Home / Financial Firm (Unknown - Insurer) / Determination 484445
Determination 484445
Water damage claim for shower repairs denied under wear and tear exclusion
Summary
A body corporate represented by an insurance broker claimed for water damage to an apartment bathroom and hallway under an industrial special risks policy. AFCA decided in favour of the FSP, finding the shower membrane failed through excluded wear and tear, and the resulting damage fell below the excess.
The FSP established on the balance of probabilities that the leak was caused by an excluded gradual deterioration of the waterproof membrane, and the claimant gave no evidence of faulty installation.
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
Case No: 484445 Determination Page 1 of 3
Case number: 484445 16 November 2017
1 Overview
1.1 Dispute
The applicant is a body corporate (applicant). The body corporate is represented in
this dispute by an insurance broker (AH).
On 14 February 2017 the applicant lodged a claim for water damage under an
Industrial Special Risks policy (Policy). The Policy was issued by the financial
services provider (FSP) on 2 March 2016.
The FSP says the source of the leak is a failure of the waterproofing membrane in
the shower recess. Damage caused by wear and tear, gradual deterioration and
developing flaws is excluded under the Policy.
The claim for repairs to the shower has been denied. The claim for the resulting
damage was accepted, but the cost of these repairs was less than the applicable
excess.
1.2 Issues and key findings
Is the FSP entitled to deny the claim?
The FSP has established on the balance of probabilities that the damage to the
shower was caused by the failure of the waterproof membrane in the shower recess.
The Policy excludes damage caused by wear and tear, gradual deterioration or
developing flaws.
I am satisfied that the FSP can rely on this exclusion to deny this part of the claim
because:
the information provided established the membrane failed, and
there is no other explanation for the failure other than events that are excluded
under the Policy.
1.3 Determination
This determination is in favour of the FSP.
Case No: 484445 Determination Page 2 of 3
2 Reasons for determination
2.1 Is the FSP entitled to deny the claim?
The Policy provides cover for material damage
Under the Policy the scope of cover is risks of physical loss of, destruction of or
damage to property not specifically excluded in the Policy document.
The Policy covers accidental damage or any peril or event, subject to exclusions. The
Policy says:
In the event of any physical loss, destruction or damage (hereinafter in Section l referred to
as 'damage' with 'damaged' having a corresponding meaning) not otherwise excluded
happening at the Situation to the Property Insured described in Section l the Insurer(s) will,
subject to the provisions of this Policy including the limitation on the Insurer(s) liability,
indemnify the Insured in accordance with the applicable Basis of Settlement.
The property sustained water damage
On 14 February 2017 the applicant lodged a claim for water damage to a bathroom
and hallway in one apartment. The claim notes say:
Bathroom damage due to water leak in the wall behind tiles
The FSP’s assessor (CL) attended the property on 23 February 2017. CL reported
that:
it was unsure of when the leak was first reported to the body corporate
the unit owner and property manager had been aware of the leak for the past
few months
the initial inspection by a plumber identified a leak within the shower base and
silicone was applied, and
no leaking pipes were discovered at that time.
CL engaged a plumber to provide a report on the cause of the damage. The plumber
(ABC) attended the property on 7 March 2017. ABC conducted leak detection tests. It
found that water was leaking from under the skirting and the tiles. There were no
leaks from pipes found. ABC reported that:
In my opinion the water leak is caused by a leaking water proof membrane and it has been
leaking for a period of 3 – 6 months before the carpet started to rot and be noticed.
The Policy excludes damage caused by wear and tear or gradual deterioration
The Policy says:
PERILS EXCLUSIONS:
The Insurer(s) shall not be liable under Sections 1 and/or 2 in respect of: -
4. physical loss, destruction or damage occasioned by or happening through:-
(b) wear and tear, fading, scratching or marring, gradual deterioration or developing flaws,
normal upkeep or making good.
Case No: 484445 Determination Page 3 of 3
Based on the information available I am satisfied that the damage to the shower was
caused by the failure of the waterproof membrane. On the balance of probabilities
this failure was due to wear and tear, gradual deterioration or developing flaws
because there is no other explanation for the failure (such as impact).
The applicant says the units are only 10 years old, therefore it would not be expected
for the waterproofing to fail if it had been installed correctly. The applicant has not
provided any evidence that the membrane was installed incorrectly.
Even if the applicant could establish the membrane failed because it had been
installed incorrectly, the policy also excludes damage caused by faulty materials or
faulty workmanship.
Claim decision based on these facts and this Policy’s terms and conditions
The applicant says that:
many property claims are accepted where water proofing either fails or was
never put in place, and
in those cases the insurer accepts the claim and puts the bathroom back to
current building standards.
The circumstances of other claims and policies are not relevant to this claim.
The FSP is entitled to rely on the terms and conditions of the Policy. As the FSP has
established that the proximate cause of the damage is excluded from cover under the
Policy, it is entitled to deny the claim for the shower.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.