Home / Financial Firm (Unknown - Insurer) / Determination 488815

Determination 488815

Rumpus room ceiling collapse claim declined; applicant alleged faulty 2008 storm repairs by FSP's authorised repairers

FirmFinancial Firm (Unknown - Insurer)
Decided2018-07-20
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for a ceiling collapse eight years after storm repairs the FSP authorised, alleging the repairs were defective. AFCA found the applicant had not shown the repairs caused the damage or that an insured event did, and rejected the claim and the request for non-financial loss compensation.

The applicant bears the onus of establishing a prima facie claim under the policy, and on the balance of expert evidence the collapse was due to gradual deterioration from roof loading rather than insured events or defective repairs.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 488815 Determination Page 1 of 4 Case number: 488815 20 July 2018 1 Overview 1.1 Dispute The applicant holds a home and contents policy with the financial services provider (FSP). He lodged a claim against his policy, saying the collapse of his rumpus room ceiling was due to the poor workmanship of the FSP’s authorised repairers following a previous storm damage claim in 2008. The FSP assessed the damage and denied the claim. The FSP said the ceiling collapse was not a result of the 2008 repairs. Instead, the ceiling collapsed because of the load on the timber roof trusses over time. The applicant disputes this and has produced reports from an expert in support. The case analyst provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the FSP. A copy of the recommendation is attached to this determination. 1.2 Issues and key findings Were the findings of the recommendation correct? The findings contained in the recommendation were correct and are adopted in this determination. Further submissions provided after the recommendation have been considered. These submissions have not warranted a change in the outcome. Has the applicant established a valid claim? The applicant has not shown the FSP’s previous repairs caused the damage. Nor has he otherwise established a valid claim to which the policy responds. This means the FSP is entitled to deny the claim. Is the applicant entitled to compensation for non-financial loss? The applicant has not established an entitlement to compensation. 1.3 Determination This determination is in favour of the FSP. I agree with the case analyst ’s reasons for the recommendation and the recommended outcome. The FSP is not required to undertake any further action with respect to the claim. Case No: 488815 Determination Page 2 of 4 2 Reasons for determination 2.1 Were the findings in the recommendation correct? I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I ha ve taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied the documentation I have relied on has been provided to both parties. I am satisfied the case analyst ’s recommendation contains an accurate summary of the dispute, the issues to be determined, any applicable paragraphs of the Terms of Reference and any relevant law. 2.2 Has the applicant established a valid claim? Policy covers insured events subject to exclusions The applicant bears the onus of establishing a valid claim (also called a prima facie claim) to which the policy responds. The policy covers loss or damage from insured events. The applicant had previously lodged a claim against his policy in 2008 after a storm. On that occasion, rainwater had entered his home as a result of damage to the roof. The FSP authorised repairs, which included part of the rumpus room ceiling near the front entrance. The applicant says a far larger area of the rumpus room ceiling collapsed in December 2016 , as a result of the FSP’s previous repairs . The FSP is responsible for the quality of any repairs it carries out or authorises under the policy. However, it is for the applicant to show that those repairs were inadequate or otherwise caused the later damage. Alternatively, the applicant needs to show, on balance, the damage was caused by a specific insured event under the policy. Conflicting information provided by the parties’ experts The FSP’s engineer ( F) concluded in a report dated 5 January 2017 that the later damage was not from inadequate repairs to the ceiling in 2008. F said it was the result of excessive loading on the roof framing, causing long-term deflections in the timber trusses. This placed additional stresses on the ceiling lining fixings and resulted in the ceiling failure. The applicant obtained a report dated 8 May 2017 from an architect (IN), disagreeing with F. IN said the applicant had reported a ‘significant sag in the ceiling’ starti ng in the area of the previous repair. IN said the plasterboard would have become heavier the more it sagged and would have ultimately led to the collapse of the other plasterboard within the room. Case No: 488815 Determination Page 3 of 4 F provided a further report dated 15 June 2017 in response to IN. F noted the repairs had been carried out eight years before the collapse and it was not possible to determine which section of the ceiling had initially become detached. F also pointed out that IN was not an engineer, and questioned IN’s explanatio n of the effect of the loading of the attic and solar panels on the roof trusses. F explained that s tructural engineering principles suggest the solar panels on the applicant’s house would impact the ceiling over the rumpus room; and the roof trusses would have been designed to carry only the original weight of the roof finishes and the plasterboard ceilings of the house. F said timber had the propensity to ‘creep’ under long term static loads , and that ‘creep’ is the time -dependent deformation of loaded members undergoing elastic deformation. F indicated the long term deflection of the roof trusses caused the gradual detachment and sudden collapse of the plasterboard linings only from the trusses subject to additional load from the solar panels. The applicant then also obtained a further report from IN in February 2018. IN said the plasterboard patch repair in 2008 had been fixed to the underside of roof trusses using screws, and there was no evidence of the use of glue. IN said the screw-only installation does not comply with the plasterboard manufacturer’s guidelines, and concluded the installation of the plasterboard eight years previously was substandard because of incorrect nail installation and lack of back blocking. On balance, F SP’s experts’ findings are more compelling IN has relied, at least in part, on the applicant’s comments in reaching their conclusions. However, there is no evidence to confirm the location of the initial ceiling sag. IN has also referred to the manufactur er’s manual and concluded a failure to follow the guidelines means the repairs must have been defective (because of the use of screws only, and not adhesive as well) On the available evidence, however, I am not satisfied the installation of that particular part of the ceiling was defective, or that a clear link has been shown between that installation and the overall damage which took eight years to occur. F, on the other hand, persuasively explained how the loading of solar panels and the attic operated over that time frame to ultimately cause the ceiling collapse. I consider F is appropriately qualified to comment on the structural and engineering issues affecting the house, and am satisfied F’s rep orts compellingly explained the effective cause of the collapsed ceiling: F ruled out the 2008 repairs, and concluded the cause was pressure exerted over time by issues including the solar panels and attic. So, I accept the effective cause of the ceiling collapse eight years after the 2008 repairs was more likely than not the additional cumulative loading on the roof trusses from the attic and solar panels (which then placed further stress on the ceiling lining fixings), as explained by F. I am therefore not persuaded the FSP should reasonably be responsible for the damage. That is because the evidence does not establish the FSP’s previous repairs caused the later ceiling damage; nor has that been shown to be the result of any other insured event. Instead, it is reasonable to regard it as being the result of gradual deterioration. Case No: 488815 Determination Page 4 of 4 2.3 Is the applicant entitled to compensation for non-financial loss? The applicant has not proved an entitlement to compensation Our Terms of Reference allow FOS to require an FSP to pay an applicant compensation for non-financial loss in certain situations. However, this will only occur where the applicant has suffered an unusual degree or extent of physical inconvenience, time taken to resolve the situation or interference with their expectation of enjoyment or peace of mind. Compensation is not warranted where an applicant suffers inconvenience that is reasonably to be expected as a normal part of a claims process. I acknowledge that the claims process can be stressful, upsetting and time- consuming. I also appreciate that the applicant was experiencing health issues over that time. However I am not satisfied that the FSP’s handling of the claim has been such that compensation is warranted in this case. Recommendation Case No: 488815 Recommendation Page 1 of 6 Case number: 488815 15 January 2018 3 Overview 3.1 Dispute In 2008, the applicant lodged a home claim with the financial service provider (FSP) for storm damage his property, and repairs were completed. However in 2016, the applicant lodged a claim as his ceiling collapsed. The applicant says the damage was caused by the FSP not completing the works correctly in 2008, and provided an expert report to support his position. The FSP assessed the claim, but denied liability because it says the claimed damage was not related to storm damage repairs completed by the FSP in 2008. It says the damage does not relate to a single insured event. To resolve this dispute, the applicant is seeking compensation and for the claim to be accepted. 3.2 Issues and key findings Is the FSP entitled to deny the claim? The FSP was entitled to decline the claim because the damage has not arisen as a result of an insured event, or from any subsequent works undertaken by the FSP in a prior claim. Rather, it arose from events which are specifically excluded from cover. Is the applicant entitled to compensation? Whilst I acknowledge the claims process may have been stressful for the applicant, there is no entitlement to non-financial loss. 3.3 Recommendation This recommendation is in favour of the FSP. The FSP is not required to take any further action. Case No: 488815 Recommendation Page 2 of 6 4 Reasons for recommendation 4.1 Was the FSP entitled to deny the claim? Applicant has the onus to establish a claim It is established insurance law the applicant carries the initial onus to show that the terms and conditions of the relevant insurance policy covers the loss. This is known as a valid or prima facie claim. Once the applicant establishes a prima facie claim, the onus then shifts to the FSP to demonstrate the loss is not covered, either by way of one of the policy exclusions or on some other basis. The applicant’s policy is an insured events policy. Therefore, the policy only responds where one or more of the listed events causes the damage, subject to any exclusions. The policy provides cover for storm. The FSP does not dispute the policy provides cover for loss or damage to buildings as the result of a storm event. However, the FSP says the damage was not as a result of any listed event. Rather, the FSP says the damage was caused by gradual deterioration and wear and tear. In circumstances where an applicant calls upon a policy benefit, such as a repair guarantee, the onus is the same as if they were establishing a claim. That is, the applicant must demonstrate, on the balance of probabilities, the current issues at the property resulted from either the initial event, or any subsequent repairs. Different opinions on the cause of damage The FSP appointed an engineer (F) to inspect the applicant’s home and identify if the damage is related to repairs completed in 2008, or if it’s another cause. F concluded damage is unrelated to repairs in 2008, and says damage is caused by the ceiling collapsing due to excessive loading on the roof framing. F states the roof trusses were not designed to support the additional cumulative loads added by the fitting of the attic framing, and installation of the solar panels. The applicant claims the ceiling has collapsed due to faulty workmanship from a previous repair done by the FSP in 2008. The applicant stated significant sagging occurred where repairs were initially competed. To support his position, the applicant provided correspondence outlining his view on why the exclusion does not apply, and also engaged an engineer (IN) to respond to F and determine the cause of damage. IN says the cause of the ceiling collapse was due to an incorrectly or poor ly installed plaster patch that was part of the repairs commissioned by the FSP in 2008. Extracts of F’s and IN’s findings are included in section 3.2 below. The FSP however says this is insufficient, as the Australian standards for installation during 2008 stated that installation by screws only is one of the accepted methods of Case No: 488815 Recommendation Page 3 of 6 installation. It says the use of screws instead of screws and glue as adhesion is a difference in finishing requirement rather than a safety requirement. No information to suggest faulty workmanship The applicant disagrees with F’s findings and maintains the damage was caused by 3 screws holding up 13mm plasterboard with no glue. IN’s report addresses faulty workmanship and states:  screw fixing 13mm thick ceiling plaster without application of glue is prone to failure because of the inherent brittleness and weight of the plasterboard  the plaster patch joint line was placed between roof trusses with a timber batten installed to back block this joint back blocking is performed by gluing plaster along the joint line. Timber would be too heavy in particular along a joint line potentially resulting in delamination of the plaster joint  installing plaster patch with the long joint placed in between roof trusses is not correct installation procedure  the plaster patch installation therefore deemed to be substandard and inadequate, not complying with standard industry standards for plasterboard installation. However, the FSP argues the above information is insufficient to show the FSP is liable for the ceiling collapse in 2017. The FSP has obtained information showing adhesive practices recognised in the industry for plasterboard installation. The information shows that repairs done by installation by screws on is an acceptable method. Accordingly, in the absence of any information, it appears, on the balance of probabilities, the FSP adopted or complied with the correct standards. As such, I am not satisfied the applicant has established an entitlement under any repair guarantee. Applicant has not established a prima facie claim The applicant needs to establish on the balance of probabilities, that his property was damaged by an event for which the policy provides cover during the period of insurance. The applicant’s policy is a defined events policy with no cover for accidental damage to his property. On the information provided, I am not satisfied the applicant has established a prima facie claim for the damage to his property. In light of the above, I accept the FSP was entitled to decline t he applicant’s claim. 4.2 Is the applicant entitled to compensation? FOS expects the applicant to bear some stress and inconvenience Under paragraph 9.3(a) of the Terms of Reference, FOS may award an amount of compensation (capped at $3,000) for non-financial loss where an applicant has suffered an unusual degree or extent of physical inconvenience, time taken to Case No: 488815 Recommendation Page 4 of 6 resolve the situation or interference with their expectation of enjoyment or peace of mind. However, FOS expects an applicant to be moderately robust and bear the usual stress and inconvenience associated with an insurance claim. Applicant is not entitled to compensation The applicant is seeking compensation due to the inconvenience and stress he has experienced. The applicant says the FSP’s actions caused him inconvenience. I accept stress and inconvenience can be suffered as a consequence of lodging a claim. As information suggests damage did not occur as a result of an insured event or from any repairs under the previous claim, the FSP is not liable for any compensation. Case No: 488815 Recommendation Page 5 of 6 5 Supporting information 5.1 Other matters considered but which did not change the outcome The FSP has also raised other concerns in relation to the collapse of the ceiling. The FSP states the cause of the collapse was due to additional loads added by the attic framing, and installation of the solar panels causing excessive loading on the roof framing. As the applicant has not established faulty workmanship has been conducted, there is no need to consider in detail the other issues raised as it does not change the outcome. 5.2 Key Reports Record Key points FSP’s expert ( F ) Report 5 - 1 - 17 ‘ It is F’s opinion that the damage to the house was not caused by inadequate repairs to the ceiling from a previous claim in 2008.’ ‘It is F’s opinion that the damage to the subject house has been caused by excessive loading on the roof framing, causing undesirable long - term deflections in the timber tr usses, thereby placing additional stresses on the ceiling lining fixings, contributing to the ceiling failure.’ ‘It is F’s opinion that the local repair of the ceiling from a previous claim did not cause, nor contribute to, the damage to the subject house because the maximum ceiling damage was observed at the east side of the Rumpus room, remote from the area of ceiling locally repaired over the Front Entry.’ ‘The (collapsed) ceiling lining in the house was installed with screw fixings in combination with p laster adhesive which is the correct method of construction for plasterboard lining. Furthermore, F obs erved remnants of the ceiling lining at the screw fixings and at the plaster adhesive locations [8], indicating the adhesive was properly attached to the ceiling lining. The ceiling has been in place for approximately 30 years (except for the potion of ceiling repaired in 2008) and there is no indication of moisture ingress as discussed in Paragraph 4.4. Furthermore, the owner noted that the ceiling lining in the house was dry with no signs of deterioration and/or moisture/wat er stains prior to its collapse. ’ Applicant’s expert ( IN ) Report 8 - 5 - 17 ‘The incorrectly / poorly installed plaster patch being part of ceiling repairs performed in 2008 following wat er damage inside this building because of water entry during a storm event that dislodged a number of roof tiles located within this area of the building, is deemed to be area where the plasterboard collaps e started to occur. It is within this area along t he plasterboard patch installed in 2008 that the property owner instructed the author of this report that he noticed significant Case No: 488815 Recommendation Page 6 of 6 sag in the ceiling. The more the plasterboard sagged, the heavier the plasterboard would have become, with the sagging plasterb oard eventually becoming too heavy as the plasterboard continued to sag along the plaster patch splice point eventually letting go pulling down the other plasterboard within this room as the plasterboard delaminated from the underside of the bottom chord o f the roof trusses.’ ‘The property owner does not use the attic space. Considering that the attic space is located partially over the south side of the house, on the side of the Rumpus room, & partially over the North side of the house, with no signs of de flections, sag, damage, or deterioration to any of the ceilings along the north side of the building or ceilings adjacent the Rumpus room, the attic space is not considered to be a factor in the most recent ceiling collapse within the Rumpus room.’ ‘Consid ering that the solar panels are actually installed over the northeast side of the house which is away from the Rumpus room, loading of the roof trusses would not have impacted the ceiling over the Rumpus room, particularly considering that the plasterboard ceilings located along the north side of the house, in particular directly under the Solar panels are in good order with no signs of; deflections, sag, damage, or deterioration. The solar panel installation is therefore not considered to be a factor in th e most recent ceiling collapse within the Rumpus room. ’

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.