Home / Financial Firm (Unknown - Insurer) / Determination 491455

Determination 491455

Liability for allegedly defective roof repairs under lifetime guarantee

FirmFinancial Firm (Unknown - Insurer)
Decided2018-07-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded$550
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants said the FSP's roof repairs after a tree fall and storm claim were poor and still leak. AFCA found the FSP partly liable under the lifetime guarantee and ordered it to pay 50% of defective-work and eave repair costs plus $550 for a flashing, with the cost figures to be assessed.

The lifetime guarantee covers faulty workmanship in FSP-authorised repairs, but inherent low-pitch defects are excluded, so the FSP's liability was apportioned 50 per cent as fair in the circumstances.

Issues

Subjects and remedies

home or building damagepay compensationreassess claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 491455 Determination Page 1 of 7 Case number: 491455 26 June 2018 1 Overview 1.1 Dispute The applicants lodged claims for impact from a fallen tree, and storm damage in June 2016 and March 2017 respectively, against their home building and contents policy with the financial service provider (FSP). The FSP accepted both claims, however a dispute remains about the roof repairs under the first claim. The applicants say the roof was not repaired satisfactorily and continues to leak as a result. The FSP maintains all claim related damage to the roof has been appropriately repaired. It says available evidence shows any outstanding issues with the roof are not claim related, but due to installation issues and wear and tear. The case analyst provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the FSP. As the applicants did not accept the recommendation, the dispute has been referred to me for determination. 1.2 Issues and key findings Is the FSP liable pursuant to the lifetime guarantee? As the available material shows the damage was caused both by faulty workmanship and installation issues, it is fair in the circumstances the FSP pay 50% of the claim as set out in this determination. 1.3 Determination This determination is partly in favour of the applicants. Should the applicants accept this determination, then the dispute is to be settled in accordance with the mechanism set out in the paragraph headed “it is fair in the circumstances th e FSP pay 50% of stated costs.” Otherwise, the FSP is not required to take any further action in relation to the claim or the dispute. Case No: 491455 Determination Page 2 of 7 2 Reasons for decision I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have considered all the material submitted by the parties, both before and after the recommendation. I am satisfied the documentation I have relied on has been provided to both parties. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. No new material provided after the recommendation No further submissions or new materials were provided by the parties after the recommendation was rejected. 2.1 Is the FSP liable pursuant to the lifetime guarantee? Repairs to the roof were authorised by the FSP The applicants say the roof was not repaired properly and as a result their home leaks. The roof was repaired by the FSP’s builder. The FSP’s policy provides a lifetime guarantee on its builders’ repairs. This means the FSP will pay the cost to fix any faulty workmanship resulting from repairs authorised by the FSP. It is not in dispute the repairs to the roof were authorised by the FSP. However, the FSP’s policy also says the FSP is not obliged to pay if the repairs to the home fail because of wear, tear and gradual deterioration or if any one of the general exclusions (such as defective workmanship) in the policy apply. Numerous experts have inspected the roof Because of the complaints made by the applicants about the poor workmanship and the resultant leaking, the roof has been inspected on a number of occasions by the FSP’s builder (and his roofer) and by an assessor appointed by the FSP (AL) and a building consultant appointed by the FSP (GE). While the FSP’s builder accepted some of its building work required rectification, the builder did not accept responsibility for the ongoing leak to the roof along the rear patio. The roofer said his work was watertight. FSP’s assessor says the leaks occurred because of poor workmanship The FSP’s assessor inspected and photographed the property on 17 M ay 2017. The applicants told the assessor the roof had never leaked in this area prior to the roof repairs. After inspection and testing, the assessor concluded the leaks occurred because of poor installation and finishing works in the areas of the two leaks. Case No: 491455 Determination Page 3 of 7 The assessor’s detailed house plan and roof plan show the two areas where the leaks are and the water damaged eaves (or soffit). The assessor provided annotated photographs to demonstrate his contentions. Because of the difference of opinion between the FSP’s builder and FSP’s assessor, the FSP appointed another builder (GE) to provide “an impartial assessment.” FSP’s builder says leaks caused by poor installation GE inspected the insured property on 13 and 18 September 2017 with the builder and the male applicant. GE carried out a water test to the existing old lower section of the patio roof over the eaves area and water dripped from the ceiling lining. He says when he tested the new roof sheets water did not enter the eaves area. GE inspected the eaves which are made of a straw product. He said the eaves and the area in concern had been repaired on at least one occasion. He said the lower level roof had black bitumen tar product applied at some point to stop water ingress. GE relied on satellite imagery which shows the roof had been painted prior to the purchase of the property. GE asserts this would have covered up the rusting of the roof and repairs in the area of concern. In his second report, GE provides a description of the area where the roo f is leaking. He noted:  areas of water damage along the eave line  the area in the corner of the eave was repaired on a number of occasions  a flat single section transition flashing had been installed under the main roof extending onto the patio roof sheet  the flashing was original and not removed when the roof sheeting was replaced  both roof areas have low pitch and therefore the transition flashing has no way of turning up under the roof sheets  the roof sheet was installed at pitch of 1° or less which is less than the required roof slope of 2 to 4°. GE concluded because of the low pitch of both roofs no flashing will stop water ingress and the only method of preventing water ingress is to apply flexible sealant which GE said was evident from past repairs. GE said relying on flexible sealant to keep the area watertight is not good building practice or a long -term solution. GE was not critical of the FSP’s builder’s repairs. He did not consider the entire roof should have been replaced. He said the repairs had not contributed to the leak. Rather, he said the leaks are because of poor installation and the use of inappropriate material when the patio was installed. No expert report provided by the applicants The applicants continue to assert before the roof was repaired, the roof did not leak. However, after repairs, they say the part of the roof which was repaired leaks and continues to leak. However, the focus of both expert reports is in relation to a specific location discussed with the applicants at the time of the inspections. That is, in the Case No: 491455 Determination Page 4 of 7 area where the main roof meets the patio roof. The available material only addresses leaks in this area. The applicants say the FSP accepted the cheapest quote and the work done was inadequate. I accept the FSP accepted the cheapest quote. The FSP says this is because the other quote was for the repair of the whole roof. Having considered the photographs of the impact damage to the roof, the make safe repairs and the scope of works, I accept it was not necessary to repair the whole roof. After the recommendation, the applicants indicated they were awaiting a report. While the applicants have provided photographs in support of their assertion the work on the roof was done poorly, no independent expert evidence has been provided by the applicants before or after the recommendation. Both reports from the FSP’s assessor and builder have merit The applicants have the onus of proof to establish their contention the roof was repaired poorly and therefore it now leaks in the subject area. Although they have provided no expert report, I find the report from the FSP’s assessor persuasive particularly in view of the photographs which show water was leaking onto the deck from the hose test. The photographs also show the old roof has not been resealed after the new roof sheets were installed and the new sealing has cracked and failed where the new flashing and new roof sheets meet. However, I am also persuaded there are further issues with the low pitch of the both roof areas as described by GE which caused leaks and resultant damage. I accept the issues with the roofs described by GE would be excluded under the policy exclusion which excludes loss or damage to the home caused by an inherent defect. It is fair in the circumstances the FSP pay 50% of stated costs Taking all matters into account, and the ambivalence of the expert material, I am satisfied it is fair in the circumstances the FSP pay 50% of the cost to repair the defective work identified by its assessor being the costs to reseal the old roof where the new roof sheets were installed and 50% of the repair costs of the new sealing where the new flashing and new roof sheets meet. The experts agree there is water damage along the eave line. In the circumstances I am also satisfied it is fair the FSP pay to the applicants 50% of the costs to repair the water damaged eaves where the main roof meets the patio roof. GE said the best way to stop water ingress to the eave patio area would be to install a flashing over the roof area at an estimated cost of $550. He also said the applicants would need to monitor this and renew the sealant every couple of years. This cost was not estimated. I am further satisfied it is fair the FSP pay to the applicants $550 to install a flashing over the roof area as described by GE. This payment is to take into account the cost to renew the sealant every couple of years. Should the applicants accept this determination, then within 14 days of acceptance, the FSP is to assess the costs to rectify the defective work identified by its assessor Case No: 491455 Determination Page 5 of 7 and the cost to repair the water damaged eaves where the main roof meets the patio roof and thereafter, within a further seven days, pay to the applicants 50% of the assessed repair costs. At that time, the FSP is also to pay to the applicants $550. FSP already paid $1,000 ex gratia to the applicants The applicants complained about the FSP’s management of the claim. As the FSP has offered and the applicants have accepted a $1,000 ex gratia payment, I do not propose to address this issue in this determination. Case No: 491455 Determination Page 6 of 7 3 Supporting information 3.1 FOS Approach It is an accepted principle of general insurance law that an insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. 3.2 Relevant policy extracts The relevant policy extracts are referred to in correspondence between the parties and in the FSP’s dispute response/conciliation brief. Both documents have been exchanged with the applicants. General exclusions What we don’t cover These general exclusions apply to all of the cover we provide under your policy. We don’t cover you under your policy for loss or damage to your home… which is caused by or arises in connection with any of the following items, events or circumstances. Defective or faulty workmanship: Any inherent or built-in defect or defective or faulty workmanship, design or manufacture. 3.3 Relevant expert reports Report Key points Make safe report 27 June 2016  A tarp was placed over the damaged section of roofing.  Photographs of impact dama ge to roof. FSP’s expert ( CP ) Roof report 17 May 2017  Reported on and photographed roofing and leaking in support of report and provided mud map.  Water entry points/locations and reason for water entry ...  Sealant failed at three points including: - leak 1: where new roof meets the old roof not resealed after new roof sheets installed - leak 2: where the new flashing and new roof sheet meets new sealant has been used to cover lapping of flashing, this sealant has failed.  Because of leaks 1 and 2, the deck soffit has been water damaged.  Leaks that have occurred due to poor installation and finis hing of works in the relevant areas.  None of any items that require removal and replacement solar panels et cetera to facilitate repairs. FSP’s expert ( CR ) Building consultant email  “ carried out a water test to the existing old lower section of the veranda roof over the eaves area and water was found to be dripping from the ceiling lining ” Case No: 491455 Determination Page 7 of 7 13 September 2017  “ testing of the new roof sheets found no sign of water entry to the eaves area ”  evidence of at least one prior repair to eaves  evidence of previous repairs to area in concern being “ junction of the lower level veranda roof and the newly installed section of roof sheeting to the main roof . The lower level roof has h ad black [ bitumen ] tar product applied at some point to stop wat er ingress. ”  satellite imagery (attached) shows previous repairs to the area as far back as 2009, roof completely paint ed between November 2011 and May 2012 to cover rusting  “In summary the re placement of the roof sheets is not contributing to the leak and damage to the eaves that is currently observed. The damage is due to long term water ingress due to the poor design of the Veranda roof where it meets the main roof. The eaves are a [S…] stra w product and continue through to the Dining room ceiling ”. FSP’s expert ( CR ) Building consultant report 18 October 2017 Roof leak  “ Replacing the roof sheets has not cont ributed to the leak that currently exists. The leak is the result of poor installation and the use of inappropriate material when the patio was installed  installation relies on flexible sealant to keep the premise water tight which is not good building practice or a long term solution. Any attempt to rectify the problem will nee d to rely on flexible sealant and will not be able to sufficiently warrant the repair.  It is my opinion that the best way to stop water ingress to the eave / Patio area would be to install a flashing over the roof area for the length of the patio stepping down onto the lower patio roof. This flashing will need to be sealed at the upper level roof using flexible sealant (See photo). The Insured will need to monitor this and renew the sealant every couple of years as it wears and deteriorates ” .  No requiremen t for the entire roof to have been replac ed. 3.4 Other relevant material considered and relied on  Parties’ submissions, emails and photographs and all attachments to all submissions.  Correspondence between the parties.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.