Water damage claim denied under shower leak exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2018-05-28
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for water damage to an investment property from shower leaks. AFCA found the policy exclusions for faulty shower screens or bases and gradual leaks applied, so the FSP was entitled to deny the claim.

The damage was caused by leaks from faulty shower screens and bases and occurred gradually, both of which the policy excludes.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 501296 Determination Page 1 of 5 Case number: 501296 28 May 2018 1 Overview 1.1 Dispute The applicant lodged a claim under his home insurance policy with the financial services provider (FSP) for damage to his investment property caused by the escape of liquid in the bathrooms. The FSP denied the claim. It says the damage arose from factors the policy excludes: leaks from a faulty or defective shower base or screen, and leaks occurring gradually over time. The applicant believes the real cause of loss was loose or damaged connections to the waste and trap in each shower. The FSP maintains it can still deny the claim, relying upon the same exclusions. The case manager issued a recommendation in favour of the FSP, but the applicant did not accept it. 1.2 Issues and key findings Can the FSP deny the claim? The FSP can deny the claim. This is because although the policy covers loss or damage caused by an ‘ escape of liquid ’, th e cover is subject to specific exclusions for leaks from faulty or defective shower screens or shower bases , and leaks occurring gradually over time. 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny the claim and is not required to take further action. Case No: 501296 Determination Page 2 of 5 2 Reasons for determination I have decided this case on the basis of what I consider fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. For the purposes of this determination, I will deal with only those points considered relevant. 2.1 Can the FSP deny the claim? Policy covers damage caused by an escape of liquid subject to exclusions The applicant claims under a home building and contents policy which covers loss or damage occurring at the insured property. The policy responds to damage caused by certain risks only, called ‘listed events’, as well as providing cover for accidental damage. Cover is subject to general exclusions (which apply to all policy sections) and specific exclusions (which apply only to the listed event they are attached to). The relevant listed event is ‘escape of liquid’. The initial burden of proof is with the applicant to show, on the balance of probabilities, the loss suffered was caused by an insured event. If the applicant can establish a valid claim, the burden of proof shifts to the FSP to show, on balance, that the policy excludes the claim, or that it is otherwise not covered. Parties disagree about the cause of loss When lodging the claim in 2016, the applicant is reported as saying (based on information from the tenant) that after both showers were used, water was pooling outside the shower recesses; there was damage to the paint on the ceilings and to the surrounding walls. The FSP sent a builder (JLG) to inspect and determine the cause of loss. JLG appointed a plumber (DPR) to conduct a series of pressure tests for both showers. DPR reported that a breakdown of the grout, silicone and waterproof membrane in each shower meant water was escaping (through the screen and base) and damaging adjacent areas. No leaking pipes were found. The applicant commenced repairs himself, and after the tiles and shower bases were removed, he says he found liquid was escaping through loose or damaged connections to the shower waste and shower trap fittings. The applicant provided photographs and a report from a plumber (DPD) to support his position. The applicant says he asked the FSP to attend the property and inspect the issues with the waste and trap connections, but it did not do so. Case No: 501296 Determination Page 3 of 5 Exclusions apply to defeat the claim The applicant’s policy covers loss or damage caused by an escape of liquid, but the FSP denied the claim relying on two specif ic exclusions to the ‘escape of liquid’ event: leaks from a faulty or defective shower screen or shower base, and gradual leaks occurring over time. G eneral exclusions also apply for ‘wear and tear and lack of maintenance’, dampness and ‘gradual loss or damage of any kind’. I acknowledge the applicant’s submission that loose or damaged shower waste and shower trap connections in both showers caused the damage. However, I am satisfied the evidence (including photographs) more compellingly supports the FSP’s argument that the obvious damage that was first identified was caused by leaks from faulty or defective shower screens. In any case, I consider the damage suffered – however caused, and whether immediately obvious or not - occurred gradually over time and not as the result of a specific sudden or unexpected ‘escape of liquid’ event. That means the FSP is entitled to decline the claim. FSP is not liable for other costs incurred by the applicant The applicant also asked the FSP to cover costs he would incur following the event, such as lost rent, marketing and agent fees associated with re-tenanting the property. The FSP would only be liable for these costs in circumstances where the loss was caused by an insured event under the policy, which is not the case here. That means the FSP is also not liable for the other costs incurred by the applicant in relation to the water damage. Case No: 501296 Determination Page 4 of 5 3 Supporting information 3.1 Policy terms Escape of liquid What is covered Your building and/or contents are covered for loss or damage caused by the sudden and unexpected escape of liquid from any:  water main;  fixed water pipe (but not a garden hose);  fire hydrant;  pool or spa;  fixed water feature;  fixed tank;  washing machine or dishwasher;  sink, basin, bath or toilet;  sealed portable heater; or  fixed heating or cooling system. What is not covered You are not covered under this insured event for:  loss or damage caused by any escape of liquid of which you were aware and failed to notify us of within a reasonable period;  loss or damage resulting from a leaking or faulty shower recess or shower base;  loss or damage caused by any gradual escape of liquid… 3.2 Expert reports Record Key points Applicant ’s plumber ( DPD ) Report 3 - 10 - 2017  Inspected central bathroom and ensuite.  Shower trap fittings are damaged causing water to run from under the base.  Appears escaping water penet rated into the timber studs contributing to rising damp.  Replaced both fittings with new 50mm traps and rubbers and new puddle flange with new fittings and seals.  No t possible for an occupant to have known what was occurring without exposing the shower to the framework.  Caus e of damage inconclusive as no indication what caused the leak but issue now rectified. FSP’s builder ( JLG ) Builders Report and Quotation 23 - 11 - 2 016  Tenant says after both showers are used wat er pooling outside shower recess.  Water damage at both shower recesses (bathroom and ensuite).  Broken grout and silicone to both shower recesses not ed.  No leaking pipes observed during pressure testing.  Main bed ens uite: wall plaster and skirting outside of shower recess affected along with vanity kicker. Case No: 501296 Determination Page 5 of 5  Bathroom: wall plaster and skirting outside of the shower recess affected with vanity.  Main bedroom walk - in - robe: two by two wall plaster mouldy and 2m of sk irting affected.  Dining/Kitchen: 6m skirting affected and with eight by two wall plaster mouldy. FSP’s plumber (DPR) Plumber Report 21 - 11 - 2016  Leaks have come from the bathroom shower, a breakdown of silicone, grout and membrane causing issues in the hallway and backroom plaster.  First test was five minute pressure test on the shower taps and rose, no leaks found.  Second test was spraying the shower screen with water. Leaks found on bot h sides of the screen.  Third test was filling the tile base with wa ter, leaks seem to come from the base, when base was full of water.  Dampness on back wall and kitchen plaster found aft er testing.  Shower spindles have no silicone behind the taps in the shower.  Grout, silicone and membrane breakdown have caused the shower issues.  Ensuite shower issues come from a grout, silicone and membrane issue also, with water damage to the laundry and walk in robe plaster wall.  First test was five minute pressure test on the shower taps and rose, no problems observed.  Second test was a shower wat er screen test, leaks have come from the screen.  Third test was water filling the tile base wit h water and find water from this test is seeping into the two rooms from the breakdown of grout, membrane and silicone. 3.3 Other documents relied upon  Written submissions from the applicant and the FSP.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.