Determination 490211

Ceiling collapse claim denied; storm not established as cause

FirmFinancial Firm (Unknown - Insurer)
Decided2018-06-20
ProductGeneral Insurance · Landlord
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed under his landlord policy for a bedroom ceiling collapse attributed to strong winds, and the FSP denied it as caused by inadequate fixings. AFCA decided the applicant had not established a storm as the cause, so the FSP could deny the claim and the loss of rent claim.

The applicant bore the onus of proving a prima facie claim under the storm insured event and did not establish, on the balance of probabilities, that a storm caused the collapse.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 490211 Determination Page 1 of 4 Case number: 490211 19 June 2018 1 Overview 1.1 Dispute The applicant lodged a claim under a landlord insurance policy, held with the financial services provider (FSP), following the collapse of a bedroom ceiling, claimed as the result of strong winds. The FSP has denied the claim on the basis the damage to the property was excluded under the terms and conditions of the policy. The case analyst issued a recommendation on the issues in dispute. The applicant did not accept the recommendation so the dispute has been referred for determination. A copy of the recommendation is attached to this determination. 1.2 Issues and key findings Is the FSP entitled to decline the claim? The applicant has not established the damage to the ceiling was caused by an insured event under the policy. The FSP is entitled to deny liability with respect to the claim. Is the applicant entitled to a claim for loss of rent? The applicant has not successfully established the damage was caused by an insured event and is therefore not entitled to a claim for loss of rent. 1.3 Determination The determination is in favour of the FSP. The FSP is not required to make any further payments to the applicant. Case No: 490211 Determination Page 2 of 4 2 Reasons for determination I have decided this case on the basis of what I consider fair in all the circumstances, having regard to relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all material submitted by the parties, both before and after the recommendation. I am satisfied that the documentation I have relied on has been provided to both parties. I am satisfied the case analyst‟s recommendation contains an accurate summary of the dispute, the issues to be determined, any applicable paragraphs of the Terms of Reference and any relevant law. 2.1 Was the FSP entitled to deny the claim? Onus is on the applicant to establish an entitlement to cover under the policy There is an onus on an insured to establish on the balance of probabilities, that the applicant has suffered a loss caused by an event covered by the policy. This is called a prima facie claim. If the insured is able to establish a prima facie claim under the policy, the insured is then required to show, on the balance of probabilities, the loss falls within an exclusion clause of the policy or is otherwise not covered. In this dispute, the applicant had lodged a claim for damage to a bedroom ceiling as a result of storm damage, caused by strong winds. The applicant‟s policy is a defined events policy, and included in the events is „storm‟. To establish a prima facie claim, the applicant must demonstrate, on the balance of probabilities, the damage was caused by a storm. Expert opinions There was no dispute that the applicant suffered a loss with the collapse of the ceiling. The applicant provided a report by BS, dated 19 September 2017, who replaced the ceiling at the insured property. BS certified that:  „ The ceilings in 4 rooms were replaced in a whole or part ( bedroom, living room, 2 small hallways .‟  ‘ All ceilings appeared to have failed recently and simultaneously. There were no signs of any progressive or serial failure of the attachments. I did note some localized dampness in the bathroom area of the hallway (near a ceiling fan), not affecting structural strength ’ .  ‘ The ceiling attachments in all areas appeared adequate, and in good condition ’ . The applicant also provided routine real estate inspection reports from 2016. The applicant refers to the report nine months prior to the storm which did identify cracks in the premises but the applicant believes they were „ quite small and narrow ‟ and in relation to corners cracking from the ceiling „so minor that, even on the original colour photograph...I am struggling to see anything wrong at all.‟ Case No: 490211 Determination Page 3 of 4 The FSP obtained a report from a builder HWL, who visited the premises on 29 July 2017 and concluded: In our opinion the damages to the property have occurred due to insufficient fixings to the ceiling and possibly a combination of movement within the property, which has created stress on the ceiling and subsequently causing it to fail. FMG who was an engineer was also engaged by the FSP and prepared a report dated 24 August 2017. He concluded: […] the space between the mechanical fixing locations and adhesive fixing is incorrect and that such increased load on the individual ceiling fixings has caused an progressive failure of the ceiling until catastrophic collapse. The applicant has not established a prima facie claim Substantial damage occurred to the ceiling however, the applicant has not provided information that disputes the reports provided by the FSP. I am unable to determine, on balance, that the loss occurred as a result of the specific storm event. I do note that there was substantial wind event around the date of the roof collapse. This is noted in FMG‟s report. However, the applicant has not provided any information that, in my view, refutes the findings of FMG and HWL. The report provided by BS does note that the ceiling attachments appear to be adequate and in good condition. However, I am persuaded by HWL who noted fixings were 500mm to 600mm apart and they believe they should have been 250mm to 300mm apart. They also noted that there were movement cracks in the surrounding rooms which may have contributed to the ceiling falling. FMG noted the space in between the mechanical fixings and adhesives were incorrect at every second joist. He states this arrangement of fixings significantly altered the distribution of force which resulted in the progressive failure of ceiling plaster boards. The applicant has not provided information that would dispute these findings. The report HWL should not be excluded The applicant states that the original decision was reached without reference to the HWL report and denies that the FSP is entitled to rely on the HWL report in any subsequent proceedings, including those involving FOS. I do not accept that I am not able to rely upon the HWL report of 29 July 2016. FOS takes into account all information that is provided by applicant and FSP to make a determination on the balance of probabilities. The report has been exchanged with the applicant and the applicant has had the opportunity to address all ma tters raised. The FSP is entitled to deny the claim I have considered any insured events which may have resulted in the damage to the roof. I am unable to find any, on balance, any insured event that led to the damage.I consider in these circumstances the FSP is entitled to deny the applicants claim. Case No: 490211 Determination Page 4 of 4 The applicant is not entitled to loss of rent The applicant has made a claim for loss of rent. This claim can only be considered if the applicant‟s claim for damage has been accepted. The claim has not been accepted and the FSP is entitled to decline the loss of rental claim. Recommendation Case No: 490211 Recommendation Page 1 of 5 Case number: 490211 28 November 2017 3 Overview 3.1 Dispute The applicant lodged a claim under his landlord insurance policy for storm damage following strong winds, which caused the collapse of the bedroom ceiling. The financial services provider (FSP) denied the claim because it says the damage caused to the property was excluded under the terms and conditions of the policy. The applicant disagrees with the FSP‟s decision and seeks that it accept the claim in full and also compensate him for loss of rental income. 3.2 Issues and key findings Was the FSP entitled to deny the claim? Based on the available information the applicant has not been successful in establishing, on the balance of probabilities, the damage was caused by an insured event under the policy. In the circumstances, the FSP is entitled to deny the claim. It follows the applicant is not entitled to loss of rental income. 3.3 Recommendation The recommendation is in favour of the FSP. The FSP is entitled to deny the claim. Case No: 490211 Recommendation Page 2 of 5 4 Reasons for recommendation Was the FSP entitled to deny the claim? Applicant has initial onus to establish claim In order to claim under a policy, the initial onus is on the insured to show the damage was caused by an event covered under the policy. This is known as a prima facie claim. If the insured can establish a prima facie claim, the onus then shifts to the FSP to show the damage claimed is excluded under the policy or that it is otherwise entitled to deny the claim. The applicant‟s policy provides cover for loss or damage caused by defined events, subject to the various conditions and exclusions set out in the policy. One event is „storm‟. Therefore, for the applicant to establish a prima facie claim, he must demonstrate, on the balance of probabilities, the damage was caused by the storm. Expert evidence relating to property and content damage The applicant says on or about 12 July 2016 his rental property sustained damage due to a storm event which caused the bedroom ceiling to collapse. In order to support his position the applicant has provided a letter from the builder, BS, who repaired the damage in October 2016. In its letter, dated 19 September 2017, BS stated he replaced the ceilings in four rooms at the property and observed the following:  all ceilings appeared to have failed recently and simultaneously  no signs of progressive or serial failure of the attachments  localised dampness in the bedroom area of the hallway, not affecting structural strength  ceiling attachments appeared adequate and in good condition. The applicant also relied upon local news articles and real estate agent inspection reports from 2015 and 2016 which were carried out prior to the loss. The FSP engaged a builder, HWL, to inspect and comment on the damage at the time of the loss. In its report HWL concluded the following: In our opinion the damages to the property have occurred due to insufficient fixings to the ceiling and possibly a combination of movement within the property, which has created stress on the ceiling and subsequently causing it to fail. The FSP further engaged an engineer, FMG, to comment on the damage. FMG prepared a report on the cause of the damage. In its report FMG concluded the following:  weather data obtained from the Bureau of Meteorology indicated that there was not a significant wind event on 14 July 2016 (35km/hr). Wind speeds of 93km/hr were recorded on 12 July 2016.  Wind speeds of this magnitude should not have caused an internal ceiling collapse and would be common with an N2 category wind storm. Case No: 490211 Recommendation Page 3 of 5  Damage to the unit was caused by incorrect fixing/spacing. FMG went on to say: […] the space between the mechanical fixing locations and adhesive fixing is incorrect and that such increased load on the individual ceiling fixings has caused an progressive failure of the ceiling until catastrophic collapse. In reviewing the expert reports provided by the FSP and other available information provided by the parties, there is no dispute the applicant‟s property sustained significant damage. I acknowledge the applicant says the damage to the ceiling was caused by a localised storm event in the period the loss occurred. However, there is not enough information to establish, on balance, that one single storm event was the sole and only cause of the ceiling collapse. Whilst the applicant provided an expert opinion from BS who repaired the ceiling, the letter is very brief and does not refute or challenge the FSP‟s report as to the exact cause of the damage. Further, the applicant‟s routine inspection report of the property from 2015, noted large cracks developing in the passage wall and cornice cracking from the ceiling. This was supported by photographs which show visible cracking at the property. In reviewing this information it is evident the ceiling at the property had prior cracking. In the absence of any further information commenting on the cause of the damage at the time of the loss, I accept the findings of FMG and HWL. Whilst the applicant has provided news articles, and a letter from his builder, the material was not supported with reasons or logical conclusions which linked the loss to a specific storm event. Applicant has not established prima facie claim I have also considered whether any other insured event would apply in this dispute. Whilst the applicant supplied a letter from a builder who repaired the ceiling and news articles noting weather in the days surrounding the loss; there has been no other information provided which establishes the exact cause and event which caused the ceiling to collapse. On the information provided, I cannot see any direct link that the damage was solely caused by a storm event. As such, the applicant has not established, on the balance of probabilities, the damage was caused by an insured event. I am of the view the policy cannot respond to an event which has not been established. In these circumstances, I consider the FSP was entitled to deny the claim. Applicant not entitled to loss of rental income The applicant has raised a claim for loss of rent due to damage sustained to his rental property. In reviewing the applicable policy terms and conditions it states the claim must be accepted before loss of rent can be considered. As I am satisfied that the FSP is entitled to decline the claim, I consider the FSP was entitled to decline the claim for loss of rental income. Case No: 490211 Recommendation Page 4 of 5 5 Supporting information 5.1 Policy Wording Storm We cover loss or damage by a storm […] Loss of rent following an insured event We cover When you have property cover If we accept your claim for loss or damage to your property due to an ins ured event during the period of insurance and we agree it cannot be lived in, we will pay the weekly rental amount for the reasonable amount of time we decide it should take to repair or build the property s o it can be lived in again. […] General Exclusions You are not covered under any section of this policy for damage, loss, cost or legal liability that is caused by, arises from or involves: Wear, tear, mould, gradual deterioration and other conditions Wear, tear, rust, fading, rising damp, mould, mildew, corrosion, rot, action of light, atmospheric or climatic conditions or gradual deterioration such as, but not limited to:  Tiles and their adhesive or grouting breaking down  Weathering of roof tiles or roof ridge capping  Gradual weathering and breakdown or bricks, mortar or concrete. Further examples: carpet worn from your people working on it. Gutters rusting after exposure to the elements. 5.2 Expert Reports Record Key points APP’s expert (BS) Builder‟s Le tter 19 - 09 - 2017  ceiling attachments appeared adequat e and in good condition  all ceilings appeared to have failed recently and simultaneously  no signs of progressive or serial failure of the attachments  localised dampness in the bedroom area of the hallway, not affecting structural strength. FSP’s expert (HWL) Builder Report 29 - 07 - 2016  Upon close inspection of the above ceiling joints we found the fixings were approximat ely 500 to 600 mm apart, which in our opinion, is insufficient. We believe fixin gs should be installed approximately 250 to 300 mm apart.  Furthermore, we found evidence of movement cracks to the Case No: 490211 Recommendation Page 5 of 5 property in surrounding rooms. Which we believe may have contribut ed to the ceiling falling.  An inspection of the ceiling space… found no wat er ingress…. Furthermore an inspection of the removed ceiling lining was undertaken and we found no water stains to the ceiling lining which again suggests water entry through the roof has not caused the section of the ceiling to fail. Applicant’s expert (FMG) Engineering Investigation Report 24 - 08 - 2016  Building is approximately 23 years old.  There is evidence of building movement in the living room and north western bedroom. However, the degree would add little to no stresses to the ceiling fixings.  FMG n oted no sarking material was laid under the roof tiles.  A detailed ins pection of exposed timber ceiling joists found that the adhesive and mechanical fixings are spaced incorrectly in relation to one another on every second joist.  The Gyprock installation manual states that “to reduc e possibility of fasteners popping, permanent fasteners should not be closer than 200 mm from the edge of adhesive daubs”. There are locations were permanent/mechanical fixings are located through adhesive daubs.  Weather data obtained from the Bureau of Met eorology indicated that there was not a significant wind event on 14 July 2016 - 35km/hr. Wind speeds of 93km/hr were recorded on 12 July 2016. Wind speeds of this magnit ude should not have caused an internal ceiling collapse and would be common in an N2 category wind zone.  If the event had caused the damage in the area of concern, FMG would typically expect the occurrence of the following: 1. ….wind speeds in excess of 118km/hr 2. The adhesive and mechanical fixing to be appropriate ly spaced in accordance with Gyrock installation manual.  Spacing between the mechanical fixing and adhesive was incorrect at every second joist. This arrangement of fixings significantly altered the distribution of forces which resulted in a progressive fa ilure of the ceiling plaster boards. 5.3 Other relevant material relied upon  Certificate of Insurance, 6 July 2016 to 6 July 2017  Product disclosure statement.  Parties‟ submissions.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.