Home / Financial Firm (Unknown - Insurer) / Determination 500944

Determination 500944

Bathroom subfloor damage partly declined as shower recess leak and workmanship

FirmFinancial Firm (Unknown - Insurer)
Decided2018-06-14
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

An applicant claimed for bathroom subfloor damage after a vanity leak, and the FSP accepted the vanity damage but declined the subfloor as caused by a shower recess leak and faulty workmanship. AFCA agreed and ordered nothing further.

The majority of subfloor damage was caused by water escaping from a shower recess and failed waterproofing, which the policy excludes.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 500944 Determination Page 1 of 3 Case number: 500944 14 June 2018 1 Overview 1.1 Dispute The applicant holds a home building policy with the financial services provider (FSP) covering the applicant’s building for the period 18 February 2017 to 18 February 2018. A claim was lodged on the policy on 22 August 2017 for water damage sustained to the bathroom. The FSP accepted the claim for damage to the vanity caused by a leaking pipe but has otherwise denied the claim for the remaining damage. The FSP says the remaining damage was caused by water escaping from a shower recess which is excluded from cover. This dispute has been the subject of a recommendation. The recommendation was in favour of the FSP. The applicant has disputed the recommendation. A copy of the recommendation is attached to this determination. 1.2 Issues and key findings Has the applicant established a valid claim under the terms of the policy? There is no dispute that the applicant has established a valid claim under the insured event ‘water and oil leaks’. Was the FSP entitled to refuse part of the claim? Based on the available information that the FSP is only liable for the damage sustained to the vanity as a result of the leaking pipe, I am satisfied that the FSP is otherwise entitled to refuse payment of the claim as, on the balance of probabilities, the damage was caused by the failed waterproofing to the shower area causing water to escape from the shower recess or shower base. 1.3 Determination This determination is in favour of the FSP. I agree with the findings contained in the recommendation and agree that the FSP is entitled to refuse the part of the claim that relates to water escaping from the shower recess and shower base. Case No: 500944 Determination Page 2 of 3 2 Reasons for determination There has been a full exchange of material between the parties and each party has had the opportunity of addressing the issues that arise from the information exchanged. In rejecting the recommendation the applicant says that the case analyst had failed to take into account a report from his plumber. The applicant maintains that the cause of damage to the floors was the leak from the vanity. This determination follows consideration of all of the information exchanged incl uding information provided following the recommendation. It is based on what is fair in the circumstances, having regard to the relevant legal principles, terms of the policy, good industry practice including codes of practice and prior determinations where applicable. 2.1 Has the applicant established a valid claim? The applicant has established a valid claim The applicant’s policy provides cover for loss or damage arising from a series of listed events including ‘water and oil leaks’. Under this listed event cover is provided for loss or damage caused by water leaking or escaping from amongst other things sanitary fixtures including baths and toilets and from appliances. The applicant provided a report from MN, his plumber, who confirmed that there was a leaking pipe in a vanity unit. The cause of the leak was a faulty flex connection. The FSP’s assessor AJG confirmed that the vanity had been connected incorrectly causing water to run down the outside of the pipe and leak indirectly onto the subfloor. I am satisfied based on the reports provided that the applicant has established a prima facie claim for cover under the terms of the policy for the listed event of ‘water and oil leaks’. I acknowledge that the FSP has in fact accepted liability for the damage to the vanity and agreed to indemnify the applicant. The FSP has agreed to cover the costs of the damage sustained to the vanity. 2.2 Is the FSP entitled to refuse part of the claim? Insofar as the damage to the subfloor is concerned the FSP relies upon the exclusions contained within the terms of the policy to refuse payment of the claim. The FSP has the ouns to establish the application of an exclusion. Under the insured event ‘water and oil leaks’ the policy provides specific exclusions relating to loss or damage caused by water leaking or escaping from a: - shower recess or shower base Case No: 500944 Determination Page 3 of 3 Under the general exclusions that apply to the policy the policy excludes cover for loss or damage arising from: - rust, corrosion, gradual deterioration, depreciation, wear or tear - faulty design or workmanship - failure to maintain your home in good repair or condition. The FS P’s builder, AJG found: 1. that damage had been caused by failed waterproofing to the shower area which has caused major damage to the subfloor 2. the vanity has been connected incorrectly causing water to run down the outside of the pipe and leaking directly onto the subfloor. The applicant disputes this and relies upon his plumber MJ who maintains that: - the damage to the vanity was caused by the water leak - damage to the subfloor would have been caused by the water leak. I accept that some damage to the subfloor may have been caused by the leaking pipe to the vanity. I accept however that such damage is likely to have occurred gradually and be due to the faulty workmanship in the installation of the pipe. The available evidence indicates that the pipe had been connected incorrectly. I accept however that the majority of the damage to the subfloor was most likely caused as a result of either lack of or faulty waterproofing causing the shower recess to leak badly. The FSP’s plumber ZP conducted a number of leak detection tests. In his leak detection report Z commented that there was clear evidence of water damage around the shower recess and the leak test showed the shower was leaking badly. Z considered the entire floor had rotted and swollen with damage but noted there was no leak present within the wall. Although the applicant disputes these findings, other than two very brief reports from MJ which do not refer to the leaking shower recess and a building and final inspection certificate, there is no information to support the applicant’s position. I agree with the findings contained in the recommendation and agree that the FSP is entitled to rely upon the terms and conditions of the policy to refuse payment of the applicant’s claim for damage to the subfloor on the grounds that it is due to:  water leaking or escaping from a shower recess or shower base  damage due to gradual deterioration  damage due to faulty design or workmanship Recommendation Case No: 500944 Recommendation Page 1 of 7 Case number: 500944 30 January 2018 3 Overview 3.1 Dispute The applicant held a home building and contents policy with the financial services provider (FSP). On or about 22 August 2017, the applicant lodged a claim for water damage sustained to a bathroom at the insured property. The FSP have partially accepted the claim for resultant damage due to water escaping from a leaking pipe. However, the FSP maintains that the remainder of the claimed damage was caused by water escaping from a shower recess and inadequate waterproofing; and as such is excluded under the policy terms and conditions. The applicant disagrees with the FSP decision. 3.2 Issues and key findings Has the applicant established a valid claim under the policy? The applicant has established a valid claim as the policy provides cover for ‘water and oil leaks’. I am satisfied the information provided shows water damage was sustained to the insured property. Was the FSP entitled to partially deny the claim? Based on the available information the applicant has not been successful in establishing, on the balance of probabilities, that all the damage claimed was solely caused by an insured event under the policy. In the circumstances, the FSP is entitled rely on its exclusions to partially deny the claim. As such the FSP can limit its liability in accordance to the policy terms and conditions. 3.3 Recommendation The recommendation is in favour of the FSP. The FSP is entitled to partially deny the claim. Case No: 500944 Recommendation Page 2 of 7 4 Reasons for recommendation 4.1 Have the applicant established a valid claim? Applicant has initial onus to establish claim In order to claim under a policy, the initial onus is on the insured to show the damage was caused by an event covered under the policy. This is known as a prima facie claim. If the insured can establish a prima facie claim, the onus then shifts to the FSP to show the damage claimed is excluded under the policy or that it is otherwise entitled to deny the claim. The applicant’s policy provides cover for loss or damage caused by defined events (listed events), subject to the various conditions and exclusions set out in the policy. One event is ‘water and oil leaks’ . Therefore, for the applicant to establish a prima facie claim, he must demonstrate, on the balance of probabilities, the damage was solely caused by a water leak. Applicant established a valid claim The expert reports provided by the parties establish that the applicant’s bathroom sustained water damage. On this basis, I am satisfied that the applicant has established a prima facie claim, given the policy pro vides cover for ‘ water and oil leaks’. In these circumstances, the FSP then bears the onus of establishing that, on the balance of probabilities, it is entitled to rely on a policy exclusion to partially deny the applicant’s claim. 4.2 Was the FSP entitled to partially deny the claim? The FSP is required to demonstrate the loss was excluded The applicant says that the main source of the sub floor damage was the result of a water leak. The applicant further says the build-up of the water leak from the vanity onto the floor has penetrated and caused the floor to drop. The applicant has provided documentation from his plumber who inspected the damage. To date the FSP has assessed the damage and accepted part of the claim and agreed to cover resultant vanity damage due to water escaping from the leaking pipe. However, the FSP maintains its position to deny the remainder of the damage, in particular the subfloor; which it says was due to water escaping from a shower base or recess. It says damage caused in this fashion is excluded under the policy terms and conditions. Case No: 500944 Recommendation Page 3 of 7 As such the FSP seeks to rely on the following policy exclusions which clearly exclude damage caused by any of the following factors:  water leaking or escaping from a shower recess or shower base  rust, corrosion, gradual deterioration, deprecation, wear and tear  loss or damage arising from not maintain your home in good repair and condition  faulty workmanship. As the FSP seeks to rely on its policy exclusions, it must establish, on the balance of probabilities, the damage was due the above mentioned excluded events under the policy terms and conditions. Evidence indicates some of the damage was due to water leaking from a shower recess The FSP has relied on two expert reports to establish that part of the damage was due to excluded events under the policy terms and conditions. The FSP engaged a builder (AJG) to inspect the insured damage. In its report, dated 28 August 2017, AJG made the following observations:  found that damage has been caused by failed water proofing to the shower area which has caused major damage to the sub floor  the vanity has been connected incorrectly causing the water to run down the outside of the pipe and leaking directly onto the subfloor. The FSP also further engaged a plumber (ZP) to assess and comment on the damage. In its report, ZP noted the following:  the shower recess is leaking badly  water is cascading through the tiles then through the FRC and chipboard flooring  waterproofing and recess have become faulty. The applicant in support his of his position has provided two written reports from his plumber who assessed the damage. The plumber, MJ, in its two reports made the following observations:  damage to vanity was caused by water leak  damage to sub floor would have been caused by vanity leak  cause of leak noted as faulty flex connection. In addition, the applicant also provided a building and final occupation certificate dated, 17 February 2015. However, further commentary or expert reports as to the dominant cause of the damage have not been provided by the applicant. Whilst I acknowledge the applicant disagrees with the FSP’s decision to only cover part of the damage; the further report provided by the applicant lacks details and does not go as far to refute the FSP’s position regarding the damage. In the absence of detailed expert reports, I accept the two reports provided by the FSP which are found in Section 3.1 of this recommendation. Whilst I acknowledge the applicant ’ s arguments and acknowledge the documents provided by MJ, I have carefully reviewed the policy wording in relation to the Case No: 500944 Recommendation Page 4 of 7 exclusions relied upon the FSP. I am satisfied that part of the damage caused to the insured property falls within the exclusion as the reports indicate failed water proofing and failure of the shower recess which is clearly excluded under the policy terms and conditions. With such supporting expert reports noting workmanship faults, failure of water proofing and a leaking shower recess, I am satisfied the damage falls within the meaning of the policy exclusion. FSP entitled to deny part of the claim and limit its liability I have considered all the expert reports, photos and submissions as a whole in line with the policy terms and conditions. The applicant has noted concerns about the partial denial of the damage sustained the subfloor of the bathroom; however, the applicant’s independent plumber reports do not refute the FSP’s position and expert evidence. Whilst I acknowledge there has been independent reports provided by the FSP, I have also given consideration to the coloured photographs and individual party submissions and arguments. When considering whether the exclusion applies to defeat the claim, it is appropriate to first determine the proximate cause of the loss. What is the proximate cause of the loss is a question of fact depending upon the circumstances in each case. It is well established at law that a proximate cause is not necessarily the first or the last or the sole cause of the loss. It is the effective or dominant or operative cause of the loss. If there are several causes operating contemporaneously, then each must be examined for the qualities of predominance and efficiency as the active, efficient cause that sets a relevant train of events in motion. In this instance the information provided shows on the balance of probabilities, the proximate cause of damage escape of liquid from the shower recess and failure of water proofing as outlined in the expert report. As such, the FSP is entitled to decline part of the claim for damage to the subfloor. Case No: 500944 Recommendation Page 5 of 7 5 Supporting information 5.1 Policy Wording Water and Oil Leaks If loss or damage is caused by water or oil leaking or escaping from an item shown in this section. Covered Water leaking or escaping from: - Hous e gutters, drainpipes or pipes - Sanitary fixtures- for ex ample, baths or toilets - Appliances- for example, washing machines or dishwashers - Waterbeds - Aquariums - Water tanks - Swimming pools Oil leaking from a fixed heating system or sealed portable heater Costs to locate the cause of damage Not Covered Water leaking or escaping from a: - Shower recess or shower base - Storm water channel or canal - Storm water pipe of your site Costs to repair or replace the item that the water or oil leaked or escaped from Loss or damage caused by flood Loss or damage caused by storm surge […] Exclusions for all cover These exclusions apply to all cover under your policy. We don’t cover Loss. Damage, injury or death arising from: - […] - rust, corrosion, gradual deterioration, depreciation, wear or tear Maintaining and occupying your home We don't cover loss, damage, injury or deat h arising from: - faulty design or workmanship. […] - you not maint aining your home in good repair and condition. This means your home must be watertight, structurally sound, secure and well maintained - you not maint aining your site in good repair and condition Case No: 500944 Recommendation Page 6 of 7 5.2 Expert Reports Record Key points FSP’s expert (A JG ) Report 22 - 08 - 2017  Upon inspection the client advised when he installed his vanity unit the pipe work was installed incorrectly and he noticed over time water has begun tracking down the outside of the pipe as it is not sealed correctly causing damage to the sub floor.  …found that damage has been caused by failed water proofing to the shower area which has caused major damage to the sub floor.  The vanity has been connected inc orrectly causing the water to run down the outside of the pipe and leaking directly onto the subfloor.  Recommendation - this claim not be covered as the initial damage has been caused by water escaping the outside of the vanity unit waste pipe which is not covered as a particular eve nt …. There is no water proofing in the bathroom which would also contribute to the floor rot. FSP’s expert ( ZP ) Report 05 - 08 - 2017  On initial inspection it is clear that there is evidenc e of water damage around the shower recess in the bathroom.  A leak test was executed on the shower recess and inspection of underfloor was carried out.  It is clear that the shower recess is leaking badly.  Water is cascading through the tiles then through the FRC and chipboard flooring.  On closer observation the entire flo oring under the recess is rotted out and swallon with water damage which is causing it to fall away…..  It’s evident that wat erproofing and recess have become faulty.  A leak pressure test was then performed on the shower breach and it was found that pressur e within shower breech held, meaning no leak was present wit hin the wall. APP’s Expert (MJ) Report 07 - 10 - 2017  Caus e of leak noted as faulty flex connection.  Damage - vanity replaced, sub floor chipboard to be replaced, tiles to match, existing to be repla ced. APP’s Expert (MJ) Further Report 18 - 12 - 2017  Damage to vanity was caused by water leak.  Damage to sub floor would have been caused by vanity leak  I do not know what state the water proofing is in. 5.3 Other Supporting Information  Certificate of Insurance. Case No: 500944 Recommendation Page 7 of 7  Product disclosure statement.  Parties’ submissions

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.