Home / Financial Firm (Unknown - Insurer) / Determination 487691
Determination 487691
Water leak and ground movement damage claim declined
Summary
Applicants claimed under their home building policy for cracking damage they attributed to leaking pipes. AFCA accepted that ground movement was the dominant cause and found the FSP entitled to deny the claim.
The proximate cause of the damage was seasonal ground movement, which is not a listed insured event, and the damage likely manifested before the policy commenced.
Issues
- Claim denial primary · not upheld“The FSP is entitled to deny the applicants' claim on the basis that the damage was due to seasonal ground movement.”
- Product terms interpretation secondary · not upheld“Even if the damage was caused by leaking pipes, there is no listed event which covers loss or damage caused by ground movement.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 487691 Determination Page 1 of 4
Case number: 487691 15 June 2018
1 Overview
1.1 Dispute
The applicants lodged a claim with the financial services provider (FSP) for damage
to a number of sections of their property caused by water leaking from numerous
pipes.
The FSP declined the claim on the basis that the damage arose from seasonal and
moisture changes, the drying effect of adjacent trees and that the damage claimed
occurred before the policy commenced. The applicants appointed their own engineer
who considered the water leaks were likely the contributing factor and the result in
damage to the dwelling.
The case manager issued a recommendation on the issues in dispute. The applicant
did not accept the recommendation so the dispute has been referred for
determination. A copy of the recommendation is attached to this determination.
1.2 Issues and key findings
Is the FSP entitled to decline the claim?
The FSP is entitled to deny the claim on the basis that the damage was due to
seasonal ground movement.
1.3 Determination
The determination is in favour of the FSP.
The FSP is entitled to deny the applicants claim.
Case No: 487691 Determination Page 2 of 4
2 Reasons for determination
I have decided this case on the basis of what I consider fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions. I have taken into account all material submitted by the
parties both before and after the recommendation. I am satisfied the documentation I
have relied on has been provided to both parties.
I am satisfied the case manager ’s recommendation contains an accurate summary of
the dispute, the issues to be determined, any applicable paragraphs of the Terms of
Reference and any relevant law.
2.1 Is the FSP entitled to deny the claim?
Onus is on the FSP to establish an exclusion applies.
The applicant bears the onus of establishing a valid claim for which the policy
responds.
The applicants commenced a policy with the FSP on 5 May 2015 which expired on 5
May 2016 and further policy commencing on 26 July 2016.
They lodged a claim with the FSP on 3 August 2016. The applicants’ policy is a
defined event policy. This means the policy responds where one or more listed
events caused damage to the applicants’ property, subject to any exclusions.
I accept the applicants have established a valid claim.
The FSP must demonstrate on the balance of probabilities the cause of the disputed
damage was a policy exclusion or it is otherwise entitled to deny the claim.
Expert opinions
It has been accepted by the experts that the property is built on extremely reactive
clay soils and is reactive to changes in the ground moisture. It is also accepted that
the damage to the property is the result of ground movement.
The applicants appointed an engineer F who visited the premises on 28 February
2017. He provided a substantial report dated 21 April 2017 and as part of that report,
F reviewed the report by the FSP’s consultant, B. F noted that there was an event
caused by sewage and stormwater pipes leaking and said in its ‘ opinion that the
event did cause, or contribute to, the observed heave related damage to the northern
and eastern extents of the subject house, in particular, the observed damage both
internally and externally in the rear entry, laundry, bathroom and part of the kitchen,
or living. ’
F further was of the opinion ‘ that the damage to the subject house has been caused
by localized heave as a result of discovered leaking pipes on the western, eastern
and northern side of the house. The leaking pipes have changed the moisture
condition of the reactive clay soils which resulted in differential movement of the
soils. ’ F reached a conclusion ‘ and it is F’s opinion that damage to the house has
been caused or contributed to, as a result of leaking sewer and storm water pipes. ’
Case No: 487691 Determination Page 3 of 4
F stated further that it was its ‘ considered opinion that the change in circumstances
brought about by the discovered leaking sewer and storm water pipes has caused or
contributed to the observed damage in the subject house. ’
It is noted that F in undertaking his report had considered the report of the FSP’s
representative, B and a plumbing report by S.
The FSP appointed B to undertake a report and he prepared a first report. B provided
a report on 14 November 2016. B noted that a steel tie rod had been bent over a
beam in the roof and B’s opinion ‘ should the front gable wall move, then it is likely
that the LVL beam would rotate in direct response. ’
B also noted that there were numerous trees and large shrubs close to the residence
and that the building suffered from seasonal soil movement for some time which
would account for the installation of steel tie rod system and previous repairs.
In relation to these specific questions by the applicants’ representative, F responded
to questions with answers in the following manner:
“ F confirm s that the SHS connection (and provided lateral restraint) to the tie rod
system which runs through the roof void to restrain the front gable is supported by
the footing in the laundry which is immediately adjacent to a discovered water leak as
documented in the leak investigation report…”
“in F’s opinion, given the location of the SHS footing and location of the discovered
water leak, the identified local heave in the laundry would likely cause the SHS to
heave and rotate slightly, and thereby release the tension of the tie-rod system which
could (would have) led to consequential cracking/movement of the front gable wall
and/or the entry area of the residence.”
B was unable to state when the pipes (water leaks) started.
B undertook another report on 5 Janua ry 2018. B substantially disagreed with F’s
report, B specifically looked at F’s report and made the following observations and
specifically as to whether there was heave movement in the laundry area, stated:
“ we reiterate that despite assertions of recent heave, at the time of our own
inspection there was no visible distress to the floor tiles in the laundry/WC, nor was
there any significant distress to the north elevation wall, which would have been
closest to the reported water leaks. Also, had the SHS post footing heaved, then we
would have expected to have seen some degree of displacement at the floor
intersection.’
B stated “after due consideration of the further evidence presented to us, we maintain
our opinion as documented in our report dated 14 th November 2016”.
The report between the applicants’ specialist and the FSP’ s specialist are at odds.
On balance, I find the information provided by B to be more compelling. The fact that
the property had had substantial repairs previously and the current reports leads me
to the conclusion that the damage is caused by seasonal change which may be
exacerbated by the leaking pipes. The information in relation to the source of the
leaks by both experts does not discount the likelihood that it occurred before 5 May
2015, which was the earliest inception date for cover by the FSP.
Case No: 487691 Determination Page 4 of 4
Proximate cause
F in his report says part of the damage is caused by the leaking pipe, however does
not rule out ground movement. B also considers the leaking pipes needs to be
repaired to help rectify the problems, but states the ground movement has caused
the cracks.
I am of the opinion the dominant or proximate cause is the seasonal ground
movement
The policy does not cover the seasonal ground movement and even if I were to
accept that the damage is due to an insured event (which I do not) it is likely it
occurred prior to the commencement of the policy.
In view of this, I determine that the FSP is entitled to deny the claim.
Recommendation
Case No: 487691 Recommendation Page 1 of 8
Case number: 487691 20 November 2017
3 Overview
3.1 Dispute
The applicants lodged a claim under their policy for damages to their home caused
by water leak from numerous pipes.
The financial service provider (FSP) assessed the damage and declined the claim.
In doing so, the FSP’s engineer says d amage to the dwelling arose from seasonal
moisture changes and the drying effect of the adjacent trees. The FSP also says the
claimed damage manifested before the policy commenced.
The applicants appointed their own engineer who considers the water leak was the
likely contributing factor in the resultant damage to the dwelling.
3.2 Issues and key findings
Is the FSP entitled to deny the claim?
On balance, I accept the claimed damages likely manifested before the policy
commenced.
Even if I accept damage occurred after the policy co mmenced, I find the FSP’s
engineer opinion more persuasive than the applicants experts. The FSP’s engineer
attributes the claimed damage to seasonal ground movement, for which the policy
does not cover.
For the above reasons, the FSP is entitled to the ap plicants’ claims.
3.3 Recommendation
This recommendation is in favour of the FSP.
The FSP is entitled to deny the applicants’ claim.
Case No: 487691 Recommendation Page 2 of 8
4 Reasons for recommendation
4.1 Is the FSP entitled to deny the claim?
Applicants established a valid claim
The applicants carry the initial onus to establish any loss or damage arising from an
event is covered by the terms and conditions of the policy. This is known as a valid
( prima facie ) claim. Only once this occurs does the onus shift to the FSP, in seeking
to deny the claim, to establish a policy exclusion applies.
The applicants’ policy is a defined events policy. This means the policy only responds
where one or more of the listed events causes damage to the applicants’ property ,
subject to any exclusions.
The applicants’ claim relates to damage to their property, which they consider
occurred from ground movement caused by an escape of liquid. The parties do not
dispute there is a water leak at the property. For this reason, on balance, I accept
the applicants have established a valid claim.
Accordingly, it falls to the FSP to demonstrate on the balance of probabilities the
cause of the disputed damage was a policy exclusion or is otherwise entitled to deny
the claim.
Property has been subject to movement and cracking damage
The applicants commenced the home building policy with the FSP on 26 July 2016.
On 3 August 2016, the applicants contacted the FSP to lodge a claim. In doing so,
the applicants told the FSP they identified movement damage to various areas of the
property.
Furthermore, the applicants say:
they only came aware of the damages following the tenants vacating the
property on 31 July 2016
the property manager carried house inspection in May 2016 and no cracks were
identified
applicant (A) re-plastered previous cracks throughout the property.
Experts have provided differing opinions
All experts appointed by the parties agree the property is built on extremely reactive
clay soils and is reactive to changes in moisture. They also agree there is movement
damage to the property.
However, the experts have provided differing opinions about what caused the
differential foundation movement.
The FSP appointed an engineer (B), who in his report, says:
there are numerous trees and large shrubs within relatively close proximity to
the residence
no paving along the eastern and western elevations
Case No: 487691 Recommendation Page 3 of 8
the building suffered the effects of seasonal soil movement for some time which
would account for the installation of steel tie rod system and the previous
repairs.
Based upon B’s re port, the FSP denied the claim, saying the damage occurred
before the policy commenced.
The applicants disagreed and engaged their own engineer (F). In his report, F says:
vegetation growth close to the house along the north and east elevations
settlement style cracking and historical repairs
the house suffered differential settlement in the past as a result of seasonal soil
movemen t
trees in close proximity to the subject hous e exacerbated the soil movement.
Proximate cause of damage must be established
In order to determine whether the applicants’ claim falls within an insured event, it is
necessary to determine the proximate cause of the loss. What is the proximate cause
of the loss is the question of fact depending upon the circumstances of each case.
It is well established that a proximate cause is not necessarily the first or last or the
sole cause of the loss. It is the effective or dominant or operative cause of the loss. If
there are several causes operating contemporaneously, then each must be
examined for the qualities of predominance and efficiency as the active efficient
cause that sets a relevant train of events in motion.
Courts have said that if one cause would have resulted in the harm in any case and
the other would not have done so in the absence of the first, then the first is the
proximate cause.
The proximate cause of the damage was ground movement
The FSP says while the policy covers damage from many listed events, there is no
listed events to cover resultant damage from ground movement. Further it says the
damage was pre-existing before policy inception.
F attributed parts of the damages to the heave created by the leaking pipe. However
F did not rule out ground movement to be the dominant or proximate cause to the
leaking pipe and subsequent damages. At best, F says the leaking pipe contributed
to the damage caused by ground movement.
On balance, I find B more persuasive. This is particularly because:
forensic analysis for the sequence of events confirms the proximate cause to be
ongoing ground movement
the distress is a recurrence of previous cracking
there is no adequate paving and lack of provision for storm water away from
property
settlement of the house is in the direction of trees.
There may be circumstances in which it is proper to conclude there are two causes
which are equal or at least nearly equal in their efficiency in bringing about a loss. In
Case No: 487691 Recommendation Page 4 of 8
the current dispute however, I am satisfied ground movement can properly be
described as the effective cause of the loss. It is clearly the most decisive cause.
Having considered the material provided, I am satisfied the proximate cause of the
disputed damage to the property was ground movement. There is also no available
information establishing this damage manifested after the policy commenced.
FSP entitled to deny the claim
H aving considered the material provided and the FSP’s policy terms, I am satisfied
on the balance of probabilities, the FSP was entitled to deny the claim. This is
because:
the applicants did not establish the damages fully manifested itself while the
FSP was on risk from 26 July 2017 to 1 August 2017
even if the applicants established this, there is no listed event which covers loss
or damage caused by ground movement.
Case No: 487691 Recommendation Page 5 of 8
5 Supporting information
5.1 Key documents
Record Key points
FSP’s builder (U )
Report
05 - 08 - 2016
The façade to the front elevation of the dwelling is moving away from the
rest of the structure.
Extensive cracking to the solid brick walls throughout the lounge, dining,
entrance, hallway, kitchen an d master bedroom.
The most extensive cracking is internally to the wall bet ween the lounge
and entrance and the walls associated with this.
We also noted some minor wat er staining to the ceiling in the second
bedroom and dining area.
There is also damage to the solid timber flooring in the third bedroom and
investigation is required to confirm the cause of this.
FSP’s engineer (B)
Report
14 - 11 - 2016
Vertical cracking not ed above the doorway, also note previous repairs.
Cracking distress was noted to the f ireplace, also not e cracking distress
at the cornice to ceiling intersection.
Diagonal cracking and evidence of previous repairs noted, also note
cracking distress at the cornice to wall.
Diagonal cracking was noted at various locations about the residence .
Horiz ontal cracking was not ed bet ween the window and doorway.
Cracking distress was noted at the cornice of wall intersection.
Compression cracking and evidence of previous repairs was not ed at
various locations about the residence.
Upon ent ering the roo f void, we noted that the newer portion of the ceiling
has not been back blocked.
The steel tie rod appears to be bent due to it running over the LVL beam.
Should the front gable wall move, then it is likely that the LVL would
rotate in direct response.
Th e front gable is restrained by a steel plat e and tie rod system that runs
through the roof void.
Additional strutting has been installed to the hip rafter, also note the sag
in the underpulin in the background.
An additional LVL strutting has been added at some time in the past.
The tie rod system is connected to a SHS in the cupboard of the rear
laundry room.
View showing the steel plate and tie rod restraining system at the front of
the residence.
Cracking distress was noted at various locations externall y.
Note the witness line to the downpipe.
Note there is no pathway adjac ent to the eastern elevation.
There are numerous trees and large shrubs within relatively close
proximity to the subject residence.
Externally we noted several areas where repairs have been carried out to
the render, as well as patching of the feature pillar beneath the verandah.
Case No: 487691 Recommendation Page 6 of 8
The residenc e does not incorporate any form of paving along its eastern
or western elevations, relying gravel/metal to drain rain and stormwater
away from the vicinity of the residence.
The roof framing appears to be showing signs of wear that requires a
comprehensive overall. Clearly the roof has been modified/repaired in the
past.
In each case, it would appear that the replacement/additions have been
done to c ounter existing issues.
Considering the drains appear relatively new, it would be fair to say that
they have been replaced out of necessity. Rather than by choice.
This may also account for the east and western elevations no longer
having concrete paving t o their peripheries.
During our attendance we noted that the large tree situated adjac ent the
northwest corner of the allotment appeared to have died. Our research
via satellite imagery suggests that this occurred during late 2014 to early
2015.
The tie ro d was installed sometime between 2007 and 2009.
We are of the opinion that prior to the poisoning or death of the large tree
situated adjacent the northwest part of the building, the footings in that
area had been suffering the effects of foil drying, lead ing to differential
settlement. This in return would account for the bowing of the rear
underpurlin and the need to install and additional strutting beam and strut
to that area.
It is also likely that this tree, via its moisture uptak e, caused the soil to
become extremely desiccated close to the sewer drains along the
northern elevation. As the soil becomes drier, it shrinks volumetrically,
which in turn would likely have led to movement and consequential
cracking of the drains adjacent the WC and laundry a reas.
It appears the drainage leaks are located towards the rear northern
elevation, gradually diminishing eastwards followed by still diminishing
volume losses along the eastern elevation.
We are of the opinion that the building has suffered the effects o f
seasonal soil movement for some considerable time, which would
account for the installation of steel tie rod system sometime around 2008
and the numerous previous repairs having been carried out.
The most likely cause of the original settlement of the footings towards a
south easterly direction would appear to have been the trees that
previously occupied the front garden.
The trees were removed during a period between 2007 and 2008, which
would have been during the extreme drought period that raged
thro ughout the state bet ween 2006 to 2010.
During this time it is extremely likely that the drains towards the front and
east elevation of the residence suffered the effects of the shrinking soil,
causing them to break.
The breaks would have drawn the roots fr om the tree towards the drains.
Once established in the area, the roots will have continued to mop up any
available moisture causing the footings to settle in direct response.
The many locations where compression cracking has occurred suggests
that the cra cks were filled with brittle fillers, when the soil was at a
desiccated state.
We are of the opinion that during the recent spate of severe weather,
Case No: 487691 Recommendation Page 7 of 8
rain/stormwater would have been able to permeate through the gravel
pathways along the east and western ele vations causing the soil to
partially recover, whilst the internal parts of the building and the concrete
paved rear elevation would have been exposed to the same extent.
As a result the partial soil/footing recovery appears to have caused the
filled crack s to suffer compression cracking, while other areas have
cracked due to the very slight rise in footing levels. If this so, then it
suggests that the extent of the declination would have been greater than
the 50mm range highlighted in the floor level surve y.
As regards the verandah being approximat ely 50mm out of level, we are
of the opinion that the footings have suffered settlement towards the
south east corner of the residence due to the effects of seasonal soil
movement combined with the effects of the now removed trees. We are
also suspicious that the downpipe adjac ent the south western corner of
the verandah may have suffered a leak.
It is now evident in the main a recurrence of previous cracking albeit this
time more likely due to the soil undergoing a slight rec overy, rather by a
net settlement.
Applicant’s engineer
(F )
Report
21 - 04 - 2017
Heave relating cracking observed on the east elevation adjacent to the
bathroom.
Evidence of recent vegetation growt h close to the subject house along
the north and east elevations.
Obvious lean and rot ation of front gable wall.
There is a dead tree at the rear of the subject house.
Slight to moderate vertical and diagonal cracking in the hall, living,
kitchen, bedroom and bathroom.
Heave related cracking observed in the rear entry and laundry.
Compression cracking observed in the hall and living.
F reviewed the leak investigation report. The investigation concluded that
there are numerous leaks of various magnitudes ranging from 1 litre per
minute to 12 litres per min ute.
F observed settlement style cracking and historical repairs, In F’s opinion
the subject hous e has suffered from differential settlement in the past as
a result of seasonal soil movement which has been exacerbat ed by trees
in close proximity to the sub ject house.
However it is F’s opinion that the event did cause or contribute to the
observed heave related damage to the nort hern and eastern extents of
the house, in particular, the obs erved damage both internally and
externally in the rear ent ry, laundry , bathroom, and part of the kitchen,
hall and living.
Applicant’s engineer
(F )
Subsequent Report
08 - 09 - 2017
F are unable to categorical state what caused the pipes to crack. F note
that the existing pipes are a combination of PVC and earthenware. It is
we ll documented that earthenware pipes are prone to leakage,
particularly at joints.
F are unaware of when the pipes started leaking .
T he northern and eastern extents of the subject house, in particular, the
observed damage both internally and externally in the rear entry, laundry,
bathroom, and part of the kitchen, hall and living is as a result of the
discovered leaking pipes on the western, eastern and northern sides of
the house. The discovered leaking pipes has led to a change in
Case No: 487691 Recommendation Page 8 of 8
circumstances in the soil moisture cont ent of the reactive clay soils,
causing localised heaves, resulting in the observed cracking damage in
the rear entry, laundry, bathroom, and part of the kitchen, hall and living.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.