Home / Financial Firm (Unknown - Insurer) / Determination 493529

Determination 493529

claim_denial

FirmFinancial Firm (Unknown - Insurer)
Decided2018-04-30
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$60,000
SourceAFCA PDF

Summary

The applicants claimed about $60,000 for cracking and movement damage to their veranda, which they attributed to a leaking pipe. The FSP denied the claim as earth movement damage, and AFCA agreed the leak was not the proximate cause.

On the balance of the engineering evidence, the damage was more consistent with naturally occurring earth movement from drying reactive clay soils than with the leaking pipe, so the earth movement exclusion applies.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 493529 Determination Page 1 of 6 Case number: 493529 30 April 2018 1 Overview 1.1 Dispute The applicants lodged a claim under their home insurance policy with the financial services provider (FSP) for cracking and movement damage to the veranda at their home. The applicants consider the damage was caused by the effects of water leaking from a broken pipe under the concrete veranda slab. The FSP denied the claim on the basis that the damage was not caused by the leaking pipe (or by any other insured event under the policy). The FSP says the damage was caused by naturally occurring earth movement, which is excluded from cover under the policy. The applicants dispute the FSP’s decision and seek cover for the cost of repairing the damage (estimated at approximately $60,000). 1.2 Issues and key findings Is the FSP liable for the damage to the applicants’ property ? The available information establishes that the damage was caused by naturally occurring earth movement and not by water leaking from the broken pipe. Damage caused in this manner is excluded from cover under the policy. Accordingly, the FSP is not liable for the applicants’ claim. 1.3 Determination This determination is in favour of the FSP. The FSP is not liable for the applican ts’ claim . Case No: 493529 Determination Page 2 of 6 2 Reasons for determination 2.1 Is the FSP liable for the damage to the applicants’ property ? Policy provides cover for insured events subject to exclusions The applicants are required to show that, on the balance of probabilities, they have suffered a loss caused by a risk insured against under the policy. This is known as a valid (or prima facie ) claim. If the applicants are able to establish a prima facie claim, then the onus shifts to the FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion under the policy or is otherwise entitled to deny the claim. The applicants’ policy provides cover for damage caused by the insure d events listed in the policy, subject to the conditions and exclusions set out in the policy. The insured events include liquid leaking from a fixed pipe. The policy contains a general exclusion for damage caused by naturally occurring earth movement of any form (other than landslide or subsidence in certain limited circumstances). FSP’s liability depends on proximate cause of damage The reports prepared by the engineers who inspected the applicants’ property confirm that there is cracking and movement damage to the slate covered concrete veranda slab located to the east side of the house. The veranda slab is approximately 30 metres long, 6 metres wide and 90 millimetres thick. There are several cracks in the slate tiled surface and the concrete slab of veranda, the edge of the slab has pulled away from the east side of the house and there are gaps at the interfaces between the infill brickwork of veranda and the house. The applicants consider the cracking and movement damage was caused by water leaking from a damaged pipe under the concrete veranda slab, which supplied water to the house from a rainwater storage tank. The leak was located in a section of the pipe directly adjacent to the kitchen on the east side of the house. It was discovered and repaired in January 2016. The FSP disputes that the cracking and movement damage to the property was caused by the leaking drain pipe (or by any other event insured against under the policy). The FSP says the damage occurred as a result of naturally occurring earth movement, due to long-term drying of the soils under the veranda slab as a result of seasonal changes and the effect of nearby trees. Damage caused in this manner is not covered under the policy. Case No: 493529 Determination Page 3 of 6 Accordingly, in order to determine the FSP’s liabili ty for the claimed damage, it is necessary to identify the proximate cause of the damage (that is, the real, effective or dominant cause). Engineers have provided conflicting opinions Both the engineers engaged by the FSP (FM and MC) and the engineer engaged by the applicant (DC) agree that the damage was caused by earth movement due to changes in the moisture content of the reactive clay soils at the property. However, the engineers have provided conflicting opinions about the cause of the variations in moisture content and the mechanism by which the damage occurred. The first engineer (FM) appointed by the FSP concluded that the damage had occurred as a result of:  the shallow founding depth of the concrete verandah slab, and  settlement (downwards movement) of the ground supporting the east side of the slab due to long-term drying of the foundation soils caused by seasonal changes and the drying effects of nearby trees. FM advised that none of the damage had been caused by the leaking pipe. FM considered that the observed damage was consistent with settlement (downwards movement) caused by the drying out of the reactive clay soils, rather than heave (upwards movement) which occurs when the soils are exposed to excessive moisture. FM considered that settlement had been occurring for an extended period of time, based on the debris which had accumulated in the crack in the veranda slab (under the slate tiles). He also observed settlement of the exposed ground in other areas. The applicants’ engineer (DC) disputes FM’s findings about the cause of the damage to the veranda. DC acknowledged that the house had experienced settlement in other areas, due to naturally occurring changes in the moisture content of the foundation soils as a result of seasonal variations, exacerbated by the drying effects of tree roots. DC attributed damage observed to the north, south and west sides of the house (and the north-west corner of the veranda) as having been caused by these factors. However, DC considered that the damage which had been caused to the veranda at the east side of the house was qualitatively different and had been caused by the leaking rainwater supply pipe. DC advised that the contour patterns derived from his floor level surveys displayed two dominant patterns affecting the veranda area which were characteristic of soil swelling (heave) due to an increase in the moisture content of the reactive clay soils caused by a deep moisture source. As a result of the conflicting views expressed by FM and DC, the FSP appointed a third engineer (MC) to conduct a desktop review of the initial reports prepared by FM and DC. Case No: 493529 Determination Page 4 of 6 MC conclusions were consistent with FM’s findings that the damage to the veranda had been caused by naturally occurring earth movement in the form of settlement (downwards movement) due to the drying out of the clay foundation soils. Damage was not caused by leaking pipe I have carefully reviewed the extensive information provided by the parties including:  the initial reports prepared by the engineers (FM, DC and MC)  the subsequent responses provided by FM and DC to each other’s reports  the further response provided by DC following the issue of the FOE recommendation, and  the results of the soil tests and level surveys conducted by DC. Having done so, I am not satisfied that the cracking and movement damage to the applicants’ veranda was caused by the leaking pipe. I accept that there was a leak in the pipe which caused moisture to enter the foundation soils. However, I consider that the nature and location o f the cracking and movement damage is more consistent with it having been caused by naturally occurring earth movement over an extended period of time, due to the drying of the highly reactive foundation soils under the concrete veranda slab. In this respect, I note that the available information (including the many colour photographs provided) indicates that:  the veranda slab was founded on directly on bedding sand on the ground surface, making it more prone to differential settlement than the house itself  the floor level surveys do not show localised heave in the immediate vicinity of the broken pipe (such as would be expected, had the foundation soils been affected by excess water leaking from the pipe)  the cracking and movement damage to the veranda is not closely correlated with the location of the leaking pipe and there is no cracking damage evident to the external brickwork or internal walls in the area of the house located immediately adjacent to the leaking pipe  there is evidence of differential settlement of the ground along the east side of the veranda slab, as evidenced by the separation of the rainwater downpipes as the ground dropped in this area. In his reports, the applicants’ engineer (DC) has relied on the results of his floor level surveys. The FSP’s engineer (FM) does not disagree with the levels recorded by DC. However, the two engineers disagree about the nature of the contour patterns derived from the objective level survey results. While DC identified two discrete contour patterns, FM considered there was only one pattern of relative settlement towards the trees located at the perimeter of the house. Care needs to be taken in interpreting floor level surveys in this context, as such surveys only show the levels of particular areas relati ve to each other. While this Case No: 493529 Determination Page 5 of 6 establishes that differential movement has occurred, it does not necessarily establish whether particular areas have heaved or settled. In the present case, I am not satisfied that the conclusions reached by DC based on the floor levels are consistent with the damage having been caused by the leaking pipe under the veranda slab. Among other things, DC acknowledged that the highest point reflected in the level surveys is not located in the area near the leaking pipe, but south o f the leak site. While DC posited that moisture may have travelled along a pipe trench, there is no independent evidence to support this. Likewise, while DC referred to a possible second leak near the south-east corner of the lounge, there is limited information available regarding this leak. DC has also queried FM’s conclusion that the several trees located in close proximity to the east side of the slab would have had a drying effect on the soils nearby. DC notes that these trees are crabapple trees which have non-invasive roots. However, the limited reach of the roots would not necessarily preclude them from having a drying effect, given the location of the trees. The applicants have raised concerns that the FSP’s engineers did not properly investigate the cause of the damage. They say FM relied on visual observations only and DC was the only engineer who undertook soil testing and level surveys. However, the outcome of DC’s investigations were consistent with many of the observations made by the FM – in particular, that the foundation soils were highly reactive and that the veranda slab was relatively lower than the east side of the house. As outlined above, the two engineers disagreed about the appropriate conclusions to be drawn from the investigations about the mechanism by which the damage had occurred. FSP is not liable for applicants’ claim For the reasons outlined above, I consider the cracking and movement damage to the applicants’ property was not caused by the effects of water leaking from the damaged pipe (or by any other insured event under the policy). The available information establishes the damage was caused by naturally occurring earth movement, which is excluded from cover under the policy. Accordingly, the FSP is not liable for the applicants’ claim. Case No: 493529 Determination Page 6 of 6 3 Supporting information 3.1 FOS approach to this dispute This dispute was the subject of a recommendation issued on behalf of the Financial Ombudsman Service (FOS) on 19 December 2017. The recommendation was rejected by the applicants. This dispute has been determined based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions (which are not binding). There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any issues raised by the other. All of the material provided by the parties has been reviewed and considered (whether or not it is expressly referenced in this determination). 3.2 Terms of policy Subject Terms Cover for insured events …we cover your home and contents when covered under this policy for loss or damage at the insured address caused by an insured event during the period of insurance . Escape of liquid We cover Loss or damage caused by liquid leaking, overflowing or bursting from any of the following …  any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems … General exclusions You are not covered under any section of this policy for damage, loss, cost or legal liability that is caused by, arises from or involves: Ground movement erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover landslide or subsidenc e that is specifically covered under the following ins ured events:  Storm …  Flood …  Earthquake and Tsunam i …  Explosion …

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.