Home / Financial Firm (Unknown - Insurer) / Determination 493952

Determination 493952

Claim declined for storm damage to deck, exclusions relied on

FirmFinancial Firm (Unknown - Insurer)
Decided2018-05-28
ProductGeneral Insurance · Landlord
OutcomeFor the complainant
Amount awarded$32,239
Non-financial loss—
Amount claimed$32,529
SourceAFCA PDF

Summary

The landlord policy claim for deck damage was declined by the FSP under wear and tear, corrosion and inherent defect exclusions. AFCA found the FSP had not established any exclusion and ordered it to pay the deck repair cost with interest.

Once an accidental loss is established, the FSP bears the onus of proving an exclusion, and the proximate cause was the missing waterproof membrane rather than an excluded cause.

Issues

Subjects and remedies

home or building damagepay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 493952 Determination Page 1 of 4 Case number: 493952 25 May 2018 1 Overview 1.1 Dispute The applicant lodged a claim under her Landlords Insurance Policy with the financial services provider (FSP) for storm damage to the front deck attached to her house. The claim was assessed by the FSP and liability was declined. The FSP found no evidence of storm damage to the deck and says the damage was caused by factors such as wear and tear and corrosion which were excluded under the policy. The case manager provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the applicant. A copy of the recommendation is attached to this determination. 1.2 Issues and key findings Were the findings of the recommendation correct? I have considered all submissions in this dispute including the further submissions provided after the recommendation. I am satisfied that the findings contained in the recommendation were correct and are adopted in this determination. Is the FSP entitled to decline the applicant’s claim? The FSP has not established exclusions apply to the applicant‟s claim. It has been identified that a water proof membrane was not applied to the applicant‟s deck. I am therefore satisfied the applicant has established a valid claim for „accidental loss or damage‟ , which is defined as an unforeseen and uncontrollable incident. 1.3 Determination This determination is in favour of the applicant. I agree with the case manager‟s reasons for the recommen dation and the recommended outcome. The FSP is required to pay $32,238.97 , based on the applicant‟s deck repair invoice dated 30 March 2017. In accordance with section 57 of the Insurance Contracts Act (the Act), the FSP is required to pay interest from 30 March 2017. Case No: 493952 Determination Page 2 of 4 2 Reasons for determination 2.1 Were the findings in the recommendation correct? I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. I am satisfied that the case manager‟s recommendation contains an accurate summary of the dispute, the issues to be determined, any applicable paragraphs of the Terms of Reference and any relevant law. Further submission provided after the recommendation The FSP rejected the recommendation and where relevant, this material is referred to in the determination. 2.2 Is the FSP entitled to decline the applicant’s claim? The policy provides cover for accidental damage or loss The applicant‟s policy provides cover for insured events and accidental loss or damage, subject to conditions and exclusions. Accidental loss or damage is defined as: Damage to, loss or destruction of your buildings or contents caused by an unintentional act, or an unforeseen or uncontrollable incident. Based on this definition, I consider the applicant has established a prima facie claim. Once so established, the onus shifts to the FSP to prove on the balance of probabilities an exclusion applies if it seeks to deny or limit its liability for the loss. FSP must establish policy exclusions relied on apply In the context of this claim, the FSP must establish the damage was caused by:  gradual deterioration, wear and tear  rust and corrosion. Alternatively, the FSP must establish the following exclusion can be applied:  inherent defect, faulty design, structural defects or poor workmanship. FSP relies on its expert reports The FSP had „BS‟ builders and „CR‟ en gineers attend the insured property to determine the cause and extent of damage. Both reports confirm:  t he deck to the applicant‟s property has incurred severe water damage as a result of rainwater penetrating the deck Case No: 493952 Determination Page 3 of 4  supporting timbers have decayed  water has leaked through fibre cement sub-straight fitted to joists which is tiled over  there is no water proof membrane  the home was built in 1996  had a water proof membrane been installed, water ingress into the cavity of the deck would not have occurred. The FSP declined to the applicant‟s claim citing the following exclusions appl y to the cause of the damage. When we will not pay a claim under your policy … 1. f. Wear and tear arising out of depreciation, gradual deterioration, wear and tear ; … 2. d. loss or damage which is caused directly or indirectly by: …  rust, corrosion, algae, mould or mildew; or … The FSP says if accidental loss or damage is considered to be the cause of the loss, then the following additional exclusion applies to the claim. g. Inherent defects caused directly or indirectly through inherent defect, faulty design, structural defects or poor workmanship; FSP have not established policy exclusions When reviewing the information provided by the FSP, a common factor confirmed by the parties is that a waterproof membrane has not been applied to the deck. The FSP says in its additional response if „ accidental loss or damage ‟ is considered the cause, the exclusions will still apply. The FSP‟s further submission states the lack of a water proof membrane is only a contributing factor, the dominant cause of the loss is the rust and steel beam. I do not agree with this. As identified, the cause of the loss is not having the waterproof membrane in place to stop the penetration of water. The co rrosion and wear and tear have come after the cause has been identified. CR in its report have confirmed; 5.4.6 It is our opinion that if a water proof membrane had been installed, water ingress into the cavity of the deck would not have occurred. The evidence does not support a finding that the damage was due to wear and tear or loss or damage was caused by rust, corrosion, algae, mould or mildew Therefore, I am satisfied the FSP has not established an exclusion applies to the applicant‟s claim. Case No: 493952 Determination Page 4 of 4 Additionally, the FSP say if the claim is to be considered as „accidental loss or damage ‟ the claim can be excluded as the damage was the result of an inherent defect, faulty design, structural defect or poor workmanship. However, a judgement on this issue must be made considering of the standards that applied at the time of the construction of the deck. There is no evidence that the deck was poorly constructed, had a faulty design, structural defect or inherent defect other than the lack of the waterproof membrane. CR in its report has cited the current standard for the installation of a waterproof membrane is AS4654.2-2009 Waterproof membrane systems for exterior use. This standard did not exist when the home was built in 1996. I am satisfied the deck was constructed in accordance with the standards that applied at that point in time. Accordingly, the additional exclusion of an inherent defect or poor workmanship does not apply. As stated previously, „accidental loss or damage‟ is defined as an unintentional act, or an unforeseen or uncontrollable incident. As the applicant was not aware that a membrane was not in place, the damage could not have been foreseen and was uncontrollable. I am satisfied the FSP has not established any exclusion applies to the applicant‟s claim and It is required to meet the applicant‟s loss. Recommendation Case No: 493952 Recommendation Page 1 of 11 Case number: 493952 26 February 2018 3 Overview 3.1 Dispute A broker (PM) represents the applicant in this dispute. For simplicity, this recommendation will refer to the applicant and her broker collectively as the applicant. The applicant says a storm damaged a deck at her insured property. She wants the financial services provider (FSP) to pay for the cost to repair the deck damage. The FSP declined her claim. It says the deck damage was not caused by a storm (or any other insured event). 3.2 Issues and key findings Has the applicant established a claim? The applicant has established a valid claim within the terms of the policy. The policy provides cover for accidental loss and damage and it is not in dispute the applicant did not intend for the deck damage. Is the FSP entitled to decline the claim? The information shows the proximate cause of the deck damage was the lack of waterproofing membrane. The FSP has not established wear and tear, rot and corrosion (policy exclusions) proximately caused the deck damage. As such the FSP is not entitled to decline the claim. 3.3 Recommendation This recommendation is in favour of the applicant. The FSP is required to pay:  $32,328.87, based on the applicant‟s deck repair invoice (dated 30 March 2017)  interest on this amount, from 30 March 2017 (date of the invoice) until the day the amount is paid. Case No: 493952 Recommendation Page 2 of 11 4 Reasons for recommendation 4.1 Has the applicant established a claim? The applicant has established a valid claim under the terms of the policy The applicant‟s policy provides cover for damage caused by insured events. It also provides cover for accidental damage. The product disclosure statement (PDS) sets out the term of cover. The relevant sections are set out in section 3.1 of this recommendation. The policy defines accidental loss and damage as damage caused by an unintentional act, or an unforeseen or uncontrollable incident. It is not in dispute:  the deck was damaged; rusted steel beam, rotted timber joists, etc  the applicant did not intend for this deck damage. The FSP says the deck damage was not caused a storm event. In considering whether the applicant has established a claim, it is unnecessary to find whether a storm event caused the deck damage. This is because the applicant‟s policy provides cover for accidental damage. The applicant has established a valid claim. 4.2 Is the FSP entitled to decline the claim? FSP say several exclusions apply in the circumstances As the applicant has established a valid claim, the FSP bears the onus of establishing, on the balance of probabilities that a policy exclusion applies. The FSP is not denying the claim for faulty design or poor workmanship (final decision letter dated 27 February 2017). Instead, the FSP says it can decline the claim because of the application of following policy exclusions:  wear and tear  rot  corrosion. Information available does not support the application of the exclusions The information available does not support the FSP‟s position that any of the above policy exclusions apply. There is much discussion between the parties as to whether wind from a 2010 severe storm could have flexed the deck. However I am not persuaded on the information available this was the proximate cause of the water ingress. Instead, the information shows it was more likely the proximate cause of the damage was the lack of waterproofing membrane. Both parties agrees water entered the decking cavity for many years. Case No: 493952 Recommendation Page 3 of 11 The FSP‟s builder (RS) says water ingress occurred because there was no installation of a water proofing membrane, or that membrane has failed due to age. The FSP‟s engineer (CR) went further to confirm there was no water proofing membrane installed. CR:  found there was no membrane against the wall of the residence, around the steel posts, nor was the membrane visible from under the decking  says if there was water proofing membrane, then it should be evident  says if water membrane had been installed, then no water ingress into the deck cavity would have occurred. I am persuaded by CR‟s view of how the deck damage occurred. His report is thorough and logical, and supported by many colour photographs. Havi ng regard to CR‟s view, I am not satisfied the lack of waterproofing membrane can be characterised as any of the policy exclusions relied upon by the FSP (wear and tear, rot, corrosion). FSP liable for the deck damage Therefore, the FSP is liable to cover the applicant‟s claim for the deck damage. This is because:  the applicant has established a valid claim, and  the proximate cause of the deck damage is not excluded by the policy exclusions relied upon by the FSP. The applicant has provided a repair invoice for the deck totalling $38,128.87 (dated 30 March 2017). He accepts the work for the aluminium balustrades, painting of pitched ceiling above the deck and waterproofing the deck is not covered (betterment). He agrees not to be paid for these items. Adjusting for this, the applicant is claiming for $32,528.87 less excess. The FSP is required to cash settle the deck damage for $32,528.87 less $200 (the applicable excess). The applicant advised FOS he does not wish to claim for any other cost nor interest. However, given the FSP is required to cash settle claim, in accordance with section 57 of the Insurance Contracts Act 1984 (the Act), the FSP is required to pay interest. It is required to pay interest on the sum $32,328.87 from 30 March 2017 (date of the invoice) until the day the amount is paid. Case No: 493952 Recommendation Page 4 of 11 5 Supporting information 5.1 Key policy wording Types of loss or damage your buildings are covered for We will cover your buildings against loss or damage caused by one or more of the insured events occurring during the period of insurance. We will also cover you for the other benefits listed below. Details of the terms, conditions and exclusions which specifically relate to each insured event and other benefits are detailed on the pages indicated. … Insured events we will pay … 2. Accidental loss or damage (Applicable whether you have buildings and/or contents cover) We will pay for accidental loss or damage, unless it is caused by: a. an event otherwise excluded under sections “Insured events we will pay” on pages 25 to 32 or “When we will not pay a claim under your policy” on pages 51 to 54 … 10. Storm, rainwater or run-off (Applicable whether you have buildings and/or contents cover) We will pay for loss or damage caused by storm, rainwater or run-off. We will not pay for loss or damage: … g. caused by water seeping, percolating or otherwise penetrating into the buildings as a result of: • structural defects; • faulty design of the buildings; • faulty workmanship in the construction of the buildings; or • you r failure to adequately maintain the buildings; … Words with special meanings Some of the words in this policy have special meanings wherever they appear. These words and their meanings are defined below. “ accidental loss or damage” means damage to, loss or destruction of your buildings or contents caused by an unintentional act, or an unforseen or uncontrollable incident. … “ storm ” means violent wind (including cyclones and tornadoes), thunderstorms and hail which may be accompanied by rain or snow. When we will not pay a claim under your policy This policy does not cover loss, liability, injury or damage Case No: 493952 Recommendation Page 5 of 11 ... f. Wear and tear arising out of depreciation, gradual deterioration, wear and tear; … Unless we state differently in your policy, we will not pay for: … d. loss or damage which is caused directly or indirectly by: … • rust, corrosion, algae, mould or mildew; or … 5.2 Key invoices Invoices Key points Applicant’s builder (NI) Invoice 30 - 03 - 2017  Replace existing solid deck with open trex composite decking ( 7.5 x 3.8m)  Remove existing floor tiles and FC sheet and joists, remove existing steel reinforced ballustrade that penetrates existing floor sheets, remove and replace 7.5 m long x310mm I beam, waterproof exterior where joists penetrate brickwork and cladding facade.  Make good  - 310mm x7.5 I beam  - Remove and Replace subfloor structure and brace up as required  - facia around deck and I beam  - Replacement of balustrade with white aluminium slats (as per front fence)  - Set, sand and paint the pitched cei ling above deck  Remove and dispose of all waste  $34,200.00  QBCC Home Warranty Insurance $462.70  $38,128.97 in total Applicant’s builder (NI) Letter 13 - 10 - 2017  In relation to the repair/replacement of the deck, the cost breakdown is listed below: • Set, sand and paint pitched ceiling $1750 inc gst • Aluminium balustrade instead of timber $2200 inc gst Case No: 493952 Recommendation Page 6 of 11 5.3 Key reports Record Key points FSP’s builder (BS) Report 2 - 02 - 2017  In my opinion, it would appear that damages have been present for a period of up to 10 years. An engineer maybe able to validate this if required by the degree of damage to the steel beam and the time hardwood timbers take to complet ely decay.  In my opinion, damages were caus ed by long term exposure to wat er entering the cavity of the deck and bulkhead surrounding the steel beam. It would appear water proofing to the posts and  sheet joins was inadequate / failed due to age or was never installed. It is likely every time it has rained water has entered causing the gradual deterioration o f the timber and steel components. FSP’s builder (BS) Report 2 - 02 - 2017  As the lining material to the underside of the deck had been removed by [IA] it was easy to see what has occurred.  It would appear by the damage sighted that water has been ent ering th e decking cavity and that of the supporting structural beam for many years which has resulted in the decay of supporting timbers and the rusting of the steel beam.  The rain water has entered around the supporting posts to the building and handrail, there i s also signs water has leaked through the joins of the Fibre cement sub - straight fitted to the joists which is tiled over. We suspect either a water proofing membrane was not installed at the time of construction or it has since failed due to age.  The stee l supporting beam which is a 300 x 165 I Beam shows sever rust damage directly below the penetrations in deck by the 100 x 100 steel post supporting both the upper roof and handrail. The hardwood joists (140 x 45) are also totally rotted through in the aff ected areas.  The damage is such that the deck and supporting beam will require removal and replacement. It is likely the slider door and cladding to the external wall of the dwelling will require removal and reinstatement to allow for the installation of w ater proof membrane to meet current building codes.  We believe the damage has been gradual in nature and has occurred over a significant period of time. Applicant’s engineer (KC) Letter 4 - 05 - 2017  An inspection was carried out on the existing beam under th e front main deck on 3/3/2017. This beam is excessively corroded and beyond repair. The amount of corrosion to this beam would have been Case No: 493952 Recommendation Page 7 of 11 occurring over at least the past 5 - 7 years.  The beam at the time of the inspection was clearly visible as the facade ha d been removed by the builder. The remaining framing around this beam would indicat e that the beam was not visible before the demolition works had commenc ed. Applicant’s builder (NI) Letter 13 - 10 - 2017  The existing tiled deck was most definitely affected b y a severe storm or the like to inflict the level initial damage to the subfloor. This would have been caused by a flexing of the structure which in turn cracked the tiles/glue and separat ed the sealant from the steel posts.  This damage would not have been picked up by any reas onable person whether it be a builder, or an engineer until it was determined that further inspection needed to occur and the sheeting demolished from under the deck to expose the joists and beam.  In relation to the integrity of t he existing deck, this would have been designed and built to building code of the time. FSP’s engineer (CR) Report 23 - 10 - 2017 Wind damage  It was claimed by the builder for the Insured (NI & BS, 13 October 2016) that the tiled deck was „most definitely a ffected by a severe storm or the like to inflict the level initial damage to the subfloor. This would have been caused by a flexing of the structure which in turn cracked the tiles/glue and separated the sealant from the steel posts‟.  We have reviewed the wind gust data documented by the Bureau of Meteorology for 2010 - 11 in the local area. The weat her station relative to the residence is at „Brisbane Airport‟ (station number 40842) located 9. 4 kms away. The largest wind gust recorded in the period from 1 De cember 2010 to 28 February 2011 was 72.4 km/hr on 17 December 2010 (see Appendix B, Tec hnical Data Supplement ).  We have calculated the design wind speed for the property as 186 km/hr (51.9 m/s) based on AS1170. 2 Structural design actions Part 2: Wind actio ns and a Terrain category of 2 for the location. The design wind speed for the property is two and a half times the wind speed for the wind event in 2010.  Calculation of the deflection of the floor joists due to the level of wind loading received in 2010 g ives a deflection of less than 1 mm at midspan, less than span/300 = 11.5 mm, which is the accepted deflection limit for timber floor joists. Similarly, Case No: 493952 Recommendation Page 8 of 11 calculation of the deflection of the steel beam due to the wind received in 2010 gives a deflection of less than 1 mm at midspan, less than span /300 = 24 mm.  It is our opinion that the level of wind loading received from the short term wind event in 2010 was much lower than the design wind loading. It is our opinion that the wind event was not the cause of damage to the deck and subsequent wat er ingress into the deck.  We have taken into consideration the effects of localised wind gusts which may be higher than the maximum wind gust measured at „Brisbane Airport‟. We are of the opinion a maximum wind gust lo cated at the Insured property, during the alleged storm event, was insignificant relative to the design wind speed of the structure. Water proof membrane  We have reviewed the reports and images from NI BS and there were no signs of a waterproof membrane in stallation observed on the original deck i.e. turn up of the membrane against the wall of the residence or around the steel posts or installation visible from under decking.  The current standard for the installation of a waterproof membrane is AS4654.2 - 200 9 Waterproof membrane systems for exterior use – Above ground Part 2: Design and installation, is applicable but did not exist when the residence was constructed.  The Australian standard for installation of a waterproof membrane at the time of construction of the residence in about 1996 was AS CA55 - 1970 Design and Installation of bituminous roofing. AS CA55 states: -  Timber 3.4.3 “The deck shall be rigid and so designed as to minimize any effects of shrinkage, warping and relative movements of the timber, an d care shall be taken to guard against conditions promoting decay, such as ingress of water”.  The top of the timber deck was clad with ceramic tiles. The grout between the tiles is not waterproof. The underlay to the tiles was fibre cement sheeting. The sheeting joins were not sealed and so the sheeting was not waterproof.  Deterioration of the cladding to the underside of the deck was observed in October 2016 (see Photograph 12) during the Nailed It inspection. The damage was observed at various locations around the deck. Corrosion damage from long term water ingress was observed at the front of the deck Case No: 493952 Recommendation Page 9 of 11 around the steel posts (see Photographs 7 & 11). Previous repairs were observed at the cracked tiles around the posts (see photographs 8 - 10). The tile aro und the southeast steel post was observed to be stepped vertically at the cracking and would have been visible over the long term to vis ual inspection. It is our opinion that water was penetrating the deck over the long term due to the ingress of water in to the deck and the damage to the tiling on the deck and sheeting to the underside of the deck was visible over the long term.  It is our opinion that if a water proof membrane had been installed, water ingress into the cavity of the deck would not have occ urred. Applicant’s engineer (KC) Letter 5 - 12 - 2017  An inspection was carried out on the existing beam under the front main deck on 3rd Marc h 2017. This beam is excessively corroded and bey ond repair. The amount of corrosion to this beam would have been occ urring over at least the past six to seven years.  The beam at the time of the inspection was clearly visible as the facade had been removed by the builder. The remaining framing around this beam would indicat e that the beam was not visible before the demol ition works had commenc ed.  A second inspection was carried out by a builder on 5th December 2017 to investigate the base of the existing columns to the front deck. These columns were found to be buried below ground by about 500mm and have a top fixing to a concrete footing below. The orient ation of the base plate and bolts is perpendicular to the beam above. The columns are 100x4.0 SHS and main deck beam running at deck level is 310UB40. The upper columns are 2.7m long and the bottom columns are 3 .2m long. The base fixing of the columns is pinned and the fixing of the lower columns to the main beam are also pinned.  Due to the pinned connections the stability of the deck is wholly reliant on the bracing in the floor and ceiling.  The resistance by the floorin g and ceiling, is a similar action to wall bracing, which will trans fer the wind load as a shear force back to the front wall of the dwelling. This in tum creates local stresses in the comers of the deck. As the upper columns are within the comer they loca lly increase this stress concentration due to the reduction in total area where they are locat ed.  Without knowing how the tiles and FC sheeting Case No: 493952 Recommendation Page 10 of 11 were fixed, we can only comment on a possible cause. A severe storm event will impose loads and the deck/ceiling must deflect to take up these applied loads. As the flooring and tiles are brittle any small amount of deflection could potentially cause a fracture/crack in the tile and thus allow water ingress into the floor cavity. The builder before demolition notice d cracking locally around the base of the upper columns in the tiles and these could have pot entially been from these movements. Once this has occurred any further rain and/or storm events will allow continued wat er ingress into the concealed floor space. FSP’s engineer (CR) Report 7 - 1 - 2018  The deck was 7.2 metres long across the front of the residence and projects outwards approximately 3.5 metres from the fac e of the residence. The deck was originally sheeted wit h fibre cement sheeting under the tiling t o the top of the deck, and under the floor joists. The floor joists are attached to the residence at 450 mm centres. It is our opinion that the structural configuration of the deck cantilevering horizontally 3.5 metres while 7.2 metres deep, would not offe r any significant deflection that would cause stress at the connections of the support columns to the deck from flex ure of the columns. The arrangement of the deck attached to the face of the residence at every joist and sheeted top and bottom has formed a very stiff projection from the residenc e. There was no damage noted at the face of the residence that could be expected from horizontal movement of the deck. It is our opinion that the deck did not undergo any horizontal movement relative to the residence due to the wind event. It is our opinion that that there was no horizontal stress induced into the columns during the wind event and that there was no inc reas e in “local stresses in the corners of the deck” during the wind event, due to horizontal movemen t of the deck.  The initial CR report calculates the midspan deflection of the floor joists due to the wind event to be less than 1 mm, far less than the accept ed design deflection limit for the timber floor joists, of over 11 mm. It is our opinion that def lection of the deck due to the storm event is not the cause of the fractures in the tiles.  The Australian Standard for installation of a waterproof membrane at the time of construction of the residence in about 1996 was AS CA55 - 1970 Design and Installation of bituminous roofing. AS Case No: 493952 Recommendation Page 11 of 11 CA55 states: -  Timber 3.4.3 “The deck shall be rigid and so designed as to minimize any effects of shrinkage, warping and relative movements of the timber, and care shall be taken to guard against conditions promoting decay, such as ingress of water”.  As stated in the initial CR report, it is our opinion that water was penet rating the deck over the long term due to the ingress of water in to the deck and the damage to the tiling on the deck and sheeting to the underside of the deck was visible over the long term. It is our opinion that if care had been taken during construction by the installation of a water proof membrane (as recommended by the Australian Standard), water ingress into the floor cavity of the deck would not have occ urred.  The cracking to the tiles around the columns was observed in the BS images (dat ed Feb 2017, see Appendix A, Photographs 8 - 10) in the initial CR report to have been subject to previous repair attempts by the Insured using sealant.  Australian Standard AS3958.1 - 1991 Ceramic tiles - Guide to the installation of ceramic tiles (relevant at time of construction), requires the following:  “Intermediate movement joints should be provided in evenly - spaced positions at approximately 4.5 m centres, or at locatio ns where stress might reasonably be expected in; internal floors, where any dimension exceeds 9m or 6m if subjected to sunlight; and external floors where any dimension exceeds 4.5m”.  There were no movement joints in the tiling to the deck observed in the photographs supplied. The overall length of the deck was 7.2 metres and so should have had at least one movement joint in that length. It is our opinion that the cracking in the tiles at the columns could have been caused by the absence of movement jointin g in the tiling.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.