Determination 486779
Refusal of water damage claim under escape of liquid cover
Summary
The owner of units under a strata policy claimed water damage from a cracked balcony drain. The FSP denied the whole claim as wear and tear. AFCA found the exclusion not established, ordered a cash settlement of $66,878.35 plus interest, and $1,500 non-financial loss.
The insurer bears the onus of establishing an exclusion, and the escape of liquid was the dominant cause of loss that the insured could not reasonably have known about.
Subjects and remedies
home or building damagepay claimpay interestpay non financial loss
Text of the determination
Determination
Case No: 486779 Determination Page 1 of 8
Case number: 486779 9 July 2018
1 Overview
1.1 Dispute
The applicant held a Strata Insurance Policy with the financial services provider
(FSP). On or about 14 July 2016 he lodged a claim for water damage to unit 7. Initial
investigation revealed a cracked pipe in the drain of the balcony of unit 10 above was
the cause of the damage.
Following further investigation, the FSP denied liability for damage to both units on
the grounds that the damage was caused by gradual deterioration and wear and tear.
The applicant disputes the FSP’s decision.
1.2 Issues and key findings
Has the applicant established a claim from the terms of the policy?
The panel is satisfied the applicant has established a claim for accidental damage
due to the escape of liquid within the terms of the policy.
Is the FSP entitled to refuse payment of the applicant’s claim?
The panel is not satisfied the FSP has established the application of an exclusion
Under the specified event ‘ escape of liquid ’ , wear and tear or loss or damage by the
escape of liquid occurring as a result of a gradual process is only excluded when you
could reasonably be expected to be aware of this condition. The panel accepts that
the applicant could not reasonably be expected to be aware of the escape of liquid
causing damage to the property until notified by the tenant in June 2016.
Is the applicant entitled to compensation for non-financial loss?
The panel is satisfied that the applicant is entitled to compensation for non-financial
loss due to the claims handling by the FSP.
1.3 Determination
This determination is in favour of the applicant.
The FSP is to cash settle the applicant’s claim as set out under section 2.2 of this
determination for $66878.35 plus interest under section 57 of the Insurance
Contracts Act 1984 from 19 October 2016 to date of payment of the claim.
In addition, the FSP is to pay the applicant the sum of $1,500 compensation pursuant
to paragraph 9.3 of the Terms of Reference.
Case No: 486779 Determination Page 2 of 8
2 Reasons for determination
It has been considered appropriate to expedite this dispute in accordance with the
operational guidelines to the FOS Terms of Reference. In view of the complexity of
the dispute it was referred to a panel for determination.
The panel is satisfied that there has been a full exchange of all material between the
parties and each party has had the opportunity to address the issues that arise from
the information exchanged.
This determination is based on what is fair in all the circumstances having regard to
the relevant legal principles, terms of the policy, good industry practice including
codes of practice and prior determinations where applicable.
2.1 Has the applicant established a claim under the terms of the policy?
No dispute the applicant’s claim is valid
The applicant’s policy is a Strata Insurance Policy covering a number of units at the
applicant’s property.
The policy provides cover for accidental loss or damage which is defined as loss or
damage that was not intentional. Accidental loss or damage includes loss or damage
referred to in a number of insured events on page 14 to 21 of the policy. Included in
the insured events is cover for the escape of liquid.
There is no dispute between the parties that damage has been sustained to the
balcony on unit 10 and the ceiling and floor of unit 7 below due the escape of liquid.
There is no dispute that such loss or damage was unintentional and therefore
accidental within the terms of the policy. The panel accepts the applicant has
established a valid claim within the terms of the policy.
2.2 Has the FSP established the application of an exclusion?
The onus is on the FSP if it is to refuse payment of the claim to establish the
application of a relevant policy limitation or exclusion.
The FSP relies on the general exclusion contained in the policy that refers to wear
and tear and gradual deterioration. It has also referred to the failure to comply with
relevant building regulations.
FSP says proximate cause of damages to both units were excluded causes
The FSP says the proximate cause of the damage to both units is:
the construction of unit 10’s balcony not complying with relev ant building
regulations
wear, tear and gradual deterioration occurring over time and as a result of many
storms, rather than damage resulting from a single event.
Case No: 486779 Determination Page 3 of 8
Proximate cause of damage is the dominant and effective cause of the loss
It is well established that in determining whether an event is covered or excluded, it is
necessary to first determine the proximate cause of the loss is. The proximate cause
is not necessarily the first, last or sole cause of the loss, but it is the effective or
dominant cause of the loss.
Reports identify the escape of liquid is the proximate cause of the loss.
Various reports and comments have been provided by the FSP with respect to the
cause of the loss.
The initial building assessment report identified damage to the ceiling, window,
architraves and timber flooring of unit 7 due to water entry through the balcony. The
report noted the chipboard substrate was not suitable. It did not say that it did not
comply with the relevant building codes at the time the building was built.
The FSP’s assessor in a report of 11 August 2016 reported that the waterproof
membrane had failed and rejected the claim on the basis that the minimum code
construction for balconies was insufficient. The panel struggles to understand how
this is a valid basis for rejecting a claim if the applicant had complied with at least the
minimum code for construction of the balcony. The FSP has not provided any
information to prove that the applicant had not complied with the relevant codes.
The assessor conceded that if the CCTV showed a leaking pipe then he would
review the claim.
A leak detection report was obtained from ALD following inspection of the property on
22 August 2016. Tests conducted include a CCTV camera inspection and inspection
to the suspended stormwater line. Both tests failed. The report identified that there
was a crack located just below the chrome grate dress ring of the floor waste of the
balcony on unit 10. It extended down and the particle sheet floor could clearly be
seen. There were areas where the floor tiles had moved causing large hair line
cracks to appear in the tile grout.
ALD related the damage to the crack in the floor waste drain.
On 16 September 2016 the FSP’s builder JPF identified the damage was due to the
escape of water which he considered due to a lack of waterproof membrane. The
assessor then confirmed that after reviewing this report it was clear that the drain had
cracked and had caused damage to the sub-floor resulting in the entire balcony floor
needing replacement.
The assessor’s report was qualified by consideration that there may be some non-
claim related damage. The applicant has not sought cover for non-claim related
damage.
The FSP had a further leak detection test conducted by ML in February 2017. It was
only after this report that the FSP decided to decline the entire claim on the basis of
wear and tear and gradual deterioration. The panel notes that ML did not inspect or
test the surface, grate or drain of the unit 10 balcony. He did not do this because of a
waterproof membrane being placed over the balcony to prevent further damage. ML
identified what he believed for some design faults with the fall of the balcony but the
Case No: 486779 Determination Page 4 of 8
panel notes he has not commented on whether this could be associated with the
damage sustained to the balcony as a result of the leaking drain pipe.
In fact, the report does not comment on the possible damage caused by the cracked
or damaged drain.
The panel is concerned that the FSP’s reliance upon the report given that the test
was not conducted until nine months after the incident as indicated by the applicant.
The test does not appear to have taken into account possible floor damage that had
occurred, or to apportion the loss or damage that may have occurred as a result of
any building faults as against the leaking drain.
The panel accepts that the damage most likely arose gradually over time due to the
escape of liquid as a result of the damaged drain.
Applicant could not reasonably have been aware of the damage
Cover for damage caused by wear and tear or loss caused by gradual process of
leaking, splashing, dripping or overflowing is excluded unless the insured could not
reasonably be expected to be aware of the condition.
Whilst the applicant built the units, he did not live in them. He did not live in unit 10 or
unit 7. He only became aware of the damage when notified by a long-term tenant
from unit 7.
The panel accepts in these circumstances that the applicant could not reasonably be
expected to be aware of the condition of either the balcony to unit 10 or the condition
of unit 7.
T his is reinforced by the uncertainty expressed by the FSP’s assessor in determining
the extent of the claim related damage and cause of the damage.
No evidence of breach of building regulations
There is no suggestion in the information provided that the building was not
compliant with relevant building codes at the time of construction or that the
construction had not been approved and signed off by the relevant authorities.
The FSP has provided no information as to the relevant building regulations or other
regulations or codes which it says had not been complied with.
The applicant has provided the FSP with access to the relevant building surveyor
who signed off the various stages of the works. The FSP has not provided any
information to establish any fault on behalf of the building surveyor.
As indicated earlier in this determination, whilst the assessor may say the relevant
building codes were not sufficient, the obligation on the builder was to comply with
the codes that were relevant at the time of construction.
The FSP is liable to meet the applicant’s claim
The FSP is liable to meet the applicant’s claim for the cost to repair the balcony on
unit 10 and the damage sustained to unit 7 as a result of the escape of liquid
Case No: 486779 Determination Page 5 of 8
The applicant has provided a quote in October 2016 for damages totalling
$64,727.10. The FSP has provided a more detailed and itemised quote from JL
totalling $68,309.57 dated 7 December 2016.
This quote identifies there may be variations required if the sub-floor has rotted. The
applicant in discussion with the FSP and FOS has confirmed that he does not claim
for the variations.
The applicant completed repairs to the balcony on unit 10 but has not completed
repairs to unit 7. He has indicated that he is not seeking loss of rent for unit 7 but is
seeking 25 days loss of rent for unit 10 being a total of $2,151.35.
As the applicant has completed some of the work, the panel considers it is fair in the
circumstances that the FSP cash settle the claim. The FSP must cash settle the
claim based on the applicant’s quote of $64,727 plus the loss of rent of $2,151.35
making a total payment of $66,878.35.
The FSP should pay interest to the applicant on the cash settlement amount
calculated in accordance with section 57 of the Insurance Contracts Act 1984 (the
Act) from 19 October 2016 being the date of the quote until date of payment of the
claim.
2.3 Is the applicant entitled to compensation?
Paragraph 9.3 of the Terms of Reference provides that the Service may award
compensation for non-financial loss where a person has experienced an unusual
degree of inconvenience or time taken in the resolution of the claim. The maximum
compensation that can be awarded is $3,000.
FOS takes a conservative approach when awarding compensation of non-financial
loss and expects an applicant to be moderately robust and bear a normal degree of
inconvenience experienced when a problem occurs.
The panel notes that the FSP took a considerable period of time before ultimately
denying the entire claim. It had at various times accepted the claim, offered to
partially accept the claim and made cash offers to settle the claim. It appears that it
had only sought further information when it could not agree on a suitable cash
settlement. It initially sent the quote obtained from its builder in a redacted form. It
does not explain why this occurred.
In the panel’s view, the applicant has exp erienced an unusual degree of
inconvenience as a result of the claims handling by the FSP. In the circumstances,
the panel considers it fair that the FSP pay an amount of $1,500 by way of
compensation for non-financial loss pursuant to paragraph 9.3 of the Terms of
Reference.
Case No: 486779 Determination Page 6 of 8
3 Supporting information
3.1 Policy terms
What you are covered for
Building cover
When we insure your building, we will cover it for accidental loss or damage at the insured
address in the period of insurance provided that the loss or damage is not excluded and
subject to the conditions of your policy.
Accidental loss or damage
Accidental loss or damage is loss or damage that was not intentional and includes loss or
damage from the incidents shown on pages 14 to 21.
Escape of Liquid
We Cover Loss or damage caused by scape of liquid.
Note: additional excess applies. See page 48 for details
We do not cover wear and tear, or loss or damage by the escape of liquid
occurring as a result of a gradual process of leaking
splashing, dripping or overflowing over a period of time
when you could reasonably be expected to be aware of this condition.
Loss of rent following an insured incident
If we accept your claim for loss or damage to a tenanted unit in your building due to an
insured incident and we agree the unit cannot be lived in, we will pay the unit owner the
weekly rental amount for the reasonable amount of time we decide it should take to repair
or rebuild your building or unit so it can be lived in again.
General exclusions
You are not covered under any section of this policy for damage, loss, cost or legal liability
that is caused by, arises from or involves:
Consequential losses or extra costs following an incident covered by your policy
Consequential loss (financial and non-financial loss) or extra costs following an incident
covered by your policy such as:
loss of rent except as expressly covered by your policy;
loss of income or wages;
[ … ]
loss or costs, including the loss of or cost of your time (eg. Inconvenience), to prove
your loss or to help us with your claim (e.g. telephone calls, postage);
[ … ]
any loss or costs not covered by your policy;
Not complying with building regulations
Your building not complying with building laws or regulations, except those laws or
regulations introduced after your building was originally built or last altered which you were
not required to comply with.
Wear, tear and gradual deterioration
Wear, tear, rust, fading, rising damp, mould, mildew, corrosion, rot, action of light,
atmospheric or climatic conditions or gradual deterioration such as, but not limited to:
tiles and their adhesive grout breaking down;
weathering of roof tiles or roof ridge capping;
gradual weathering and breakdown of bricks, mortar or concrete.
Case No: 486779 Determination Page 7 of 8
3.2 Expert reports
Record Key points
FSP’s builder ( HR )
Report Assessment
Undated
Applicant advised repairs cannot commence until
maintenance repairs were completed. Applicant agrees.
Waterproof membrane under balcony floor tiles failed which
allowed water ingress on the damaged areas below.
No indication of storm damage to the roof area above the
water damaged internal areas ( to explain wat er ingress).
Cost of likely repairs expected to exceed $15, 000.
High possibility the floor joists are damaged as well from the
long term water ingress through the balcony.
Unit 10 balcony dimensions are 4.10m x 2.80m x 3.30m
(11.48m2 floor sp ace)
Scope of Works provided for Unit 10: balcony; Unit 7: kitchen,
passage, balcony; external scaffolding.
FSP’s plumber ( ALD )
Report
22 - 08 - 2016
Carried out investigation of Unit 10 balcony.
CCTV camera inspection of the storm water line failed.
Inspection of the suspended storm water line failed.
Floor waste drain inspected and a crack observed just below
the chrome grate dress ring, extending down 80mm.
There are areas where the floor tiles have moved causing
large hairline cracks to appear in the tile grout.
Particle board flooring used under the levelling screed for the
balcony tiles will need to be replaced as it is swollen; whole
area will then need to have a quality membrane installed
before retiling of the balc ony can be completed. Only th en
can the plaster ceiling to the unit below be repainted.
FSP’s assessor (PC)
16 - 09 - 2016
Expert Review
After reviewing report prepared by ALD it is clear the drain
cracked and caused damage to the balcony subfloor .
Entire balcony subfloor needs to be rem oved and reinstated
as it is impossible to only replace one section without
disrupting the waterproof membrane.
Applicant informed the FSP will accept the cost to remove the
tiles and the subfloor, re - sheet, waterproof and retile.
Damage in Unit 7 related to the leaking drain accepted also.
FSP concerned balc ony not properly waterproofed and there
remains the possibility damages to the balcony would be
found which are not relat ed to the cracked drain.
There is a good possibility damages to the joists are no t
related to the claim but are instead caused by poorly installed
subfloor and waterproofing.
Discussed with applicant, who was advised if FSP
commences repairs and non - claim related damages found,
FSP will down tools and the applicant will have to complet e
his own repairs before FSP trades return. Applicant still wants
FSP to provide repairs rather than cash settle.
FSP agrees to send builder to prepare complete SOW.
FSP’s assessor (ML)
Reins pection Report 1
16 - 02 - 2017
All parties walked through apartments 7 & 10 to view the
balcony and resulting damages.
Applicant says FSP builder carried out make safe to balcony
by applying tape over the drain grat e and applying a water
proof membrane over the entire tiled area. FSP experts on
site agree this wa s not the preferred option.
No puddle flanges on the balcony drain (which are required)
& the PVC waste pipe is only 40mm which is too small.
The applicant says the apartment plans were approved.
Other building code issues regarding the balcony and
Case No: 486779 Determination Page 8 of 8
plumbin g leaks identified.
FSP requests design plans to confirm whether building built
to specification & whether design faults in play.
FSP’s plumber (LTV)
Leak Detection Report
03 - 03 - 2017
Balcony surface grate and drain could not be tested on
account of waterp roof membrane installed during mak e safe.
No step down to the balcony present and the finished floor
level of the internal floor is the same height. This means
correct waterproofing cannot be achieved.
No skirting tiles were installed and there was an area with
incomplet e render. Upon further ins pection it was found there
was no waterproof membrane in this area. It appears the
waterproof membrane detailing is incomplete.
On the front edge of the balc ony, the tiles butt up to a flashing
on the adjacent roof. On the side edge, the tiles flow onto a
flashing which runs into its own gutter.
Water staining present on the ceiling of the living room in the
apartment below. Thermal imaged this area which appears to
be dry.
Underneath the Unit 10 balc ony there is a lot of water staining
and damage present. Particle timber linings under the
balcony have been affected by water and are rotting. Water
damage to the compressed cement sheeting installed on top
of the particle flooring which is cracking and falling apart. T his
cracking damage will be affecting the waterproof membrane.
Balcony water - sprayed to test direction of flow. Water
overflowing the front edge and then into the timber linings and
under the balcony itself. This water should be flowing ont o the
roof below and then into its own drain. This is a design fault.
Were the balcony correctly designed and installed correctly
no water would be entering the linings under the balcony.
Observed water dripping below was in the same areas as
visible damage.
No puddle flange obs erved on the drain of the unit below
(drain of Unit 10 could not be observed). This is incorrect and
not to current standards.
“We believe the cause of damage is from incorrect
waterproofing detailing, incorrect drainage installation and
incorrec t flashing installation. These faults are causing water
to flow onto the timber linings below the balcony, which then
flow back under the balcony substrate and the living room
ceiling of the unit below.
3.3 Other key documents relied upon
Written submissions from the applicant and the FSP.
Photographs provided by the applicant and the FSP.
Quotations provided by the applicant and the FSP.