Determination 482790

Water leak claim declined and further testing refused

FirmFinancial Firm (Unknown - Insurer)
Decided2018-08-08
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's property suffered recurring water ingress and the FSP declined the 2015 claim as groundwater seepage and agricultural pipe leakage. AFCA found the applicant had not shown an insured escape of liquid, the FSP need not fund further testing beyond the $1,000 limit, and it could reconsider on new evidence.

The insured-events policy requires proof of an escape of liquid event, and exploratory costs are capped at $1,000 where that event is not established.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 482790 Determination Page 1 of 9 Case number: 482790 8 August 2018 1 Overview 1.1 Dispute In 2015, t he applicant’s property suffered water damage , and a claim was lodged under his home building insurance policy held with the financial services provider (FSP). The applicant had lodged two previous related claims for water damage with the FSP, each of which has been the subject of a separate FOS determination. The current claim (in respect of water damage identified in 2015) was initially accepted by the FSP, as the water responsible for the damage was leaking from a leach pipe. However, the FSP later denied the claim on the basis it was from seepage through the earth, and also because there was leaking or overflowing from agricultural pipes. Both of these causes of damage are excluded. As well as now denying liability for the loss, the FSP has refused to undertake any further investigations. The applicant is not satisfied with the FSP’s decisio n. He does not believe the FSP has addressed all potential causes of the damage. 1.2 Issues and key findings Is the FSP entitled to refuse to undertake further testing at the site? The FSP has acted in accordance with its obligations under the policy, and has not acted unreasonably in investigating the source of the damage to date. It is not required to incur additional costs above the policy limit by undertaking further testing , given the currently available evidence. The applicant is free to undertake his own investigations should he wish. Is the FSP entitled to deny the applicant’s claim? On the available evidence, t he FSP is entitled to deny the applicant’s claim . That is because the applicant has not established, on balance, the damage has arisen from an event insured under the policy. However, should the applicant obtain further relevant evidence, then the FSP should re-assess the claim having regard to that. 1.3 Determination This determination is in favour of the FSP. The FSP is not required to undertake fu rther investigations. It is also entitled to deny liability for the applicant’s claim on the currently available evidence. Case No: 482790 Determination Page 2 of 9 2 Reasons for determination I have decided this case on the basis of what I consider fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties. For the purposes of this determination, I will deal with only those points considered relevant. 2.1 Is the FSP entitled to refuse to undertake further testing at the site? Policy provides cover for exploratory costs The policy provides cover for exploratory costs under the insured event ‘ Escape of Liquid ’ . The policy says the FSP will pay the reasonable cost of locating, at the insured address (my underlining), the source of the escaped liquid and the cost to repair and restore the damage to the building caused by its exploratory work, but only if the claim is covered under the ‘ Escape of liquid ’ event. If the leak is not covered under the ‘Escape of Liquid’ event , such costs are catered for under additional cover for ‘ Exploratory costs where a leak is not covered under insured event Escape of Liquid ’ . Under the additional cover, the FSP will pay the cost to locate the source of liquid escaping or overflowing at the insured address and to repair and restore the damage to the building caused by its exploratory work, if the escape of liquid first happens during the period of insurance. There is a limit of $1,000 for each incident applying to this benefit. Applicant has not established an entitlement to ongoing exploratory costs For the applicant to be entitled to claim ongoing exploratory costs, he needs to establish his claim is covered under the event ‘Escape of Liquid’. If he is unable to do so, cover for exploratory costs is limited to $1,000 per incident. For the reasons outlined in section 2.2 below, the applicant has not demonstrated his claim is covered under the insured event ‘Escape of Liquid’. So, the extent of the FSP’s liability for exploratory costs is limited to $1,000. The FSP ’s evidence indicates the costs incurred to date in investigating the cause of the leak exceed $1,000. On that basis, the FSP is not required to continue to investigate potential causes for the loss. Case No: 482790 Determination Page 3 of 9 2.2 Is the FSP entitled to deny the claim? Previous FOS decisions are relevant to this claim Claim 1 In August 2010, FOS determination 201158 was issued after the applicant made a claim (‘Claim 1’) for rectification works for water damaged walls in 2009, and for further assistance in determining the cause of the recurring water damage. The determination was that the FSP was entitled to decline the claim. That was because the evidence available at the time had not established that the damage was from an insured event. That also meant the FSP was not required to undertake further investigations, as it had already spent $1,000 on exploratory costs. Claim 2 In 2015, similar damage occurred and the applicant made a claim for that damage. The FSP initially accepted that claim, on the basis that the cause of the damage was a broken leach pipe. Claim 3 Given the further evidence found in the course of investigating Claim 2, the applicants lodged a new claim to have the previously rejected rectification works (Claim 1) covered. FOS determination 426553 was issued in favour of the applicants for Claim 3. This was on the basis that the new evidence established, on balance, that the 2009 damage was from the same leak as the 2015 damage, and the FSP had not shown it was otherwise entitled to decline the claim. Current dispute The FSP then conducted further investigations into Claim 2, regarding the 2015 damage. Given the new evidence obtained, the FSP decided to decline that claim, saying the damage was the result of ground water seepage and leaking from an agricultural pipe (both of which are excluded under the policy). This determination deals with the FSP’s decision to now decline Claim 2, in the light of all the evidence currently available, including that obtained since Claim 3 was decided. Policy covers escape of liquid in certain situations The applicant is required to show, on the balance of probabilities, he has suffered a loss caused by a risk insured against under the policy. This is known as a prima facie or ‘valid’ claim. The policy is an ‘insured events’ policy, which means the damage needs to have arisen from one of the events specifically listed in the policy, for cover to apply. If the applicant is able to establish a valid claim under an insured event, the onus shifts to Case No: 482790 Determination Page 4 of 9 the FSP to show, on the balance of probabilities, it is entitled to rely on an exclusion under the policy or is otherwise entitled to deny the claim. The policy covers the insured event of ‘escape of liquid’ : that is, for damage or loss occurring during the period of cover caused by liquid leaking, overflowing or bursting from a water main, drain, fixed pipe or drainage and sewage systems. Based on the available evidence (and as considered in more detail below), I am not satisfied the applicant has shown, on balance, that the damage falls within the policy requirements for that insured event. The policy also excludes cover under that insured event for damage or loss resulting from liquid escaping gradually over a period of time, where the applicants could reasonably be expected to be aware of this; as well as for leaks from agricultural pipes. In addition, there is a general policy exclusion for ‘seepage of water’ through the earth or from agricultural pipes. New evidence does not establish, on balance, damage was from excluded causes The evidence of the FSP’s leak detection specialist plumber, PP, in their report of 6 April 2016, indicated that issues with, and leaking from, the leach pipes had caused the 2015 and 2009 damage. The FSP did not provide anything further to refute that ; nor did the FSP argue at the time that the leach pipes were ‘agricultural pipes’, and therefore excluded. It was on that basis that Claim 3 was resolved. Subsequently however, the FSP arranged for further investigations and reports: including two more from PP; three from MP, engineers; six from its assessors, DK and LJ. There is also an undated report from SH, plumbers, authorised by the local council to conduct a CCTV survey of the common effluent pipe at the rear of neighbouring property. Based on the investigations up to that point in time, MP in January 2017 provided the opinion that groundwater was ‘at least, contributing’ to the water damage issue at the insured property; but that leakage of ‘ water supply, sewer or stormwater pipework on the insure d’s property’ wa s not a contributory factor. MP also did not consider the problem to be related to water leaking or overflowing from the swimming pool. MP did however note there may be leakage in the pipework situated on the neighbouring properties higher up in the topography that could be contributing. MP also suggested water emanating from the ‘ agricultural type drain ’ behind the retaining wall, as a result of ‘possible deficiencies in its construction’ , could be contributing to the damage. (It is worth noting that in MP’s September 2016 report, that drainage arrangement was referred to as ‘perforated drainage pipe’ , rather than ‘agricultural’ ). This opinion apparently took account of the fact that even after repairs by PP to those pipes, water continued to enter the lower level of the building. The FSP submits it is entitled to deny the claim, as leaks from agricultural pipes and water seeping or running from agricultural pipes, or through the earth, are causes of damage specifically excluded under the policy. Case No: 482790 Determination Page 5 of 9 However, I do not consider the wording of MP’s reports suggests a conclusive or compelling outcome of the investigations to date. MP refers to ‘the possible influence of groundwater’ and ‘ possible deficiencies’ in the pipework construct ion, in that the drains are apparently connected to the overall stormwater drainage system, and so are vulnerable to backflow. However, on the latter point, MP went on to say that stormwater backflow was not responsible for the problem, because if it was, water would only be coming out of the pipe during periods of rainfall (and the evidence is that the source of moisture appears to be constant/regular). There is also the question of why the pipework has only more recently been identified as being ‘agricultural pipes’, and excluded for that reason – when the FSP had previously agre ed that leaks from ‘leach pipes’ were acceptable. My understanding is that the use of leach pipes is not unusual in residential drainage situations, the purpose being specifically to allow water to pass through the soil and perforations in the pipes. The policy does not define ‘agricultural pipes’. There may be certain similarities between the form or configuration of leach pipes used in a residential context, and other similar pipes used in an agricultural situation. However, I am not satisfied, on the available evidence, that it is fair to attempt to exclude cover in this case simply on the basis that the leakage was from ‘agricultural pipes’. That is particularly so when the evidence does not show that was the proximate cause of the damage in any case : MP considered there was also a lack of effective waterproofing measures in the affected part of the building, and reported that damage still would have occurred in the absence of a leak from the blocked perforated pipe. In addition, even if there were issues in the construction of that pipework, there is no evidence the applicant knew or should reasonably have known about that; and in any case, steps were previously taken to repair the problems that had been identified. That means the exclusion for defect, structural fault or design fault should not apply. Further investigation has been suggested The FSP’s evidence to date suggests a number of possible contributory factors, b ut does not clearly identify the likely proportionate impact or effect of those factors. Nor am I satisfied that the applicant has shown, on balance, that the cause of the damage is from an ‘escape of liquid’ as provided for under the policy. As the applicant has pointed out, MP has suggested several further specific investigations that might be undertaken to help identify the source of the water and cause of the damage to the property. It is possible those investigations might assist in identifying the proximate cause of the problem (that is, the effective, operative or dominant cause). However, the FSP has already undertaken significant exploratory work at and near the property, and none of those investigations has yet found the damage falls within the ‘escape of liquid’ cover (regardless of whether any exclusions would apply). I appreciate that MP has suggested possible further investigations which might be undertaken; and I acknowledge the applicant’s belief that these should be pursued. However, I consider the steps taken by the FSP to date were not unreasonable under the circumstances. I also note that the policy refers to investigation/exploratory work Case No: 482790 Determination Page 6 of 9 ‘at the insured property’, and it appears that at least some of the remaining options would involve access to other properties. The applicant has the option of undertaking his own further investigations into the cause of the water damage. If he did, and new evidence was found which reasonably supported a conclusion other than that currently identified, he would be entitled to bring that to the FSP’s attention and request a reconsideration of the claim. In the meantime, however, the applicant has failed to demonstrate the cause of the damage was the result of an event covered by the policy, and so the FSP is entitled to deny the claim. Case No: 482790 Determination Page 7 of 9 3 Supporting information 3.1 FOS has jurisdiction to consider this dispute Under its terms of reference (TOR), FOS may not consider a dispute where the same events and facts are brought by the same applicant as a dispute previously dealt with by FOS. This is unless there is sufficient additional evidence and facts raised in the n ew dispute to warrant FOS’ consideration of the new dispute. I consider the current dispute does involve the same events and facts as disputes 201158 and 426553. However, I am satisfied that the FSP’s change of position from acceptance to the denial of the 2015 claim (since the issuing of determination 426553 , and referred to in that determination as ‘claim 2’ ), and the subsequent additional expert evidence provided , are sufficient to warrant FOS’s consideration of this new dispute. 3.2 Key documents Record K ey points FSP’s assessor (DK) 6 April 2017  Recommended claim be declined as damage not found to have been caused by leaking pipe at the insured property. Plumber SH Undated  No cracks or fractures evident along the entire CWMS (common effluent ) line  Structural integrity of all joints along the line appear to be in good condition FSP’s engineer (MP) Report 30 March 2017  On the basis of SH’s report and its CCTV foot age, MP do not believe a leak in the common effluent pipe (to the extent it has been t ested) could be contributing to the problem.  Suggested possible leaking pipework at neighbouring property could have cont ributed, given evidence of plumbing work there, but unable to establish this  Suggested possible further investigations – pipework on ne ighbouring properties, chemical testing of water, assessment of insured’s stormwater capacity  Maintained ‘opinion that ephemeral ground water infiltration is still a probable contributor to the moisture ingress. This will remain our opinion even if anot her possible source of moisture is identified through further investigation.’ FSP’s engineer (MP) Report 17 January 2017 (supplementary to MP report 9 Sept ember 2016)  Identified 5 possible moisture sourc es: leaking stormwater pipework, leaking sewer pipework, leaking water supply pipework, overflow from swimming pool, natural groundwater.  Most recent plumbing inspection found no leaks in water supply or sewer/ waste pipework (consi stent with previous findings, and with insured’s reports that moi sture is only observed after periods of rainfall). Case No: 482790 Determination Page 8 of 9  Plumbing inspection indicates no leaks were detected in the stormwat er pipework which were capable of causing the extent of moisture ingress observed. FSP’s assessor ( LJ ) Report 1 4 Nov ember 2016  Assessor has spoken with engineer (MP) to clarify what he describes as a leaking drainage pipe.  The pipe in question is the perforated pipe situated at the base of the retaining wall (earth side) to collect water as it drains through the soil and disperse it elsewhere so as to limit the degree of moisture build up and or hydrostatic pressure that the wall would be subjected to otherwise.  This pipe is an AG (agricult ural) Pipe. Liquid is unable to leak from it as it is designed to fill up wit h water which then drains. If the pipe is blocked the ag pipe will reach a point where it cannot take in any more water therefore saturating the soil due to the pipe not being able to take any more water in. This is not a leaking pipe. FSP’ s engineer (MP) Report 2 September 2016  Identified 3 types of damage in the lower level: slab edge dampness, rising/falling dampness, actual moisture ingress  Identified two possible sources of this moisture: groundwater and/or water flowing out of perfora t ed drainage pipe behind retaining walls  Ephemeral groundwater is a phenomenon known to exist in hilly areas…during periods of sustained rainfall. Stormwater i nfiltrates the top soil layers and perches above an impermeable soil horizon (s uch as highly pla stic clay or rock, both of which are common in the [local] soil strata) where it flows under gravity according to the surrounding topography.  It is possible ephemeral groundwat er, sourced from higher in the surrounding topography, travels downhill towards the home after periods of sustained rainfall. Based on the apparent slope of the surrounding terrain, potential groundwater’s flow would be int ercept ed by the Lower Level retaining walls. Groundwat er would then accumulate against these walls and beneath th e floor slab.  We note that the insured’s property is positioned relatively close to a ridge in the surrounding topography. Consequently, ephemeral groundwater flow rates would be somewhat limited as the contributing catchment area is limited.  Noted that PP had repaired partially blocked and leaking drainage pipe, but further moisture ingress had been occurring since those repairs. Prior to repair, the pipe likely contribut ed to the damage, but ‘we do not believe it is the dominant cause’.  Noted inadequacies in waterproofing on lower level  Concluded: 1. ‘the moisture ingress problems are likely to be an ongoing problem…due to the construction of its retaining walls and the probable absence of effective waterproofing measures’ and 2. ‘whilst moisture leaked fr om the blocked Case No: 482790 Determination Page 9 of 9 perforated pipe would have contributed to the damage, the damage would still have occurred in the absence of leakage from the pipe’ FSP’s plumber (PP) Report 23 August 2016  Suggested that ‘although repairs to a major break in this leach drain were undertaken previously that increased subsoil ground water inflows are not being totally captured by this leach drain’.  Suggested that ‘under heavy rain events…this drain could back up…’  ‘…with increased heavier rainfall it could be possible for tracking of water past the leach drain’. FSP’s plumber (PP) Report 6 April 2016  Found a gap in the leach pipe , and a broken join under the stairs  Pipe found to be filled with sand, and still blocked after hydro jet cleaning, and not in use  We would consider that stormwater backing up from the system prior to our first investigation and subsequent hydro jet cleaning of the system has been flowing out from this broken/ void in the drain and then soaking into the adjacent brick wall of the storage room.  We would suggest that this termination and subsequent break in the leach pipe system has been present since construction of the property and that initial overflows probably dispersed into surrounding ground. We would consider that over time this surroundin g soil probably became silted and blocked up hence leading to the current situation whereby the overflow now penetrat es the wall adjacent.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.