Text of the determination
Determination
Case No: 496069 Determination Page 1 of 8
Case number: 496069 4 May 2018
1 Overview
1.1 Dispute
The applicant lodged a claim with the financial services provider (FSP) for „Escape of
liquid‟ that caused cracking and uneven floor levels to his home.
The FSP denied the claim on the basis of a number of policy exclusions. This
included earth movement.
1.2 Issues and key findings
Is the FSP liable for the movement damage to the applicant’s home?
The FSP is not liable for the movement damage because the evidence shows it was
caused by earth movement associated with existing site conditions. This falls within
the policy exclusion for earth movement.
Is the applicant entitled to reimbursement of professional fees?
The report provided by the applicant‟s engineer did not advance his position.
Therefore, the FSP is not required to contribute to the costs of this report.
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitled to deny liability for the claim and is not required to contribute to
the costs of the applicant‟s engineer‟s report.
Case No: 496069 Determination Page 2 of 8
2 Reasons for determination
2.1 Is the FSP liable for the movement damage to the applicant’s home?
Policy provides cover for resulting damage subject to exclusions
These relevant facts are not in dispute:
the property is about 100 years old and has an addition at the rear (northern)
aspect which is about 30 to 35 years old
an extensive leak was discovered under the driveway
the driveway was adjacent to the western side of the property
The applicant says this leak caused the damage being claimed. The FSP disputes
this and says the damage is related to foundation movement associated with poor
drainage and other factors.
In support of their respective positions, the parties have provided an opinion from an
engineer (JC and JS). Their opinions have been summarised in section 3.1.
In addition, the FSP has provided numerous other reports. However, these opinions
were provided prior to the discovery of the extensive leak at the driveway.
JC’s evidence is preferred
Having carefully reviewed the engineering reports, and taking into account all of the
other evidence, I prefer JC‟s report for the following reasons.
First, and of significance, JC noted it would be reasonable to expect the damage to
be more extensive to the area proximate to the leak. It is not. Instead, the more
extensive damage is further away.
JC‟s argument is plausible and logical. JS does not address this anomaly in his
report.
Second, both JC and JS accept there are poor drainage issues affecting the subfloor.
JS noted the drainage at the south-western wall was particularly poor. The extensive
damage is proximate to this part of the home. This poor drainage would readil y
explain the abnormal moisture conditions being sustained to the area of extensive
damage. JS does not explain why this is not the case.
Third, there is no dispute the property has been subject to pre-existing movement
issues. Previous cracks were identified with filling along with evidence of sub-floor
work. This shows the property is subject to foundation movement over its history.
Given all this, I accept the FSP has shown on the balance of probabilities that the
damage to the property was caused by earth movement associated with existing site
conditions. This falls within the policy exclusion for earth movement.
Therefore, the FSP is entitled to deny liability for the applicant‟s claim.
Case No: 496069 Determination Page 3 of 8
2.2 Is the applicant entitled to reimbursement of professional fees?
FSP is not required to reimburse applicant ’ s engineer’s report
The applicant engaged an engineer to assist him and is seeking reimbursement of
the cost of this report.
Pursuant to paragraph 9.4 of the FOS Terms of Reference, FOS may require an FSP
to contribute to professional costs incurred by an applicant in the course of their
dispute.
However, I note:
the FSP‟s position was substantiated by way of an engineer‟s report
the applicant‟s engineer did not advance his position
Given this, I do not accept the FSP is required to contribute to the costs of the
applicant‟s engineer‟s report.
Case No: 496069 Determination Page 4 of 8
3 Supporting information
3.1 Expert Reports
Record Key points
Leak Test
Report
Unknown Date
Details of te sts conducted
Test 1: Nitrogen tested hot water line - PASS
Test 2: Nitrogen tested cold water line - FAIL
Test 3: Dye tested shower base - PASS
Test 4: Flood tested shower walls - FAIL
Test 5: CCTV inspected sewer - FAIL
Conclusion
We carried out a leak detection test to the whole house to find the
cause of cracking alon g the walls of the rear living room and
bathroom.
There had previously been a burst galvanis ed cold water service
under the concrete driveway at the northern rear corner of the house,
which was repaired in August 2016. The insured believes this to be
the main cause of all the cracking.
We nitrogen tested the hot water line, which passed the test. When
we nitrogen tested the cold water it failed the test due to the
connection of the plastic water service that the insured has renewed,
and the old water serv ice.
We believe it is also very likely that the galvanised water service may
also be weeping along the driveway side of the house because it is in
poor condition. We would recommend all of the galvanised pipe work
to be renewed.
When we flood tested the shower, we found large amounts of water
to leak out and under the flooring of the living room. It appears there
is no waterproofing or there is badly damaged wat erproofing.
There is floor/ wall separation throughout the whole bat hroom. We
CCTV inspected th e sewer and found a poor connection between the
PVC coming from under the bathroom and joining into the gully in the
driveway.
We also found a cracked joint 1.5m towards the rear from the gully,
and a badly cracked section of pipe on the northern rear cor ner,
which is in the same position as the previous burst water pipe. This
section of pipe is 100mm earthenware.
The ground level surrounding the house is higher than under the
house. There are gaps between the driveway and the house where
water would flow under the house during heavy rain, even though the
driveway does fall away from the hous e.
There are many cont r ibuting factors causing moisture under the
house, making it difficult to say the exact cause of the cracking, or
whet her it was movement first causing the cracking to the other
services.
Case No: 496069 Determination Page 5 of 8
FSP’s Engineer (JC )
Report
28 August 2017
“ A large native tree at th e front yard was removed some years
ago … – The moisture suction of soils varied, especially considering
the site is clay reactive site, the upward heaves and downward
settlements of the site especially on the front yard area will be
affected significantly.”
“ Assuming the driveway was built roughly the same time to the
addition built ont o the rear aspect of the building, or before the
addition was built, we are of the opinion that seepage occurred and
inappropriate construction practices. … the water has a di fficult
time to dry up from the collected point (sub - floor) and causing
damage to the living room area outside the bat hroom. However,
with adequate ventilation at the subfloor area, this issue can be
minimised or rectified, through our inspection around the house, it
can be noted that on the rear side of the dwelling (east), and the
side (north) of the dwelling, they are both covered in concrete
driveway and brick paving. Additionally, there are no visible
vent ilation for the sub - floor found throughout the dwelling. It should
be not ed that during the inspection, the subfloor was still wet,
although the Insured claim they haven‟t used the shower recently.
We are of the opinion that the water ingress was caused by the
rain, inadequate stormwater system, and inappropriat e fini sh floor
level of the dwelling. ” …
“ Additionally, we believe the design of the foundation of the whole
premises was poorly carried out or defective as the sub - floor level
of the dwelling is lo wer than the external ground finishes
(pavement, existing driveway fill and soil / garden), or possibly the
fill causing water seepage to occur, which ultimat ely leads to the
whole premises to the building footprint to perform as a stormwater
collecting sp ot. Water seeping under the dwelling, the addition area
settling and the lack of ventilation are a combination of issues
which would not permit moisture to escape the sub - floor area. The
combination of these factors has prompted the cracks to occur. .. . ”
C onclusion
With our visual soil inspection and desktop researches, it can be
concluded that this site has a mix of fill soil and reactive clay soil,
however, majority of the layered soils are evidently moderate to
high reactive soils, therefore, with a poor drainage system or
stormwat er system or ventilation system, damage to the dwelling
are inevit able.
The cause of the alleged damage occurred to the rear side of the
dwelling, support ed by the engineering documentation explanation,
and as discussed in Sect ion 4, we are strongly of the opinion that
the main factor of the damage was due to the reactive soil swelling
at the internal and at the rear of the premis es.
We are of the opinion that the pipe leak age would cause more
severe damage in the bedroom area compared to the family
area/bar area, as the water seeping into the bedroom area first
before seeping into the family area/bar, especially from all the
evidence and proof, however this is not the case, therefore again,
we are of the opinion that the damage occurred in the family
Case No: 496069 Determination Page 6 of 8
area/bar is not consistent with the Insured‟s suggested event, pipe
leaking, as per professional information provided, discussion
above, Australian Standards, and or supported findings.
We are of the opinion that there has always b een a
foundation/movement issue on site, supported by several
photographic and vis ual evidences found on site, as discussed
above.
We are at opinion that the site was filled during the
renovation/addition and the bedding/back - filling process were not
pref ormed appropriately or was done poorly, therefore, causing
seepage/ water ingress under the dwelling to occur on site.
The possible events suggested by the Insured, Earthquake and
pipe leakage, would not have caused the existing cracking
damage … We are of the opinion that these damages / cracking
has been caused by poor, dated, or defective design / construction,
ground/soil movement, and water seepage.
The inconsistency of the relationship bet ween water leak and the
critical damage area of the dwelling is illustrated in diagram 5 and
on the Google Maps Image below.
Applicant’s Engineer ( JS )
Report
17 November 2017
Although the structural integrity of the dwelling was considered
sound the observed defects as noted at the time of the inspection
were deemed consistent with foundation movement induced by
shallow footings being founded on highly reactive soils, with thes e
soils being subjected to abnormal moisture conditions namely the
leakage of the adjoining pipework. The dwelling overtime has been
subjected to foundation movement with evidence of this noted from
previous repairs undertaken. However, the leaking pipewor k has
induced an abnormal moisture condition within the soil stratum and
this continual wetting that has seen a greater swelling of the soils
than normal to occur thus increasing the frequency and size of the
defects as noted. From experience with these lo cal soils, the
ongoing wetting induced by the leak would have extend over a
large area and at depth thus increasing the "depth of suction
charge".
On review of our observations at the time of the inspection, the
probable cause of the damage in our opinion is a direct result of:
On - going saturation of soil stratum to the dwelling cause by the
leaking pipework. Although the dwelling would be subject to
foundation movement induced by typical weather patterns which
would induce cracking, the leaking pipe has i nduced an abnormal
moisture conditions thus increasing the size and frequency of the
cracking as noted.
The oversaturation of the soils toward the south - west corner of the
dwelling induced by the leaking pipe has caused the foundation
soils to "soften" hen ce reducing the bearing stressed under the
isolated pads. This loss of bearing capacity has led to excessive
settlement in the isolated piers and thus the sagging and bounce
noted to timber floor along the western wall.
Other contributing factors in our op inion are:
Poor sub - floor ventilation. It was noted on site that the sub - floor
Case No: 496069 Determination Page 7 of 8
clearance was generally between 200 - 400mm which is less than
the BCA requirements. Adequate cross ventilation is critical to
ensure the subfloor required dry. The low clearanc e also means
that the required 50mm fall over 1000mm as required by AS2870 -
2011 "Residential Slabs & Footings" is difficult to achieve.
Shallow footings founded on reactive soils. Although the foundation
depth is unknown, the age of the dwelling would su ggest that the
isolated footings are shallow. Shallow footings provide poor
serviceability in reactive soils especially when subject to abnormal
moisture conditions.
3.2 Policy Wording
3 General exclusions
Your policy does not cover any loss or damage that is caused by or arises from:
Maintenance and building
o defects in design, structure, materials, workmanship or construction
o failure to keep the property insured watertight, well maintained, structurally sound
and secure. …
Wear and tear, and environmental conditions.
o wear and tear, gradual deterioration, or fading,
o …
o earth or soil movement (other than earthquake) including landslide, subsidence,
or erosion
o settling, expansion, shrinkage or vibration
4.3 Insured events (Building and Contents)
Insured events
… we will insure your building and/or contents at the site against loss or damage caused by
the following events if they occur during your period of insurance.
…
Escape of liquid
Covered
Loss or damage caused by accidental escape of liquid from any fixed pipe, fixed tank,
waterbed, fish tank, or fixed item used to hold liquid.
We will also pay reasonable exploratory costs in locating the source of the damage,
provided we have agreed to pay for the loss or damage caused by the escape of liquid.
Not Covered
loss or damage to the item from which the liquid escaped, and if the liquid escaped
from a shower recess, the cost of re-tiling the walls or floor of the shower recess.
repair or replacement of undamaged parts of your contents to match property tha t
has been repaired or replaced
loss or damage caused by gradual escape of liquid which is evident and which you
fail to rectify.
Case No: 496069 Determination Page 8 of 8
Accidental loss or damage
Covered
Accidental loss or damage to:
• your building and/or contents at the site, or
…
If loss or damage is caused by any other insured event, you must claim under that section
of your policy.
For every claim we agree to pay, your excess will be the greater of your basic excess or
$300.
Not covered
Any loss or damage excluded under any insured events, unless otherwise stated.
…