smell. This was tested to the
base that showed a high moisture reading.
It is possible that the waste pipe is leaking at the slab junction but
as the client has indicated that this bathroom has not been in use
since the start of June 2017 it is possible that moisture is rising up
around the waste pipes.
Given the tests undert aken by the plumber and documented in this
report it appears that there is a leak in the external lead in
plumbing pipe between the garden tap and the water meter.
Applicant’s expert ( KS )
Email
18 - 01 - 2018
Today I isolated your water supply in sections. I tightened up all
cold water fittings were gas might escape and re tested your
system. After testing in sections I found the following:
1) The first bathroom has no leaks.
2)The Laundry has no leaks.
3)The kitchen has no leaks.
4)The main bathroom has no le aks.
The gas readings I picked up in the kitchen and laundry and
passage are coming from a major burst waterline outside the
corner b edroom to the water meter. This would explain the damp
problems in the bedrooms, bathroom as well as the front of your
hous e at the entrance were the inspector picked up high moisture
readings.
FSP’s building
consultant ( CC )
Report
28 - 03 - 2018
Causation Di scussion and Asse ssment
Inspection and test findings are consistent with water ingress into
the building structure and fabric through the shower recess based
on the following:
No water pipe leaks were identified under the house. A small 0.5
Litre / minute leak was identified external to the house. In a
permeable sandy soil, it is implausible that the leak could flow a
hori zontal distance of between 4 and 8m under the slab and be
"soaked up" through an impermeable slab membrane, resulting in
high moisture levels and damage, as has been speculated by [HP] ;
The following points support the position that Shower Recess is
leaking and there are no other plausible sources of leaks in the
area:
a) Floor tiles within the recess have a high moisture reading, 9
months after the shower usage was report edly stopped;
b) The laminated timber floors adjacent the shower have high
moist ure readings, and these diminish with separation from the
Case No: 501551 Determination Page 11 of 12
shower;
c) The moisture content of the tiled floors (which are located on
cementitious toppings) in the Bathroom, Toilet and Laundry
generally diminish with separation distance from the Shower.
Exce ptions to this statement result from the effect of anomalies
including negative fall on the floor between the shower and the
bathroom entry door; a lack of seals under the shower door; the
presence of a sand filled surround around the bathtub, which
increa ses moisture contents in surrounding materials; and a floor
set down under the vanity located adjacent the shower;
d) Visible signs of moisture damage diminish with distance from
the shower;
e) Only the plastered masonry walls around the Bathroom and
immed iat e attached walls in the vicinity have significant visible
moisture damage. The wall across the passageway for instance
displays only minor damage, consistent with reduced moisture
effects;
f) The South Wall of the Southwest Bedroom and the flooring
with in this room is not moisture damaged, notwithstanding that it is
the closest area of the house to the section of leaking pipe
between the Hot Water unit and the Water Met er. This shows that
the identified wat er pipe leak has no effect on the closest part o f
the building to the leak. It is therefore improbable that the leak
could affect an area of the building further away;
g) It is implausible that moisture would penetrate vertically through
the slab membrane from below;
h) Water pipes are not located under the bathroom floor or within
the slab. Water pipes are routed horizontally in the walls above the
floor level. Water pipes within the Bathroom, Toilet and Laundry
are not leaking based on the Owner's plumbing test report;
i) Moisture within the floor rece ss below the vanity is consistent
with leaks through the adjacent shower membrane;
j) Corrosion on the door frame adjacent the shower is consistent
with 1. high moisture within the topping below the floor tiles
adjacent caused by failure of the shower memb rane; and 2. water
penetration through the shower door and discharge toward the
doorway across the negatively graded floor;
…
[HP] does not consider that the current moisture causing the
damage is emanating from within the slab which was previously
saturat ed due to long term shower membrane leaks.
Notwithstanding the time since the shower was last used, the slab
is not yet dry due to the following reasons:
a) The slab has been subjected to long term hydration processes
which result in a reduction in permeab ility. Refer to the Section 6
Item j) reference document which advises that drying of an older
slab takes twice as long as drying of a new slab based on the
research referenced therein;
b) Slab areas that are under topping and tiled floors, or timber
floor s which limit moisture vapor evaporation due to shielding and
lack of air flow, remain wetter for longer due to reduced local
Case No: 501551 Determination Page 12 of 12
moisture permeation rates;
c) Potentially, the under - slab plastic membranes have been
damaged or were not sealed during the origin al sewer pipe
installations within the slab. This will increase moisture adsorption
into the slab locally and may contribute to increased moisture
levels. defective or failed membrane texture paint protection for the
render below the paver surface and or d efective masonry damp
coursing.