The applicants claimed about $60,000 for cracking and movement damage to their veranda, which they attributed to a leaking pipe. The FSP denied the claim as earth movement damage, and AFCA agreed the leak was not the proximate cause.
On the balance of the engineering evidence, the damage was more consistent with naturally occurring earth movement from drying reactive clay soils than with the leaking pipe, so the earth movement exclusion applies.
Issues
- Claim denial primary · not upheld“The damage was caused by naturally occurring earth movement, which is excluded from cover, so the FSP is not liable.”
- Inadequate claim investigation secondary · not upheld“Applicants alleged the FSP's engineers did not properly investigate the cause of the damage; AFCA rejected this concern.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 493529 Determination Page 1 of 6
Case number: 493529 30 April 2018
1 Overview
1.1 Dispute
The applicants lodged a claim under their home insurance policy with the financial
services provider (FSP) for cracking and movement damage to the veranda at their
home. The applicants consider the damage was caused by the effects of water
leaking from a broken pipe under the concrete veranda slab.
The FSP denied the claim on the basis that the damage was not caused by the
leaking pipe (or by any other insured event under the policy). The FSP says the
damage was caused by naturally occurring earth movement, which is excluded from
cover under the policy.
The applicants dispute the FSP’s decision and seek cover for the cost of repairing
the damage (estimated at approximately $60,000).
1.2 Issues and key findings
Is the FSP liable for the damage to the applicants’ property ?
The available information establishes that the damage was caused by naturally
occurring earth movement and not by water leaking from the broken pipe.
Damage caused in this manner is excluded from cover under the policy. Accordingly,
the FSP is not liable for the applicants’ claim.
1.3 Determination
This determination is in favour of the FSP.
The FSP is not liable for the applican ts’ claim .
Case No: 493529 Determination Page 2 of 6
2 Reasons for determination
2.1 Is the FSP liable for the damage to the applicants’ property ?
Policy provides cover for insured events subject to exclusions
The applicants are required to show that, on the balance of probabilities, they have
suffered a loss caused by a risk insured against under the policy. This is known as a
valid (or prima facie ) claim.
If the applicants are able to establish a prima facie claim, then the onus shifts to the
FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy or is otherwise entitled to deny the claim.
The applicants’ policy provides cover for damage caused by the insure d events listed
in the policy, subject to the conditions and exclusions set out in the policy. The
insured events include liquid leaking from a fixed pipe.
The policy contains a general exclusion for damage caused by naturally occurring
earth movement of any form (other than landslide or subsidence in certain limited
circumstances).
FSP’s liability depends on proximate cause of damage
The reports prepared by the engineers who inspected the applicants’ property
confirm that there is cracking and movement damage to the slate covered concrete
veranda slab located to the east side of the house.
The veranda slab is approximately 30 metres long, 6 metres wide and 90 millimetres
thick. There are several cracks in the slate tiled surface and the concrete slab of
veranda, the edge of the slab has pulled away from the east side of the house and
there are gaps at the interfaces between the infill brickwork of veranda and the
house.
The applicants consider the cracking and movement damage was caused by water
leaking from a damaged pipe under the concrete veranda slab, which supplied water
to the house from a rainwater storage tank. The leak was located in a section of the
pipe directly adjacent to the kitchen on the east side of the house. It was discovered
and repaired in January 2016.
The FSP disputes that the cracking and movement damage to the property was
caused by the leaking drain pipe (or by any other event insured against under the
policy).
The FSP says the damage occurred as a result of naturally occurring earth
movement, due to long-term drying of the soils under the veranda slab as a result of
seasonal changes and the effect of nearby trees.
Damage caused in this manner is not covered under the policy.
Case No: 493529 Determination Page 3 of 6
Accordingly, in order to determine the FSP’s liabili ty for the claimed damage, it is
necessary to identify the proximate cause of the damage (that is, the real, effective or
dominant cause).
Engineers have provided conflicting opinions
Both the engineers engaged by the FSP (FM and MC) and the engineer engaged by
the applicant (DC) agree that the damage was caused by earth movement due to
changes in the moisture content of the reactive clay soils at the property.
However, the engineers have provided conflicting opinions about the cause of the
variations in moisture content and the mechanism by which the damage occurred.
The first engineer (FM) appointed by the FSP concluded that the damage had
occurred as a result of:
the shallow founding depth of the concrete verandah slab, and
settlement (downwards movement) of the ground supporting the east side of the
slab due to long-term drying of the foundation soils caused by seasonal
changes and the drying effects of nearby trees.
FM advised that none of the damage had been caused by the leaking pipe. FM
considered that the observed damage was consistent with settlement (downwards
movement) caused by the drying out of the reactive clay soils, rather than heave
(upwards movement) which occurs when the soils are exposed to excessive
moisture.
FM considered that settlement had been occurring for an extended period of time,
based on the debris which had accumulated in the crack in the veranda slab (under
the slate tiles). He also observed settlement of the exposed ground in other areas.
The applicants’ engineer (DC) disputes FM’s findings about the cause of the damage
to the veranda. DC acknowledged that the house had experienced settlement in
other areas, due to naturally occurring changes in the moisture content of the
foundation soils as a result of seasonal variations, exacerbated by the drying effects
of tree roots.
DC attributed damage observed to the north, south and west sides of the house (and
the north-west corner of the veranda) as having been caused by these factors.
However, DC considered that the damage which had been caused to the veranda at
the east side of the house was qualitatively different and had been caused by the
leaking rainwater supply pipe.
DC advised that the contour patterns derived from his floor level surveys displayed
two dominant patterns affecting the veranda area which were characteristic of soil
swelling (heave) due to an increase in the moisture content of the reactive clay soils
caused by a deep moisture source.
As a result of the conflicting views expressed by FM and DC, the FSP appointed a
third engineer (MC) to conduct a desktop review of the initial reports prepared by FM
and DC.
Case No: 493529 Determination Page 4 of 6
MC conclusions were consistent with FM’s findings that the damage to the veranda
had been caused by naturally occurring earth movement in the form of settlement
(downwards movement) due to the drying out of the clay foundation soils.
Damage was not caused by leaking pipe
I have carefully reviewed the extensive information provided by the parties including:
the initial reports prepared by the engineers (FM, DC and MC)
the subsequent responses provided by FM and DC to each other’s reports
the further response provided by DC following the issue of the FOE
recommendation, and
the results of the soil tests and level surveys conducted by DC.
Having done so, I am not satisfied that the cracking and movement damage to the
applicants’ veranda was caused by the leaking pipe.
I accept that there was a leak in the pipe which caused moisture to enter the
foundation soils.
However, I consider that the nature and location o f the cracking and movement
damage is more consistent with it having been caused by naturally occurring earth
movement over an extended period of time, due to the drying of the highly reactive
foundation soils under the concrete veranda slab.
In this respect, I note that the available information (including the many colour
photographs provided) indicates that:
the veranda slab was founded on directly on bedding sand on the ground
surface, making it more prone to differential settlement than the house itself
the floor level surveys do not show localised heave in the immediate vicinity of
the broken pipe (such as would be expected, had the foundation soils been
affected by excess water leaking from the pipe)
the cracking and movement damage to the veranda is not closely correlated with
the location of the leaking pipe and there is no cracking damage evident to the
external brickwork or internal walls in the area of the house located immediately
adjacent to the leaking pipe
there is evidence of differential settlement of the ground along the east side of the
veranda slab, as evidenced by the separation of the rainwater downpipes as the
ground dropped in this area.
In his reports, the applicants’ engineer (DC) has relied on the results of his floor level
surveys.
The FSP’s engineer (FM) does not disagree with the levels recorded by DC.
However, the two engineers disagree about the nature of the contour patterns
derived from the objective level survey results.
While DC identified two discrete contour patterns, FM considered there was only one
pattern of relative settlement towards the trees located at the perimeter of the house.
Care needs to be taken in interpreting floor level surveys in this context, as such
surveys only show the levels of particular areas relati ve to each other. While this
Case No: 493529 Determination Page 5 of 6
establishes that differential movement has occurred, it does not necessarily establish
whether particular areas have heaved or settled.
In the present case, I am not satisfied that the conclusions reached by DC based on
the floor levels are consistent with the damage having been caused by the leaking
pipe under the veranda slab.
Among other things, DC acknowledged that the highest point reflected in the level
surveys is not located in the area near the leaking pipe, but south o f the leak site.
While DC posited that moisture may have travelled along a pipe trench, there is no
independent evidence to support this. Likewise, while DC referred to a possible
second leak near the south-east corner of the lounge, there is limited information
available regarding this leak.
DC has also queried FM’s conclusion that the several trees located in close proximity
to the east side of the slab would have had a drying effect on the soils nearby. DC
notes that these trees are crabapple trees which have non-invasive roots. However,
the limited reach of the roots would not necessarily preclude them from having a
drying effect, given the location of the trees.
The applicants have raised concerns that the FSP’s engineers did not properly
investigate the cause of the damage. They say FM relied on visual observations only
and DC was the only engineer who undertook soil testing and level surveys.
However, the outcome of DC’s investigations were consistent with many of the
observations made by the FM – in particular, that the foundation soils were highly
reactive and that the veranda slab was relatively lower than the east side of the
house.
As outlined above, the two engineers disagreed about the appropriate conclusions to
be drawn from the investigations about the mechanism by which the damage had
occurred.
FSP is not liable for applicants’ claim
For the reasons outlined above, I consider the cracking and movement damage to
the applicants’ property was not caused by the effects of water leaking from the
damaged pipe (or by any other insured event under the policy).
The available information establishes the damage was caused by naturally occurring
earth movement, which is excluded from cover under the policy.
Accordingly, the FSP is not liable for the applicants’ claim.
Case No: 493529 Determination Page 6 of 6
3 Supporting information
3.1 FOS approach to this dispute
This dispute was the subject of a recommendation issued on behalf of the Financial
Ombudsman Service (FOS) on 19 December 2017. The recommendation was
rejected by the applicants.
This dispute has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions (which are not binding).
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered (whether or not it is expressly referenced in this determination).
3.2 Terms of policy
Subject Terms
Cover for
insured
events
…we cover your home and contents when covered under this policy for loss or
damage at the insured address caused by an insured event during the period of
insurance .
Escape of
liquid
We cover
Loss or damage caused by liquid leaking, overflowing or bursting from any of the
following …
any drain, fixed pipes, roof gutters or guttering and rainwater downpipes,
drainage and sewage systems …
General
exclusions
You are not covered under any section of this policy for damage, loss, cost or
legal liability that is caused by, arises from or involves:
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage
or any other earth movement, but we will cover landslide or subsidenc e that is
specifically covered under the following ins ured events:
Storm …
Flood …
Earthquake and Tsunam i …
Explosion …
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.