Text of the determination
Determination
Case No: 492366 Determination Page 1 of 11
Case number: 492366 1 August 2018
1 Overview
1.1 Dispute
The applicant held a landlord building insurance policy with the financial services
provider (FSP). He lodged a claim in January 2016 after substantial movement
related cracking was identified to the property.
The FSP declined the claim and says the proximate cause of the damage was the
long-term man made leakage from a defective sewer pipe. The FSP says that the
exclusions relating to defective workmanship, lack of maintenance, wear and tear
and earth movement apply to defeat the applicant’s claim.
1.2 Issues and key findings
Is the FSP entitled to deny the applicant’s claim?
The Panel is satisfied the damage was caused by the gradual escape of liquid from
the defective sewer pipe and resulting soil movement. The FSP is entitled to rely on
the terms and conditions of the policy to refuse payment of the claim.
Is the applicant entitled to compensation for consequential loss or non-
financial loss?
The P anel is satisfied that the FSP’s handling of the claim was reasonable in the
circumstances and did not lead to any undue delay. The applicant is not entitled to
compensation under paragraph 9.3 of the Terms of Reference (TOR) for
consequential or non-financial loss.
Is the FSP required to contribute to the applicant’s professional costs
incurred?
The FSP must contribute, pursuant to paragraph 9.4 of the TOR, $3,000 towards the
applicant’s professional costs incurred in the course of this dispute.
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitled to rely upon the terms and conditions of the policy to refuse
payment of the applicant’s claim.
The FSP must pay the applicant $3,000 pursuant to paragraph 9.4 of the TOR being
contribution to the applicant’s professional costs incurred.
Case No: 492366 Determination Page 2 of 11
2 Reasons for determination
There has been a full exchange of all material information relied on for the purposes
of this Determination and each party has had the opportunity to address any issues
raised by the other.
Due to the nature of the dispute, it has been referred directly to a Panel for
Determination, in line with the Operational Guidelines to the FOS Terms of
Reference. The Panel consists of an Ombudsman and two representatives with
consumer and insurance experience.
The Panel has reviewed and considered all of the material provided by the parties.
While the parties have raised numerous issues in their submissions, for the purposes
of this Determination, the Panel has restricted its commentary to those issues which
it considers directly relevant to the outcome only.
This determination is based on what is fair in the circumstances, having regard to the
relevant law, good industry practice, codes of practice and previous Financial
Ombudsman Service (FOS) decisions.
2.1 Is the FSP entitled to deny the applicant’s claim?
The applicant has the onus to prove a claim within the terms of the policy
The applicant is required to show, on the balance of probabilities, he suffered a loss
caused by a risk insured against under the policy. This is known as a valid ( prima
facie) claim.
The policy provides cover for loss or damage caused by a number of listed events
including loss or damage caused accidental escape of liquid from any fixed pipe.
The policy contains general exclusions for damage caused by:
defects in design, structure, materials, workmanship or construction
earth or soil movement, landslide, subsidence, or erosion
settling, expansion or shrinkage
wear and tear, gradual deterioration
tree roots
Further, in respect of the event of escape of liquid, a specific exclusion applies:
loss or damage caused by gradual escape of liquid which is evident and which
you failed to rectify.
Damage identified in November 2015
The home was tenanted and the applicant says his real estate agent first notified him
of this damage in late 2015.
The tenants vacated the property on 5 January 2016 because they felt it was unsafe.
The FSP arranged for its building consultant ‘A’ to assess the property. In a report
dated 22 January 2016, A confirmed the property was uninhabitable due to the extent
of the structural damage.
Case No: 492366 Determination Page 3 of 11
The applicant initially stated he believed a storm event on 12 November 2015 caused
cracking at his property. After plumbing and other investigations were completed, the
applicant concluded escape of liquid from earthenware pipes beneath the building
caused the damage.
The relevant insured event for this claim is damage caused by escape of liquid from
fixed pipes.
Each party consulted experts to determine the proximate cause of the damage
The parties have each retained experts to inspect and report on the cause of the
structural and cracking damage throughout the property. Details of the reports are set
out under section 3.2 of this determination.
The available evidence indicates the applicant’s property is approximately 40 years
old and has been constructed on an area of highly reactive (H2) clay soil on a sloping
site.
The Panel has fully considered each parties’ expert reports. The experts substantially
agree:
there are significant defects to both the sewerage and storm water drainage
systems at the property with both being in poor condition
breaks and blockages were identified throughout both systems including
extensive infiltration by tree roots, and build-up of leaf, dirt and other debris
there is a defective PVC sewer joint under the stairway in the subfloor area
allowing escape of liquid from the main bathroom to the sewer line
it is likely the storm water system requires replacement and additional
downpipes are required to assist in management of volume of rainwater away
from the property
there has been no single one off event that has caused the loss with movement
evident up to two years prior to November 2015, and continuing throughout the
life of the claim
extent of sewerage staining, root infiltration and soil moisture levels and the
presence of rot in the flooring of the bathroom and cupboard of the front
bedroom indicate that leaking has been occurring for an extended period of
time.
Both parties’ plumbers have identified a defective PVC sewer junction beneath the
property that has no evidence of glue or other sealant. A leak has been identified at
this location. On this basis, the FSP alternatively relies on the general policy
exclusion for defects in design or workmanship.
The Panel also notes real estate trust ledger reports for the property indicate a
history of water/plumbing related issues at the property in recent years, including:
2011 - Removal of mould, inspect dampness in carpet, Inspect water leak
2013 - Clear blockage in drain
2014 - Choked sewer drain x2 events
This further confirms there were issues of mould/dampness and sewer leaks in the
years preceding claim lodgment. This is consistent with long-term water leaks which
the applicant ought to have been aware of. T he applicant’s engineer also considers
Case No: 492366 Determination Page 4 of 11
that movement at the property had been occurring for up to 24 months prior to
lodgment of the subject claim.
Policy exclusions apply to the claim
The policy provides general exclusions for damage caused by:
wear and tear, gradual deterioration
tree roots
defects in design, structure, materials or construction
earth or soil movement (other than earthquake) including landslide, subsidence,
or erosion
settling, expansion, shrinkage or vibration.
In respect of the event of escape of liquid, the specific exclusion applies for:
loss or damage caused by gradual escape of liquid which is evident and which
you failed to rectify.
It is clear there has been a gradual of escape of liquid from the earthenware drainage
pipes at the property. The greatest amount of movement in the structure is along the
southern boundary corresponding with the location of the sewer and drainage lines,
including the identified defective PVC joint. The expert evidence indicates the
damage would have been evident for some time prior to the claim lodgment.
These leaks, coupled with deficiencies in the storm water system and possibly leaks
within the bathroom fixtures themselves (evidenced by rot to the bathroom floor)
have caused changes in the moisture content of the foundational soils.
Given the reactive nature of these soils, this has caused differential movement and a
reduction in the load bearing capacity of the soil and resultant movement of the
foundations at the property.
FSP not liable for the damage to the applicant’s property
For the reasons outlined above, the Panel is satisfied the proximate cause of the
damage to the applicant’s property was soil movement due to gradual escape of
liquid resulting from wear and tear, gradual deterioration and tree root infiltration of
the sewerage and storm water systems. The damage caused in this manner is
excluded under the policy.
Applicant’s policy does not include cover for loss of rent
As outlined above, the property was deemed inhabitable in early 2016, and the
tenants had elected to vacate shortly prior to this time.
The applicant seeks to recover loss of rent for an 18-month period (5 January 2016 –
27 July 2017, being the settlement date for the sale of the property) totaling $29,880.
The policy held by the applicant is a building and contents policy. Loss of rent is
generally an additional benefit reserved for policies containing landlord cover. Loss of
rent is not a benefit under the applicant’s policy.
Case No: 492366 Determination Page 5 of 11
2.2 Is the applicant entitled to compensation for consequential loss or
non-financial loss?
FOS may award consequential loss in certain circumstances
Under paragraph 9.3 of the TOR FOS may award compensation for an applicant’s
direct financial loss up to $309,000 and for consequential loss up to $3,300.
FSP ’s conduct did not cause a pplicant’s consequential losses
The applicant says due to the FSP’s decision to decline the claim and the length of
the claims process it was necessary for him to sell the property in its damaged state
as he was unable to finance the repairs himself. The applicant believes this was his
only viable option in the circumstances.
The applicant claims he has suffered a consequential loss $162,000 for selling the
property undervalue and in addition, loss of future rental income and capital gain
being forced to sell the property.
It is arguable that the difference in sale price achieved due to the damage is a
consequential loss arising from the damage. However, as the policy does not
respon d to the applicant’s claim the P anel does not accept that the reduced sale
price or loss has been caused by the FSP or by the FSP’s conduct.
The applicant is not entitled to compensation for non-financial loss
Paragraph 9.3 of the TOR also allows FOS to compensate an applicant for non-
financial loss (capped at $3,000) only where there has been:
an unusual amount of physical inconvenience
time taken to resolve a situation
interference with the applicant’s expectation of enjoyment or peace of mind.
The applicant appointed his own engineer to inspect the property in November 2015
and lodged his claim in January 2016. The FSP after the appointment of investigators
determined in June 2016 that it would deny the claim. The applicant sought a review
of this denial and eventually provided the FSP with a copy of the engineer’s report in
October 2016. This was approximately four months after the engineer had prepared
the report.
The FSP, given the extent of damage to the property, conducted further
investigations in view of the additional material provided by the applicant. The Panel
accepts that the FSP was entitled to fully investigate the cause of the damage and to
consider and respond to the additional information provided by the applicant.
The Panel accepts this would have a stressful time for the applicant however the
P anel does not believe the FSP’s conduct was unreasonable in the circumstances.
The P anel is not satisfied that the FSP’s handling of the claim has caused an unusual
amount of physical inconvenience or time taken to resolve this dispute.
Case No: 492366 Determination Page 6 of 11
2.3 Is the FSP liable to contribute to the applicant’s professional costs?
FSP required to contribute to cost of applicant for expert reports
Paragraph 9.4 of the TOR, provides that FOS may decide an FSP contributes up to
$3,000 to the professional costs incurred by an applicant in the course of a dispute.
The applicant claims $5,651 being the cost of his engineering/plumbing reports.
The reports obtained by the applicant ultimately confirmed the extent and nature of
the damage and assisted the Panel in the determination of this dispute . The reports
were reasonably obtained by the applicant in pursuing his claim and were of
assistance to the FSP.
In the circumstances the Panel considers it fair that the FSP contribute $3,000 to the
applicant ’ s professional costs subject to the applicant providing the relevant
invoices/receipts.
Case No: 492366 Determination Page 7 of 11
3 Supporting information
3.1 Terms of policy
Subject Terms
Insured events We will insure your building and contents at the site against loss or damage
caused by the following events if they occur during your period of ins urance.
…
Escape of liquid
Covered
Loss or damage caused accidental escape of liquid from any fixed pipe, fixed
tank, waterbed or fis h tank or fixed items used to hold the liquid.
We will al so pay reasonable ex ploratory costs in locating the source of the
damage, provided we have agreed to pay for the loss or damage caused by
the escape of liquid.
Not Covered
Loss or damage to the item from which the liquid escaped, and if the liquid
escaped from a shower recess, the cost of re - tiling the walls or floor of the
shower recess.
Repair or replacement of undamaged parts of your contents to match property
that has been repaired or replac ed.
Loss or damage caused by the gradual escape of liquid whic h is evidence d and
which you failed to rectify.
General
exclusions
Your policy does not cover any loss or damage that is caused by or arises from:
…
Maintenance and building
defects in design, structure, materials, workmans hip or construction
failure to keep the property insured watertight, well maintained, structurally
sound and secure
Wear and tear, and environmental conditions
…
earth or soil movement (other than earthquake) including landslide,
subsidence, or erosion
settling, expansion, shrinkage or vibration
tree roots
…
3.2 Expert evidence
Record Key points
FSP’s Building
Consultant (A)
1st Report
22 - 01 - 2015
Damage has been caused by general ground movement and is not resultant of
a single rain event
There is evidence of cracking throughout the dwelling that is believed to have
been occurring over an extended period of time
Case No: 492366 Determination Page 8 of 11
Record Key points
Major defects are present throughout the dwelling and foundations have failed
Recommend a structural engineer be appointed
FSP’s Building
Consultant (A)
5th Report
05 - 05 - 2016
Council records indicate residence was built during 1972/73
Foundations would have been of requisite standard at time of construction and
have been tested over time , however would not meet current Australian
Building Standards
In 1987 subfloor area of residence was rec ons tructed to include rumpus room,
study and a bathroom – this incorporated a 1400mm high core reinforced
concrete retaining wall
Foundational soil sampling indic ates the soil is ‘high H2 class, highly reactive’
The residenc e exhibits a significant extent of building distress (BD) – 60% of
the identified issues are structurally significant with concern for the structural
stability and safety of the west end of the residenc e
Cont ributing reasons for BD at the site are:
- poor drainage including blocked trench gate pit (TPG) along the north side
of the garage. Both trench and outlet pipe full of silt and leaf litter
- storm water runoff down the driveway formally drained by the TGP outlet
pipe
- storm water runoff can ent er the garage under the roller door – as the slab
is an infill slab runoff can overtime seep down into the subgrade/foundation
level and the adjacent brick walls
- ground moisture content (MC) variation from one part of the building to
another causing soil expansion in some areas and therefore differential
foundational movement
- at the north (front) and south (rear) west ends of the building it is believed
there has been some rotation of the strip footings due to MC differences in
the inside and outside of t he footings. This has con tributed to the brick wall
alig nment issues beside the main front and rear large windows and front
and laundry doors
the nature of the footings have less stiffness and capacity to cope with ground
MC conditions and H2 class reactiv e clays caused by poor drainage
App’s Engineer
(L )
1st Report
27 - 10 - 2016
The property features open extended concrete decks to the front and rear of
the dwelling with the damage that has occurred resulting in movement of the
decks awa y from the main structure of th e dwelling.
No evidence of major repairs to brickwork being carried out in the past
Damage is believed to be recent having occurred 18 - 24 mont hs prior to initial
inspection in November 2015 and worsening over past 12 months
Building has fu nctioned for at least 40 years therefore an event must have
triggered recent rapid deterioration
Inspection by plumber identified several blockages to sewerage lines beneat h
and adjacent to building
Separation of sewer joint has occurred on line coming fr om upstairs bathroom
and toilet as well as staining on externa l concrete path
Sewer lines have breakages in both earthenware and PVC services
Storm water lines are defective and require repair /replacement
Additional downpipes to be installed to ens ure ad equate drainage of roof water
Council sewer line running close to rear of building breac hed by tree roots and
likely to be leaking
Case No: 492366 Determination Page 9 of 11
Record Key points
Mode of building movement is cracking consistent with foundation settlement
at the rear of the building
Movement around th e front entrance, western end of the front patio , and inside
north west corner of garage is consistent with settlement along the southern
side of the building causing rot ation and lateral movement of the structure
downhill
Levels taken indic a t e significant settlement of up to 120mm along the southern
side with sha rp d ecline occurring mid - way through the building with levels
falling away to south – this corresponds with location of all sanitary drainage
Settlement along the southern side of the bu ilding has applied tension to the
building structure pulling apart the front (north) side resulting in lateral shift on
the damp course alo ng the front wall below the bedrooms, lateral separation
from the front patio and brickwork along the western wall
T he evident damage has been triggered by a leak in the plumbing that has
exacerbated building and foundation movement
This may have led to further breaks in drainage lines with ongoing movement
possible onc e leaking commenc ed
App’s Plumber
(F )
Report
18 - 08 - 2016
CCTV inspection of sewer line revealed significant damage to earthenware
service
Branch line from bathroom upstairs has multiple breaks throughout the service
and is in very poor condition
Inspection of external sewer lines from bathroom, kitche n and lau n dry revealed
breaks to pipes directly where service has come through under flooring
Inspection of storm wat er indicates very little water from current downpipe
system is getting to street kerb
Storm water service is blocked – possibly due to tre e roots
Recommended replacement of storm water to street kerb and addition of two
extra downpipes
FSP’s Building
Consultant (A)
6 th Report
10 - 11 - 2016
“4 major issues that I believe have played a big part if not caused this damage
to the building”
- No structural dowel tying the front and back concrete balconies to the main
structure of the house
- Main bearers beneath house have been cut up to 1m off the external walls
and replaced wit h steel beams however nothing tying floor joist to this
beam to stop house from moving. Bearers are just hanging off the brick
piers on the existing external piers and held in place by nails into the joists
- Internal block wall under the house is carrying a lot of the w e ight l o a d but is
not core filled with ce ment and no dowels could be seen in the brick holes
- There is a 70x35mm timber stud wall that the joists are sitting on that i s not
a loadbearing wall and would not be able to help with carrying the load of
the house
Cons ultant not able to warrant any wor ks on property due to structural
condition wi t hout installing a new metal sub - frame ske leton to tie the external
wall and frame work back together as the main bearers have been cut the
house will keep moving
FSP’s Plumber
(B)
Boundary shaft near back of carport contains brok en piec es of earthenware
and tree roots which have gained access
Case No: 492366 Determination Page 10 of 11
Record Key points
Report
15 - 12 - 2016
The council main has tree roots in and around the bottom of boundary shaft
and into main line
Marks on sewer line indicate previous blockage which has been cleared
Main line has extensive tree roots blocking it off
PVC join where bat hroom/toilet line enters house is not glued allowing leak of
water/sewerage at this point
Conc rete path near back steps is stained where sewer has flowed out of
toilet/bathroom line for some time
Lower bathroom near carport has had extensive repairs including shower, toilet
and basin indicating massive water leaks running into the sewer
Floor underneat h main bathroom has had water damage and is rotted out
Past r epairs evident to gyprock behind shower suggesting leaking copper pipe
and water flowing beneath house
Rear of house has water stains where water has overflowed the guttering and
back into the eaves – only two downpipes at the house both on the left side
Front left hand bedroom adjacent to downpipe has staining to carpet and top of
linen cupboard has rotted timber – water from gutters has therefore been
coming back into the eaves into that bedroom causing damage
Investigation of storm water pipe indicates that at about 3m in it is squashed
and the camera cannot access the pipe
Storm water pipe contains leave s , dirt and stones and is holding water
approximately 1 ½ meters from the street
Heading into line from street kerb there is a blockage about 2 meters in – the
camera cannot go any further as the pipe is squashed
Sunken pavement around the sewer boundary shaft at the rear of the property
is due to insufficient bedding grit and dirt and the escape of water from sewer
pipe joins - rain surface water also f alls towards this area and pools at this point
The sewer main boundary shaft has signs of tree roots entering at this point
blocking and holding wat er
the main sewer line from the boundary shaft point has had some repairs in the
past but the majority of t he main sewer line from the boundary shaft point has
several rubber ring joints that have tree roots entering the sewer line causing
blockages and causing the main line to be loaded with wat er and sewerage
the incursion of tree roots has been occurring fo r a minimum of twelve months,
possibly for t wo to three years
at the points tree roots are entering integrity of the line is compromised and
leaks are occurring at these points causing wet and damp around these areas
a new P V C pipe under the house is not sufficiently connected with no signings
of glue or primer on the join – this is allowing water/sewerage to escape in this
area
App’s Engineer
(V)
2nd Report
28 - 09 - 201 7
Initial damage has been caused as a result of escape of liquid from the
earthenware drainage pipes coming from under the building
These pipes exit the building in three locations, one of which is the location of
the yard gully under the tap which is broke n – it is at this location that the
greatest amount of movement in the structure has been recorded along the
outside edge of the southern boundary
The reason the balcony has pulled away is due to reduction in support/reduced
bearing capacity of the soil l o ading to settlement of the footings along the
outside edge of the balcony
Case No: 492366 Determination Page 11 of 11
Record Key points
The blockwork is not carrying any significant load except unintentionally as a
result of the foundation settlement
Damage is not ‘long term’ – damage observed bet ween November 201 5 –
March 2017 indicates damage has been ex pedited over a short period of time
Building performed reasonably well and was habitable until late 2015 – a
period of over 40 years