Home / Financial Firm (Unknown - Insurer) / Determination 494260
Determination 494260
Claim denied relying on policy exclusions for building movement damage
Summary
An owners corporation claimed for cracking damage to a strata unit's external walls, which the FSP denied under policy exclusions. AFCA found the FSP entitled to deny the claim.
The insurer bore the onus to establish the exclusions (earth movement, gradual deterioration, tree roots) and met it on the expert evidence.
Issues
- Claim denial primary · not upheld“The FSP is entitled to rely upon the exclusions within the policy coverage to deny the applicant's claim.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 494260 Determination Page 1 of 3
Case number: 494260 2 August 2018
1 Overview
1.1 Dispute
This matter involves a claim by the applicant under a Residential Strata Insurance
Policy, held with the Financial Services Provider (FSP), in respect to damage to the
insured property.
The FSP has denied the applicant’s claim on the basis of exclusions within the policy.
1.2 Issues and key findings
Is the FSP entitled to deny the claim on the basis of exclusions within the
policy?
The FSP is entitled to rely upon the exclusions within the policy coverage to deny the
applicant’s claim .
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitled to deny the applicant’s claim.
Case No: 494260 Determination Page 2 of 3
2 Reasons for determination
This dispute has been the subject of the recommendation issued by the service on 5
February 2018.
It was the case manager ’ s recommendation that the FSP was entitled to rely upon
exclusions within t he policy to deny the applicant’s claim.
The applicant has disputed the recommendation.
A copy of the recommendation is attached to this determination.
I have carefully considered all of the material provided both before and after the
recommendation in the preparation of this determination.
This determination follows consideration of all of the information exchanged and is
based on what is fair in the circumstances, having regards to the relevant legal
principles, terms of the policy, good industry practise and where applicable, prior
determinations.
2.1 Is the FSP entitled to deny the applicant’s claim on the basis of
exclusions within the policy coverage?
Coverage of the policy
The applicant’s Residential Strata Insurance Policy provides coverage against
accidental loss or damage to the insured property.
The coverage provided by the policy is subject to exclusions.
This means that not all loss and damage is automatically covered and any coverage
for loss provided by the policy is subject to exclusions which are detailed within the
policy.
The exclusions to policy coverage are detailed within the case manager’s
recommendation.
It is accepted insurance law that the FSP carries the onus to establish the application
of an exclusion upon which it seeks to rely to deny the applicant’s claim.
Circumstances of the loss
The exchanged material confirms that in November 2015 , the applicant lodged a
claim seeking cover for cracking to the external walls of the property, alleging that the
cracking occurred due to a leaking sewage pipe.
The parties have relied upon reports from a number of different experts to support
their respective positions.
The applicant says that the conclusion that the proximate cause of the damage to the
building is soil plasticity, is based upon flawed evidence.
The applicant maintains that the building footings are adequate, are not on any fill,
that there are expansion joints and that they are doing their job properly. Further, the
Case No: 494260 Determination Page 3 of 3
patching is in fact a damp course which was retro fitted, the bore hole drilled by the
FSP’s expert i s in the wrong location and rain water is not flowing back to the
foundations but away from them.
The applicant maintains that the suggestion of soil plasticity and less than adequate
footings as the primary cause of the movement in the building is not supported by the
available evidence.
The applicant has provided photographs said to show no cracking or movement in
footing, expansion joints in the property and says the render at the building was
never an attempt to conceal cracks or was for patching, but was rather for aesthetics
and to modernise the property.
The copy of the recommendation is attached to this determination and I am satisfied
that the recommendation includes an accurate summery of the numerous reports
provided and the various conclusions reached by the respective experts.
As previously stated, the coverage provided by the policy is subject to exclusions
detailed within the policy documentation and contained within the recommendation
referred to above.
The exclusions for coverage include gradual deterioration, earth movement and
invasion of tree or plant roots.
Whilst the applicant maintains that the render at the property was never an attempt to
conceal cracks or at no stage was it for patching, I am satisfied that the photographic
evidenc e presented by the FSP’s engineer JM, establishe s that there indeed was
patching of the premises and not an overall addition for render to improve the
aesthetics or modernise the property.
The photographs provided by JM clearly show evidence of extensive long-term
patching.
Further, whilst the applicant maintains that there are expansion joints at the property
the photographic evidence provided by JM again demonstrates that at least in some
areas of the property there were not expansion joints and long- term cracking is
evident and in my view related to the absence of expansion joints at that location.
Further, a number of the reports provided by the parties are consistent in their view
that building movement has contributed to the damage at the property.
In my view, the exchanged material confirms that this building movement has
occurred over a period of time and is in part related to the reactive nature of the
foundations soils.
Having reviewed all of the exchanged material I am satisfied that the FSP has met its
onus to establish the application of the exclusions upon which it seeks to rely.
The FSP is entitled to deny the applicant’s claim.
Recommendation
Case No: 494260 Recommendation Page 1 of 9
Case number: 494260 5 February 2018
3 Overview
3.1 Dispute
The applicant, which is an owners corporation, lodged a claim for damages sustained
to one of its strata units. The applicant is represented by agent C. For simplicity, I will
refer to the owners corporation applicant and agent C as ‘the applicant’.
The applicant says the building suffered movement damage as a result of a leaking
sewer pipe.
The FSP assessed the damages and subsequently denied the claim. In doing so, the
FSP says the cause of the damage was a number of factors which the policy
excludes.
The applicant disagrees and attributes the damages to the leaking sewer pipe.
3.2 Issues and key findings
Is the FSP entitled to deny the claim?
The FSP is entitled to deny the claim because:
the applicant has established a valid claim
while various experts have provided their opinion on the cause of damage, I find
FSP engineers more persuasive
damage is not attributed to a single leak event (sewer) but rather to ongoing
earth movement
the policy does not provide cover for earth movement as a result of
maintenance related issues.
3.3 Recommendation
This recommendation is in favour of the FSP.
Case No: 494260 Recommendation Page 2 of 9
4 Reasons for recommendation
4.1 Is the FSP entitled to deny the claim?
Applicant establish a valid claim
The applicant carry the initial onus to establish any loss or damage arising from an
event is covered by the terms and conditions of the policy. This is known as a valid
(prima facie) claim. Once established, it falls to the FSP to establish, on balance, the
cause of the damage was a policy exclusion or it is otherwise entitled to deny the
claim.
The applicant’s policy covers for accidental loss, subject to various conditions and
exclusions.
The policy does not define the expression ‘accidenta l damage’. Courts define
‘accidental damage’ as damage that is unintended and unexpected (from the point of
the insured person).
Cracking occurred to the external walls of one of the strata units. The applicant’s
considers the cause to be from ground movement after a leaking pipe.
The reports provided by the parties’ experts confirm there is cracking and movement
damage to various parts of the property.
Given the broad scope of policy cover, I am satisfied the applicant has established a
valid claim for damage sustained to the property.
The FSP however says the cracking occurred due to a number of factors the policy
excludes. Accordingly, it falls to the FSP to demonstrate the cause of the disputed
damage was a policy exclusion or it is otherwise entitled to deny the claim.
Property has been subject to movement and cracking
The applicant contacted the FSP to lodge a claim in November 2016 for cracking to
the external wall.
The applicant engaged engineer (TD) initially considered the settlement and wall
rotation the likely contributing factors to the damage. TD:
further said such occurrence is common for buildings of this age, founded on
highly plasticity soils
suggested a plumber need to check for any possible pipe leakage.
The applicant engaged a plumber (M), who reported tree roots penetrating the sewer
pipe in three different locations. The locations are along the south west (SW) corner
of the property. Later M reported earth movement was the probable cause for the
drain to crack and dislodge causing the leak.
The applicant attributed the movement and cracking damage to the cracks in the
sewer pipe.
Case No: 494260 Recommendation Page 3 of 9
Experts have provided differing opinions
All experts appointed by the parties agree the property is built on extremely reactive
clay soils and is reactive to changes in moisture. They also agree there is movement
damage to the property.
However, the experts have provided differing opinions about what caused the
differential foundation movement.
The FSP’s engineer (JM) and geotechnical engineer (S) considered the likely factors
contributing to the differential foundation movements to be:
in adequate drainage along both sides of unit
differential drying over the site and subsequently removal of adjacent trees
no movement joints in brick facades(requirement at time of construction)
previous rendered facades over a number of years confirm the long term
cracks.
JM says he could find no indications to support the sewer leakage was a contributing
factor to the damage. Furthermore, JM reported the slab settlement is greater on the
opposite side to the sewer pipe leakage. This suggests the sewer leak has not been
an issue or a contributing factor.
JM says whilst M did not mention a leak in his report, such leak (if exists) would not
be a significant leak. Further, the paving along the eastern side directs rain towards
the south east (SE) corner of the building.
JM notes the settlement at SE corner is more significant than SW corner where the
sewer pipe penetration is. Furthermore, JM says any fluid escape from sewer (if any)
is conducted along the trench fall and not back through the sides.
The applicant sought further clarification from TD, who later reported:
no trench on east side to allow water to pond against the wall and seep into
foundation
construction of the building is typical for the times and deep foundation reflect
superior construction
tree roots were attracted to the water leakage out of the sewer pipe
movement will happen regardless of movement joints
infill ground floor slab is not reflecting the movement in the building structure.
Further, TD says he did not see any documentation detailing long term issues and
poorly patched repairs.
The proximate cause of damage must be established
In order to determine whether the applicant’s claim falls within scope of cover, it is
necessary to determine the proximate cause of the loss. What is the proximate cause
of the loss is the question of fact depending upon the circumstances of each case.
It is well established that a proximate cause is not necessarily the first or last or the
sole cause of the loss. It is the effective or dominant or operative cause of the loss. If
there are several causes operating contemporaneously, then each must be
examined for the qualities of predominance and efficiency as the active efficient
cause that sets a relevant train of events in motion.
Case No: 494260 Recommendation Page 4 of 9
Courts have said that if one cause would have resulted in the harm in any case and
the other would not have done so in the absence of the first, then the first is the
proximate cause.
Applicant’s e xpert is inconclusive
The available information shows previous repairs to the external walls. This suggests
the cracking is a reoccurrence and the movement issues are of ongoing nature.
TD provided a report in response to JM and S’s observations. While TD refers to the
sewer pipe, significantly, he remained silent on the effect of adjacent trees and the
effect of the uneven/cracked pathways. Additionally in my view, TD did not illustrate
how the absence of the movement joint did not contribute to the house movement.
Conversely, TD remained silent on the possible causes of the historic repairs. He did
not provide any plausible explanation as to what is the proximate cause of these
repairs.
The applicant supplied photographs and a loss adjuster ’s assessment report of
another property. The applicant says the FSP accepted liability for similar damages.
The applicant similarly supplied photographs of the neighbouring property built
around the same time as the subject property. The applicant says this property did
not suffer any of the damages sustained to the subject property.
Ultimately this does not advance the applicant’s position. This is because each
property must be considered based upon the observed facts. In this case the FSP
(and the applicant’s expert ) carried out a comprehensive site specific assessment for
the subject property. These documents, as opposed to reports about another
property, are preferred.
The FSP is entitled to deny the claim
The FSP relies upon the general exclusions contained within the policy. The FSP
relies upon its experts (JM and S) in support of its position.
The FSP has supplied a number of independent assessment reports where its
findings are similar and consistent. Of relevance, the applicants’ experts findings
were ini tially consistent with the FSP’s. TD’s initial report attributed the damage to
ground movement and further commented such damage is a common occurrence for
buildings of this age. Further in M’s latest report, the plumber attributed the
damage/crack of the pipe to earth movement.
While I note TD changed its position, this was only after the FSP declined the claim.
In my view, TD has not satisfactory established why its opinion changed and its
subsequent report only refuted some, but not all, of the FSP’s ex perts arguments.
I have carefully considered all material provided by parties. On balance, I accept the
FSP engineers’ findings to be the most likely cause of the damage. This is because:
the geotechnical and the structural engineers’ findings are consist ent
the previous render repairs and patching highlighted the historic problem
it is plausible the sewer leak is conducted along the trench fall rather than
backward
Case No: 494260 Recommendation Page 5 of 9
Given this, I accept the above mentioned causes led to ground movement which
eventually cracked the pipe. I agree the current damages is a reoccurrence for a long
term and ongoing problem which is outside the policy’s scope of cover.
The FSP’s po licy is clear and unambiguous. Although earth movement is covered in
certain circumstances, it is not applicable to this dispute.
In these circumstances, applying relevant legal principles, foundation movement
would have occurred in the absence of the leaking pipe. Given this, I am satisfied the
leaking pipe is not proximate cause of the claimed damages.
Even if I accept the leaking pipe contributed to/exacerbated the claimed damages, I
do not accept the leaking pipe to be the proximate, dominant cause of the damage.
Further the applicant is of the opinion the cause of the leak was tree roots. Even if I
accept this argument (which I do not), the policy clearly excludes damage caused by
invasion of tree or plant roots.
Based on the above, the FSP is entitled to deny the claim.
Case No: 494260 Recommendation Page 6 of 9
5 Supporting information
5.1 Policy Wording
What we insure
We insure You up to the Sum Insured shown for Policy 1 on the Schedule, against accidental
loss or damage to Your Insured Property which occurs during the Period of Insurance.
1 We will not pay for loss or damage:
c caused by lack of maintenance, rust, oxidation, corrosion, Wear, Te ar, fading, gradual
corrosion or gradual deterioration, concrete or brick cancer, developing flaws, wet or dry rot, or
failure to maintain Your Insured Property in a reasonably good state of repair.
d caused by non-rectification of an Insured Property defect, error or omission that You were
aware of, or should reasonably have been aware of.
g caused by vibration or from the removal or weakening of or interference with the support of land
or buildings or any other property, Erosion or Earth Movement.
However We will pay if the loss or damage is due to:
ii bursting, leaking or overflowing of water tanks, pipes, drains, gutters or other water or liquid
carrying apparatus (but not Flood).
h caused by underground (hydrostatic) water.
However We will pay if the loss or damage is due to bursting, leaking or overflowing of water
tanks, pipes, or drains.
i caused by the invasion of tree or plant roots nor for the cost of clearing pipes or drains blocked
by any such invasion.
m due to normal settling, creeping, heaving, seepage, shrinkage, or expansion in buildings,
foundations / footings, walls, bridges, roadways, kerbing, driveways, paths, garden borders
and other structural improvements.
2 We will not pay for:
b the cost of rectifying faulty or defective materials or faulty or defective workmanship;
5.2 Key Documents
Record Key points
App’s plumber report (M)
18 - 02 - 2016
Attended property ran CCTV camera from behind unit 6's sewer
point which is the start of the drain falling towards the front of the
property, all sewer mainlines only, found three sections of pipe
where tree roots were entering located and marked at the re ar right
hand side of the property with yellow spray paint
Ran CCTV camera from pit to pit down all storm water mainlines
only found storm water drains to be ok ay
App’s plumber report (M)
18 - 10 - 2017
We are of the opinion that earth movement is the probable cause
for the drain to crack and dislodge causing the leak .
There is no routine maintenance that could have been put in place
Case No: 494260 Recommendation Page 7 of 9
to avoid or alert the OC of any issues within piping.
App’s engineer’s report
( TD )
Report
11 - 11 - 2015
Internal and extern al cracking was noted top unit 6
Crack patterns indicate that the rear walls of Unit 6 have settled
and rotated outwards
This is a common occurrence for buildings of this age, founded in
the upper reaches of the high plasticity soils
FSP’s engineer’s repo rt
(JM)
21 - 02 - 2017
Drainage around the building, particularly on the east side, is poor
with continual rainwater runoff being shed towards the SE corner
of the building
Additionally, maintenance on the building has been seriously
lacking in recent years.
The building displays a history of substantial patching of render
and repainting as well as ongoing replacement of sewer waste
lines including sewer repairs along the western side of the building
However, the brief plumbing report on the (M) invoice dated
February 25, 2016 merely mentions three locations in the sewer
line adjacent Unit 6 where tree roots had entered but did not
specifically mention any leak/s
It is the Writer’s experience that such tree root entries are common
and the sewers still function adequately with occasional cleaning
until a stage is eventually reached when the pipe needs replacing.
any fluid escape from the sewer is normally conducted along the
sewer trench and not back through the sides of the trench t owards
building foundations e ven with tree root intrusion
Additionally, it is understood that the sewer lines discharging from
Unit 6 have not been repaired and are still functional which would
therefore appear to confirm that most of the fluid must be
discharging down the pipe with o nly a relatively small amount of
fluid escape (if any)
Photo 8 is a view of a large tree stump remaining from the tree
being cut down. Tree roots from such a large tree would radiate out
a distance from the trunk of the tree between the height and three
ti mes the height of the tree. On this basis, tree root interference
with the footing foundations under Unit 6 with the potential to cause
drying and shri nkage of the slab foundations ( highly reactive soil)
resulting in floor slab settlement
Photo 36 illustra tes that there has been patching to concrete
paving. The rainwater catchment area that this paving represents
and cons equently the amount of rainwater runoff discharging
directly towards the building and into the foundations, should not
be underestimated - p articularly noting the highly reactive soil and
deep fill as confirmed in the attached S g eotechnic al report.
Referenc e is made to Photos 9 and 10 where it can be seen that
the paving has been substantially replaced in sections and that
grading is poor. De sirably, this paving should be dished and with
sufficient falls to collect rainwat er and discharge it into proposed
grated pits along the entire length of the building
Checking of floor levels within Unit 6 confirmed that the degree of
settlement of the fl oor slab towards the south was greater adjacent
the S.E. corner as distinct from the S.W. corner where the alleged
Case No: 494260 Recommendation Page 8 of 9
sewer leaks have occurred. The continual shedding of rainwater
runoff from the paving as illustrated on Photos 36, 37 & 38 is
considered to b e a key contributing factor in this regard Photos 17
and 18 are views into the kitchen area
On the other hand, Photos 22 and 23 are views into the S.E.
bedroom. The degree of settlement and misalignment of the floor
slab is clearly illustrated on Photo 24. This contrasts significantly
with the degree of settlement at the S.W. corner of Unit 6, as
illustrated in the bathroom on Phot os 25 and 26
This finding mak es it unlikely that the alleged leaking sewer has
been an issue with respect to the slab settlement
Photo 42 is a view of a small section of concrete broken out by the
Writer to investigate the slab footing. The investigations confirmed
as for Photo 43 that the edge slab had been built over deep fill and
that fill was not excessively moist but rather dr y. On this basis
since the sewer has not been repaired, this finding did not confirm
any leak
Photo 29 is a view of obvious patchi ng of the east façade of Unit 6
Photo 30 is a view of p ast patching beneath the window
Photo 31 is a view at a higher l evel of the ground floor window
A careful look at Photo 32 illustrates considerable patching of this
crack
Fundamentally, regular movement joints at not greater than 5m
intervals should have been installed in the brick facades at the time
the building was origina lly constructed
The render applied to the building is an aft erthought and believed
to have been an attempt by a previous owner to conceal cracks
prior to sale of the various Units. However, in the absence of any
movement joint provision, the cracks have re adily developed
A component of the cracking, particularly on the east façade,
however, is due to the floor slab settlement of the southern section
of the floor slab with the greatest degree of settlement on the
opposite side of the building to the sewer - na mely the SE corner
An opportunity with the original construction to install a movement
joint at least on one side of this threshold has been missed
T he continual shedding of rainwater from the large catchment area
of incorrectly graded paving as illustrated on Phot os 36, 37 & 38
would have readily seeped through the deep fill and into the footing
foundation
There are several factors which have contributed to the floor slab
settlement of the southern section of Unit 6 (refer S geotechnical
report)
Inadequate footing construction by today’s standards.
The highly reactive nature of the foundation clays
Damaged paving allowing rainwater to reach the foundations
Differential drying over the site and subsequently removal of
adjacent trees.
The absence of appropriate articulation in the brickwork.
Significantly, this report clearly confirms that the slab settlement
has been greater on the opposite side to the sewer. This makes it
unlikely that that a sewer leak as alleged has been an issue.
Case No: 494260 Recommendation Page 9 of 9
FSP’s geotec hnical
report (S)
01 - 02 - 2017
During our investigations we encountered the following site
features:
The presenc e of up to 1100mm of filling over the site
The evidence of a recently removed large tree from the adjacent
site to the west
Due to the presence of these features we have classified this site
as CLASS P (Problem Site – Filled & Abnormal Moisture
Conditions)
In the absenc e of these conditions a Class H2 classification would
be adopted
A large tree has been removed from the adjacent property to the
W est between March and October 2016 (refer attached Nearmap
images)
The concrete paving is very damaged and cracked on the western
side of the building
In our opinion the observed movement is due to a combination of
the following factors:
Inadequate footing s (by today’s standards) for the soil conditions
on site
The highly reactive nature of the foundation clays
The damaged paving allows excess moisture to penet rate the
pavement to the underlying soils
Differential drying over the site created by the presenc e and
subsequent removal of adjacent tr ees
The absence of articulation of the brickwork
App’s engineer’s report
( TD )
Report
15 - 06 - 2017
Building movement - either footings or infill slabs - is caused by soil
movement below ground level. This movement will occur whether
the brickwork is articulated or not. The same scenario applies to
movement joints in the walkways
The existing conditions along the west side of the building have still
not been investigated, despite JM’s admonishment of TD in this
regard.
Bl anket statements on the past history of the building have been
made without relevant evidence
Cracked pipes are referred to, but not commented on as a possible
source of leaking fluids
The infill ground floor slab movement is incorrectly repres ented as
ref lecting the movement in the building structure.
The soil test did not determine both the footing depth, and the
depth below ground of the base of the footing.
Any assertion that the footing is inadequate therefore has no basis,
and is to be ignored
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.