Determination 496069

Earth movement exclusion for property damage

FirmFinancial Firm (Unknown - Insurer)
Decided2018-05-04
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for cracking and uneven floors after a water leak under his driveway, and the FSP denied the claim under the earth movement exclusion. AFCA preferred the FSP's engineer, found the damage was caused by site movement, and declined reimbursement of the applicant's engineering report costs.

The insurer proved on the balance of probabilities that the damage fell within the earth movement exclusion, based on the engineering evidence and pre-existing movement.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 496069 Determination Page 1 of 8 Case number: 496069 4 May 2018 1 Overview 1.1 Dispute The applicant lodged a claim with the financial services provider (FSP) for „Escape of liquid‟ that caused cracking and uneven floor levels to his home. The FSP denied the claim on the basis of a number of policy exclusions. This included earth movement. 1.2 Issues and key findings Is the FSP liable for the movement damage to the applicant’s home? The FSP is not liable for the movement damage because the evidence shows it was caused by earth movement associated with existing site conditions. This falls within the policy exclusion for earth movement. Is the applicant entitled to reimbursement of professional fees? The report provided by the applicant‟s engineer did not advance his position. Therefore, the FSP is not required to contribute to the costs of this report. 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny liability for the claim and is not required to contribute to the costs of the applicant‟s engineer‟s report. Case No: 496069 Determination Page 2 of 8 2 Reasons for determination 2.1 Is the FSP liable for the movement damage to the applicant’s home? Policy provides cover for resulting damage subject to exclusions These relevant facts are not in dispute:  the property is about 100 years old and has an addition at the rear (northern) aspect which is about 30 to 35 years old  an extensive leak was discovered under the driveway  the driveway was adjacent to the western side of the property The applicant says this leak caused the damage being claimed. The FSP disputes this and says the damage is related to foundation movement associated with poor drainage and other factors. In support of their respective positions, the parties have provided an opinion from an engineer (JC and JS). Their opinions have been summarised in section 3.1. In addition, the FSP has provided numerous other reports. However, these opinions were provided prior to the discovery of the extensive leak at the driveway. JC’s evidence is preferred Having carefully reviewed the engineering reports, and taking into account all of the other evidence, I prefer JC‟s report for the following reasons. First, and of significance, JC noted it would be reasonable to expect the damage to be more extensive to the area proximate to the leak. It is not. Instead, the more extensive damage is further away. JC‟s argument is plausible and logical. JS does not address this anomaly in his report. Second, both JC and JS accept there are poor drainage issues affecting the subfloor. JS noted the drainage at the south-western wall was particularly poor. The extensive damage is proximate to this part of the home. This poor drainage would readil y explain the abnormal moisture conditions being sustained to the area of extensive damage. JS does not explain why this is not the case. Third, there is no dispute the property has been subject to pre-existing movement issues. Previous cracks were identified with filling along with evidence of sub-floor work. This shows the property is subject to foundation movement over its history. Given all this, I accept the FSP has shown on the balance of probabilities that the damage to the property was caused by earth movement associated with existing site conditions. This falls within the policy exclusion for earth movement. Therefore, the FSP is entitled to deny liability for the applicant‟s claim. Case No: 496069 Determination Page 3 of 8 2.2 Is the applicant entitled to reimbursement of professional fees? FSP is not required to reimburse applicant ’ s engineer’s report The applicant engaged an engineer to assist him and is seeking reimbursement of the cost of this report. Pursuant to paragraph 9.4 of the FOS Terms of Reference, FOS may require an FSP to contribute to professional costs incurred by an applicant in the course of their dispute. However, I note:  the FSP‟s position was substantiated by way of an engineer‟s report  the applicant‟s engineer did not advance his position Given this, I do not accept the FSP is required to contribute to the costs of the applicant‟s engineer‟s report. Case No: 496069 Determination Page 4 of 8 3 Supporting information 3.1 Expert Reports Record Key points Leak Test Report Unknown Date Details of te sts conducted Test 1: Nitrogen tested hot water line - PASS Test 2: Nitrogen tested cold water line - FAIL Test 3: Dye tested shower base - PASS Test 4: Flood tested shower walls - FAIL Test 5: CCTV inspected sewer - FAIL Conclusion We carried out a leak detection test to the whole house to find the cause of cracking alon g the walls of the rear living room and bathroom. There had previously been a burst galvanis ed cold water service under the concrete driveway at the northern rear corner of the house, which was repaired in August 2016. The insured believes this to be the main cause of all the cracking. We nitrogen tested the hot water line, which passed the test. When we nitrogen tested the cold water it failed the test due to the connection of the plastic water service that the insured has renewed, and the old water serv ice. We believe it is also very likely that the galvanised water service may also be weeping along the driveway side of the house because it is in poor condition. We would recommend all of the galvanised pipe work to be renewed. When we flood tested the shower, we found large amounts of water to leak out and under the flooring of the living room. It appears there is no waterproofing or there is badly damaged wat erproofing. There is floor/ wall separation throughout the whole bat hroom. We CCTV inspected th e sewer and found a poor connection between the PVC coming from under the bathroom and joining into the gully in the driveway. We also found a cracked joint 1.5m towards the rear from the gully, and a badly cracked section of pipe on the northern rear cor ner, which is in the same position as the previous burst water pipe. This section of pipe is 100mm earthenware. The ground level surrounding the house is higher than under the house. There are gaps between the driveway and the house where water would flow under the house during heavy rain, even though the driveway does fall away from the hous e. There are many cont r ibuting factors causing moisture under the house, making it difficult to say the exact cause of the cracking, or whet her it was movement first causing the cracking to the other services. Case No: 496069 Determination Page 5 of 8 FSP’s Engineer (JC ) Report 28 August 2017  “ A large native tree at th e front yard was removed some years ago … – The moisture suction of soils varied, especially considering the site is clay reactive site, the upward heaves and downward settlements of the site especially on the front yard area will be affected significantly.”  “ Assuming the driveway was built roughly the same time to the addition built ont o the rear aspect of the building, or before the addition was built, we are of the opinion that seepage occurred and inappropriate construction practices. … the water has a di fficult time to dry up from the collected point (sub - floor) and causing damage to the living room area outside the bat hroom. However, with adequate ventilation at the subfloor area, this issue can be minimised or rectified, through our inspection around the house, it can be noted that on the rear side of the dwelling (east), and the side (north) of the dwelling, they are both covered in concrete driveway and brick paving. Additionally, there are no visible vent ilation for the sub - floor found throughout the dwelling. It should be not ed that during the inspection, the subfloor was still wet, although the Insured claim they haven‟t used the shower recently. We are of the opinion that the water ingress was caused by the rain, inadequate stormwater system, and inappropriat e fini sh floor level of the dwelling. ” …  “ Additionally, we believe the design of the foundation of the whole premises was poorly carried out or defective as the sub - floor level of the dwelling is lo wer than the external ground finishes (pavement, existing driveway fill and soil / garden), or possibly the fill causing water seepage to occur, which ultimat ely leads to the whole premises to the building footprint to perform as a stormwater collecting sp ot. Water seeping under the dwelling, the addition area settling and the lack of ventilation are a combination of issues which would not permit moisture to escape the sub - floor area. The combination of these factors has prompted the cracks to occur. .. . ” C onclusion  With our visual soil inspection and desktop researches, it can be concluded that this site has a mix of fill soil and reactive clay soil, however, majority of the layered soils are evidently moderate to high reactive soils, therefore, with a poor drainage system or stormwat er system or ventilation system, damage to the dwelling are inevit able.  The cause of the alleged damage occurred to the rear side of the dwelling, support ed by the engineering documentation explanation, and as discussed in Sect ion 4, we are strongly of the opinion that the main factor of the damage was due to the reactive soil swelling at the internal and at the rear of the premis es.  We are of the opinion that the pipe leak age would cause more severe damage in the bedroom area compared to the family area/bar area, as the water seeping into the bedroom area first before seeping into the family area/bar, especially from all the evidence and proof, however this is not the case, therefore again, we are of the opinion that the damage occurred in the family Case No: 496069 Determination Page 6 of 8 area/bar is not consistent with the Insured‟s suggested event, pipe leaking, as per professional information provided, discussion above, Australian Standards, and or supported findings.  We are of the opinion that there has always b een a foundation/movement issue on site, supported by several photographic and vis ual evidences found on site, as discussed above.  We are at opinion that the site was filled during the renovation/addition and the bedding/back - filling process were not pref ormed appropriately or was done poorly, therefore, causing seepage/ water ingress under the dwelling to occur on site.  The possible events suggested by the Insured, Earthquake and pipe leakage, would not have caused the existing cracking damage … We are of the opinion that these damages / cracking has been caused by poor, dated, or defective design / construction, ground/soil movement, and water seepage.  The inconsistency of the relationship bet ween water leak and the critical damage area of the dwelling is illustrated in diagram 5 and on the Google Maps Image below. Applicant’s Engineer ( JS ) Report 17 November 2017  Although the structural integrity of the dwelling was considered sound the observed defects as noted at the time of the inspection were deemed consistent with foundation movement induced by shallow footings being founded on highly reactive soils, with thes e soils being subjected to abnormal moisture conditions namely the leakage of the adjoining pipework. The dwelling overtime has been subjected to foundation movement with evidence of this noted from previous repairs undertaken. However, the leaking pipewor k has induced an abnormal moisture condition within the soil stratum and this continual wetting that has seen a greater swelling of the soils than normal to occur thus increasing the frequency and size of the defects as noted. From experience with these lo cal soils, the ongoing wetting induced by the leak would have extend over a large area and at depth thus increasing the "depth of suction charge". On review of our observations at the time of the inspection, the probable cause of the damage in our opinion is a direct result of:  On - going saturation of soil stratum to the dwelling cause by the leaking pipework. Although the dwelling would be subject to foundation movement induced by typical weather patterns which would induce cracking, the leaking pipe has i nduced an abnormal moisture conditions thus increasing the size and frequency of the cracking as noted.  The oversaturation of the soils toward the south - west corner of the dwelling induced by the leaking pipe has caused the foundation soils to "soften" hen ce reducing the bearing stressed under the isolated pads. This loss of bearing capacity has led to excessive settlement in the isolated piers and thus the sagging and bounce noted to timber floor along the western wall. Other contributing factors in our op inion are:  Poor sub - floor ventilation. It was noted on site that the sub - floor Case No: 496069 Determination Page 7 of 8 clearance was generally between 200 - 400mm which is less than the BCA requirements. Adequate cross ventilation is critical to ensure the subfloor required dry. The low clearanc e also means that the required 50mm fall over 1000mm as required by AS2870 - 2011 "Residential Slabs & Footings" is difficult to achieve.  Shallow footings founded on reactive soils. Although the foundation depth is unknown, the age of the dwelling would su ggest that the isolated footings are shallow. Shallow footings provide poor serviceability in reactive soils especially when subject to abnormal moisture conditions. 3.2 Policy Wording 3 General exclusions Your policy does not cover any loss or damage that is caused by or arises from: Maintenance and building o defects in design, structure, materials, workmanship or construction o failure to keep the property insured watertight, well maintained, structurally sound and secure. … Wear and tear, and environmental conditions. o wear and tear, gradual deterioration, or fading, o … o earth or soil movement (other than earthquake) including landslide, subsidence, or erosion o settling, expansion, shrinkage or vibration 4.3 Insured events (Building and Contents) Insured events … we will insure your building and/or contents at the site against loss or damage caused by the following events if they occur during your period of insurance. … Escape of liquid Covered Loss or damage caused by accidental escape of liquid from any fixed pipe, fixed tank, waterbed, fish tank, or fixed item used to hold liquid. We will also pay reasonable exploratory costs in locating the source of the damage, provided we have agreed to pay for the loss or damage caused by the escape of liquid. Not Covered  loss or damage to the item from which the liquid escaped, and if the liquid escaped from a shower recess, the cost of re-tiling the walls or floor of the shower recess.  repair or replacement of undamaged parts of your contents to match property tha t has been repaired or replaced  loss or damage caused by gradual escape of liquid which is evident and which you fail to rectify. Case No: 496069 Determination Page 8 of 8 Accidental loss or damage Covered Accidental loss or damage to: • your building and/or contents at the site, or … If loss or damage is caused by any other insured event, you must claim under that section of your policy. For every claim we agree to pay, your excess will be the greater of your basic excess or $300. Not covered Any loss or damage excluded under any insured events, unless otherwise stated. …