Home / Financial Firm (Unknown - Insurer) / Determination 494260

Determination 494260

Claim denied relying on policy exclusions for building movement damage

FirmFinancial Firm (Unknown - Insurer)
Decided2018-08-02
ProductGeneral Insurance · Strata
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

An owners corporation claimed for cracking damage to a strata unit's external walls, which the FSP denied under policy exclusions. AFCA found the FSP entitled to deny the claim.

The insurer bore the onus to establish the exclusions (earth movement, gradual deterioration, tree roots) and met it on the expert evidence.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 494260 Determination Page 1 of 3 Case number: 494260 2 August 2018 1 Overview 1.1 Dispute This matter involves a claim by the applicant under a Residential Strata Insurance Policy, held with the Financial Services Provider (FSP), in respect to damage to the insured property. The FSP has denied the applicant’s claim on the basis of exclusions within the policy. 1.2 Issues and key findings Is the FSP entitled to deny the claim on the basis of exclusions within the policy? The FSP is entitled to rely upon the exclusions within the policy coverage to deny the applicant’s claim . 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny the applicant’s claim. Case No: 494260 Determination Page 2 of 3 2 Reasons for determination This dispute has been the subject of the recommendation issued by the service on 5 February 2018. It was the case manager ’ s recommendation that the FSP was entitled to rely upon exclusions within t he policy to deny the applicant’s claim. The applicant has disputed the recommendation. A copy of the recommendation is attached to this determination. I have carefully considered all of the material provided both before and after the recommendation in the preparation of this determination. This determination follows consideration of all of the information exchanged and is based on what is fair in the circumstances, having regards to the relevant legal principles, terms of the policy, good industry practise and where applicable, prior determinations. 2.1 Is the FSP entitled to deny the applicant’s claim on the basis of exclusions within the policy coverage? Coverage of the policy The applicant’s Residential Strata Insurance Policy provides coverage against accidental loss or damage to the insured property. The coverage provided by the policy is subject to exclusions. This means that not all loss and damage is automatically covered and any coverage for loss provided by the policy is subject to exclusions which are detailed within the policy. The exclusions to policy coverage are detailed within the case manager’s recommendation. It is accepted insurance law that the FSP carries the onus to establish the application of an exclusion upon which it seeks to rely to deny the applicant’s claim. Circumstances of the loss The exchanged material confirms that in November 2015 , the applicant lodged a claim seeking cover for cracking to the external walls of the property, alleging that the cracking occurred due to a leaking sewage pipe. The parties have relied upon reports from a number of different experts to support their respective positions. The applicant says that the conclusion that the proximate cause of the damage to the building is soil plasticity, is based upon flawed evidence. The applicant maintains that the building footings are adequate, are not on any fill, that there are expansion joints and that they are doing their job properly. Further, the Case No: 494260 Determination Page 3 of 3 patching is in fact a damp course which was retro fitted, the bore hole drilled by the FSP’s expert i s in the wrong location and rain water is not flowing back to the foundations but away from them. The applicant maintains that the suggestion of soil plasticity and less than adequate footings as the primary cause of the movement in the building is not supported by the available evidence. The applicant has provided photographs said to show no cracking or movement in footing, expansion joints in the property and says the render at the building was never an attempt to conceal cracks or was for patching, but was rather for aesthetics and to modernise the property. The copy of the recommendation is attached to this determination and I am satisfied that the recommendation includes an accurate summery of the numerous reports provided and the various conclusions reached by the respective experts. As previously stated, the coverage provided by the policy is subject to exclusions detailed within the policy documentation and contained within the recommendation referred to above. The exclusions for coverage include gradual deterioration, earth movement and invasion of tree or plant roots. Whilst the applicant maintains that the render at the property was never an attempt to conceal cracks or at no stage was it for patching, I am satisfied that the photographic evidenc e presented by the FSP’s engineer JM, establishe s that there indeed was patching of the premises and not an overall addition for render to improve the aesthetics or modernise the property. The photographs provided by JM clearly show evidence of extensive long-term patching. Further, whilst the applicant maintains that there are expansion joints at the property the photographic evidence provided by JM again demonstrates that at least in some areas of the property there were not expansion joints and long- term cracking is evident and in my view related to the absence of expansion joints at that location. Further, a number of the reports provided by the parties are consistent in their view that building movement has contributed to the damage at the property. In my view, the exchanged material confirms that this building movement has occurred over a period of time and is in part related to the reactive nature of the foundations soils. Having reviewed all of the exchanged material I am satisfied that the FSP has met its onus to establish the application of the exclusions upon which it seeks to rely. The FSP is entitled to deny the applicant’s claim. Recommendation Case No: 494260 Recommendation Page 1 of 9 Case number: 494260 5 February 2018 3 Overview 3.1 Dispute The applicant, which is an owners corporation, lodged a claim for damages sustained to one of its strata units. The applicant is represented by agent C. For simplicity, I will refer to the owners corporation applicant and agent C as ‘the applicant’. The applicant says the building suffered movement damage as a result of a leaking sewer pipe. The FSP assessed the damages and subsequently denied the claim. In doing so, the FSP says the cause of the damage was a number of factors which the policy excludes. The applicant disagrees and attributes the damages to the leaking sewer pipe. 3.2 Issues and key findings Is the FSP entitled to deny the claim? The FSP is entitled to deny the claim because:  the applicant has established a valid claim  while various experts have provided their opinion on the cause of damage, I find FSP engineers more persuasive  damage is not attributed to a single leak event (sewer) but rather to ongoing earth movement  the policy does not provide cover for earth movement as a result of maintenance related issues. 3.3 Recommendation This recommendation is in favour of the FSP. Case No: 494260 Recommendation Page 2 of 9 4 Reasons for recommendation 4.1 Is the FSP entitled to deny the claim? Applicant establish a valid claim The applicant carry the initial onus to establish any loss or damage arising from an event is covered by the terms and conditions of the policy. This is known as a valid (prima facie) claim. Once established, it falls to the FSP to establish, on balance, the cause of the damage was a policy exclusion or it is otherwise entitled to deny the claim. The applicant’s policy covers for accidental loss, subject to various conditions and exclusions. The policy does not define the expression ‘accidenta l damage’. Courts define ‘accidental damage’ as damage that is unintended and unexpected (from the point of the insured person). Cracking occurred to the external walls of one of the strata units. The applicant’s considers the cause to be from ground movement after a leaking pipe. The reports provided by the parties’ experts confirm there is cracking and movement damage to various parts of the property. Given the broad scope of policy cover, I am satisfied the applicant has established a valid claim for damage sustained to the property. The FSP however says the cracking occurred due to a number of factors the policy excludes. Accordingly, it falls to the FSP to demonstrate the cause of the disputed damage was a policy exclusion or it is otherwise entitled to deny the claim. Property has been subject to movement and cracking The applicant contacted the FSP to lodge a claim in November 2016 for cracking to the external wall. The applicant engaged engineer (TD) initially considered the settlement and wall rotation the likely contributing factors to the damage. TD:  further said such occurrence is common for buildings of this age, founded on highly plasticity soils  suggested a plumber need to check for any possible pipe leakage. The applicant engaged a plumber (M), who reported tree roots penetrating the sewer pipe in three different locations. The locations are along the south west (SW) corner of the property. Later M reported earth movement was the probable cause for the drain to crack and dislodge causing the leak. The applicant attributed the movement and cracking damage to the cracks in the sewer pipe. Case No: 494260 Recommendation Page 3 of 9 Experts have provided differing opinions All experts appointed by the parties agree the property is built on extremely reactive clay soils and is reactive to changes in moisture. They also agree there is movement damage to the property. However, the experts have provided differing opinions about what caused the differential foundation movement. The FSP’s engineer (JM) and geotechnical engineer (S) considered the likely factors contributing to the differential foundation movements to be:  in adequate drainage along both sides of unit  differential drying over the site and subsequently removal of adjacent trees  no movement joints in brick facades(requirement at time of construction)  previous rendered facades over a number of years confirm the long term cracks. JM says he could find no indications to support the sewer leakage was a contributing factor to the damage. Furthermore, JM reported the slab settlement is greater on the opposite side to the sewer pipe leakage. This suggests the sewer leak has not been an issue or a contributing factor. JM says whilst M did not mention a leak in his report, such leak (if exists) would not be a significant leak. Further, the paving along the eastern side directs rain towards the south east (SE) corner of the building. JM notes the settlement at SE corner is more significant than SW corner where the sewer pipe penetration is. Furthermore, JM says any fluid escape from sewer (if any) is conducted along the trench fall and not back through the sides. The applicant sought further clarification from TD, who later reported:  no trench on east side to allow water to pond against the wall and seep into foundation  construction of the building is typical for the times and deep foundation reflect superior construction  tree roots were attracted to the water leakage out of the sewer pipe  movement will happen regardless of movement joints  infill ground floor slab is not reflecting the movement in the building structure. Further, TD says he did not see any documentation detailing long term issues and poorly patched repairs. The proximate cause of damage must be established In order to determine whether the applicant’s claim falls within scope of cover, it is necessary to determine the proximate cause of the loss. What is the proximate cause of the loss is the question of fact depending upon the circumstances of each case. It is well established that a proximate cause is not necessarily the first or last or the sole cause of the loss. It is the effective or dominant or operative cause of the loss. If there are several causes operating contemporaneously, then each must be examined for the qualities of predominance and efficiency as the active efficient cause that sets a relevant train of events in motion. Case No: 494260 Recommendation Page 4 of 9 Courts have said that if one cause would have resulted in the harm in any case and the other would not have done so in the absence of the first, then the first is the proximate cause. Applicant’s e xpert is inconclusive The available information shows previous repairs to the external walls. This suggests the cracking is a reoccurrence and the movement issues are of ongoing nature. TD provided a report in response to JM and S’s observations. While TD refers to the sewer pipe, significantly, he remained silent on the effect of adjacent trees and the effect of the uneven/cracked pathways. Additionally in my view, TD did not illustrate how the absence of the movement joint did not contribute to the house movement. Conversely, TD remained silent on the possible causes of the historic repairs. He did not provide any plausible explanation as to what is the proximate cause of these repairs. The applicant supplied photographs and a loss adjuster ’s assessment report of another property. The applicant says the FSP accepted liability for similar damages. The applicant similarly supplied photographs of the neighbouring property built around the same time as the subject property. The applicant says this property did not suffer any of the damages sustained to the subject property. Ultimately this does not advance the applicant’s position. This is because each property must be considered based upon the observed facts. In this case the FSP (and the applicant’s expert ) carried out a comprehensive site specific assessment for the subject property. These documents, as opposed to reports about another property, are preferred. The FSP is entitled to deny the claim The FSP relies upon the general exclusions contained within the policy. The FSP relies upon its experts (JM and S) in support of its position. The FSP has supplied a number of independent assessment reports where its findings are similar and consistent. Of relevance, the applicants’ experts findings were ini tially consistent with the FSP’s. TD’s initial report attributed the damage to ground movement and further commented such damage is a common occurrence for buildings of this age. Further in M’s latest report, the plumber attributed the damage/crack of the pipe to earth movement. While I note TD changed its position, this was only after the FSP declined the claim. In my view, TD has not satisfactory established why its opinion changed and its subsequent report only refuted some, but not all, of the FSP’s ex perts arguments. I have carefully considered all material provided by parties. On balance, I accept the FSP engineers’ findings to be the most likely cause of the damage. This is because:  the geotechnical and the structural engineers’ findings are consist ent  the previous render repairs and patching highlighted the historic problem  it is plausible the sewer leak is conducted along the trench fall rather than backward Case No: 494260 Recommendation Page 5 of 9 Given this, I accept the above mentioned causes led to ground movement which eventually cracked the pipe. I agree the current damages is a reoccurrence for a long term and ongoing problem which is outside the policy’s scope of cover. The FSP’s po licy is clear and unambiguous. Although earth movement is covered in certain circumstances, it is not applicable to this dispute. In these circumstances, applying relevant legal principles, foundation movement would have occurred in the absence of the leaking pipe. Given this, I am satisfied the leaking pipe is not proximate cause of the claimed damages. Even if I accept the leaking pipe contributed to/exacerbated the claimed damages, I do not accept the leaking pipe to be the proximate, dominant cause of the damage. Further the applicant is of the opinion the cause of the leak was tree roots. Even if I accept this argument (which I do not), the policy clearly excludes damage caused by invasion of tree or plant roots. Based on the above, the FSP is entitled to deny the claim. Case No: 494260 Recommendation Page 6 of 9 5 Supporting information 5.1 Policy Wording What we insure We insure You up to the Sum Insured shown for Policy 1 on the Schedule, against accidental loss or damage to Your Insured Property which occurs during the Period of Insurance. 1 We will not pay for loss or damage: c caused by lack of maintenance, rust, oxidation, corrosion, Wear, Te ar, fading, gradual corrosion or gradual deterioration, concrete or brick cancer, developing flaws, wet or dry rot, or failure to maintain Your Insured Property in a reasonably good state of repair. d caused by non-rectification of an Insured Property defect, error or omission that You were aware of, or should reasonably have been aware of. g caused by vibration or from the removal or weakening of or interference with the support of land or buildings or any other property, Erosion or Earth Movement. However We will pay if the loss or damage is due to: ii bursting, leaking or overflowing of water tanks, pipes, drains, gutters or other water or liquid carrying apparatus (but not Flood). h caused by underground (hydrostatic) water. However We will pay if the loss or damage is due to bursting, leaking or overflowing of water tanks, pipes, or drains. i caused by the invasion of tree or plant roots nor for the cost of clearing pipes or drains blocked by any such invasion. m due to normal settling, creeping, heaving, seepage, shrinkage, or expansion in buildings, foundations / footings, walls, bridges, roadways, kerbing, driveways, paths, garden borders and other structural improvements. 2 We will not pay for: b the cost of rectifying faulty or defective materials or faulty or defective workmanship; 5.2 Key Documents Record Key points App’s plumber report (M) 18 - 02 - 2016  Attended property ran CCTV camera from behind unit 6's sewer point which is the start of the drain falling towards the front of the property, all sewer mainlines only, found three sections of pipe where tree roots were entering located and marked at the re ar right hand side of the property with yellow spray paint  Ran CCTV camera from pit to pit down all storm water mainlines only found storm water drains to be ok ay App’s plumber report (M) 18 - 10 - 2017  We are of the opinion that earth movement is the probable cause for the drain to crack and dislodge causing the leak .  There is no routine maintenance that could have been put in place Case No: 494260 Recommendation Page 7 of 9 to avoid or alert the OC of any issues within piping. App’s engineer’s report ( TD ) Report 11 - 11 - 2015  Internal and extern al cracking was noted top unit 6  Crack patterns indicate that the rear walls of Unit 6 have settled and rotated outwards  This is a common occurrence for buildings of this age, founded in the upper reaches of the high plasticity soils FSP’s engineer’s repo rt (JM) 21 - 02 - 2017  Drainage around the building, particularly on the east side, is poor with continual rainwater runoff being shed towards the SE corner of the building  Additionally, maintenance on the building has been seriously lacking in recent years.  The building displays a history of substantial patching of render and repainting as well as ongoing replacement of sewer waste lines including sewer repairs along the western side of the building  However, the brief plumbing report on the (M) invoice dated February 25, 2016 merely mentions three locations in the sewer line adjacent Unit 6 where tree roots had entered but did not specifically mention any leak/s  It is the Writer’s experience that such tree root entries are common and the sewers still function adequately with occasional cleaning until a stage is eventually reached when the pipe needs replacing.  any fluid escape from the sewer is normally conducted along the sewer trench and not back through the sides of the trench t owards building foundations e ven with tree root intrusion  Additionally, it is understood that the sewer lines discharging from Unit 6 have not been repaired and are still functional which would therefore appear to confirm that most of the fluid must be discharging down the pipe with o nly a relatively small amount of fluid escape (if any)  Photo 8 is a view of a large tree stump remaining from the tree being cut down. Tree roots from such a large tree would radiate out a distance from the trunk of the tree between the height and three ti mes the height of the tree. On this basis, tree root interference with the footing foundations under Unit 6 with the potential to cause drying and shri nkage of the slab foundations ( highly reactive soil) resulting in floor slab settlement  Photo 36 illustra tes that there has been patching to concrete paving. The rainwater catchment area that this paving represents and cons equently the amount of rainwater runoff discharging directly towards the building and into the foundations, should not be underestimated - p articularly noting the highly reactive soil and deep fill as confirmed in the attached S g eotechnic al report. Referenc e is made to Photos 9 and 10 where it can be seen that the paving has been substantially replaced in sections and that grading is poor. De sirably, this paving should be dished and with sufficient falls to collect rainwat er and discharge it into proposed grated pits along the entire length of the building  Checking of floor levels within Unit 6 confirmed that the degree of settlement of the fl oor slab towards the south was greater adjacent the S.E. corner as distinct from the S.W. corner where the alleged Case No: 494260 Recommendation Page 8 of 9 sewer leaks have occurred. The continual shedding of rainwater runoff from the paving as illustrated on Photos 36, 37 & 38 is considered to b e a key contributing factor in this regard Photos 17 and 18 are views into the kitchen area  On the other hand, Photos 22 and 23 are views into the S.E. bedroom. The degree of settlement and misalignment of the floor slab is clearly illustrated on Photo 24. This contrasts significantly with the degree of settlement at the S.W. corner of Unit 6, as illustrated in the bathroom on Phot os 25 and 26  This finding mak es it unlikely that the alleged leaking sewer has been an issue with respect to the slab settlement  Photo 42 is a view of a small section of concrete broken out by the Writer to investigate the slab footing. The investigations confirmed as for Photo 43 that the edge slab had been built over deep fill and that fill was not excessively moist but rather dr y. On this basis since the sewer has not been repaired, this finding did not confirm any leak  Photo 29 is a view of obvious patchi ng of the east façade of Unit 6  Photo 30 is a view of p ast patching beneath the window  Photo 31 is a view at a higher l evel of the ground floor window  A careful look at Photo 32 illustrates considerable patching of this crack  Fundamentally, regular movement joints at not greater than 5m intervals should have been installed in the brick facades at the time the building was origina lly constructed  The render applied to the building is an aft erthought and believed to have been an attempt by a previous owner to conceal cracks prior to sale of the various Units. However, in the absence of any movement joint provision, the cracks have re adily developed  A component of the cracking, particularly on the east façade, however, is due to the floor slab settlement of the southern section of the floor slab with the greatest degree of settlement on the opposite side of the building to the sewer - na mely the SE corner  An opportunity with the original construction to install a movement joint at least on one side of this threshold has been missed  T he continual shedding of rainwater from the large catchment area of incorrectly graded paving as illustrated on Phot os 36, 37 & 38 would have readily seeped through the deep fill and into the footing foundation  There are several factors which have contributed to the floor slab settlement of the southern section of Unit 6 (refer S geotechnical report)  Inadequate footing construction by today’s standards.  The highly reactive nature of the foundation clays  Damaged paving allowing rainwater to reach the foundations  Differential drying over the site and subsequently removal of adjacent trees.  The absence of appropriate articulation in the brickwork.  Significantly, this report clearly confirms that the slab settlement has been greater on the opposite side to the sewer. This makes it unlikely that that a sewer leak as alleged has been an issue. Case No: 494260 Recommendation Page 9 of 9 FSP’s geotec hnical report (S) 01 - 02 - 2017  During our investigations we encountered the following site features:  The presenc e of up to 1100mm of filling over the site  The evidence of a recently removed large tree from the adjacent site to the west  Due to the presence of these features we have classified this site as CLASS P (Problem Site – Filled & Abnormal Moisture Conditions)  In the absenc e of these conditions a Class H2 classification would be adopted  A large tree has been removed from the adjacent property to the W est between March and October 2016 (refer attached Nearmap images)  The concrete paving is very damaged and cracked on the western side of the building  In our opinion the observed movement is due to a combination of the following factors:  Inadequate footing s (by today’s standards) for the soil conditions on site  The highly reactive nature of the foundation clays  The damaged paving allows excess moisture to penet rate the pavement to the underlying soils  Differential drying over the site created by the presenc e and subsequent removal of adjacent tr ees  The absence of articulation of the brickwork App’s engineer’s report ( TD ) Report 15 - 06 - 2017  Building movement - either footings or infill slabs - is caused by soil movement below ground level. This movement will occur whether the brickwork is articulated or not. The same scenario applies to movement joints in the walkways  The existing conditions along the west side of the building have still not been investigated, despite JM’s admonishment of TD in this regard.  Bl anket statements on the past history of the building have been made without relevant evidence  Cracked pipes are referred to, but not commented on as a possible source of leaking fluids  The infill ground floor slab movement is incorrectly repres ented as ref lecting the movement in the building structure.  The soil test did not determine both the footing depth, and the depth below ground of the base of the footing.  Any assertion that the footing is inadequate therefore has no basis, and is to be ignored

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.