Text of the determination
Determination
Case No: 497854 Determination Page 1 of 12
Case number: 497854 19 June 2018
1 Overview
1.1 Dispute
The applicant held a Pleasure Craft Insurance Policy with the financial services
provider (FSP) and lodged a claim after his boat was partially submerged on
31 December 2016.
The FSP subsequently declined the claim on the grounds the damage was due to a
combination of corrosion and lack of proper servicing and therefore fell within the
exclusions contained within the policy relating to wear and tear, corrosion and lack of
maintenance.
The applicant disputes the FSP‟s decision.
1.2 Issues and key findings
Has the applicant established a claim within the terms of the policy?
The panel is satisfied the applicant has established a prima facie claim within the
terms of the policy for accidental damage. The panel accepts that the blockage to the
heat exchanger was unforeseen and unintended and falls within the terms of the
policy.
Is the FSP entitled to refuse the applicant’s claim?
The FSP is not entitled to refuse the applicant‟s claim because:
the applicant has shown he has regularly serviced the boat and its engine
the FSP has not established, on the balance of probabilities, the servicing did
not include inspection/clean of the heat exchanger
the FSP has also not established buildup of material causing the blockage in
heat exchanger was due to corrosion
the FSP has not established any other relevant policy exclusions apply.
Is the applicant entitled to costs claimed?
Pursuant to paragraph 9.4 of the FOS Terms of Reference, the FSP is required to
contribute $3,000 towards the applicant‟s professional costs. The panel accepts it
was reasonable for the applicant to engage the services of an engineer to assist with
this dispute.
Case No: 497854 Determination Page 2 of 12
1.3 Determination
This determination is in favour of the applicant.
The FSP is liable to meet the applicant‟s claim for loss and damage arising as a
result of partial submersion of the boat on or about 31 December 2016. The FSP is
required to reassess the condition of the boat and to settle the claim in accordance
with the terms and conditions of the policy.
The FSP is required to contribute $3,000 towards t he applicant‟s professional costs
in accordance with paragraph 9.4 of the terms of reference.
Case No: 497854 Determination Page 3 of 12
2 Reasons for determination
2.1 Has the applicant established a claim within the terms of the policy?
Applicant has the onus to establish a valid claim
The applicant is required to show that, on the balance of probabilities, he has
suffered a loss caused by a risk insured against under the policy. This is known as a
prima facie claim.
The applicant‟s policy provides cover for accidental loss or damage to his boat,
subject to the conditions and exclusions set out in the policy. For the purposes of the
policy, “accidental damage” is defined to mean damage which occurs as the result of
a happening which is unforeseen and unintended by the Applicant.
Both the FSP‟s marine assessor (MA) and the applicant‟s engineer (RC) concluded
that it was ultimately a blockage in the engine‟s heat exchanger that caused the boat
to sink. The blockage in the heat exchanger lead to a series of connecting events:
The blockage meant no water was available to cool the shaft gland
The shaft gland overheated and seized on the propeller shaft
The propeller shaft then tore the connecting water hose
Water from the torn hose then flooded the boat, causing it to sink.
The FSP says the blockage in the heat exchanger:
was corrosion
a result of lack of proper servicing.
However, the panel is satisfied that both the blockage in the heat exchanger and the
damage to the boat was unforeseen and unintended by the applicant, at the time
these events occurred.
On this basis, the panel is satisfied that the applicant has established a prima facie
claim for accidental damage under the policy.
The issues raised by the FSP about the boat ‟s servicing and nature of the d amage
are more properly considered in the context of determining the proximate cause of
the damage (and therefore whether the FSP is entitled to rely on an exclusion under
the policy to deny liability).
2.2 Is the FSP entitled to deny the claim?
Cover for accidental damage is subject to exclusions
The FSP says it is entitled to decline the claim because the policy does not cover
loss or damage caused by:
wear and tear, mould, deterioration, vermin, corrosion, electrolysis or inherent
vice.
unseaworthiness, lack of repair or maintenance of the boat
lack of reasonable care, protection and/or security of the boat.
Case No: 497854 Determination Page 4 of 12
As the FSP is seeking to deny the a pplicant‟s claim based on a policy exclusion, it
bears the onus of establishing that, on the balance of probabilities, the relevant
exclusion applies.
In order to do so, the FSP is required to show that the proximate cause (that is, the
dominant, effective or operating cause) of the damage to the a pplicant‟s boat is one
of the excluded factors referred to above.
Available information does not establish lack of maintenance
It is not in dispute the engine manufacturer‟s maintenance schedule states the heat
exchanger should be inspected and cleaned every 1,200 hours and at least every 5
years.
Whilst the FSP accepts the boat‟s engines were regularly serviced, it says the heat
exchanger were not inspected as part of the services. In support, the FSP relies on
the service invoices.
The panel has reviewed the services invoices, and agrees the invoices do not
explicitly state the heat exchanger was inspected and cleaned.
However, the panel does not accept this establishes on balance, the heat exchanger
was never inspected or cleaned. This is because:
invoices shows the engine was serviced in 2012, 2013, 2014 and 2015
whist the service invoices do not state the heat exchanger was inspected and
cleaned, they also do not state the heat exchanger was not inspected or
serviced
in particular, MB‟s servicing invoice (dated 23 November 2015) only listed the
parts that were replaced as part of the service. It is open to conclude the heat
exchanger was inspected and serviced, but not replaced as part of the service
and therefore not recorded on the service invoice
the FSP did not contact any of the mechanics (including MB) to confir m or
clarify what servicing the engine involved (in particular as to whether the heat
exchanger was serviced). The FSP had the opportunity to do so.
The onus is on the FSP to establish the applicant of an exclusion clause. In the
current circumstances, it alleges the blockage of the heat exchanger was due to the
failure to maintain it as per the manufacturer‟s guideline.
The panel prefers the report prov ided by the applicant‟s expert R C and is satisfied
given the service history that on the balance of probabilities the heat exchanger was
inspected and serviced to a good practice standard. The FSP has not established
that it was likely the heat exchanger was not serviced.
The applicant also says the engine had not accumulated sufficient hours to warrant
inspection of the heat exchanger. However, he has not provided information on the
engine‟ s run time at the date of loss although the panel notes that as at 26 February
2016 it had recorded 823 hours.
Case No: 497854 Determination Page 5 of 12
Available information does not establish corrosion
The FSP says it was a build up of corrosion that blocked heat exchanger. It says the
policy excludes damage due to corrosion.
The FSP‟s expert report (MA) states the lack of servicing caused a blockage of
material in the heat exchanger consisting of:
zinc anode material
material which ordinarily comes from sea water.
T he applicant‟s chemical testing report states the zinc salt material was present
because of the reaction of the sacrificial zinc anode in the pump with seawater.
Whilst the panel accepts this chemical reaction is a type of corrosion (of the zinc
anode), this was planned by the engine manufacturer to protect the pump/heat
exchanger from corrosion. Given this corrosion process was intended, the panel
does not accept the FSP is entitled to rely on the exclusion for wear, tear and
corrosion in the circumstances.
Further, as already determined, the information does not establish there was a lack
of servicing of the heat exchanger.
The FSP has not established the policy exclusion for corrosion applies in the
circumstances.
The applicant‟s engineer noted that the cooling waterflow was blocked because of
residues from the anode as well as the accumulation of other deposits normally
found in water. The deposits were inside the heat exchanger and are not visible and
he would not expect service personnel to be aware of the build-up of these deposits.
As already determined, the information does not establish there was a lack of
servicing of the heat exchanger. It would appear based on the available information
the blockage was unintended and unexpected and in the circumstances the FSP has
not established the policy for corrosion applies.
FSP is unable to rely on policy exclusion
For the reasons outlined above, the panel is not satisfied that the FSP has
established that, on the balance of probabilities, the blockage in the heat exchanger
which resulted in the flooding of the boat was caused by a lack of maintenance or
corrosion.
Accordingly, the FSP is liable to settle the applicant‟s claim in accordance with the
terms and conditions of the policy. It is not in dispute the boat was left unused for
more than six months, and further damage and assessment is required to determine
the appropriate repair scope.
Upon acceptance of the determination by the applicant, the FSP is required within 30
days to re-assess the damage to determine the scope of repairs. Once obtained the
FSP is entitled to settle the claim in accordance with the terms of the policy.
Case No: 497854 Determination Page 6 of 12
2.3 Is the applicant entitled to costs claimed?
FSP required to contribute to applicant’s professional costs
Under paragraph 9.4 of the FOS Terms of Reference, FOS may require a financial
services provider to contribute to legal and other professional costs incurred by an
applicant in the course of their dispute.
The FOS process is designed to be accessible to applicants without legal
representation. Accordingly, FOS will not generally require a financial services
provider to contribute to a n applicant‟s legal costs, unless the dispute is particularly
complex or raises specific legal issues.
Further, a financial services provider will generally not be required to contribute more
than $3,000 to an applicant‟s legal costs or other professional costs unless
exceptional circumstances apply.
The applicant says he‟s incurred over $22,476 in l egal fees and $5,160 in engaging
the engineer RC.
The panel accepts that it was reasonable for the applicant to engage an engineer to
comment on the cause and extent of the damage. The detailed report from RC has
been of assistance in clarifying the cause of the loss . As indicated in the
determination, RCs report has been preferred by the panel over the opinion offered
by the FSP.
In the circumstances, the panel is satisfied the FSP should contribute $3,000 towards
the professional costs incurred by the applicant, subject to the applicant providing
valid invoices.
Case No: 497854 Determination Page 7 of 12
3 Supporting information
3.1 FOS approach to this dispute
This dispute has not been the subject of a FOS Recommendation. Due to the nature
of the dispute, it has been referred directly to a panel for Determination, in line with
the Operational Guidelines to the FOS Terms of Reference. The panel consists of an
Ombudsman and two representatives with consumer and insurance experience.
The panel has decided this case on its merits, having regard to the relevant law,
good industry practice, codes of practice and previous Financial Ombudsman
Service (FOS) decisions.
There has been a full exchanger of all material information relied on for the purposes
of this Determination and each party has had the opportunity to address any issues
raised by the other.
The panel has reviewed and considered all of the material provided by the parties.
While the parties have raised numerous issues in their submissions, for the purposes
of this Determination, the panel has restricted its commentary to those issues that it
considers directly relevant to the outcome only.
3.2 Key policy wording
Words with special meanings
To understand this Policy, You need to know what We mean by certain words. We explain
the meaning We give these important terms below:
‘Accidental Loss or Damage’ means physical loss and/or damage which occurs by
Accident.
„ Accident’ means a happening that is unforeseen and unintended by You.
…
Section 1 – Accidental Loss or Damage to Your Boat
What We cover
We will cover You for Accidental Loss, Damage, Fire and/or Explosion and Theft to Your
Boat which occurs during the Period of Insurance…
…
General exclusions
These exclusions apply to all Sections of the Policy.
…
Wear and tear
Any claim in respect of loss or damage caused by wear and tear, mould, deterioration,
vermin, corrosion, electrolysis or inherent vice.
…
Boat condition
Case No: 497854 Determination Page 8 of 12
Any claim caused by or arising as a result of the unseaworthiness, lack of repair or
maintenance of Your Boat or any Boat covered by this Policy.
…
Safeguard
Any claim for loss or damage caused by or arising as a result of the lack of reasonable
care, protection and/or security of Your Boat or any Boat covered by this Policy or other
insured property.
3.3 Key timeline
Date Action
24 - 10 - 2012 JW serviced the engine and generator .
09 - 10 - 2013 RT serviced the main engines.
10 - 10 - 2013 Applicant purchased the boat and insurance policy .
0 9 - 10 - 2014 CP serviced the engine .
Run time was noted at 742 .
08 - 01 - 2014 FM supply and install a new heat exchanger for the generator.
FM found the heat exchanger was heavily corroded inlet tail
and thick build up.
23 - 11 - 2015 MB serviced the engine and generator .
26 - 02 - 2016 HM cleaned the generator‟s heat exchanger aft er it was found
blocked by sand .
Run time was noted at 823 .
22 - 12 - 2016 HM replaced starboard temperature sensor .
31 - 12 - 2016 boat partially submerged as it pulled up to the dock at [N]
m arina. The dock master was able to pump out the water and
stemmed the inflow of water by clamping off a rubber hos e
that connected to the starboard side stern tube .
3.4 Key records
Record Key points
FSP’s assessor (MA)
Report
16 - 02 - 2017
The cause of the part ial submersion was a blockage in a
fitting in the inter cooler, which feeds water to the hose that's
connected to the shaft gland to cool it. Without the cooling
water the gland has overheated and seized on the propeller
shaft and tom itself free of the gl and hose ripping the gland
feed hose in the process.
The blockage to the gland water feed fitting was corrosion
and calcium build up in the intercooler tube st ack and end
cap. The corrosion / calcium build up is due to the lack of
service to the cooling & system.
The insured has provided service records showing the vessel
Case No: 497854 Determination Page 9 of 12
is serviced on a yearly basis.
CP 10/2014.
MB 11/ 2015
HM 2/16
None of the invoices mention service to the cooling systems,
nor do any recommend service is due to the cooling systems.
Volvo 06 service protocol recommends the Heat exchangers
and intercoolers be inspected and cleaned every 1200 hours
or five years. See attached page 65 from the Volvo operators
manual publication No 7747983 D4 D6 engines.
We discussed this with CQ , the NSW Volvo distributor/
service cent re. CQ confirmed the cooling systems on the 06
Series should be serviced at a minimum of every four to five
years.
The blockage in the gland cooling feed hose fitting, which led
to the failure of the starboard shaft gland an d the partial
submersion was caused by corrosion in the interc ooler where
the fitting is located and although the insured would not be
aware of this and has relied on his service providers.
The corrosion is caused by lack of proper maintenance to the
cooli ng system components.
Applicant’s engineer
( RC )
Report
25 - 07 - 2017
Based on my inspection of the vessel, I conclude that the
reason that water was able to enter the vessel was because
the cooling water flow to the starboard stern tube was
blocked. A blockage of that flow occurred inside the starboard
engine‟s heat exchanger and this prevented cooling water
from then flowing down a tube and into the stern tube,
I found that the reason why that cooling water flow was
blocked was becaus e of residues from the anode as well as
an accumulation of other deposits normally found in water.
These deposits are inside the heat exchanger and are not
visible.
I would not expect service pers onnel to be aware of the build -
up of the deposits in these circumstances as th ere was no
requirement for them to look inside the heat exchanger
because the engine had not accumulat ed sufficient hours to
warrant an internal inspection.
In my opinion, the consistency of the marks that I saw leads
me to strongly conclude, to an enginee ring certainty, that the
hose had wrapped around the drive shaft.
I found that the hole in the back of the heat exchanger that
ought to allow sea water to flow through the hose was
completely blocked (see Figure 6)
The opening was blocked by a white crusty deposit.
Elsewhere within the heat exchanger cover (and the
corresponding end of the heat exchanger) was more crusty
type deposit, albeit of a darker colour. I sent samples of the
white deposit and the darker deposit to the Mark Wainwright
Analytic Labora tory at the University of NW for analytic
chemical testing, and it was found that both deposits were the
Case No: 497854 Determination Page 10 of 12
same material, although the darker material contained
decomposing organic material within it, which explains the
differenc e in colour (see Appendix 3 f or the full report). In
essence, the deposit that blocked the cooling water hole
comprised the remnants of the zinc anode as well as material
which ordinarily comes from sea water.
Several comments are warranted in relation to the servicing
of the vessel. The blockage of the hole in the heat exchanger
cover is fully internal and cannot be seen unless the heat
exchanger is disassembled. The only way for a party
servicing the vessel to see the blockage (or the build up of
material) is to disassemble the heat exchanger. As such, I
would only expect a person who is servicing the vessel to
detect the problem (or the potential for a problem) if they had
a reason to look inside the heat exchanger. The maint enance
schedule fo r the engines indicates at Page 65 (see Appendix
4) that the heat exchanger should be inspected after 1,200
hours of operation.
My review of the service records for this vessel leads me to
believe that it is highly unlikely that the vessel would have
accum ulated the 1,200 hours of operation requiring an
internal inspection of the heat exchanger. As such, I am not
critical that an internal inspection was not done and therefore
I would not expect service pers onnel to see the blockage (or
the developing blocka ge). The last time the vessel was
serviced was on 26 February 2016 by HM , and the engine
hours were noted to be around 823 hours, well short of the
1,200 hours at which an internal inspection was
recommended.
I can appreciate that there is mention of a hea t exchanger
being blocked by sand but the document that reports this
(Tax Invoice of HM dat ed 26 February 2016) mentions the
word “Onan”, which is a diesel manufacturer that makes
generators and is quite distinct from the name of the engine
manufacturer, w hich is Volvo Penta. That is, the sand
blockage was in the generat or and not the main diesel
engines.
Moreover, if there was a sand blockage in the main diesel
engine cooling circuit, then I would expect elevated engine
temperatures to result. The engine c oolant temperature is
displayed on the instrument panel and if there was an issue
with the coolant circuit, I would expect a competent skipper to
be aware of it. There is no mention of elevated engine
temperatures within the material available to me. As su ch, I
conclude that in all likelihood, there was no sand issue in the
main engine coolant circuits and so I would not expect a
competent repairer, coming to deal wit h the sand blockage in
the generator, to look in the main engines.
One final comment is war ranted that follows on from the fact
that the blockage that started the water ingress was internal
to the starboard heat exchanger. As I noted above, because
Case No: 497854 Determination Page 11 of 12
the blockage was internal I would not expect service
personnel to have seen it. It also follows th at I would not have
expected personnel using the vessel to have seen it.
Moreover, unless there was some form of high temperature
issue with the starboard engine, I would not expect a person
using the boat to be prompted to look further. My reading of
the available material is that there is no mention of an
overheating issue with the starboard engine (around that
time), and as such I would not expect the people using the
boat to be aware of the developing issue inside the starboard
engine‟s heat exchanger. In all likelihood, the developing
problem of the build - up of the crusty deposit within the
starboard heat exchanger was undetectable until it
manifested the issue inside the starboard stern tube, in my
opinion.
Solid deposit analysis
(UN)
Report
16 - 06 - 2017
On 12th June 2017, a water pump was delivered to UW for
inspection and sampling. On the salt water cooling side of the
pump a water - line of white crystalline solid was evident as a
tide mark together with darker crystalline material at the lower
pump level.
Samples were taken from the white and dark crystalline
materials and it was not ed at the time that the dark material
was virtually identical to the white crystalline mat erial when
the dark surface was removed.
White crystalline deposit - The w hit e crystalline deposit
consisted mainly of zinc salts, zinc oxide, zinc hydroxide,
hydrated zinc chloride and zinc sulphate but also contained
magnesium hydroxide, silica, calcium sulphate (gypsum) and
calcium carbonate. The zinc salts would have origina ted from
the reaction of the sacrificial zinc anode in the pump with
seawater. The calcium carbonate and calcium sulphat e are
natural substances found in fres h water and sea water.
Dark crystalline deposit - The dark crystalline deposit also
consisted main ly of zinc salts, zinc oxide, zinc hydroxide,
hydrated zinc chloride and zinc sulphate and also contained
silica, calcium sulphate (gypsum) and calcium carbonate. The
deposit however was darkened by the presenc e of decayed
organic matter mainly on the surf ace of the deposit.
Manufacturer manual
(VO)
Maintenance schedule
Every 1200 hours / at least every 5 years
Heat exchanger. Inspect/Clean
Intercooler. Inspect/Clean
FSP’s assessor (MA)
Letter
10 - 08 - 2017
Marine engines require regular maintenance of their cooling
systems. Volvo Penta recommends the heat exchanger and
intercoolers on a 06 engine be serviced at least every
1200hrs or 5 - years.
RC in answering this question seems to only consider the
1200hrs recommendation. RC also states he would only
expect a pers on who is servicing the vessel to detect a
problem or the potential for a problem if they had a reason to
Case No: 497854 Determination Page 12 of 12
look inside the heat exchanger. I strongly disagree with RC
comment. Volvo Penta's recommendation of
service/inspection of the heat exchanger an d intercooler at
least every 1200hrs or 5 - years is very import ant to prevent
failure.
Adhering to the 5 - year recommendation is very important as
corrosion and the build - up of deposits still occur even if the
motor is not run. As stated in my report dat ed 1 6t h February
2016 none of the service records provided by the insured
showed any service to or recommendation to service the heat
exchangers or intercoolers. At 8 - years of age the heat
exchangers and intercoolers would definitely need inspection.
Sand in t he gens et heat exchanger has nothing to do with this
casualty.
I would agree wit h RC that most boat owners would not be
aware of developing issues inside marine engine heat
exchangers or intercoolers and rely to an extent on the
service provider to carry out the correct servicing of his
vessel, However it is the owners responsibility to e nsure his
vessel is serviced correctly and regularly.
FSP’s assessor (MA)
Email
24 - 08 - 2017
The volvo service manual doesn't go into detail. On page 65 it
recommends to inspect and clean at 1200 hours or 5 years.
To clean thes e assembles you can run a desc aling fluid
through them or dismantle them. I would recommend
dismantling.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.