Home / Financial Firm (Unknown - Insurer) / Determination 484942

Determination 484942

Lounge room damage claim denied as foundation movement

FirmFinancial Firm (Unknown - Insurer)
Decided2018-05-16
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for lounge room cracking after a bathroom water leak, and the FSP denied the lounge damage as caused by foundation movement. AFCA found on the expert evidence that the proximate cause was seasonal soil movement and trees, not the leak, so the denial stands.

Where foundation movement is the proximate cause of loss and would have occurred without the leak, the earth movement exclusion applies.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 484942 Determination Page 1 of 3 Case number: 484942 15 May 2018 1 Overview 1.1 Dispute The applicant lodged a claim with the financial services provider (FSP) for damage to her property following a water leak in the bathroom. The FSP accepted the claim for the leaking pipe underneath the bathroom, but otherwise denied the claim for the balance of the damage. This matter has been the subject of a recommendation. The recommendation was in favour of the FSP. The applicant disputes the recommendation. A copy of the recommendation is attached. 1.2 Issues and key findings Is the FSP entitled to deny the balance of the applicant’s claim? The applicant has not established a claim for the damage to the lounge room. The FSP is entitled to deny liability with respect to this aspect of the claim. 1.3 Determination The determination is in favour of the FSP. The FSP is not required to make any further payments to the applicant. Case No: 484942 Determination Page 2 of 3 2 Reasons for determination There has been a full exchange of material between the parties and each party has had the opportunity of addressing the issues that arise from the information exchanged. I have attached the recommendation to this determination. In rejecting the recommendation, the applicant maintains:  The FSP’s engineer’s report is contradictory and could not with certainty state the tree was the cause of the damage.  The damage which occurred during the drag [drying] out period is directly related to the damaged waste pipe leak and that flooded both inside and outside the home.  That the FSP had entered into a binding agreement with the work agreed upon and that the applicant had paid the excess in response to this. This determination follows consideration of all information exchanged and is based on what is fair i n the circumstances, having regard to the relevant legal principles, terms of the policy, good industry practice and where applicable, prior determinations. 2.1 Is the FSP entitled to deny the claim in relation to the lounge room? Onus is on the FSP to establish an exclusion applies There is no dispute that the property had water damage. The FSP has accepted the water leak damage to the property. The FSP accepts there was a leaking pipe underneath the bathroom but says the damage to the lounge was not caused by the leak. The FSP says the damage was caused by earth/foundation movement which is excluded from cover. I agree with the findings contained in the recommendation. All experts appointed by both parties agree, the property is built on reactive clay soils, which shrink and expand dependent on the moisture it contains. This movement can cause cracks in property. I have considered the differing opinions between the experts based on consideration of the proximate cause of damage On balance, I find the FSP’s expert , C, more persuasive than the applicant’s expert BE. T he contradictions of BE’s report ma de by C, have not been refuted by the applicant. I agree with the findings in the recommendation. The damage to the lounge, in my view, did not arise beca use of the leaking pipe. I accept that most likely the damage arose because of earth movement. FSP is entitled to deny the claim I agree with the recommendation and I am satisfied the damage to the lounge room, the area in dispute, was caused by foundatio n movement. Although earth movement is covered in certain circumstances under the FSP’s policy, I am satisfied on the Case No: 484942 Determination Page 3 of 3 balance of probabilities that the cause of this movement was seasonal factors described by C in his report and not as described by BE in his report. In view of this, I agree with the recommendation and the FSP is entitled to deny the claim. Recommendation Case No: 484942 Recommendation Page 1 of 10 Case number: 484942 9 October 2017 3 Overview 3.1 Dispute The applicant lodged a claim with the financial services provider (FSP) for movement damage to her property following an escape of liquid from the bathroom. The FSP partially denied cover for the damages sustained to the lounge, saying the damage was not the result of the leak. Rather the damage was caused from highly reactive clay foundation soil causing differential foundation movements due to:  nearby trees and vegetation  seasonal changes. The applicant disagrees and says water ingress from the leak caused its damage. Accordingly she seek the FSP repair damages caused by the leak. 3.2 Issues and key findings Is the FSP entitled to deny the claim? On balance, I accept:  while various experts have provided their opinion on the cause of damage, I find the FSP’s engineer (C) more persuasive  C ’s report says foundation movement was the proximate cause of damage to the lounge  damage is not attributed to a single leak event (pipe leak)  the policy does not provide cover where the proximate cause is foundation movement. For this reason, the FSP is entitled to deny the cover for the damages sustained to the lounge. 3.3 Recommendation This recommendation is in favour of the FSP. Case No: 484942 Recommendation Page 2 of 10 4 Reasons for recommendation 4.1 Is FSP entitled to partially deny the claim? Applicants established a valid claim It is an accepted principle of insurance law the applicant bears the onus of establishing, on the balance of probabilities, she suffered a loss caused by a risk covered under the policy. This is called a valid, or prima facie , claim. The FSP accepts a water leak damaged parts of the property. Given this, I am satisfied the applicant has established a valid claim. The FSP says however the cause of the damage to the lounge was not the water leak. Accordingly, it falls to the FSP to demonstrate, on the balance of probabilities that the disputed damage was caused by a policy exclusion. Property has been subject to movement and cracking damage The applicant contacted the FSP to lodge a claim on 2 August 2016 for damage related to a leaking pipe underneath the bathroom. The FSP accepted the claim and engaged a builder to report on the nature and extent of damage. Parties agreed to hold repairs for a six months drying out period before finalising a scope of works and commencing repairs. The applicant noticed further cracks to the concrete slab and requested a re- assessment, subsequently the FSP engaged its engineer (C) to report further. Due to findings of C’s report, the FSP declined cover for cracks to the lounge area (zone 2). Experts have provided differing opinions over zone 2 All experts appointed by the parties agree the property is built on reactive clay soils which changes in moisture. However, the experts have provided differing opinions about what caused the differential foundation movement. C says the likely factors contributing to the differential foundation movements were:  seasonal moisture changes  drying effect of the adjacent trees. Furthermore C concluded:  a heave has not occurred as there were no diagonal cracks in the walls.  articulation joint at the northwest corner of the lounge and floor levels taken suggest the east end of the lounge room extension has settled. Subsequently the applicant engaged her own engineer (BE) who reported the leaks in the subfloor was the likely cause of the damage. BE says:  no cracks to lounge eastern wall (W3).  lounge eastern wall (W3) heaved up above concrete paving line.  olive tree did not affect the lounge or its footings. Case No: 484942 Recommendation Page 3 of 10 BE discounts C’s observation in relation to close proximity of trees, in doing so, BE states the trees are no threat to the foundations. Proximate cause of damage In order to determine whether the applicant’s claim falls within an insured event, it is necessary to determine the proximate cause of the loss. What is the proximate cause of the loss is the question of fact depending upon the circumstances of each case. It is well established that a proximate cause is not necessarily the first or last or the sole cause of the loss. It is the effective or dominant or operative cause of the loss. If there are several causes operating contemporaneously, then each must be examined for the qualities of predominance and efficiency as the active efficient cause that sets a relevant train of events in motion. Courts have said that if one cause would have resulted in the harm in any case and the other would not have done so in the absence of the first, then the first is the proximate cause. Proximate cause of the lounge damage was foundation movement The FSP relies upon the general exclusion contained within the policy. Particularly it says the policy does not cover loss or damage caused by or as a result of: erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement. However the FSP says it will cover subsidence damage to the home if it is caused by the insured event of burst pipes, leaks and overflows. Whilst a leak report, obtained by the FSP, identified numerous instances where the downpipes discharged stormwater onto the ground, the discharge was not located in close proximity to the lounge. In the current dispute, C says floor levels contradicts BE’s theory Wall 3 heaved. I accept C’s findings and on balance I find C more persuasive. This is particularly because:  if moisture increased in foundation soils as a result of water ingress, the soils would be expected to have swelled (rather than shrunk), resulting in local heave.  floor level survey in vicinity of the leak show local heave has not occurred  there are several trees in close proximity to the property  there has been a relative settlement towards the eastern region of the house, which is in the direction of a number of medium to large size trees.  BE have used the rule of thumb that the height of the tree is less than the distance from the centre of the tree to the residence  The shape orientation of the lounge room cracks and the opening of the top of the articulation joint suggests that subsidence has occurred at the east end of the lounge, near the trees and not at the west end of the lounge near the escape of water event. In these circumstances, applying relevant legal principles, as foundation movement would have occurred in the absence of the leaking pipes, then I am satisfied the Case No: 484942 Recommendation Page 4 of 10 proximate cause of the loss was the foundation movement. The documentation suggests the foundation movement was independent of any damage caused by the pipe leaks. FSP is entitled to partially deny the claim Having considered the material provided, I am satisfied the disputed damage to the property was caused by foundation movement. I am also satisfied the material establishes the proximate cause of the disputed damage to the property was caused by foundation movement. The FSP’s po licy is clear and unambiguous. Although earth movement is covered, save in certain circumstances, it is not applicable to these circumstances. There may be circumstances in which it is proper to conclude that there are two causes which are equal or at least nearly equal in their efficiency in bringing about a harm. In the current dispute however, I am satisfied foundation movement can properly be described as the effective cause of the loss. It is clearly the most decisive cause. I am therefore satisfied on the balance of probabilities, the cause of movement damage was by seasonal factors described by C as above. Therefore, having considered the material provided and the FSP’s policy terms, I am satisfied on the balance of probabilities, the FSP was entitled to deny the claim. Case No: 484942 Recommendation Page 5 of 10 5 Supporting information 5.1 Key Documents Record K ey points Applicant ’s plumber ( V ) 21 - 01 - 2017  Came out to find water leak issue. I then broke the tiles on the side of the bath after I filled bath to then let water go.  I found the water then visible coming from outside of home with large amount of wat er leaking under the slab into the living space.  This was due to the crack in the bath waste pipe. The water was then travelling throughout the laundry, toilet and hall area.  Now made repairs of both waste, tested no further leaks. FSP ’s engineer ( C ) Report 1 02 - 03 - 2017  We observed several 2 to 3 m high tree in close proximity to the lounge room.  We observed articulation joints (AJ) in the brickwork at the junctions bet ween the original residence and the lounge room extension.  The AJ was 10mm wide at the top and 0 mm wide at the base.  No cracks were obs erved to the exterior brickwork.  We observed evidence of a wat er leak to the bathroom. Swelling of the base of the vanity adjacent to the bathtub was evident.  Hairline to 0.5mm wide cracks were observed to the tiles at the northeast and southeast corners of the bathroom.  We observed mould to the base of the south wall of bed 4 and on the adjac ent furniture. The mould (to zone 3) was located on the north face of the wall adjacent to the bathtub.  We observed a cr ack in the north wall of the lounge that extended into the lounge ceiling. The previously repaired crack was located at the position of the articulation joint in the brickwork. A crack up to 6mm wide was observed to the cornice on the west wall of the loun ge.  We observed aged cracks up to 2mm wide to the floor tiles at the northwest corner of the lounge and along the junction between the lounge and the dining room. No movement joint in the tiles was present at the junction between the lounge and the origina l residence. Tile Joints  Australian Standard AS3958.1 - 1991 - Guide to the Installation of Ceramic Tiles requires a movement joint in the tiled surface to match discontinuities in the substrate, to cater for differential ground movement.  At the junction where the lounge room slab (the extension) was joined to the dining room slab (t he original slab) there is a discontinuity in the substrate (t he slabs). No movement joint was provided at this location; refer to Figure 15. Accordingly, it is our opinion that the floor tiles do not comply with the current standards or the standards that were in place when the extension was constructed in the early 1990's. Case No: 484942 Recommendation Page 6 of 10 Trees  According to Clause 82.3 of AS2870 - Australian Standard Residential Slabs and Fo otings, planting of trees should be avoided near the foundation of a building or neighbouring building on reactive sites as they can cause damage due to drying of the clay at substantial distances.  It is our opinion that the trees adjacent to the lnsured' s residence do not comply with the above recommendation from the current standard.  We have highlighted the lack of complianc e with the current standards to notify the Insured and the Insurer that damage to the residence is more likely to re - occur if the r esidence is not upgraded to the current standards; i.e. if the drying effect of the trees is not addressed. Downpipes  It is our opinion that many of the downpipes discharging stormwat er from the lnsured's roof do not comply with the above requirements of the BCA; as the downpipes discharge water directly onto the ground rather than to the legal point of discharge. Cause of damage to zone 1  Based on our review of the leak det ection report, it is our opinion that the cracks to the bathroom wall tiles and th e swelling of the vanity base joinery was caused by escape of liquid from the shower waste pipe and the bathroom waste pipe. The proximity of the damage to the leaks supports our opinion. Cause of damage to zone 2  We understand that water that escaped from the bathroom migrated to the west end of the lounge/east end of the dining room; however, it is our opinion that heave has not occurred at this location. If heave had occurred, there would have been diagonal cracks in the dining room.  The width of the se paration gap to the top of the articulation joint at the northwest corner of the lounge in Figure 5 suggests that the east end of the lounge room extension has settled. No evidence of heave at the west end of the lounge/east end of the dining room was obse rved; no diagonal cracks in the dining room were evident.  Accordingly, it is our opinion that the cracks to zone 2 occurred as a result of settlement of the east end of the lounge room extension; rather than heave at the west end of the lounge.  Ground mo vement occurs when one area of soil experiences a different volumetric change relative to an adjacent area of soil. The Albanvale area is generally composed of reactive clay soils. Reactive clay soils expand when moisture is added, causing heaving of found ations. Conversely, reactive clay soils shrink when moisture is extracted, causing settlement of foundations. This is commonly described as ground movement.  Increases in soil moisture result in heave while reductions in soil moisture result in settlement. As settlement of the east end of the lounge occurred as a result of a reduction in soil moisture, the settlement is not related to escape of liquid; escape o f liquid increases soil moisture. It is our opinion that the settlement Case No: 484942 Recommendation Page 7 of 10 occurred as a result of seasonal moisture changes and trees. The proximity of the trees to the east end of the lounge supports our opinion.  Whilst leak report identified numerous inst ances where the downpipes discharged stormwater onto the ground, the discharge was not located in close proximity to the lounge.  The leaks to the stormwater pipes were also not located in close proximity to the lounge. Cause of damage to zone 3  It is our opinion that the mould to zone 3 was caused by escape of liquid from the shower waste pipe and the bathroom waste pipe. The proximity of the damage to the leaks supports our opinion. FSP’s leak report (A) 05 - 12 - 2016  Prior to testing insured stated that, during use of the bath, wat er pools on the bathroom and laundry floor tiles (appendix 2,3) and also appears to discharge in to the soil external to the south east comer of the laundry, at the east side of the house (appendix 4) where a large crack has star ted to appear in the internal plaster wall and the expansion join in the external brickwork has started to separate, indicating foundation movement.  Visual inspection was conducted to property.  At the southwest corner of the carport, at the south side of the house, the Down pipe which picks up the entire carport space at the south side of the house discharges on to the concrete driveway (appendix 5). At the nort hwest corner of the house the verandah roof which picks up the roof space external to the north side of the house, discharges on to the soil external to the northwest comer of the house (appendix 6). An overflow pipe has been installed to the gutter at the northeast corner of the garage which discharges on to the ground (appendix 7).  The roof for the garden shed in the backyard has had no guttering or drainage installed, allowing water to discharge on to the ground (appendix 8).  No guttering or drainage has been installed to the small roof above the outside toilet external to the nort heast corner of the garage (appendix 9).  CCTV camera inspection to PVC stormwater line was found to be holding mud and wat er in a majority of sections of the line giving the camera poor vision.  Below the down pipe external to the bedroom at the west side of the house, a large crack was found in the PVC riser (appendix 10).  CCTV camera inspection was conducted to the sewer line.  In the shower waste pipe a large crack was identified (appendix 12).  Due to the amount of grease built up in the small branch between the ORG ex ternal to the northeast corner of the kitchen and the main sewer line, the camera was unable to gain clear vision (appendix 13).  Testing was conducted to the waste pipe of the bath where water was found to penetrate through the join of the waste pipe and b at h (appendix 14). Case No: 484942 Recommendation Page 8 of 10  Static test was then conducted to the bath where wat er was found to pool below the floor tiles when viewed via thermal imaging (appendix 15) water would then eventually escape through the brick wall around the bath waste external to the northeast comer of the bathroom (appendix 16) and also drip down in to the soil external to the southeast corner of the laundry (appendix 17) where the cracking to plaster and separating of the expansion join can be seen.  It appears as though the majority of the int ernal damage is due to the leak to the bath waste, based on previous report to bat hroom by A and recent findings.  FSP ’s engineer ( C ) Report 2 16 - 06 - 2017  We reviewed the lns ured's engineers report prepared by BE dated 03/05/ 2017. Wall W3 has lifted (heaved)  We note that BE state that W3 has lifted. Based on the floor levels, we are of the opinion that W3 is lower than the west end of the lounge and that W3 has settled (sunk) rather than lifting/heaving.  BE are of the opinion that the northwest corner of the lounge lifted/heaved due to the wat er from the bathroom saturating the ground in this area. The floor levels shown in Figure 3 contradict this theory.  The highest floor levels are in bed B4 (+ 36mm) and at the south end of the kitchen (+ 37mm) . The floor levels at the northwest corner of the lounge where BE maintain heave has occurred are approximately +15mm. If BE were correct, we would expect to see the highest floor levels at the northwest corner of the lounge. The highest floor levels are a t the southwest corner of the kitchen, which is not located in close proximity to the bathroom leak.  ongoing seasonal moisture changes and trees have caused some additional floor level variations,  ongoing disch arge from disconnected downpipes has caused some additional floor level variations and  in 2017 the leaking pipe has locally caused some additional ground movement in the bathroom area. There is a high point (ridge) in the floor tiles along the junction between the lounge and dining rooms  We agree th at locally, this is a highpoint, but globally, it is more of a low point; compared to the levels in bed 4 and in the kitchen. Unfortunately for BE and C, the floor levels throughout the house vary wildly and the pattern does not neatly match any simple hea ve/settlement theory relating to trees and leaking pipes. There is an established 4.3m high tree (tree T1) 4.5m to the east of wall W3  We agree that T1 is relatively mature. BE are of the opinion that the tree is too far away to have caused any movement of the lounge. BE have used the rule of thumb that the height of the tree is less than the distance from the centre of the tree to the residence. However, this rule of thumb should be modified when there are rows/groups of trees; as there is at the lnsured's property. Case No: 484942 Recommendation Page 9 of 10  Neither BE nor C can conclusively prove or disprove that the trees adjacent to the lounge have or have not contributed to the lounge room movement.  Based on the width of the crack at the northwest corner of the lounge, after the lounge was con structed either the west end has lifted, the east end has sunk or a combination of both has occurred. The floor levels shown in Figure 3 do not support the theory that the west end has heaved as a result of the bathroom leaking pipe.  We maintain our opini on that trees have contributed to settlement of the east end of the lounge. The northwest corner of the lounge lifted (heaved) due to swelling of the underlying clay soils  We disagree, refer to item 1 response above.  We also note that BE have used the vol ume of water that escaped to justify their opinion. The volume of water that escaped has not been established.  BE have used the location of the bathroom leak to support their opinion. We noted that the bathroom leak was not located in close proximity to a ll the highpoints in the slab. FSP ’s engineer ( C ) Report 3 16 - 06 - 2017  Neither C nor the Insured’s engineer have any doc ument ation that confirms what the floor levels to the residence to the extension were (prior to the escape of Liquid Event in January 2017).  Accordingly, both BE and C have had to assess the current floor l evels and make assumptions on whether the slabs have heaved or settled as a result of the escape of liquid events.  M took floor levels on 15/03/2017. The levels taken by M are not consistent with BE’s theory that heave occurred at zone 2. The M floor level s are consistent with the C theory that the east end of the extension settled.  The shape orient ation of the lounge room cracks and the opening of the top of the articulation joint suggests that subsidence has occurred at the east end of the lounge, near th e trees and not at the west end of the lounge near the escape of wat er event. Applicant’s engineer report (BE) 03 - 05 - 2017 During out visit we observed the following:  A separation gap in the brickwork articulation joint bet ween walls (W1) and (W2) at the corner from outside, starting with 0.00 mm gap at 340 mm above soil level and finishing at the underside of eave board (approx. 2500mm high) with a 15mm gap.  A similar crack ranging from 1mm near the floor to 5mm at the ceiling.  No cracks to lounge eastern wall (W3).  Lounge eastern wall (W3) has been heaved up above concret e paving line.  A raised ridge line formed in the floor tiles with a 2 - 4 mm separation gap within the tiles grout bet ween the dinning and the lounge rooms.  The presenc e of an established 4.3 high olive tree wit h a 4.5 – 5 m canopy and 230mm diameter trunk. The tree is situated at 4.5m from the lounge eastern wall (W3). Case No: 484942 Recommendation Page 10 of 10  Considering the description and the locations of the damaged bathroom pipe and the amount of water leaking under the slab and floating into the lounge, laundry and bathrooms and with referenc e to all reports; in our opinion we are strongly convinced that the corner bet ween wall 1 and wall 2 has been raised up and developing the wall crack due to the swell of the saturated cla yey foundation, taking int o consideration that the lounge room slab edge edge beams are not continuous being a later extension to the original house.  We do not think the olive tree east of the lounge eastern wall is affecting the lounge room or its footing s due to the tree size and its distance away from wall.  We also strongly recommend that a moisture test to be carried out to check the moisture level in all affected walls and the wetted slab areas and to be dried as soon as possible.  Keeping in mind a pos sible weakening of the slab reinforcement due to water soaking which would cause possible future developing rust within the slab reinforcement.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.