Text of the determination
Determination
Case No: 497650 Determination Page 1 of 8
Case number: 497650 25 July 2018
1 Overview
1.1 Dispute
On 13 May 2016, the applicant lodged a claim with the financial services provider
(FSP) for storm damage sustained to his tank/foundation wall, and for other damage
caused by the escape of water from the tank.
The FSP assessed the damage and indemnified the applicant for the resulting
damage to contents, but denied cover for the water tank/wall. This was on the basis
that the FSP’s engineer had concluded the cause of the damage to the tank/wall was
gradual deterioration, which is excluded under the policy.
The applicant disagrees. He believes the storm was the proximate cause of the
damage, and that repair of the tank/wall should be fully covered.
1.2 Issues and key findings
Is the FSP entitled to partially deny the claim?
The FSP is not entitled to fully deny the claim for the damaged building.
That is because the failure of the tank/wall would not have happened if it were not for
pre-existing defects and faults, which the applicant could not reasonably have known
about.
It was those defects which caused the progressive deterioration and corrosion, that in
turn made the structure vulnerable to the storm event and led to the additional
sudden damage and escape of liquid from the tank.
The policy does not cover the cost of repairing/replacing the item from which the
liquid escaped (the tank itself). However, the FSP is responsible for the damaged
foundation wall and other affected parts of the building.
1.3 Determination
This determination is partially in favour of the applicant.
The FSP is required to settle the claim for accidental damage to the applicant’s wall
in accordance with the remaining policy terms and conditions, but it is not required to
repair/replace the water tank itself.
Case No: 497650 Determination Page 2 of 8
2 Reasons for determination
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions.
I have taken into account all the material submitted by the parties, both before and
after the recommendation. I am satisfied that the documentation I have relied on has
been provided to both parties.
2.1 Is the FSP entitled to partially deny the claim?
Prima facie claim for accidental damage from storm and escape of liquid
On 13 May 2016, the applicant’s broker lodged a claim following a storm event. The
applicant said water escaping from the failed tank/foundation wall caused damage to
parts of the house, as well as to contents. (The damaged side of the applicant’s
water tank also serves as the load-bearing wall to the basement of the property.)
I am satisfied the applicant has shown there was accidental damage to the property
following the storm, with water escaping from the tank into his home. The policy
covers accidental damage from ‘storm’ and ‘escaping liquid’, subject to certain
conditions and exclusions. The FSP paid part of the claim (for damaged contents) on
that basis.
So, the applicant has established, on balance, he has a prima facie claim under the
policy. It is then for the FSP, in declining the rest of the claim, to demonstrate on the
balance of probabilities, the cause of the disputed damage was a factor the policy
excludes, or that it is otherwise entitled to do so.
Need to establish the proximate cause of the damage
In determining whether an exclusion applies, it is necessary to identify the proximate
cause of the damage. This is a question of fact depending upon the circumstances of
each case.
A proximate cause is not necessarily the first or last or the sole cause of the loss: it is
the effective or dominant or operative cause. There may also be circumstances
where several causes operate contemporaneously. In that case, each must be
examined for the qualities of predominance and efficiency as the active efficient
cause that sets a relevant train of events in motion.
The courts have said that if one cause would have resulted in the harm in any case
and the other would not have done so in the absence of the first, then the first is the
proximate cause.
Proximate cause of damage was defects, structural faults or design faults
The FSP’s expert, KW, identified recent cracking, corrosion, and a small area of
previous patching when he inspected the property some months after the storm
event. KW said that even though there was no visible or obvious seepage from the
tank as viewed from within the building itself, moisture penetration at the floor/wall
junction had been occurring over a very long period of time.
Case No: 497650 Determination Page 3 of 8
However, KW’s report clearly attributes the tank’s failure to ‘initial construction
detailing’, including:
insufficient waterproofing at construction joints as water has been penetrating
the walls over a long period of time
insufficient or incorrect reinforcement to accommodate normal in-service
stresses (including the wire mesh at the floor/wall junction)
insufficient thickness of the affected wall
the fact that the tank was never designed for a 7.3m long wall.
KW described the reinf orcement design and detailing of the wall as ‘grossly
inadequate’.
On the available evidence, I am satisfied, on balance, that the pre-existing defects
and faults with the construction of the water tank were the proximate cause of the
damage. In other words, if it were not for those defects and faults, it is more likely
than not that neither the long-term escape of water, nor the sudden failure during the
storm, would have occurred.
General exclusion for gradual deterioration, corrosion does not apply
The FSP has relied specifically on the general policy exclusion for gradual
deterioration and corrosion in declining the claim; and KW’s report did refer to the
heavily corroded wire as leading to the separation of the base slab from the wall. The
applicant also submits the reason ‘the joint [between the tank and foundation wall]
failed is because the steel mesh in the middle of the concrete over a long period of
time rusted’. He says all the water came through that ‘bottom floor wall joint’.
However, I do not consider this represents the ‘ gradual deterioration ’ or wear and
tear which might reasonably be expected in the normal course of use of the tank for
its intended purpose, and which the exclusion is intended to address . Instead, I am
satisfied the evidence shows the identified corrosion and failure of the corroded wire
was itself the result of the underlying defects or faults identified by KW.
So the FSP is not entitled to decline the claim on the basis of the general exclusion
for gradual deterioration, corrosion and wear and tear.
General exclusion for defect, structural fault or design fault does not apply
I acknowledge that there is also a general exclusion for ‘ defect, structural fault or
design fault ’ . However, that is explicitly qualified to apply where the insured knew
about or should reasonably have known about the fault.
In this case, the applicant maintains that he could not have reasonably known about
the impending tank failure or the defects in construction or design identified by KW.
KW ’s report supports that contention, specifically confirming:
the applicant would have been unaware of the impending tank failure
the failure was sudden and without warning
lack of visual water seepage to the wall is not evidence the waterproof
membrane had been performing effectively.
Case No: 497650 Determination Page 4 of 8
In the circumstances, I am not persuaded that exclusion applies to allow the FSP to
decline the claim, since the evidence does not show the applicant knew or should
reasonably have known about the issues with the tank.
Exclusion for escaping liquid does not apply
There is a further exclusion which applies specifically to damage from ‘escaping
liquid’. Again however, that is limited to situations of wear and tear, or to damage
from a ‘gradual process…over a period of ti me when [the insured] could reasonably
be expected to be aware of this condition’.
For the reasons given above, I do not consider that this was a case of normal wear
and tear, nor does the evidence show the applicant could reasonably have been
aware of the ongoing problem. The exclusion does not apply in the circumstances.
FSP is not entitled to fully decline the claim for damage to the building
The FSP has not established exclusions apply to entitle it to fully decline the disputed
parts of the claim.
That means it must settle the claim, in accordance with the policy terms and
conditions, for the building damage (including to the foundation wall) which occurred
from the progressively escaping water from the tank, as well as suddenly from the
storm.
However, that does not include an obligation to repair or replace the water tank itself.
That is because the policy cover for ‘escaping liquid’ specifically excludes ‘the cost of
repairing or replacing the item from which the liquid escaped’.
Case No: 497650 Determination Page 5 of 8
3 Supporting information
3.1 Expert reports
Record Key points
FSP’s Engineer’s report 1
( KW )
26 - 10 - 2016
The purpose of the visit was to inspect and report in the cause(s )
of the damage to an underground concrete water tank and to
comment on whether the struct ural int egrity of the dwelling has
been compromised.
The tank was empty at the time of our inspection and access was
available via a 550 mm square manhole in the verandah slab.
It appeared that the tank has been poured in - situ during
construction of the dwelling.
A liquid membrane had been applied to the int ernal walls and
floor of the tank.
Distress to the southern wall consisted of:
Lateral bowing/movement to the south with a separation
from the bas e slab
Heavily corroded reinforcement wire was clearly visible at
the wall/ floor junction. There were no dedicated starter bars
tying the wall and floor slab together.
Recent diagonal cracking from either end of the wall was
observed, starting at floor level and rising to continuous
horizontal crack.
There wer e areas of past patching and repairs to the liquid
membrane.
It appeared that wash out of base material had occurred
during the sudden escape of water
Groups of recent diagonal cracking from either end of the
wall were observed
There was no obvious evidenc e of long term seepage from the
tank walls as viewed from within the workshop however a small
area of patching was noted.
The tank floor was relatively level and the tank did not appear to
have been affected by uplift from buoyancy forces.
There was no obvious defects to the permitter block walls at
basement level.
The reinforcement tying the base slab to the walls of the wat er
tank was heavily corroded.
Although there was little (or no) visible seepage from the tank, it
was now obvious that moisture pen etration at the wall/floor
junction had been occurring over a very long period of time.
There was no water - stop or sealing detail at this joint as would
be considered normal practice for a water tank.
It appeared that the light mesh reinforcement from the base slab
has been upt urned at slab edges in lieu of using dedicated cast -
in starter bars such as N12 L bars.
Failure to install starter bars to tie the walls and slab together has
ultimately resulted in the failure of the tank due to the more rapid
Case No: 497650 Determination Page 6 of 8
corros ion of light mesh.
If N12 L bars with 600mm legs had been cast into the base slab
at 400 mm centres as would be considered common practice for
an in ground tank of this type, then it is likely that the observed
failure would not have occurred.
Lightly rein forced thin walled rectangular tanks of this type would
normally be buried with the surrounding fill material restraining all
four sides
The lateral load of the external substrate would generally provide
a reactive force against the weight of water, in add ition to
increased loads from sudden changes in water level.
In this case, the southern side of the tank formed the rear wall of
the basement workshop.
There was no reactive force from the surrounding substrate to
resist the sudden rise in water level duri ng nominated storm
event.
The sudden additional lateral load from the rapidly rising water
against the tank wall has caused the heavily corroded wire
reinforcement tying the walls and floor to fail, leading to the
observed separation and the sudden egress of water from the
tank.
We are of the opinion that the observed failure was due to initial
construction det ailing such as, but not limited to:
Insufficient water - proofing at construction joints. It appeared
that water has been penetrating the wall/floor junction over a
very long period of time.
Insufficient and/or incorrectly placed reinforcement to
accommodate the stresses generated by normal in - service
tensile stresses. It appeared that the stresses generated by
normal in - servic e tensile stresses. It ap peared that the
southern wall of the tank was only lightly reinforced.
In addition, the wall/ floor junction had been tied using
upturned wire mesh. It appeared that reinforcement design
and detailing of the southern wall was grossly inadequate,
Insufficien t thickness of the sout hern wall to accommodate
the stresses generated by normal in service tensile stresses.
It is likely that the insured was unaware of the impending tank
failure. We would consider the failure to have been sudden and
without warning.
F SP’s Engineer’s report 2
( KW )
13 - 01 - 2017
As stated in our report, we agree that the Insured would have
been unaware of the impending tank failure. We would consider
failure to have been sudden and without warning
Seepage was not visible as the wall / floor j unction of the tank was
below the level of the garage slab. We would not consider the
lack of visual indicators prior to failure to be evidence that the
liquid membrane within the tank had been performing effectively.
The upturned mesh tying the base slab to the walls of the water
tank was heavily corroded. It was obvious that moisture
penetration at the wall/ floor junction had been occurring over a
very long period of time. We would consider the level of
Case No: 497650 Determination Page 7 of 8
oxidati on/ corrosion of the mesh to be very advanced, far in
excess of that expected from 8 months in a relatively enclosed
environment.
We would not consider the tank to meet the building standards of
the day. Comprehensive Australian Standards relating to
concrete design and structural design actions were us ed by
Engineers at the time of construction.
Lightly reinforced, thin walled rectangular tanks of this type would
normally be buried with the surrounding fill material restraining all
four sides. The lateral load of the external substrate would
generally provide a reactive force against the weight of water, in
addition to increased loads from sudden changes in water level.
The fact that there was absolute minimal reinforcement tying the
base slab to the walls would indicate that this tank was never
design ed for a 7.3m long unsupported longitudinal wall as was
the case in this instance.
There was no reactive force from the surrounding substrate
acting upon the unsupported longitudinal wall to resist the
sudden rise in water level during the nominated storm event.
Corrosion of the reinforc ement mesh ultimately resulted in a
reduction in capacity of the already undersized ties.
On the day of the event , the corroded ties at the wall/ floor
junction did not have sufficient capacity to accommodate the
dynamic load of the rapidly rising water.
The sudden additional lateral load from the rising water against
the tank wall ultimat ely caused the wire mesh tying the walls and
floor to fail, leading to the observed separation and the sudden
egress of water from the tank.
Applicant’s builder email
(TJ)
25 - 06 - 2016
The cause of the damage to the water tank is the volume of
water due to massive storm
The pressure from the water caused the tank to crack
3.2 Relevant policy terms
General exclusions
Defect, structural fault or design fault
A defect, structural fault or design fault that you knew about (or should reasonably
have known about) and did not fix before the loss or damage occurred… (my
underlining)
Case No: 497650 Determination Page 8 of 8
Wear, tear and gradual deterioration
Wear, tear, rust, fading, rising damp, mould, mildew, corrosion, rot, action of light or
gradual deterioration…
Exclusion for ‘ Escaping liquid ’
wear and tear, or loss or damage by the escaping liquid occurring as a result of
a gradual process of leaking, splashing, dripping or overflowing over a period of
time when you could reasonably be expected to be aware of this condition (my
underlining)
the cost of repairing or replacing the item from which the liquid escaped.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.