Text of the determination
Determination
Case No: 483243 Determination Page 1 of 8
Case number: 483243 9 May 2018
1 Overview
1.1 Dispute
The applicant lodged a claim with the financial services provider (FSP) for damage to
a number of sections of his home including: the skylight vent, bathroom ceiling, TV
antenna, solar panels, inverters, solar charges and some roof panels.
The applicant says on 12 November 2016 his house was hit by lightning after which
short and unusually strong wind gusts occurred followed by rain.
The FSP declined the claim on the basis the damage arose as a result of design
faults, structural defects and faulty workmanship. The applicant accepts damage to
the carport and roof solar frame is excluded, but maintains the rest of the claim.
The applicant is also seeking non-financial loss compensation for the FSP’s handling
of the claim and a premium refund of $77.70 for the remaining policy term.
The case analyst issued a recommendation on the issues in dispute. The applicant
did not accept the recommendation so the dispute has been referred for
determination. A copy of the recommendation is attached to this determination.
1.2 Issues and key findings
Is the FSP entitled to decline the claim?
The FSP cannot decline cover for the TV antenna. However I am satisfied the
remainder of the damage is excluded from cover. I am persuaded that, on balance,
lightening or storm did not cause the damage. A number of excluded causes were
the dominant and effective cause of the damage.
Is the applicant entitled to further compensation?
The FSP’s system notes show it made the required premium refund. I agree with the
recommendation that compensation of $500 is appropriate in the circumstances.
1.3 Determination
This determination is substantially in favour of the FSP. Upon receipt of a reasonable
quote the FSP is to cash settle the applicant the cost of a new TV antenna (subject to
any excess).
It must also pay the applicant $500 within 14 days of his acceptance of this
determination. No further action is required.
Case No: 483243 Determination Page 2 of 8
2 Reasons for determination
I have decided this case on the basis of what I consider fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions. I have taken into account all material submitted by the
parties, both before and after the recommendation. I am satisfied that the
documentation I have relied on has been provided to both parties.
I am satisfied the case analyst’s recommendation contains an accurate summary of
the dispute, the issues to be determined, any applicable paragraphs of the Terms of
Reference and any relevant law.
The applicant’s reasons for rejecting the recommendation
Amongst other things, the applicant gave the following reasons for rejecting the
recommendation:
the damage caused by design faults, structural defects or faulty workmanship is
not part of this dispute because he has accepted the damage to the carport and
roof solar frame was caused by excluded causes
the claimed damage subject of this dispute is not related to the carport or roof
solar frame and is not in relation to any excluded causes
the FSP has ignored the damage to the skylight vent, bathroom ceiling, TV
antenna, 3 solar panels and 2 roof panels without explanation
the FSP continues to rely on unqualified reports and it has not provided a report
from a qualified solar power system expert
the FSP has not taken into account his calculation which show the system could
not have been overloaded
the non-financial loss suffered is greater than $500.
The applicant has also provided a new expert report dated 12 November 2017 for
consideration.
2.1 Is the FSP entitled to decline the claim?
Applicant established a valid claim
The applicant bears the onus of establishing a valid claim for which the policy
responds.
The applicant says his home was directly hit by lighting.
The FSP’s initial loss report shows the applicant advised:
My wife told me that between 3pm and 4pm last Saturday there was very strong winds and
lightning.
The applicant’s policy provides in d ependent cover for ‘lightning’ and separate cover
for ‘storm’. The policy defines ‘storm’ to be:
an atmospheric disturbance evidenced by violent wind (including cyclones and tornadoes)
that may be accompanied by lightning, rain, hail, snow or dust. Storm is not persistent rain
by itself.
Case No: 483243 Determination Page 3 of 8
The applicant has established a valid claim (also called a prima facie claim). The
onus now shifts to the FSP to establish the application of an exclusion clause.
The applicant provided a number of reports from his nominated builder
The applicant has provided a report from his builder (BI) dated 10 January 2017. The
report states the builder, ‘at tended site to look storm/light ning damage …’ The report
does not identify whether there has been any lightning or storm damage.
A supplementary report from the same builder dated 7 February 2017 , advises:
We attended site to look storm/lightning damage of above residence and confirm the strong
wind gust and lightning strike were [cause] of damage. Equipment has marks of high
voltage sparks and blackened parts.
A further supplementary report from the same builder dated 1 August 2017, states
that the following items have been damaged because of strong gusts, airwave,
pressure or vibrations created by lightning strike:
two sheets of pergola roofing
three solar panels
skylight vent unit
roof antenna
electrical equipment such as the inverter power jack, inverter JFC 2000 and
JFC 3000
two solar MTTP regulators
Samsung TV set.
While I accept the report states there has been airwave, pressure and vibrations this
does not establish the applicant’s home was directly hit by lightning.
I am not persuaded, on balance, there has been direct lightning damage
The FSP has provided its own reports from its assessor (A), builder (WB) and
electrician (RCES). Neither report identifies any direct lightning damage. The reports
accept there has been a storm event, but states the damage is inconsistent with the
applicant’s version of events as there doesn’t appear to be any direct storm damage.
The applicant has expressed dissat isfaction with the FSP’s experts and their relevant
qualifications. The applicant advised the FSP needs a report from a clean energy
solar po wer expert. I see no reason to question the validity of the FSP’s reports or
wh y each of the FSP’s experts would not be able to identify direct lightning damage if
it were present.
The applicant also provided another report after the recommendation, dated 12
November 2017, prepared by (CG) an electrical licensee with a clean energy council
(CEC) accreditation.
The report criticises the credibility of reports provided by the FSP. CG’s report
concludes that only the reports from BI should be considered and based on his
attendance at the property the damage is consistent with lightning strike. The report
states the:
blown out capacitors and power transistors show that damage was done by high voltage
and frequency impulse created by lightning strike.
Case No: 483243 Determination Page 4 of 8
Given the three reports from the FSP do not identify any direct lightning damage I am
not persuaded that the applicant’s reports from BI and CH can establish, on the
balance of probabilities, there has been direct lightning damage.
The applicant has not established a valid claim for lightning.
The applicant has established a valid claim for ‘storm’
The FSP does not dispute a storm occurred on the date of loss. The weather data for
the relevant day shows there were wind gusts followed by rain the next day.
The onus is on the FSP to show, on the balance of probabilities, the storm was not
the proximate cause of the damage and it is entitled to rely on an exclusion under the
policy, or is otherwise entitled to deny the claim.
The FSP relies on policy exclusions to decline the claim
Under the policy, cover for damage caused by storm is subject to certain conditions
and exclusions.
The policy states the FSP will not pay for any loss or damage which is caused by or
arises from:
a design fault, structural defect or faulty workmanship
failure to maintain the home in good condition
failure to take reasonable care of the home
rust, corrosion, rot, mould, rising damp, mildew, gradual deterioration, wear and
tear or fading.
The policy also states it is a condition of cover that the home is kept in good condition
and all reasonable steps are taken to prevent any loss or damage.
The FSP’s reports show the home was not in a good condition
The FSP’s reports identify the home to be highly dangerous to the occupants.
The assessor’s report of 12 December 2016 states:
I advised the client that I would be immediately calling claims and advising that there were
items at the property that required immediate attention and that I felt that the property was
unsafe…
- The carport is unsafe due to poor construction and could cause injury if it fails any
further.
- The solar array on the patio at the rear of the property is not sufficiently support ed and
potentially dangerous.
- The solar array on the roof is not sufficiently supported and is also potentially dangerous.
- The wiring in the electrical room is frighteningly dangerous and should be addressed
immediat ely, it is potentially life threatening to the residents of the property.
- There is a load bearing wall in the electrical room that is severely affected by termites
and has had bracing removed.
The reports indicate that the home was unsafe, not kept in good condition and not all
reasonable steps had been taken to prevent any loss or damage. The applicant has
therefore not met the conditions of cover under the policy.
Case No: 483243 Determination Page 5 of 8
The FSP can rely on policy exclusions to decline the majority of the claim.
FSP ’ s reports show faulty workmanship and unsafe electrical work
The above mentioned assessor’s report states:
I was not willing to stand close to the masses of exposed wiring and modified electrical
work there is present in this room. This room is extremely dangerous and urgent specialist
attention should be sought. There is imminent danger from fire and or electrocution in this
room.
The FSP’s electrician states the applicant has breached the Electrical Safety Act
2002 because he had disconnected the inverters from the mains switch himself.
The electrician also states the amount of solar panels on the roof far exceeds the
total amount the particular solar system is certified and designed to handle, and the
system has been heavily electrically overloaded.
The electrician states:
It is my professional opinion, based on the evidence I found during this inspection, that the
faults claimed on the 2 inverters in question were caused by an overloaded PV input
caused by the excess of panels for which the system was not design[ed] or certified.
In regards to the condition of the roof itself, the FSP’ s builder advised the tiles under
the solar panels have cracked allowing water ingress. This appears to have occurred
because of the incorrect installation and incorrect fixing of the solar panels and
supports. I determine that on the balance of probabilities the damage to the solar
system was caused by defective workmanship.
The proximate cause of most of the damage was not the storm
It is well-established law that a proximate cause is the effective, dominant or
operative cause.
It is evident there is faulty workmanship throughout the property including dangerous
and exposed electrical wiring and unstable structures on the roof. I do not accept the
storm alone caused the damage.
While the wind and storm may have caused airwaves, pressure and frequency
impulse, I do not think the electrical equipment and solar system would have been
damaged had the dangerous and defective electrical work not been present.
Additionally, I do not think the solar panels and roof sheeting would have been
damaged if the roof was kept in good condition and the solar supports were
structurally sound.
The FSP can decline the claim except for the TV antenna
I am satisfied that the majority of the damage was caused by structural defects, faulty
workmanship and the failure to maintain the home in good condition, not the storm.
The FSP can decline the claim for the damaged electrical equipment, solar charges
and the solar MTTP regulators.
T he FSP’s reports are consistent in identifying that the majority of the solar panels
had not been installed correctly, had insufficient support structure and there were too
Case No: 483243 Determination Page 6 of 8
many for what the roof could handle. This undermined the stability of the roof sheets
and tiles.
The FSP ’s assessor could not investigate the damage to the skylight vent properly
because of the safety risks with the property, solar system and roof struc ture.
However the assessor says it is more likely than not that the damage to the skylight
vent was caused by the:
…maintenance of the roof, due to the damage that has been incurred by it having the
insufficiently mounted and fixed solar system on it.
Thi s is consistent with the FSP’s builder’s report which stated the tiles under the
insufficient solar panel supports have cracked allowing water ingress.
I accept that it is likely that the wind gusts did in fact affect the TV antenna on the
date of the claimed event. I therefore consider it fair in the circumstances that the
FSP pay the applicant the cost of a replacement antenna. This is to be determined by
a valid and reasonable quote for replacement being provided by the applicant.
There is no reason to question the qualifications of the FSP’s experts
I accept the applicant is highly knowledgeable in the area of renewable energy.
However I do not accept his criticisms of the FSP’s contractors to be valid. The only
supporting information h e has to discredit the FSP’s experts is the report from CG he
provided after the recommendation.
However I note this report was provided after the applicant had already tampered
with the electrical equipment at his property. The FSP’s electrician advised:
The insured explains he had opened the inverters and had removed and replaced several
capacitors and transistors from the main printed circuit board in an attempt to fix one of the
inverters …there was very clear sign of tampering and soldering…
I do not accept that the applicant’s report from CG can make a conclusive statement
that the damage was from lightening and that the FSP’s r eports cannot be reliable.
CG’s report was a year after the event and eigh t months after the FSP’s electrician .
The applicant says his report from BI, his builder, was actually prepared by an
electrical service as well as the master builder. There is no information to support the
reference to an electrical service.
The applicant has provided a copy of his own CEC accreditation for the design and
installation of photovoltaic power systems. This accreditation was awarded after the
date of loss and after the applicant’s solar system had already been installed.
I am not satisfied the FSP’s experts or contractors lack cred ibility or appropriate
qualifications. However it is a question of balancing the independent evidence at
hand. In the circumstances, the FSP’s reports have significant weight.
2.2 Is the applicant entitled to further compensation?
The applicant has been refunded his premium for the remaining term
The FSP cancelled the applicant’s policy and advised it refunded the premium that
had been paid for the unused portion of the insurance term.
Case No: 483243 Determination Page 7 of 8
The applicant disputes having received the refunded premium.
The FSP has provided a screen shot of it system record which shows the $77.70
refund was made to the applicant’s nominated account on 9 December 2016.
On balance the FSP has made the required refund.
The applicant is entitled to $500 non-financial loss compensation
I agree with the recommendation in that the FSP took too long to communicate its
claim decision in writing to the applicant.
The applicant says he feels he is entitled to more than $500 in non-financial loss
compensation. However, I consider $500 to be a fair and accurate reflection of the
stress and inconvenience suffered by the applicant.
There is no reason the applicant could not have attended to repairs when he was
verbally advised of the decision on 23 December 2016 in order to mitigate his loss,
despite not having the decision in writing until 5 April 2017.
The FSP is to pay the applicant $500 in compensation within 14 days of his
acceptance of this determination.
Case No: 483243 Determination Page 8 of 8
3 Supporting information
3.1 FOS approach
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered for the purposes of this determination.
This dispute has been decided on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous Financial Ombudsman Service
(FOS) decisions.
3.2 Relevant policy extract s
The relevant policy extracts are referred to in the parties’ submissions , the
recommendation and in the FSP’s Notice of Response dated 20 June 2017. Both the
policy documents and the Notice have been exchanged with the applicant.
3.3 Other relevant material considered and relied on
Parties submissions, emails, reports, photographs and all attachments to all
submissions
The FSP’s expert reports including its electrical services report dated 29 March
2017, its assessor’s report of 12 December 2016 and its building assessor’s
report of 24 November 2016.
The applicant’s expert reports including his builder’s reports dated 10 January
2017, 7 February 2017 and 1 August 2017 as well as the report from his
nominated electrician with CEC accreditation dated 12 November 2017.
Recommendation
Case No: 483243 Recommendation Page 1 of 6
Case number: 483243 23 October 2017
4 Overview
4.1 Dispute
On 19 November 2016, the applicant lodged a claim with the financial services
provider (FSP) for damage at his property following a recent storm event.
The FSP assessed the damage and declined the claim, as it says factors excluded
from cover under the policy caused the damage, not the storm.
The applicant di sagrees with the FSP’s decision and seeks it to cover the claim. He
also raised issues with the FSP’s handling of the claim
4.2 Issues and key findings
Is the FSP entitled to deny the claim?
The FSP is entitled to deny the claim, because on balance:
the available information establishes the proximate cause of the damage is
design faults, structural defects or faulty workmanship
damage caused by design faults, structural defects or faulty workmanship are
expressly excluded from cover.
Is the applicant entitled to non-financial loss compensation?
The FSP took too long to communicate its claims decision in writing. This caused the
applicant unnecessary stress and frustration, for which he is entitled to $500 in non-
financial loss compensation.
4.3 Recommendation
This recommendation is substantially in favour of the FSP.
If both parties accept the recommendation, within a further 14 days of both parties’
acceptance, the FSP is to pay the applicant $500 in non-financial loss compensation.
Case No: 483243 Recommendation Page 2 of 6
5 Reasons for recommendation
5.1 Is the FSP entitled to deny the claim?
Applicant must show damage arose from an insured event
The applicant’s policy provides cover for loss or damage caused by specific events,
subject to the various conditions and exclusions set out in the policy. These events
include storm and rainwater damage.
It is an accepted principle of insurance law the applicant bears the onus of
establishing, on the balance of probabilities, he suffered a loss caused by a risk
covered under the policy. This is called a prima facie or valid claim.
If the applicant is able to establish a valid claim, the onus shifts to the FSP to show,
on the balance of probabilities, the loss falls within a policy exclusion or it is
otherwise able to deny liability.
Applicant established a valid claim
On 19 November 2016, the applicant lodged a claim after he says a storm event on
12 November 2016 caused the following damage to his home:
solar inverters not all working
a number of solar panels blown off roof and sustained impact damage
roof tiles under solar panel system have cracked, which has caused water
ingress to the bathroom ceiling
an additional 40 roof tiles have cracked from debris
bathroom ceiling – mould around the skylight due to water ingress from roof
swimming pool - 2 solar arrays
The FSP does not dispute there was a weather event at the time of the loss. Given
this, I am satisfied the applicant has established a valid claim.
As the FSP is seeking to deny the claim, it must establish on the balance of
probabilities that an exclusion applies or it is otherwise entitled to deny the claim.
On balance, factors excluded under policy caused the damage
In seeking to deny the claim, the FSP relies upon the following specific exclusion
under the storm insured event:
loss or damage caused by rain, hail, wind or dust due to:
a design fault, structural defect or faulty workmanship
Once the claim was lodged, the FSP engaged an assessor (A), builder (WB) and
electrician (RCES) to assess the damage. All experts agreed that:
the solar panels, and its support system, were not installed in compliance with
the relevant Australian standard
there was no indication of damage caused by the storm.
Case No: 483243 Recommendation Page 3 of 6
Additionally, A considered the roof was not maintained, and this was the cause of the
damage, not the storm. Section 3.1 of this recommendation outlines the key points
of the FSP’s experts.
In response, the applicant provided a quote and report from his expert builder (BICF),
which confirmed the cause of damage was strong wind gusts and a lightning strike.
However, BICF did not provide any reasons supporting its conclusion, nor did the
report challenge any of the FSP experts’ findings.
Further, the applicant made submissions based on his own qualifications and
experience. The applicant went into great detail in ch allenging the FSP’s expert
reports. In weighing up the expert reports submitted by the parties, I ultimately prefer
the FSP’s experts as they collectively provide a credible account on the proximate
cause of the damage. In contrast, the applicant did not provide expert information
independent of him, save for BICF’s limited account on the cause of damage.
Information supports FSP’s experts as being appropriately qualified
The applicant says the FSP made wrong decisions based on unqualified reports and
dispu tes the qualifications of the FSP’s experts.
In response, the FSP says it is satisfied its experts have the relevant qualifications
and expertise to assess the damage. Upon request by this Service, the FSP provided
responses from its various experts detailing their relevant qualifications.
As part of his material submitted to this Service, the applicant submitted information
about his qualifications. The applicant says he has a PhD in electronics and control
systems and consults for a university in electro nics. He says he has all the relevant
qualifications for the design and installation of solar power systems.
I have carefully reviewed the information submitted by the applicant in this regard.
This included a PhD in Technical Sciences in1985 and a Diploma in Design Engineer
– Computer Technologist in 1984, both from an overseas university. The applicant
did not provide any information showing these qualifications comply with Australian
requirements or standards.
In addition, the applicant does not appear to have completed his Advanced Diploma
of Engineering Technology, noting he has completed 240 points out of a required
1260 points.
The applicant also provided a certificate from the Clean Energy Council showing he
is an accredited installer for SPS PV Design and install of photovoltaic power
systems.
While I appreciate the information provided by the applicant, in my view, it does not
establish that his qualifications and training are to be preferred. Additionally, I am
otherwise satisfied the FSP’s exper ts are suitably qualified.
FSP entitled to deny the claim
For the reasons set out above, I am satisfied the available information establishes
design faults, structural defects or faulty workmanship was the cause of damage.
Case No: 483243 Recommendation Page 4 of 6
As the policy excludes damage caused by these factors, it follows the FSP is entitled
to deny the claim.
Additionally, as the applicant accepts the carport was not constructed properly, I
have not considered this item as part of this dispute.
5.2 Is the applicant entitled to non-financial loss compensation?
FOS can award compensation in certain circumstances
FOS is able to award compensation for non-financial loss (capped at $3,000 per
claim of compensation) where there has been:
an unusual degree or extent of physical inconvenience
time taken to resolve the situation
interference with an applicant’s expectation of enjoyment or peace of mind.
However, FOS takes a conservative approach to compensation for non-financial loss.
FOS expects an applicant to be moderately robust and bear the normal degree of
inconvenience experienced when a problem occur and take reasonable steps to
reduce inconvenience.
Applicant entitled to $500 in non-financial loss compensation
The FSP provided a time line of the claim which shows the following critical dates:
19 November 2016 – claim lodgement
23 December 2016 – applicant verbally advised claim was declined
5 April 2017 – claim declined in writing
Notwithstanding the FSP verbally advised the applicant of its decision on 23
December 2016, it took too long to communicate its position in writing.
The FSP’s own time line shows between the period 25 January 2017 to 20 March
2017, the FSP contacted the applicant twice.
The applicant says his emails to the FSP were often returned as undelivered and
although he has receipts of FSP staff receiving his emails, staff denied receiving
these documents. He says he made numerous calls to the FSP and the FSP’s
communication to him was poor.
Even allowing for the Christmas and New Year period, ultimately, in the
circumstances I do not accept the FSP considered the claim decision in a reasonable
timeframe.
Its delay in communicating its decision in writing is contrary to the General Insurance
Code of Practice and caused the applicant unnecessary stress and frustration. For
this reason, the applicant is entitled to $500 in non-financial loss compensation
Case No: 483243 Recommendation Page 5 of 6
6 Supporting information
6.1 Relevant policy terms
Insured event We will NOT cover:
6. Storm and rainwater
Including loss or damage from:
the escape of rainwater from any
water pipe, drain or gutter
surfac e run - off rainwat er from
surrounding areas that occ urs
wit hin 24 hours of a st orm or
heavy rain.
Including loss or damage caused by
erosion, subsidence, landslide,
mudslide or any ot her eart h
movement t hat occ urs wit hin 72
hours of a storm or heavy rain and
as a res ult of t hat st orm or heavy
rain.
…
loss or damage c aused by rain,
hail, wind or dust due t o:
a design fault, structural defect or
faulty workmanship
6.2 Expert reports
Expert Key findings
WC the support system for the solar panels is not sufficient and this has
caused/allowed the damage to occur.
If the solar panels and structure to the side of the house were built to
code, with adequate tie downs and flashings, the damage would not
have occurred.
The solar panels have not been installed to code as the materials used
are not suitable for the application.
A’s first report
12 - 12 - 2016
the two solar arrays (on the patio at the rear of property and on the
roof) are not sufficiently supported ad potentially dangerous
the wir ing in the electrical room is frighteningly dangerous and should
be addressed immediately. It is potentially life threatening to the
residents of the property.
a load bearing wall on the electrical room is severely affected by
termites and has had bracing removed.
A’s second report
19 - 11 - 2016
the solar roof remains improperly installed and will not comply with
AS1170. 2. Damage would not have occurred if it was properly installed.
Multiple areas of the applicant’s system do not comply with the relevant
Aust ralian Standards.
There is no visible storm damage to the property. Any damage or poor
condition is due to either maintenance, improper or negligent installation
and modification of various items or in the case of the bracing wall,
Case No: 483243 Recommendation Page 6 of 6
termites and modificatio n.
RCES report
29 - 03 - 2017
noted there was evidence of considerable tampering of the two invert ers
since WC attended, which applicant admitted to in breach of the
Electrical Safety Act 2002 . The applicant advised he did not hold a Qld
electrical work licence.
69 panels were counted on the roof and pergola. This exceeds the 21
panels the system is certified to and what the system, including
inverters, was professionally designed to handle.
the certified system has been heavily electrically overloaded an d the
mounting and support systems of the panels are not up to the Australian
standard.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.